Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantioselective separation of azole compounds by EKC. Reversal of migration order of enantiomers with CD concentration: research article

  • Castro Puyana, María|||0000-0003-1412-4103
  • Crego Navazo, Antonio Luis|||0000-0002-4083-5294
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • García Ruiz, Carmen|||0000-0001-5925-3449
The enantioselective separation of a group of six weak base azole compounds was achieved in this work using EKC with three neutral beta-CDs as chiral selectors. The native beta-CD and two other beta-CD derivatives with different types and positions of the substituents on the CD rim ((2-hydroxy)propyl-beta-CD (HP-beta-CD) and heptakis-2,3,6-tri-O-methyl-beta-CD (TM-beta-CD)) were employed. Apparent binding constants for each pair compound-CD were determined in order to study analyte-CD interactions. The best enantiomeric resolutions for miconazole, econazole, and sulconazole were observed with HP-beta-CD whereas for the separation of the enantiomers of ketoconazole, terconazole, and bifonazole, TM-beta-CD was the best chiral selector. The enantioseparations obtained were discussed on the basis of the structure of the compounds taking into account that inclusion into the hydrophobic CD cavity occurred through the phenyl ring closer to the azole group. In addition, a change in the migration order for the enantiomers of two of the compounds studied (ketoconazole and terconazole) with the concentration of HP-beta-CD was observed for the first time., The authors thank the Ministerio de Ciencia y Tecnología and the Ministerio de Educación y Ciencia (Spain) for research projects BQU2003-03638 and CTQ2006-03849/BQU, respectively. Authors also thank Johnson & Johnson (Beerse, Belgium) for the kind gift of terconazole racemate and pure 2R,4S-enantiomer of the ketoconazole. Carmen García-Ruiz thanks the Ministerio de Ciencia y Tecnología (Spain) for the Ramón y Cajal program (RYC-2003-001). María CastroPuyana thanks the University of Alcalá for her predoctoral grant
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Separation of etodolac enantiomers by capillary electrophoresis. Validation and application of the chiral method to the analysis of commercial formulations

  • Rodríguez de Pablos, Raquel
  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Crego Navazo, Antonio Luis|||0000-0002-4083-5294
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
Separation of etodolac enantiomers, which exhibit different biological activity and pharmacokinetic profiles, has been achieved using the randomly substituted (2-hydroxy)propyl-β-cyclodextrin (HP-β-CD) as chiral selector in capillary electrophoresis. The selection of this CD was made after screening of different CD derivatives of neutral and anionic nature. The effect on the enantioresolution of the buffer concentration and of the degree of substitution (DS) and concentration of the CD as well as of instrumental parameters, such as the capillary temperature and the separation voltage, were studied. The highest resolution of etodolac enantiomers was around 2.5 using 100 mM phosphate buffer (pH 7.0) with 20 mM HP-β-CD (DS , 4.2) and UV detection at 225 (10) nm with a reference wavelength at 360 (50) nm. Validation of the chiral method in terms of selectivity, linearity, precision (instrumental repeatability, method repeatability, intermediate precision), and the limits of detection and quantitation allowed to evaluate its quality to the analysis of etodolac enantiomers in different pharmaceutical preparations containing racemic etodolac.
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Identification and quantitation of cis-ketoconazole impurity by capillary zone electrophoresis-mass spectrometry

  • Castro Puyana, María|||0000-0003-1412-4103
  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Cifuentes Gallego, Alejandro
  • Crego Navazo, Antonio Luis|||0000-0002-4083-5294
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
trans-Ketoconazole was identified and quantified as impurity of cis-ketoconazole, an antifungal compound, by capillary zone electrophoresis–electrospray–mass spectrometry (CZE–ESI–MS). The chirality of this impurity was demonstrated separating their enantiomers by adding heptakis-(2,3,6-tri-O-methyl)-β-cyclodextrin to the separation buffer in capillary electrophoresis (CE) with UV detection. However, MS detection was hyphenated to the CE instrument for its identification. As both compounds are diastereomers, they have the same m/z values and are needed to be separated prior to the MS identification. A 0.4 M ammonium formate separation buffer at pH 3.0 enabled the separation of the impurity from cis-ketoconazole. Under these conditions, the optimization of ESI–MS parameters (composition and flow of the sheath–liquid, drying temperature, drying gas flow, and capillary potential) was carried out to obtain the best MS sensitivity. CZE–ESI–MS optimized conditions enabled the identification of trans-ketoconazole as impurity of cis-ketoconazole. In addition, the quantitation of this impurity was achieved in different samples: cis-ketoconazole standard and three different pharmaceutical formulations (two tablets and one syrup) containing this standard. In all cases, percentages higher than 2.0 were determined for the impurity. According to ICH guidelines, these values required the identification and quantitation of any impurity in drug substances and products., Authors thank the Ministry of Science and Technology (Spain) for the research project BQU2003-03638. Carmen García-Ruiz thanks the Ministry of Science and Technology for the Ramón y Cajal program (RYC-2003-001). María CastroPuyana thanks the University of Alcala for her pre-doctoral grant.
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantioselective separation of the sunscreen agent 3-(4-methylbenzylidene)-camphor by electrokinetic chromatography: Quantitative analysis in cosmetic formulations

  • Gómara Moreno, Belén
  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
3-(4-Methylbenzylidene)-camphor (MBC) is a chiral sunscreen agent used in cosmetic products. In this work, the enantioseparation of MBC has been performed by EKC and applied to the analysis of the MBC enantiomers in cosmetic creams. Different experimental conditions (type and concentration of the chiral selector, temperature, and sample solvent) have been optimized. Due to the neutral nature of this compound, anionic CD derivatives were investigated as chiral selectors. Carboxymethylated-β-CD (CM-β-CD) showed the highest chiral separation power, observing that a 15 mM concentration of this CD at a working temperature of 15°C enabled to obtain the highest enantioresolution. However, under these conditions, tailing of peaks obtained for the enantiomers was observed. The addition of increasing concentrations of the neutral α-CD to CM-β-CD at a 15 mM concentration in a 100 mM borate buffer at pH 9.0 improved the enantiomeric separation and decreased peak tailing. The use of DMF for the total dissolution of the cosmetic creams, and methanol:water (1:1 v/v) for appropriate dilution enabled to observe good shape and size for the peaks of the MBC enantiomers. After optimizing a method for the preconditioning of the capillary, the analytical characteristics of the chiral separation method for the analysis of MBC were investigated. Linearity, LODs and LOQs, precision (instrumental repeatability, method repeatability, intermediate precision), accuracy, and selectivity were evaluated. The method was applied to analyze MBC enantiomers contained in two commercial cosmetic creams containing racemic MBC and to study the skin absorption of this compound with time., Authors thank the Ministry of Science and Technology (Spain) for the research project BQU2003-03638. C.G.-R. thanks the Ministry of Science and Technology for the Ramón y Cajal program (RYC-2003-001). B.G. thanks CSIC and the RYC-2003-001 project for the grants. Authors also thank Cyclolab (Budapest, Hungary) for the kind gift of CE-b-CD used in this work
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Sensitive chiral analysis by capillary electrophoresis. Review

  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
In this review, an updated view of the different strategies used up to now to enhance the sensitivity of detection in chiral analysis by CE will be provided to the readers. With this aim, it will include a brief description of the fundamentals and most of the recent applications performed in sensitive chiral analysis by CE using offline and online sample treatment techniques (SPE, liquid-liquid extraction, microdialysis, etc.), on-column preconcentration techniques based on electrophoretic principles (ITP, stacking, and sweeping), and alternative detection systems (spectroscopic, spectrometric, and electrochemical) to the widely used UV-Vis absorption detection., Ministerio de Ciencia y Tecnología, Ministerio de Educación y Ciencia
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Separation and online preconcentration by multistep stacking with large-volume injection of anabolic steroids by capillary electrokinetic chromatography using charged cyclodextrins and UV-absorption detection

  • Urban, Pawel L.
  • García Ruiz, Carmen|||0000-0001-5925-3449
  • García González, María Ángeles|||0000-0001-6292-8232
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
The separation of three common anabolic steroids (methyltestosterone, methandrostenolone and testosterone) was performed for the first time by capillary EKC. Different charged CD derivatives and bile salts were tested as dispersed phases in order to achieve the separation. A mixture of 10 mmol/L succinylated-b-CD with 1 mmol/L bCD in a 50 mmol/L borate buffer (pH 9) enabled the separation of the three anabolic steroids in less than 9 min. Concentration LODs, obtained for these compounds with low absorption of UV light, were ~5610–5 mol/L. The use of online reverse migrating sample stacking with large-volume injection (the effective length of the capillary) enabled to improve the detection sensitivity. Sensitivity enhancement factors (SEFs) ranging from 95 (for testosterone) to 149 (for methyltestosterone) were achieved by single stacking preconcentration. Then, the possibilities of multistep stacking to improve the sensitivity for these analytes were investigated. SEFs obtained by double stacking preconcentration ranged from 138 to 185, enabling concentration LODs of 2.79610–7 mol/L (for methyltestosterone), 3.47610–7 mol/L (for testosterone) and 3.56610–7 mol/L (for methandrostenolone). Although online triple stacking preconcentration was achieved, its repeatability was very poor and SEFs for the studied analytes were not calculated., Ministerio de Ciencia y Tecnología, Ministerio de Educación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Recent advances in the analysis of antibiotics by capillary electrophoresis

  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
In this review, the main aspects related to the separation of different groups of antibiotics by CE as well as the different applications reported in the literature from the beginning 2003 till May 2005 will be provided to the readers. Firstly, the experimental conditions employed to achieve the analysis of antibiotics by CE are given. Then, the main applications performed in the pharmaceutical, clinical, food, and environmental fields have been reviewed making emphasis on sample preparation requirements needed in each case. Finally, the main conclusions and future prospects in this field are presented.
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric separation of organophosphorus pesticides by capillary electrophoresis. Application to the determination of malathion in water samples after preconcentration by off-line solid-phase extraction

  • García Ruiz, Carmen|||0000-0001-5925-3449
  • Álvarez Llamas, Gloria
  • Puerta, Ángel
  • Blanco, Elisa
  • Sanz Medel, Alfredo
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
The separation of the enantiomers of a group of organophosphorus pesticides (OPs) has been investigated by electrokinetic chromatography (EKC) using different anionic cyclodextrins as chiral selectors. The use of a 25 mM Tris buffer (pH 7.0), 20 mM in CM-β-CD together with an applied voltage of 24 kV and a temperature of 25 °C enabled the individual enantiomeric separation of malathion and phenthoate each one into its two enantiomers, the partial separation of the enantiomers of phenamiphos and the separation of three of the four enantiomers of isomalathion. Since naled is very reactive in aqueous solutions, its enantiomeric separation achieved in about 8 min in 25 mM borate buffer at pH 9 with 10 mM CM-β-CD resulted in the observation of a broad peak due to degradation products. A preconcentration step by disk solid-phase extraction was studied and used together with the chiral EKC method developed for the enantiomeric separation of malathion in order to determine this pesticide in tap water samples spiked at the μg mL−1 level. Finally, the precision and recovery of the method was established., Authors thank the Ministry of Science and Technology (Spain) for the research project BQU2003-03638. C. García Ruiz also thanks this Ministry for the Ramón y Cajal program (RYC-2003-001)