BULERIA. Repositorio Institucional de la Universidad de León
Publication Artículo científico (JournalArticle)

Weather features associated with aircraft icing conditions: a case study

  • Fernández González, Sergio
  • Sánchez Gómez, José Luis
  • Gascón Salvador, Estíbaliz
  • López Campano, Laura
  • García Ortega, Eduardo
  • Merino Suances, Andrés
[ES] In the context of aviation weather hazards, the study of aircraft icing is very important because of several accidents attributed to it over recent decades. On February 1, 2012, an unusual meteorological situation caused severe icing of a C-212-200, an aircraft used during winter 2011-2012 to study winter cloud systems in the Guadarrama Mountains of the central Iberian Peninsula. Observations in this case were from a MP-3000A microwave radiometric profiler, which acquired atmospheric temperature and humidity profiles continuously every 2.5 minutes. A Cloud Aerosol and Precipitation Spectrometer (CAPS) was also used to study cloud hydrometeors. Finally, ice nuclei concentration was measured in an isothermal cloud chamber, with the goal of calculating concentrations in the study area. Synoptic and mesoscale meteorological conditions were analysed using the Weather Research and Forecasting (WRF) model. It was demonstrated that topography influenced generation of a mesolow and gravity waves on the lee side of the orographic barrier, in the region where the aircraft experienced icing. Other factors such as moisture, wind direction, temperature, atmospheric stability, and wind shear were decisive in the appearance of icing. This study indicates that icing conditions may arise locally, even when the synoptic situation does not indicate any risk, SI, This paper was supported by the following Grants: TECOAGUA, Micrometeo.com, and Granimetro (CGL2010-15930) and LE220A11-2 and LE003B009 awarded by the Junta de Castilla y León and MINECO
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimization of chemical cleaning of a reverse osmosis membrane from a desalination plant by means of two step static tests

  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
  • Alvarez Blanco, Silvia
  • Sancho, M.|||0000-0002-9566-1949
  • Gimenez Anton, Adria Carles
Research in cleaning procedures of reverse osmosis membranes used in seawater desalination to minimize costs and achieve high efficiency is necessary. Multi-step cleaning can represent a useful tool, since the cleaning efficiency can be improved by means of utilization of different chemicals with complementary cleaning mechanisms. The objective of this work was the optimization of a two-step cleaning procedure to recover the membrane properties and reduce power costs. Spent Hydranautics SWC3 membranes (USA) were supplied by a desalination plant. Cleaning tests were performed in three stages: one-step static cleaning, two-step static cleaning and characterization of the membrane surface after the cleaning process. Four cleaning agents at two different concentrations were used. All possible combinations of them were considered, including sequence effect. After the cleaning process, membrane surface was characterized by field emission scanning electron microscopy coupled with energy dispersive X-ray spectroscopy and atomic force microscopy. One-step static cleaning test indicated that sodium dodecyl sulphate 1% w/v was the most efficient cleaning solution, followed by NaOH 2% w/v. Two-step cleaning tests showed that the procedure that maximized permeate flux recovery was surfactant-alkaline cleaning, whereas the one that maximized the recovery of the salt rejection index was alkaline-acid sequence. Characterization of the membrane surface after the cleaning steps confirmed that fouling deposits were significantly removed., The authors wish to thank Abengoa Water, S.L. for the financial support given to this research through the project "Cleaning and re-use of reverse osmosis membranes in desalination plants", which belongs to the CENIT-Tecoagua research project, funded by the Spanish Ministry of Science and Innovation. The authors would like to gratefully acknowledge Vicente Fornes and Rosa Torrero from the CSIC-I.T.Q research centre from the Universitat Politecnica de Valencia for their support given in the ATR-FTIR analysis.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Static cleaning tests as the first step to optimize RO membranes cleaning procedure

  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
  • Alvarez Blanco, Silvia
  • Sancho, M.|||0000-0002-9566-1949
  • Gimenez Anton, Adria Carles
Membrane fouling is an intrinsic problem of membrane technology which affects process performance and causes a substantial rise of the operating costs. This becomes central in seawater desalination processes. This study is focused on applying a membrane chemical cleaning protocol to obtain the most adequate cleaning conditions to recover the permselective properties of an irreversibly fouled reverse osmosis membrane from a seawater desalination plant. The research was carried out in three steps: fouling characterization by scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDX), atomic force microscopy, attenuated total reflectance Fourier transform infrared spectroscopy and elemental analysis; static cleaning tests; and characterization of the membrane surface after the cleaning step. The cleaning process was performed in a static way as a preliminary step. Five of the most widely used cleaning agents were tested (NaOH, citric acid, HCl, sodium dodecyl sulfate [SDS], and ethylenediaminetetraacetic acid disodium salt) at a broad range of concentrations and two different temperatures (25 and 40 degrees C). SEM-EDX analysis showed that foulant compounds were mainly silica, iron silicate, and aluminum silicate, which indicated that fouling was mainly colloidal and inorganic. The best cleaning results were achieved by SDS 0.5% w/w at 40 degrees C, as the greatest recovery of the membrane permselective properties (permeability and salt rejection index) was obtained., The authors wish to thank Abengoa Water, S.L. for the financial support given to this research, through the project "Cleaning and re-use of reverse osmosis membranes in desalination plants," which belongs to the CENIT-Tecoagua research project, funded as well by the Spanish Ministry of Science and Innovation. The authors would like to gratefully acknowledge Vicente Fornes and Rosa Torrero from the CSIC-I.T.Q research center from the Universitat Politecnica de Valencia for the support given in the ATR-FTIR analysis.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Study of ultrasonically enhanced chemical cleaning of SWRO membranes at pilot plant scale

  • García-Fayos, Beatriz|||0000-0002-7941-4243
  • Arnal Arnal, José Miguel
  • Alvarez Blanco, Silvia
  • Sancho, M.|||0000-0002-9566-1949
  • Gimenez Anton, Adria Carles
[EN] Fouling accumulated on reverse osmosis (RO) membranes during operation is one of the main problems affecting seawater desalination processes. This phenomenon causes a deterioration of the permselective properties of the membranes, which turns into a loss of performance of the process and costs increase. Conventionally, recovery of the process performance in desalination plants is carried out periodically by means of physical and chemical cleaning stages. However, conventional cleaning does not manage to recover completely the membrane properties and eventually can damage the membrane materials. New membrane cleaning techniques have been developed in order to improve this recovery. Ultrasound (US) radiation, which has shown to be an interesting technique during filtration since it avoids fouling deposition and allows to lengthen the period between cleaning stages, is proposed as an alternative technique to remove membrane fouling. This work investigates the effect of the combination of chemical cleaning methods and US application to clean a RO membrane from a desalination plant. The experiments performed were able to determine the best operating conditions to carry out the US cleaning protocol. Sodium hydroxide 2% w/v and sodium dodecyl sulphate 4% w/v solutions at 25 degrees C were used, as they showed the highest recovery of the membrane properties in the chemical cleaning tests. Results showed that cleaning by US had a positive effect on the membrane selectivity (increase by 15.2%), and a low significant effect on its permeability. The utilization of the chemical cleaning combined with US improved the permeate flux considerably, without modifying salt rejection index in a significant way. Among the two cleaning solutions tested, the best results in terms of permeability and selectivity of the cleaned membrane, were those obtained by the US procedure using NaOH 2% w/v cleaning solution at 25 degrees C., The authors wish to thank Abengoa Water, S.L. for the financial support given to this research, through the project "Cleaning and re-use of reverse osmosis membranes in desalination plants", which belongs to the CENIT-Tecoagua research project, funded as well by the Spanish Ministry of Science and Innovation.