Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

An on-chip microfluidic-based electrochemical magneto-immunoassay for procalcitonin determination in plasma from sepsis diagnosed preterm neonates

  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Molinero Fernández, Águeda
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
A novel on-chip electrochemical magneto-immunoassay for Procalcitonin (PCT) determination is proposed. The strategy implies the on-line performing of the biorecognition event and the detection onto thin film microfluidic gold electrodes chamber operating at E= ?0.20 V (vs Au). The complete assay was performed in less than 15 minutes using only 25 ?L of sample, covering the entire spectrum of relevant clinically PCT concentrations in sepsis diagnosis and with a limit of detection and quantification of 0.02 ng/mL and 0.05 ng/mL, respectively (sepsis diagnosis threshold: 0.5 ng/mL). The onchip electrochemical magneto-immunoassay provided excellent results in the analysis of very unique samples coming from preterm neonates with sepsis suspicion, in which sample volume is hardly available. These characteristics fulfill the POCT requirements for PCT determination in the whole relevant clinical concentrations. Because of the high clinical relevance and the important role of PCT in sepsis, this approach opens new perspectives for the sepsis diagnosis and therapy guidance using low volume samples., La Caixa, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis

  • Molinero Fernández, Águeda
  • Moreno Guzmán, María
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Procalcitonin (PCT) is a known protein biomarker clinically used for the early stages of sepsis diagnosis and therapy guidance. For its reliable determination, sandwich format magnetic bead-based immunoassays with two di erent electrochemical detection approaches are described: (i) disposable screen-printed carbon electrodes (SPE-C, on-drop detection); (ii) electro-kinetically driven microfluidic chips with integrated Au electrodes (EMC-Au, on-chip detection). Both approaches exhibited enough sensitivity (limit of detection (LOD) of 0.1 and 0.04 ng mL?1 for SPE-C and EMC-Au, respectively; cuto 0.5 ng mL?1), an adequate working range for the clinically relevant concentrations (0.5?1000 and 0.1?20 ng mL?1 for SPE-C and EMC-Au, respectively), and good precision (RSD < 9%), using low sample volumes (25 L) with total assay times less than 20 min. The suitability of both approaches was successfully demonstrated by the analysis of human serum and plasma samples, for which good recoveries were obtained (89?120%). Furthermore, the EMC-Au approach enabled the easy automation of the process, constituting a reliable alternative diagnostic tool for on-site/bed-site clinical analysis., La Caixa, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Electrochemical Microfluidic Micromotors-Based Immunoassay for C-Reactive Protein Determination in Preterm Neonatal Samples with Sepsis Suspicion

  • Molinero Fernández, Águeda
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Online coupling of a micromotor-based immunoassay and a microfluidic electrochemical detection was explored as a new approach for C-reactive protein (CRP) determination in serum and preterm neonatal plasma samples with sepsis suspicion. The approach combines the advantages of micromotors (self-fluid mixing capabilities leading to a faster assay in low sample olumes) and electrochemical microfluidic (flow-controlled ultraminiaturized electrochemical detection, high sensitivity, and low-cost) technologies. Both technologies elegantly meet the point of care testing or bed side device requirements such as low analysis times, miniaturization and simplification, and single use. Anti-CRP functionalized micromotors (anti-CRP-rGO(reduced graphene oxide)/Ni/PtNPs (platinum nanoparticles))-based immunoassay coupled to thin layer Au-based electrochemical microfluidics operating at ?0.20 V under controlled fluidic detection operations (30 ?L min?1) allowed the sensitive (LOD = 0.54 ?g/mL) and accurate CRP determination using very low volume preterm neonatal clinical samples (<10 ?L) in just 8 min of total assay time. These excellent analytical characteristics obtained linked to the full automatization of the immunoassay allowed the fast and accurate determination of CRP in hardly available clinical samples as those coming from preterm infants with suspected sepsis. These results demonstrated the usefulness of the approach which meets the clinical requirements as a future point-of-care device for clinical analysis., Ministerio de Economía y Competitividad, Comunidad Autónoma de Madrid, Fundación “La Caixa”