Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Design, Calibration, and Evaluation of a Long-Range 3-D Infrared Positioning System Based on Encoding Techniques

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
Optical indoor positioning systems have experienced an increasing research interest during last years as they can provide 3D centimeter accuracy using LED lighting. In the case of having several LEDs emitting simultaneously and a receiver (e.g. the tag to be localized), these systems face important challenges, such as very high dynamic ranges with low Signal-to-Noise Ratios when the coverage area is increased, Multiple Access Interference (MAI), multipath and near-far effects, calibration issues (misalignments in the receiver and other intrinsic parameters), and so on. Previous work have already shown the feasibility of using LED emitters in combination with Quadrature Angular Diversity Aperture (QADA) receivers to implement positioning systems. This work further introduces new design considerations, tested on an experimental setup, to enlarge the emitter-receiver range, thus increasing the total coverage, while dealing with the aforementioned challenges. The system applies encoding techniques to each transmitter to solve the multiple access problem. The performance of two different types of codes has been compared, as well as their influence on the final estimation of the receiver?s position: one based on Kasami sequences and another based on Loosely Synchronous (LS) codes, derived from Complementary Sets of Sequences. At the receiver, the estimation of the incident point is constrained to angles at which the system can be linearized, and a specific calibration process for this type of sensor has also been defined and applied. The proposal has been finally validated with both, simulated and experimental results, in a large space of 2 2m2 (base), with a distance from transmitters to receiver of 3:4m (height). The experimental tests at distances up to 4 m, carried out after the calibration process, achieve average absolute errors bellow 10 cm for X and Y axis and around 20 cm for Z, and standard deviations below 4 cm for X and Y , and around 30 cm for Z., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

LOCATE-US: Indoor Positioning for Mobile Devices Using Encoded Ultrasonic Signals, Inertial Sensors and Graph- Matching

  • Gualda Gómez, David|||0000-0003-2071-6260
  • Pérez Rubio, María Del Carmen|||0000-0001-8271-6843
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Pérez Bachiller, Sergio
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • García Domínguez, Juan Jesús|||0000-0002-7121-8651
  • Jiménez Martín, Ana|||0000-0003-0713-0054
Indoor positioning remains a challenge and, despite much research and development carried out in the last decade, there is still no standard as with the Global Navigation Satellite Systems (GNSS) outdoors. This paper presents an indoor positioning system called LOCATE-US with adjustable granularity for use with commercial mobile devices, such as smartphones or tablets. LOCATE-US is privacy-oriented and allows every device to compute its own position by fusing ultrasonic, inertial sensor measurements and map information. Ultrasonic Local Positioning Systems (ULPS) based on encoded signals are placed in critical zones that require an accuracy below a few decimeters to correct the accumulated drift errors of the inertial measurements. These systems are well suited to work at room level as walls confine acoustic waves inside. To avoid audible artifacts, the U-LPS emission is set at 41.67 kHz, and an ultrasonic acquisition module with reduced dimensions is attached to the mobile device through the USB port to capture signals. Processing in the mobile device involves an improved Time Differences of Arrival (TDOA) estimation that is fused with the measurements from an external inertial sensor to obtain real-time location and trajectory display at a 10 Hz rate. Graph-matching has also been included, considering available prior knowledge about the navigation scenario. This kind of device is an adequate platform for Location-Based Services (LBS), enabling applications such as augmented reality, guiding applications, or people monitoring and assistance. The system architecture can easily incorporate new sensors in the future, such as UWB, RFiD or others., Universidad de Alcalá, Junta de Comunidades de Castilla-La Mancha, Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Evaluation of Multi-Sensor Fusion Methods for Ultrasonic Indoor Positioning

  • Mannay, Khaoula
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Machhout, Mohamed
  • Aguili, Taoufik
Indoor positioning systems have become a feasible solution for the current development of multiple location-based services and applications. They often consist of deploying a certain set of beacons in the environment to create a coverage volume, wherein some receivers, such as robots, drones or smart devices, can move while estimating their own position. Their final accuracy and performance mainly depend on several factors: the workspace size and its nature, the technologies involved (Wi-Fi, ultrasound, light, RF), etc. This work evaluates a 3D ultrasonic local positioning system (3D-ULPS) based on three independent ULPSs installed at specific positions to cover almost all the workspace and position mobile ultrasonic receivers in the environment. Because the proposal deals with numerous ultrasonic emitters, it is possible to determine different time differences of arrival (TDOA) between them and the receiver. In that context, the selection of a suitable fusion method to merge all this information into a final position estimate is a key aspect of the proposal. A linear Kalman filter (LKF) and an adaptive Kalman filter (AKF) are proposed in that regard for a loosely coupled approach, where the positions obtained from each ULPS are merged together. On the other hand, as a tightly coupled method, an extended Kalman filter (EKF) is also applied to merge the raw measurements from all the ULPSs into a final position estimate. Simulations and experimental tests were carried out and validated both approaches, thus providing average errors in the centimetre range for the EKF version, in contrast to errors up to the meter range from the independent (not merged) ULPSs., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Design of a complete simulator for underwater acoustic localization systems based on spread-spectrum signals

  • Murano, Santiago Emmanuel Francis
  • Pérez Rubio, María Del Carmen|||0000-0001-8271-6843
  • Aparicio Sosa, Joaquín
  • Gualda Gómez, David|||0000-0003-2071-6260
  • Vicente Ranera, Jorge De
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
Deploying prototype positioning systems in underwater environments is expensive and an especially challenging task, so a first common approach is to carry out simulated studies to evaluate the requirements and restrictions imposed by the environment. In this regard, it is helpful to have simulation models that allow the generation of a wide range of tests as a previous step to any experimental prototype implementation. For that purpose, this work focuses on the design of a simulation tool that facilitates research on underwater positioning systems by considering several parameters and features, such as the design of the signals emitted by the acoustic transducers (encoding techniques, modulation schemes, etc.), the frequency response and location of emitters and hydrophones, the bathymetry of the seabed, and the channel effects on the ultrasonic signal propagation, implemented in a model based on ray tracing for the propagation of acoustic signals. The simulation tool has been validated through a complete set of tests for different configurations and situations, analyzing the signals involved at different processing stages: baseband, modulated signals, received signals, and final estimated positions. This simulation tool is a valuable asset to research different positioning system configurations or to illustrate several concepts in a pedagogical context., Universidad de Alcalá, Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Using Perspective-n-Point Algorithms for a Local Positioning System Based on LEDs and a QADA Receiver

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Pizarro Pérez, Daniel|||0000-0003-0622-4884
  • Moltó Orozco, David|||0000-0002-2790-3758
The research interest on location-based services has increased during the last years ever since 3D centimetre accuracy inside intelligent environments could be confronted with. This work proposes an indoor local positioning system based on LED lighting, transmitted from a set of beacons to a receiver. The receiver is based on a quadrant photodiode angular diversity aperture (QADA) plus an aperture placed over it. This configuration can be modelled as a perspective camera, where the image position of the transmitters can be used to recover the receiver?s 3D pose. This process is known as the perspective-n-point (PnP) problem, which is well known in computer vision and photogrammetry. This work investigates the use of different state-of-the-art PnP algorithms to localize the receiver in a large space of 2 2m2 based on four co-planar transmitters and with a distance from transmitters to receiver up to 3.4 m. Encoding techniques are used to permit the simultaneous emission of all the transmitted signals and their processing in the receiver. In addition, correlation techniques (match filtering) are used to determine the image points projected from each emitter on the QADA. This work uses Monte Carlo simulations to characterize the absolute errors for a grid of test points under noisy measurements, as well as the robustness of the system when varying the 3D location of one transmitter. The IPPE algorithm obtained the best performance in this configuration. The proposal has also been experimentally evaluated in a real setup. The estimation of the receiver's position at three particular points for roll angles of the receiver of g ={0º, 120º, 210º and 300º} using the IPPE algorithm achieves average absolute errors and standard deviations of 4.33 cm, 3.51cm and 28.90 cm; and 1.84 cm, 1.17cm and 19.80cm in the coordinates x, y and z, respectively. These positioning results are in line with those obtained in previous work using triangulation techniques but with the addition that the complete pose of the receiver (x, y, z, a, b, g) is obtained in this proposal., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Detecting relative amplitude of IR signals with active sensors and its application to a positioning system

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Lluva Plaza, Sergio|||0000-0002-0050-2807
  • Pérez Rubio, María del Carmen|||0000-0001-8271-6843
Nowadays, there is an increasing interest in smart systems, e.g., smart metering or smart spaces, for which active sensing plays an important role. In such systems, the sample or environment to be measured is irradiated with a signal (acoustic, infrared, radio‐frequency…) and some of their features are determined from the transmitted or reflected part of the original signal. In this work, infrared (IR) signals are emitted from different sources (four in this case) and received by a unique quadrature angular diversity aperture (QADA) sensor. A code division multiple access (CDMA) technique is used to deal with the simultaneous transmission of all the signals and their separation (depending on the source) at the receiver’s processing stage. Furthermore, the use of correlation techniques allows the receiver to determine the amount of energy received from each transmitter, by quantifying the main correlation peaks. This technique can be used in any system requiring active sensing; in the particular case of the IR positioning system presented here, the relative amplitudes of those peaks are used to determine the central incidence point of the light from each emitter on the QADA. The proposal tackles the typical phenomena, such as distortions caused by the transducer impulse response, the near‐far effect in CDMA‐based systems, multipath transmissions, the correlation degradation from non‐coherent demodulations, etc. Finally, for each emitter, the angle of incidence on the QADA receiveris estimated, assuming that it is on a horizontal plane, although with any rotation on the vertical axis Z. With the estimated angles and the known positions of the LED emitters, the position (x, y, z) of the receiver is determined. The system is validated at different positions in a volume of 3 × 3 × 3.4 m3 obtaining average errors of 7.1, 5.4, and 47.3 cm in the X, Y and Z axes, respectively., Agencia Estatal de Investigación, Universidad de Alcalá, Junta de Comunidades de Castilla-La Mancha
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Simulation tool and online demonstrator for CDMA-based Ultrasonic Indoor Localization Systems

  • Pérez Rubio, María Del Carmen|||0000-0001-8271-6843
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Gualda Gómez, David|||0000-0003-2071-6260
  • Murano, Santiago Emmanuel Francis
  • Vicente Ranera, Jorge De
  • Ciudad Fernández, Francisco
  • Villadangos Carrizo, José Manuel|||0000-0001-5900-0978
  • Nieto Capuchino, Rubén|||0000-0002-8293-9665
This work presents the CODEUS platform, which includes a simulation tool together with an online experimental demonstrator to offer analysis and testing flexibility for researchers and developers in Ultrasonic Indoor Positioning Systems (UIPSs). The simulation platform allows most common encoding techniques and sequences to be tested in a configurable UIPS. It models the signal modulation and processing, the ultrasonic transducers? response, the beacon distribution, the channel propagation effects, the synchronism, and the application of different positioning algorithms. CODEUS provides results and performance analysis for different metrics and at different stages of the signal processing. The UIPS simulation tool is specified by means of the MATLAB© App-Designer environment, which enables the definition of a user-friendly interface. It has also been linked to an online demonstrator that can be managed remotely by means of a website, thus avoiding any hardware requirement or equipment on behalf of researchers. This demonstrator allows the selected transmission schemes, modulation or encoding techniques to be validated in a real UIPS, therefore enabling a fast and easy way of carrying out experimental tests in a laboratory environment, while avoiding the time-consuming tasks related to electronic design and prototyping in the UIPS field. Both simulator and online demonstrator are freely available for researchers and students through the corresponding website., Universidad de Alcalá, Agencia Estatal de Investigación