Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

High-resolution versus conventional manometry for the diagnosis of small bowel motor dysfunction

  • Alcalá González, Luis Gerardo|||0000-0003-3247-1539
  • Nieto Ruiz, Adoración|||0000-0002-3421-2840
  • Accarino, Ana María|||0000-0002-5829-1811
  • Azpiroz Vidaur, Fernando|||0000-0002-7327-960X
  • Malagelada Prats, Carolina|||0000-0001-7097-1492
Background: The diagnosis of small bowel motility disorders is performed by manometric evaluation of the contractile patterns of the small intestine. Conventional intestinal manometry systems include few pressure sensors at relatively long intervals. We have recently shown that high-resolution jejunal manometry, with multiple closely spaced recording sites, allows the analysis of propagation patterns of intestinal motility in healthy subjects that cannot be detected with conventional manometry. The objective of this pilot study was to explore the feasibility and diagnostic value of high-resolution intestinal manometry in patients with suspected small bowel dysmotility. Methods: Prospective pilot study evaluating intestinal motility patterns in 16 consecutive patients (16-61 years; 11 women) with severe, chronic digestive symptoms referred for the evaluation of intestinal motility and in 18 healthy controls (21-38 years; 8 women). A 36-channel high-resolution manometry catheter was orally placed under radiological guidance in the jejunum. Intestinal motility was continuously recorded for 3 h fasting and 2 h after a 450 kcal meal. The manometric recordings were analyzed in two formats: (a) with the high-resolution data from 34 channels and (b) showing only the recordings from 5 channels separated by 7 cm intervals, mimicking a conventional manometry recording. Key Results: In the analysis mimicking conventional manometry, abnormal motility criteria were detected in six patients and in no healthy subject [bursts (n = 3), postprandial minute rhythm (n = 1) and myopathic pattern (n = 2)]. These classical dysmotility criteria were also detected by high-resolution manometry. High-resolution analysis detected one or more abnormal findings in seven additional patients that were not observed in any healthy subject, specifically: (a) abnormal propagation of Phase III (n = 3); (b) reduced propagated activity during Fasting Phase II (n = 4); (c) increased propagated activity during Fasting Phase II and postprandial phase (n = 1). Conclusions and Inferences: This pilot study suggests that high-resolution intestinal manometry may improve the sensitivity of conventional manometry in the detection of intestinal motor dysfunction.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

High-resolution versus conventional manometry for the diagnosis of small bowel motor dysfunction

  • Alcalá-González, Luis Gerardo
  • Nieto Ruiz, Adoración
  • Accarino, Anna
  • Azpiroz, Fernando
  • Malagelada, Carolina
Intestinal dysmotility; Pseudo‐obstruction; Small bowel manometry, Dismotilitat intestinal; Pseudo-obstrucció; Manometria de l'intestí prim, Dismotilidad intestinal; Pseudo-obstrucción; Manometría del intestino delgado, Background The diagnosis of small bowel motility disorders is performed by manometric evaluation of the contractile patterns of the small intestine. Conventional intestinal manometry systems include few pressure sensors at relatively long intervals. We have recently shown that high-resolution jejunal manometry, with multiple closely spaced recording sites, allows the analysis of propagation patterns of intestinal motility in healthy subjects that cannot be detected with conventional manometry. The objective of this pilot study was to explore the feasibility and diagnostic value of high-resolution intestinal manometry in patients with suspected small bowel dysmotility. Methods Prospective pilot study evaluating intestinal motility patterns in 16 consecutive patients (16–61 years; 11 women) with severe, chronic digestive symptoms referred for the evaluation of intestinal motility and in 18 healthy controls (21–38 years; 8 women). A 36-channel high-resolution manometry catheter was orally placed under radiological guidance in the jejunum. Intestinal motility was continuously recorded for 3 h fasting and 2 h after a 450 kcal meal. The manometric recordings were analyzed in two formats: (a) with the high-resolution data from 34 channels and (b) showing only the recordings from 5 channels separated by 7 cm intervals, mimicking a conventional manometry recording. Key Results In the analysis mimicking conventional manometry, abnormal motility criteria were detected in six patients and in no healthy subject [bursts (n = 3), postprandial minute rhythm (n = 1) and myopathic pattern (n = 2)]. These classical dysmotility criteria were also detected by high-resolution manometry. High-resolution analysis detected one or more abnormal findings in seven additional patients that were not observed in any healthy subject, specifically: (a) abnormal propagation of Phase III (n = 3); (b) reduced propagated activity during Fasting Phase II (n = 4); (c) increased propagated activity during Fasting Phase II and postprandial phase (n = 1). Conclusions and Inferences This pilot study suggests that high-resolution intestinal manometry may improve the sensitivity of conventional manometry in the detection of intestinal motor dysfunction., This work was supported by the Instituto de Salud Carlos III and co-financed by the European Union (FEDER/FSE) [PI17/01794]; Ministerio de Ciencia e Innovación (Agencia Estatal de Investigación, PID2021-122295OB-I00); Ciberehd is funded by the Instituto de Salud Carlos III. LA was supported by a scholarship from the Instituto de Salud Carlos III (CM20/00182).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Propagation patterns of jejunal motor activity measured by high-resolution water-perfused manometry

  • Alcalá González, Luis Gerardo|||0000-0003-3247-1539
  • Malagelada Prats, Carolina|||0000-0001-7097-1492
  • Galán Hidalgo, Carmen|||0000-0002-9906-2441
  • Nieto Ruiz, Adoración|||0000-0002-3421-2840
  • Accarino, Ana María|||0000-0002-5829-1811
  • Azpiroz Vidaur, Fernando|||0000-0002-7327-960X
Background: The manometric diagnosis of severe intestinal dysmotility is performed at most institutions using catheters with 2-8 sensors 5-10 cm apart. The recent application of high-resolution manometry catheters with closely spaced sensors to other gut segments has been highly successful. The objective of the present study was to determine the feasibility of a jejunal high-resolution manometry method and to carry out a descriptive analysis of normal jejunal motor function. Methods: A 36-channel high-resolution water-perfused manometry catheter (MMS-Laborie, Enschede, The Netherlands) was orally placed in the jejunum of 18 healthy subjects (10 men, eight women; 21-38 age range). Intestinal motility was recorded during 5 h, 3 during fasting, and 2 after a 450 kcal solid-liquid meal. Analysis of motility patterns was supported by computerized tools. Key Results: All healthy subjects except one showed at least one complete migrating motor complex during the 3 h fasting period. Phase III activity lasted 5 ± 1 min and migrated aborally at a velocity of 7 ± 3 cm/min. High-resolution spatial analysis showed that during phase III each individual contraction propagated rapidly (75 ± 37 cm/min) over a 32 ± 10 cm segment of the jejunum. During phase II, most contractile activity corresponded to propagated contractile events which increased in frequency from early to late phase II (0.5 ± 0.9 vs 2.5 ± 1.3 events/10 min, respectively; p < 0.001). After meal ingestion, non-propagated activity increased, whereas propagated events were less frequent than during late phase II. Conclusions & Inferences: Jejunal motility analysis with high-resolution manometry identifies propagated contractile patterns which are not apparent with conventional manometric catheters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Effect of colonic distension on small bowel motility measured by jejunal high-resolution manometry

  • Alcalá González, Luis Gerardo|||0000-0003-3247-1539
  • Malagelada Prats, Carolina|||0000-0001-7097-1492
  • Livovsky, Dan M.|||0000-0002-8212-9638
  • Azpiroz Vidaur, Fernando|||0000-0002-7327-960X
Background: Abnormal motility patterns in the jejunum can be detected in patients with prominent colonic content, and these abnormalities may be due to either a primary jejunal dysfunction or a reflex distortion. The objective of the present study was to determine the effect of colonic distension on small bowel postprandial motility using high-resolution manometry. Methods: Single center, controlled, parallel, randomized, single blind study in healthy subjects testing the effect of colonic filling vs sham infusion on the responses to a meal in 16 healthy subjects. Nutrients were continuously infused in the proximal jejunum (2 Kcal/min) during the 2-h study period to induce a steady-state postprandial motor pattern. Jejunal motility was measured by water-perfused, high-resolution manometry. After 1 h postprandial recording (basal period), gas was infused during 7.5 min via a rectal tube (720 mL or sham infusion), and jejunal motility was recorded for another hour. Key Results: Jejunal postprandial motility during the basal period was characterized by two overlapping components: a) continuous segmental activity (non-propagated or shortly propagated) and b) intercurrent propagated fronts (3.8 ± 1.1 fronts of 2-5 clustered contractions/h.
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

High-resolution versus conventional manometry for the diagnosis of small bowel motor dysfunction

  • Alcalá-González, Luis Gerardo
  • Nieto Ruiz, Adoración
  • Accarino, Anna
  • Azpiroz, Fernando
  • Malagelada, Carolina
Intestinal dysmotility; Pseudo‐obstruction; Small bowel manometry, Dismotilitat intestinal; Pseudo-obstrucció; Manometria de l'intestí prim, Dismotilidad intestinal; Pseudo-obstrucción; Manometría del intestino delgado, Background The diagnosis of small bowel motility disorders is performed by manometric evaluation of the contractile patterns of the small intestine. Conventional intestinal manometry systems include few pressure sensors at relatively long intervals. We have recently shown that high-resolution jejunal manometry, with multiple closely spaced recording sites, allows the analysis of propagation patterns of intestinal motility in healthy subjects that cannot be detected with conventional manometry. The objective of this pilot study was to explore the feasibility and diagnostic value of high-resolution intestinal manometry in patients with suspected small bowel dysmotility. Methods Prospective pilot study evaluating intestinal motility patterns in 16 consecutive patients (16–61 years; 11 women) with severe, chronic digestive symptoms referred for the evaluation of intestinal motility and in 18 healthy controls (21–38 years; 8 women). A 36-channel high-resolution manometry catheter was orally placed under radiological guidance in the jejunum. Intestinal motility was continuously recorded for 3 h fasting and 2 h after a 450 kcal meal. The manometric recordings were analyzed in two formats: (a) with the high-resolution data from 34 channels and (b) showing only the recordings from 5 channels separated by 7 cm intervals, mimicking a conventional manometry recording. Key Results In the analysis mimicking conventional manometry, abnormal motility criteria were detected in six patients and in no healthy subject [bursts (n = 3), postprandial minute rhythm (n = 1) and myopathic pattern (n = 2)]. These classical dysmotility criteria were also detected by high-resolution manometry. High-resolution analysis detected one or more abnormal findings in seven additional patients that were not observed in any healthy subject, specifically: (a) abnormal propagation of Phase III (n = 3); (b) reduced propagated activity during Fasting Phase II (n = 4); (c) increased propagated activity during Fasting Phase II and postprandial phase (n = 1). Conclusions and Inferences This pilot study suggests that high-resolution intestinal manometry may improve the sensitivity of conventional manometry in the detection of intestinal motor dysfunction., This work was supported by the Instituto de Salud Carlos III and co-financed by the European Union (FEDER/FSE) [PI17/01794]; Ministerio de Ciencia e Innovación (Agencia Estatal de Investigación, PID2021-122295OB-I00); Ciberehd is funded by the Instituto de Salud Carlos III. LA was supported by a scholarship from the Instituto de Salud Carlos III (CM20/00182).