Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Magnetic Bead Handling Using a Paper-Based Device for Quantitative Point-of-Care Testing

  • Arias Alpizar, Kevin Ricardo
  • Sánchez Cano, Ana
  • Prat Trunas, Judit
  • Sulleiro Igual, Elena
  • Bosch Nicolau, Pau
  • Oliveira Souto, Ines Mercedes
  • Baldrich Rubio, Eva
  • Molina Romero, Israel
  • Salvador Velez, Fernando M
  • Sánchez Montalvá, Adrián
Low-cost assay automation; Malaria quantitative diagnosis; Smartphone colorimetric detection, Automatització d'assaigs de baix cost; Diagnòstic quantitatiu de la malària; Detecció colorimètrica del telèfon intel·ligent, Automatización de ensayos de bajo costo; Diagnóstico cuantitativo de la malaria; Detección colorimétrica de teléfono inteligente, Microfluidic paper-based analytical devices (μPADs) have been extensively proposed as ideal tools for point-of-care (POC) testing with minimal user training and technical requirements. However, most μPADs use dried bioreagents, which complicate production, reduce device reproducibility and stability, and require transport and storage under temperature and humidity-controlled conditions. In this work, we propose a μPAD produced using an affordable craft-cutter and stored at room temperature, which is used to partially automate a single-step colorimetric magneto-immunoassay. As a proof-of-concept, the μPAD has been applied to the quantitative detection of Plasmodium falciparum lactate dehydrogenase (Pf-LDH), a biomarker of malaria infection. In this system, detection is based on a single-step magneto-immunoassay that consists of a single 5-min incubation of the lysed blood sample with immuno-modified magnetic beads (MB), detection antibody, and an enzymatic signal amplifier (Poly-HRP). This mixture is then transferred to a single-piece paper device where, after on-chip MB magnetic concentration and washing, signal generation is achieved by adding a chromogenic enzyme substrate. The colorimetric readout is achieved by the naked eye or using a smartphone camera and free software for image analysis. This μPAD afforded quantitative Pf-LDH detection in <15 min, with a detection limit of 6.25 ng mL−1 when the result was interpreted by the naked eye and 1.4 ng mL−1 when analysed using the smartphone imaging system. Moreover, the study of a battery of clinical samples revealed concentrations of Pf-LDH that correlated with those provided by the reference ELISA and with better sensitivity than a commercial rapid diagnostic test (RDT). These results demonstrate that magneto-immunoassays can be partly automated by employing a μPAD, achieving a level of handling that approaches the requirements of POC testing., This research was funded by Fondo de Investigaciones Sanitarias of Instituto de Salud Carlos III (co-funded by the European Regional Development Fund; grants CPII18/00025, IFI18/00020, JR18/00022 and QUPID EuroNanoMed AC21_2/00021) and La Caixa Foundation (ID 100010434, fellowship LCF/BQ/DI18/11660061). Diagnostic Nanotools is a consolidated group supported by Secretaria d’Universitats i Recerca, Generalitat de Catalunya (2017 SGR 240).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Smartphone-Enabled Personalized Diagnostics: Current Status and Future Prospects

  • Merazzo, Karla Jaimes
  • Totoricaguena-Gorriño, Joseba
  • Fernández-Martín, Eduardo
  • del Campo, F. Javier
  • Baldrich Rubio, Eva
Biosensors; Mètodes moleculars; Diagnòstics basat en telèfons intel·ligents, Biosensores; Métodos moleculares; Diagnósticos basados en teléfonos inteligentes, Biosensors; Molecular methods; Smarthphone-based diagnostics, Smartphones are becoming increasingly versatile thanks to the wide variety of sensor and actuator systems packed in them. Mobile devices today go well beyond their original purpose as communication devices, and this enables important new applications, ranging from augmented reality to the Internet of Things. Personalized diagnostics is one of the areas where mobile devices can have the greatest impact. Hitherto, the camera and communication abilities of these devices have been barely exploited for point of care (POC) purposes. This short review covers the recent evolution of mobile devices in the area of POC diagnostics and puts forward some ideas that may facilitate the development of more advanced applications and devices in the area of personalized diagnostics. With this purpose, the potential exploitation of wireless power and actuation of sensors and biosensors using near field communication (NFC), the use of the screen as a light source for actuation and spectroscopic analysis, using the haptic module to enhance mass transport in micro volumes, and the use of magnetic sensors are discussed., Financial support from the Basque Government under the ELKARTEK program is also acknowledged. EB is funded by Instituto de Salud Carlos III, cofinanced by the European Regional Development Fund (grant CPII18/00025).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Competitive usb-powered hand-held potentiostat for poc applications, An hrp detection case

  • Montes-Cebrián, Y.
  • Álvarez-Carulla, A.
  • Ruiz-Vega, G.
  • Colomer Farrarons, Jordi|||0000-0001-9537-5363
  • Puig-Vidal, Manuel
  • Baldrich Rubio, Eva|||0000-0003-1393-215X
  • Miribel-Català, P. L.
Considerable efforts are made to develop Point-of-Care (POC) diagnostic tests. POC devices have the potential to match or surpass conventional systems regarding time, accuracy, and cost, and they are significantly easier to operate by or close to the patient. This strongly depends on the availability of miniaturized measurement equipment able to provide a fast and sensitive response. This paper presents a low-cost, portable, miniaturized USB-powered potentiostat for electrochemical analysis, which has been designed, fabricated, characterized, and tested against three forms of high-cost commercial equipment. The portable platform has a final size of 10.5 × 5.8 × 2.5 cm, a weight of 41 g, and an approximate manufacturing cost of
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Smartphone-Enabled Personalized Diagnostics: Current Status and Future Prospects

  • Merazzo, Karla Jaimes
  • Totoricaguena-Gorriño, Joseba
  • Fernández-Martín, Eduardo
  • del Campo, F. Javier
  • Baldrich Rubio, Eva
Biosensors; Mètodes moleculars; Diagnòstics basat en telèfons intel·ligents, Biosensores; Métodos moleculares; Diagnósticos basados en teléfonos inteligentes, Biosensors; Molecular methods; Smarthphone-based diagnostics, Smartphones are becoming increasingly versatile thanks to the wide variety of sensor and actuator systems packed in them. Mobile devices today go well beyond their original purpose as communication devices, and this enables important new applications, ranging from augmented reality to the Internet of Things. Personalized diagnostics is one of the areas where mobile devices can have the greatest impact. Hitherto, the camera and communication abilities of these devices have been barely exploited for point of care (POC) purposes. This short review covers the recent evolution of mobile devices in the area of POC diagnostics and puts forward some ideas that may facilitate the development of more advanced applications and devices in the area of personalized diagnostics. With this purpose, the potential exploitation of wireless power and actuation of sensors and biosensors using near field communication (NFC), the use of the screen as a light source for actuation and spectroscopic analysis, using the haptic module to enhance mass transport in micro volumes, and the use of magnetic sensors are discussed., Financial support from the Basque Government under the ELKARTEK program is also acknowledged. EB is funded by Instituto de Salud Carlos III, cofinanced by the European Regional Development Fund (grant CPII18/00025).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Magnetic Bead Handling Using a Paper-Based Device for Quantitative Point-of-Care Testing

  • Arias Alpizar, Kevin Ricardo
  • Sánchez Cano, Ana
  • Prat Trunas, Judit
  • Sulleiro Igual, Elena
  • Bosch Nicolau, Pau
  • Oliveira Souto, Ines Mercedes
  • Baldrich Rubio, Eva
  • Molina Romero, Israel
  • Salvador Velez, Fernando M
  • Sánchez Montalvá, Adrián
Low-cost assay automation; Malaria quantitative diagnosis; Smartphone colorimetric detection, Automatització d'assaigs de baix cost; Diagnòstic quantitatiu de la malària; Detecció colorimètrica del telèfon intel·ligent, Automatización de ensayos de bajo costo; Diagnóstico cuantitativo de la malaria; Detección colorimétrica de teléfono inteligente, Microfluidic paper-based analytical devices (μPADs) have been extensively proposed as ideal tools for point-of-care (POC) testing with minimal user training and technical requirements. However, most μPADs use dried bioreagents, which complicate production, reduce device reproducibility and stability, and require transport and storage under temperature and humidity-controlled conditions. In this work, we propose a μPAD produced using an affordable craft-cutter and stored at room temperature, which is used to partially automate a single-step colorimetric magneto-immunoassay. As a proof-of-concept, the μPAD has been applied to the quantitative detection of Plasmodium falciparum lactate dehydrogenase (Pf-LDH), a biomarker of malaria infection. In this system, detection is based on a single-step magneto-immunoassay that consists of a single 5-min incubation of the lysed blood sample with immuno-modified magnetic beads (MB), detection antibody, and an enzymatic signal amplifier (Poly-HRP). This mixture is then transferred to a single-piece paper device where, after on-chip MB magnetic concentration and washing, signal generation is achieved by adding a chromogenic enzyme substrate. The colorimetric readout is achieved by the naked eye or using a smartphone camera and free software for image analysis. This μPAD afforded quantitative Pf-LDH detection in <15 min, with a detection limit of 6.25 ng mL−1 when the result was interpreted by the naked eye and 1.4 ng mL−1 when analysed using the smartphone imaging system. Moreover, the study of a battery of clinical samples revealed concentrations of Pf-LDH that correlated with those provided by the reference ELISA and with better sensitivity than a commercial rapid diagnostic test (RDT). These results demonstrate that magneto-immunoassays can be partly automated by employing a μPAD, achieving a level of handling that approaches the requirements of POC testing., This research was funded by Fondo de Investigaciones Sanitarias of Instituto de Salud Carlos III (co-funded by the European Regional Development Fund; grants CPII18/00025, IFI18/00020, JR18/00022 and QUPID EuroNanoMed AC21_2/00021) and La Caixa Foundation (ID 100010434, fellowship LCF/BQ/DI18/11660061). Diagnostic Nanotools is a consolidated group supported by Secretaria d’Universitats i Recerca, Generalitat de Catalunya (2017 SGR 240).