Skip to main content

CARE-ECGI - Terapia de resincronización cardiaca basada en imagen electrocardiográfica

CPP2021-008562

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Transferencia de Conocimiento
Call Proyectos en Colaboración Público-Privada
Call year 2021
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre CORIFY CARE S.L.

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Complexity and recurrence of body surface electrocardiograms correlate with estimated reentrant atrial activity using electrocardiographic imaging in atrial fibrillation patients

  • Molero-Alabau, Rubén
  • Meste, Olivier
  • Peeters, Ralf
  • Karel, Joël
  • Bonizzi, Pietro
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background Complexity and signal recurrence metrics obtained from body surface potential mapping (BSPM) allow quantifying atrial fibrillation (AF) substrate complexity. This study aims to correlate electrocardiographic imaging (ECGI) detected reentrant patterns with BSPM-calculated signal complexity and recurrence metrics. Methods BSPM signals were recorded from 28 AF patients (17 male, 11 women, 62.69 +/- 8.09 y.o.), followed by ECGI calculation. Signal complexity and recurrence metrics were computed on BSPM and ECGI signals. Rotors per second and rotor duration were computed on ECGI signals for each atrium and the whole atrial surface. Correlation between BSPM metrics and ECGI reentrant patterns for the entire atrial surface and for left atrium (LA) and right atrium (RA) were analyzed. Results Atrial complexity and recurrence metrics strongly correlated when computed on BSPM and ECGI. Higher sample entropy and relative harmonic energy (RHE) correlated with rotors of short duration. The highest dominant frequency of the ECGI signals did not correlate with the reentrant activity of the ECGI. Higher short- and long-term recurrence of BSPM signals correlated with longer duration rotors, particularly for long-term recurrence (r(LA)=0.74 vs. r(RA)=0.42). Only ECGI-based reentrant parameters showed higher LA complexity compared to RA (p < 0.05). Conclusions BSPM metrics strongly correlate with metrics measured on ECGI signals. BSPM metrics indicate a more elevated atrial electro-structural remodeling aligned with more short-duration rotors from ECGI computations. Although BSPM delivers qualitative AF reentry data, ECGI remains essential for identifying regional substrate complexity., This work was supported by: Instituto de Salud Carlos III (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106), Generalitat Valenciana and European Social Fund (ACIF/2020/265, BEFPI/2021/062, CIAICO/2022/020), Agencia Estatal de Investigacion PID2020-119364RB-I00, PID2023-149812OB-I00 and CPP2021-008562 by "European Union NextGenerationEU/PRTR". This research has received funding from the European Institute of Innovation and Technology (EIT) under grant agreement No 220385. This European body receives support from the Horizon 2020 research and innovation programme.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrocardiographic Imaging: A New Tool to Ensure Cardiac Resynchronization During Left Bundle Branch Pacing Implant

  • Pujol-López, Margarida
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Martínez-Pérez, Marta
  • Molero, Ruben
  • Graterol, Freddy R.
  • Guasch, Eduard
  • Tolosana, José M.
  • Mont, Lluís
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Left bundle branch pacing (LBBP) has emerged as an alternative to biventricular pacing for cardiac resynchronization therapy (CRT). The objective is to pursue and ensure resynchronization. However, LBBP capture could fail to achieve adequate resynchronization in some patients, in whom biventricular pacing should be attempted., M.P.-L. is currently funded (2023-2025) through a Rio Hortega contract CM22/00107 [Instituto de Salud Carlos III (ISCIII); Fondo Social Europeo(FSE)]. J.M.T. and M.P.-L. received funding for Project in Conduction System Pacing (FIS PI21/00615) from Instituto de Salud Carlos III (Madrid, Spain). L.M.was funded by a 2021 Support for Research Groups grant from the Catalan government (2021_SGR_01350, SGR21/GENCAT), Catalonia, Spain. J.M.T., L.M.,M.R.-C., M.P.-L., and M.S.G. were funded by "La Marato de TV3 Fundacio", project: 202335 10, Barcelona, Catalonia, Spain. The authors thank the CERCAProgramme/Generalitat de Catalunya for the support to Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS). M.S.G and M.M.-P were funded byEIT Health and H2020 Grant n & zcaron; 230129. R.M. was funded by PTQ2023-012972 and CPP2021-008562 (CARE-ECGI). B.P.-S and M.S.G were supported byPLEC2021-007614 funded by MCIN/AEI/10.13039/501100011033 and EU NextGenerationEU/PRTR. This publication is part of the CPP2021-008562 CARE-ECGIproject -Cardiac resynchronization therapy based on electrocardiographic imaging-, funded by MCIN/AEI/10.13039/501100011033 and by the European Union"NextGenerationEU/PRTR".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Volumetric non-invasive cardiac mapping for accessible global arrhythmia characterization

  • Vicente-Puig, Jorge
  • Chamorro-Servent, Judit
  • Zacur, Ernesto
  • Llorente-Lipe, Ines
  • Martinez-Perez, Marta
  • Reventós-Presmanes, Jana
  • Roca-Luque, Ivo
  • Lluís Mont
  • Atienza, Felipe
  • Hernández-Romero, Ismael
  • Sánchez-Arciniegas, Jorge Patricio
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] BackgroundCardiac arrhythmias are a major cause of morbidity and mortality increasing the risk of stroke, heart failure, and sudden cardiac death. Imageless electrocardiographic Imaging has emerged as an accessible non-invasive alternative for cardiac electrical mapping from body surface potentials. However, conventional electrocardiographic imaging is restricted to epicardial reconstructions, reducing its reliability in accurately identifying arrhythmias arising from deeper myocardial structures. We aim to overcome this limitation by reconstructing three-dimensional cardiac activity.MethodsWe introduce a volumetric formulation, which extends beyond epicardial potential estimation by solving an inverse source problem using Green's functions. This technique enables three-dimensional reconstructions of cardiac activation, improving arrhythmia localization in anatomically complex regions. We evaluate the method on simulated premature ventricular beats and on four patients representing clinical challenges, including a premature ventricular contraction from the right ventricular outflow tract, a left bundle branch block, a ventricular tachycardia, and a Wolff-Parkinson-White. We also assess performance on an open-source dataset for myocardial infarction estimation.ResultsOur results indicate that volumetric electrocardiographic imaging reconstructs three-dimensional activation and enhances the localization of arrhythmia origins, yielding a 59.3% reduction in geodesic error between the estimated and simulated origins compared to surface-only approaches. In patient cases, the recovered activation patterns are consistent with the clinical diagnoses.ConclusionsImageless volumetric electrocardiographic imaging enables non-invasive, accessible, three-dimensional mapping of cardiac activation, addressing a fundamental limitation of surface-restricted methods. This capability may support more accurate pre-procedural planning, may help guide ablation targets, and could refine selection and optimization of cardiac resynchronization therapy candidates., This research has received funding from grants n degrees DIN2022-012606, PTQ2022-012632, PTQ2023-013018, PID2023-149812OB-I00, PID2023-149812OB-I00, PI23/01569, CNS2022-135512, RYC2018-024346-I, CNS2022-135512, CERCA Program (Generalitat de Catalunya), AGAUR (2022 DI 022 and GRC-2021 SGR 00113), UAB PPC2023_575610, CPP2021-008562, CPP2024-011368, CPP2023-01050 funded by MCIN/AEI/10.13039/501100011033, by European Union NextGenerationEU/PRTR and by FEDER, EU. This research has also received funding from the European Institute of Innovation and Technology (EIT) under grant agreement No 250027. This European body receives support from the Horizon 2020 research and innovation programme. Additional support has been received by the Generalitat Valenciana with grant CIAICO/2022/020.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Noninvasive assessment of the ventricular arrhythmogenic substrate using electrocardiographic imaging during sinus rhythm: The NIAVAS study

  • Reventós-Presmanes, Jana
  • Hernández-Romero, Ismael
  • Pecllier-Sendra, B.
  • Guillen-Buisan, E.
  • Serrano-Campaner, J.
  • Invers-Rubio, E.
  • Regany-Closa, M.
  • Garre, Paz
  • Borras, Roger
  • Costafreda, Adriana
  • Arbelo, Elena
  • Tolosana, Jose M.
  • Guasch, E.
  • Althoff, Till F.
  • Guichard, Jean-Baptiste
  • Falzone, Pasquale V.
  • Vázquez-Calvo, Sara
  • Elivhots Ayauja
  • Porta-Sanchez, Andreu
  • Roca-Luque, Ivo
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] Background Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) identifies structural properties associated with ventricular tachycardia (VT) but lacks functional information. Noninvasive identification of slow conduction regions using electrocardiographic imaging (ECGI) could complement LGE-CMR to aid VT risk stratification. Objective This study aimed to evaluate the relationship between ventricular arrhythmogenic substrate and regional ECGI markers during sinus rhythm in patients with ischemic cardiomyopathy (ICM). Methods Seventy-two patients were included: 29 with ICM evidenced by LGE-CMR referred for VT ablation, 17 with ICM with implantable cardioverter-defibrillator for primary prevention without documented VT, and 26 controls. ECGI-derived regional activation dispersion (rAD) and pseudo-regional conduction velocity (pseudo-rCV) were analyzed and compared between scarred and healthy regions based on LGE, and between patients with ICM with and without previous VT. In a subgroup with electroanatomic mapping (n = 16), deceleration zones were correlated with ECGI. Results Scarred regions showed higher rAD (46.3 ± 2.2 vs 30.1 ± 1.7 ms, P < .001) and reduced pseudo-rCV (149.9 ± 3.0 vs 165.7 ± 2.4 cm/s, P < .001) than healthy regions. In the subgroup with sinus rhythm electroanatomic mapping, regions containing deceleration zones showed increased rAD (64.9 ± 5.4 vs 43.1 ± 3.1 ms, P < .001), and ECGI identified 70.4% of those zones. At the patient level, the mean of the 3 regions with the highest activation dispersion differentiated patients with ICM with and without previous VT (rAD ¿60.0 ms, sensitivity 75.9%, area under the curve [AUC] 0.75, P = .005) and identified patients with ICM from controls (rAD ¿39.5 ms, AUC 0.93). Conclusion This study introduces a novel regional ECGI methodology demonstrating that rAD identifies abnormalities linked to arrhythmogenic substrate and could help identify patients at risk of VT. These findings highlight ECGI¿s potential as a complementary tool to LGE-CMR., This research was funded by the European Institute of Innovation and Technology (EIT Health) under grant agreement no. 230129. In addition, the research was supported by Ministerio de Ciencia, Innovación y Universidades MCIN/AEI/10.13039/501100011033 (grant PID2023-149812OB-I00), European Union NextGenerationEU/Plan de Recuperación, Transformación y Resiliencia (CNS2022-135512, PTQ2023-013018, and CPP2021- 008562), and Fondo Europeo de Desarrollo Regional European Union (CPP2023-010504). Additional support came from Generalitat Valenciana and European Social Fund Investing in Your Future (grants CIAPOS/2021/238 and CIAICO/2022/020), Instituto de Salud Carlos III (grant CIBERCV16 CB16/11/00354), and Catalonia, Spain (grants 2021_SGR_01350 and SGR21/GENCAT).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

DYNAMO Framework: Advancing non-invasive, rapid calibration in cardiac digital twin technology

  • Herrero-Martín, Clara|||0000-0001-5053-296X
  • Sánchez-Arciniegas, Jorge Patricio
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
  • Molero, Rubén
  • Reventós-Presmanes, Jana
  • Guichard, Jean-Baptiste
  • Althoff, Till
  • Porta-Sanchez, Andreu
  • Roca-Luque, Ivo
  • Mont, Lluís
  • Hernández-Romero, Ismael
[EN] Introduction: Atrial arrhythmias management remains a significant challenge in cardiac electrophysiology. Cardiac digital twins (CDTs) offer a promising solution for individualized treatment. However, existing models are limited by invasive input requirements or long computational times. This paper introduces DYNAMO, a framework that leverages non-invasive electrocardiographic imaging (ECGI) to create CDTs. Methods: DYNAMO utilizes a reaction-diffusion automata model, reducing computational demands while capturing personalized cardiac dynamics using ECGI data. The calibration process maps ECGI data into CDTs by extracting key parameters for personalization, specifically LATs and conduction velocities. The framework was validated against detailed models and patient data in sinus rhythm (SR) and atrial flutter (AFl), comparing local activation times (LATs) and body surface potential maps (BSPM) for models, and focusing on BSPM for patients. Results: In-silico and clinical validation demonstrated the effectiveness of the framework. CDTs closely replicated cardiac dynamics, with an average LAT difference of 3.8 ms for SR models and 8.03 ms for AFl. For patients, CDTs achieved a high BSPM cross-correlation, with values averaging 0.89 for SR and 0.75 for AFl, and successfully replicated the ablation outcome in an AFl scenario. The framework also demonstrated superior computational efficiency compared to traditional models for equivalent simulations. Conclusions: DYNAMO represents a significant advancement in personalized cardiac health management. Using non-invasive ECGI to create CDTs offers an efficient approach to cardiac modeling. Its capability to simulate treatment strategies holds promise for improving clinical outcomes in atrial arrhythmia management. This study lays the basis for the broader application of ECGI in personalized medicine., This work was supported by the Generalitat Valenciana Grants (ACIF/2021/205, CIBEFP/2022/9, CIAPOS/2021/238, CIGE/2022/02, CIAICO/2022/020) and by ESF Invest in your future. This work was supported by MCIN/AEI/10.13039/501100011033 grants PID2020- 119364RB-I00, RYC2018-024346-I, CNS2022-135512, CPP2021- 008562, PTQ2023-013018, PTQ2023-012972 and by European Union NextGenerationEU/PRTR and by FEDER Fondo Europeo de Desarrollo Regional. This research has received funding from the European Institute of Innovation and Technology (EIT) under grant agreements No 220385 and 250027. This European body receives support from the Horizon 2020 research and innovation programme.