ESTRATEGIA DE AHORRO Y EFICIENCIA ENERGETICA EN PRODUCCION DE FRIO POR COMPRESION CON REFRIGERANTES HFC

CTM2008-06468-C02-01

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2008
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

On-site study of HCFC-22 substitution for HFC non-azeotropic blends (R417A, R422D) on a water chiller of a centralized HVAC system

  • Torrella Alcaraz, Enrique
  • Cabello, R.
  • Sanchez, D.
  • Larumbe, J.A.
  • Llopis, R.
[EN] The European Regulation no 2037/2000 has banned manufacturing HCFC refrigerants from January 1st 2010, although its use is allowed up to 2015 if the fluids come from a recycling process. This situation creates the need for developing new working fluids to replace the HCFC in the refrigeration plants now in operation. Among all the HCFCs the R22 is the most widely used in a wide range of applications, especially in air conditioning. This work presents an on-site experimental study of the R22 replacement by two possible substitutes, the HFC-417A and the HFC-422D, in a water chiller in which the energy performance was evaluated. This chiller is part of the centralized HVAC system of a lecture room building at the Jaume 1 University of Castellon, Spain. This communication compares and analyses main operation parameters of the chiller when operating with each refrigerant in real conditions. (C) 2010 Elsevier B.V. All rights reserved., The authors would like to thank the Technical Office of Projects and Buildings (OTOP) of the Jaume 1 University and the maintenance company AGE VAL for its collaboration with the present work. Furthermore, the authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) for the economic support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

  • Llopis, R.
  • Torrella Alcaraz, Enrique
  • Cabello, R.
  • Sanchez, D.
[EN] The world community has committed to eliminate the HCFC-22 refrigerant to a series of deadlines according to the agreements taken during the 19th Montreal Protocol meeting in September 2007. This phase-out, which is already in progress in European Countries, has been accelerated in Article 5 countries. Refrigerant manufactures offer different drop-in refrigerants to replace R22 in existing equipment by non-ozone depleting substances in order to be able to make full use of the remaining life of the plants or different retrofit refrigerants, the use of which implies modifications to the existing systems. This work aims to contribute to the understanding of the implications of the process of R22 substitution, either with drop-in or retrofitting processes, by presenting a theoretical and experimental analysis of the performance of R22, of two drop-in fluids (R422A, R417B) and a retrofit refrigerant (R404A), in a two-stage vapour compression plant over a wide range of evaporating temperatures for a fixed condensing temperature of 40 C. In this communication the main energy parameters, such as cooling capacity and COP are analysed and discussed., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-CO2-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support for the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Energetic evaluation of an internal heat exchanger in a CO2 transcritical refrigeration plant using experimental data

  • Torrella Alcaraz, Enrique
  • Sanchez, D.
  • Llopis, R.
  • Cabello, R.
[EN] The performance of an Internal Heat Exchanger (IHX) operating in a CO 2 transcritical refrigeration plant is analysed, from an energetic point of view, in this work. The evaluation is based on experimental data by contrasting the performance of the plant working with (44 tests) and without the IHX (46 tests) at the same operating conditions. The experimental evaluation covers three evaporating levels (-5, -10 and -15 °C), at two different gas-cooler outlet temperatures each (31, 34 °C), for a wide range of gas-cooler operating pressures (74.5-105.9 bar). The thermal effectiveness of the IHX is empirically analysed for the different operating conditions in the first part of the paper. Moreover, the relation of its effectiveness with the operating parameters is presented. The second part is devoted to analyse the modification of the energetic performance of the plant caused by the IHX. The results show a maximum increment on cooling capacity of 12%, an increment of the efficiency of the plant up to 12% and a maximum increase on discharge temperature of 10 °C at -15 °C of evaporating temperature. © 2010 Elsevier Ltd and IIR. All rights reserved., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to the present work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Second law analysis of two-stage vapour compression refrigeration plants

  • Torrella Alcaraz, Enrique
  • Llopis, R.
  • Cabello, R.
  • Sanchez, D.
  • Larumbe, J.A.
[EN] This paper describes a Second Law Analysis based on experimental data of a two-stage vapour compression facility driven by a compound compressor for medium and low-capacity refrigeration applications, which operates with the most usual inter-stage configurations (direct liquid injection and subcooler). The experimental analysis is performed for an evaporating temperature range between 36 degrees C and 20 degrees C and for a condensing temperature range between 30 degrees C and 47 degrees C using the refrigerant R-404A. The final results are compared with energy analysis from previous works. Additionally, a new criterion of equivalence between the simple vapour compression cycle and the two-stage compression cycle is given., The authors are indebted to the Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) and to the Spanish Ministry of the Environment and Rural and Marine Affairs (200800050084716) for their economic support to this work.