DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of label-free impedimetric platform based on new conductive polyaniline polymer and three-dimensional interdigitated electrode array for biosensor applications,

  • Voitechovič, E.
  • Bratov, Andrey
  • Abramova, Natalia
  • Razumienė, J.
  • Kirsanov, D.
  • Legin, Andrey
  • Lakshmi, D.
  • Piletsky, S.
  • Whitcombe, M.
  • Ivanova-Mitseva, P. K.
Novel label-free impedimetric platform based on a three-dimensional interdigitated electrode array (3D-IDEA) sensor and new conductive polymer as a transducer for oxidoreductases is introduced. This platform is cost-effective, simple to construct and miniaturize. Monomer of conductive polymer N-(N’,N’-diethyldithiocarbamoylethylamidoethyl) aniline (AnD) was deposited onto 3D-IDEA by chemical polymerisation. It was found that the polymer film resistance depends on the redox-potential of the solution. For the first time polyAnD was used as enzyme immobilisation matrix. Pyrroloquinolinequinone (PQQ) dependent alcohol and glucose dehydrogenases were immobilized on 3D-IDEA covered with polyAnD by two different methods. 3D-IDEA sensors with enzymes, which were immobilised by physisorption on polyAnD layer, showed specific response in the presence of 1 μM of the corresponding substrates. Obtained results revealed that PQQ dependent dehydrogenases can re-oxidize on polyAnD via direct electron transfer (DET) from enzyme active site to the polymer surface. This process can be monitored by methods of electrochemical impedance spectroscopy (EIS) and chronoamperometry. Presented study shows that EIS method gives a useful tool for research of re-oxidation process and interaction of electroactive enzymes with conducting materials giving information required to construct and develop analytical devices., N. Abramova and A. Bratov acknowledge financial support from Spanish Ministry of Science and Innovation (projects AGL2008-05578-C05-05/01; IPT-2011-1055-900000 and CTQ2011-29163-C03-02). E. Voitechovic would like to acknowledge the financial support from St. Petersburg State University PostDoc Grant #12.50.1191.2014 and PhD Student Research Traineeship from the Lithuanian Science Council., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Miniaturized metal oxide pH sensors for bacteria detection

  • Uria, Naroa
  • Abramova, Natalia
  • Bratov, Andrey
  • Muñoz Pascual, Francisco Javier
  • Baldrich, Eva
It is well known that the metabolic activity of some microorganisms results in changes of pH of the culture medium, a phenomenon that can be used for detection and quantification of bacteria. However, conventional glass electrodes that are commonly used for pH measurements are bulky, fragile and expensive, which hinders their application in miniaturized systems and encouraged to the search for alternatives. In this work, two types of metal oxide pH sensors have been tested to detect the metabolic activity of the bacterium Escherichia coli (E. coli). These pH sensors were produced on silicon chips with platinum metal contacts, onto which thin layers of IrOx or Ta2O5 were incorporated by two different methods (electrodeposition and e-beam sputtering, respectively). In order to facilitate measurement in small sample volumes, an Ag/AgCl pseudo-reference was also screen-printed in the chip and was assayed in parallel to an external Ag/AgCl reference electrode. As it is shown, the developed sensors generated results indistinguishable from those provided by a conventional glass pH-electrode but could be operated in significantly smaller sample volumes. After optimization of the detection conditions, the metal oxide sensors are successfully applied for detection of increasing concentrations of viable E. coli, with detection of less than 103 cfu mL−1 in undiluted culture medium in just 5 h., Authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (Project CTQ2014-54553-C3-1-R), and from European Union (Project ENIAC-ED-52 v161210). E.B. is supported by the Miguel Servet Program, funded by the Fondo de Investigaciones Sanitarias of the Instituto de Salud Carlos III (Grant CP13/00052) and co-financed by the European Regional Development Fund (ERDF). This work was partially financially supported by Government of Russian Federation, Grant 074-U01., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Fast determination of viable bacterial cells in milk samples using impedimetric sensor and a novel calibration method

  • Uria, Naroa
  • Moral-Vico, Javier
  • Abramova, Natalia
  • Bratov, Andrey
  • Muñoz Pascual, Francisco Javier
As a first stage toward the development of an impedimetric biosensor to quantify viable bacterial cells, this work defines the relationships between microbial growth and impedance changes associated with acidification of the culture medium. Escherichia coli bacterium was used as a model of a common pathogenic bacterium found in a foodstuff. Impedance was measured at a fix frequency of 10 kHz using interdigitated microelectrodes. Impedance changes were found to depend on the number of microorganisms in a sample. However, as the kinetics greatly depends on the bacterial concentration, it was not possible to obtain a single calibration curve in a wide concentration range at a fixed incubation time. To resolve this, a novel calibration method was proposed by measuring the sensor response at 270 and 390 min of incubation and taking a mean value. Obtained calibration plots were used to determine E. coli in a spiked milk samples. Performed experiments demonstrated the capacity of the method to detect E.coli concentrations in a range between 102 and 106 cfu mL−1 in milk in only 6 hours with 5–12% error margin., Authors acknowledge financial support from Spanish Ministry of Economy and Competitiveness (project CTQ2014-54553-C3-1-R) and European Union (project ENIAC-ED-52 v161210). This work was partially financially supported by Government of Russian Federation, Grant 074-U01., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria

  • Hoyos-Nogués, Mireia
  • Brosel-Oliu, Sergi
  • Abramova, Natalia
  • Muñoz Pascual, Francisco Javier
  • Bratov, Andrey
  • Mas-Moruno, Carlos
  • Gil, Francesc-Xavier
Peri-implantitis, an inflammation caused by biofilm formation, constitutes a major cause of implant failure in dentistry. Thus, the detection of bacteria at the early steps of biofilm growth represents a powerful strategy to prevent implant-related infections. In this regard, antimicrobial peptides (AMPs) can be used as effective biological recognition elements to selectively detect the presence of bacteria. Thus, the aim of the present study was to combine the use of miniaturized and integrated impedimetric transducers and AMPs to obtain biosensors with high sensitivity to monitor bacterial colonization. Streptococcus sanguinis, which is one of the most prevalent strains in the onset of periodontal diseases, was used as a model of oral bacteria. To this end, a potent AMP derived from human lactoferrin was synthesized and covalently immobilized on interdigitated electrode arrays (IDEA). X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS) were employed to optimize and characterize the method of immobilization. Noteworthy, the interaction of Streptococcus sanguinis with AMP-coated sensors provoked significant changes in the impedance spectra, which were univocally associated with the presence of bacteria, proving the feasibility of our method. In this regard, the developed biosensor permits to detect the presence of bacteria at concentrations starting from 101 colony forming units (CFU) mL−1 in KCl and from 102 CFU mL−1 in artificial saliva. Moreover, the system was devoid of cytotoxicity for human fibroblasts. These results indicate that the proposed approach can be effective in the detection of initial stages of biofilm formation, and may be useful in the early prevention and treatment of peri-implantitis., The authors acknowledge financial support from the Spanish Government through projects CTQ2014-54553-C3-1-R and MAT2015-67183-R, cofunded by the European Union through European Regional Development Funds, the Government of Catalonia (SGR2014 01333), the Technical University of Catalonia (fellowship of M.H.) and the European Union (Project ENIAC-ED-52v161210, and FP7-PEOPLE-2012-CIG, REA Grant Agreement No. 321985). This work was partially supported by Government of Russian Federation, Grant 074-U01., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Impedimetric label-free sensor for specific bacteria endotoxin detection by surface charge registration

  • Brosel-Oliu, Sergi
  • Galyamin, Dmitry
  • Abramova, Natalia
  • Muñoz Pascual, Francisco Javier
  • Bratov, Andrey
An impedimetric sensor based on a three dimensional electrode array modified with concanavalin A (Con A) was used for label-free detection of bacterial endotoxin: lipopolysaccharide (LPS) from Escherichia coli. The transducer permits the detection of the surface charge changes due to interaction of immobilized Con A biorecognition element and LPS of E. coli in test solution. The deposition of Con A on the surface was carried out using the layer-by-layer method with polyethyleneimine (PEI) polycation as an initial layer. The sensor surface characterization by means of electrochemical impedance spectroscopy technique allowed registering variations in superficial resistance provoked by surface charge changes and is demonstrated as an effective method to monitor sensor parameters at each modification step as well as to follow Con A – LPS reaction. In order to prevent non-specific adsorption of LPS on PEI covered surface different blocking strategies were tested to achieve the specific response between Con A and LPS. Results obtained in this work clearly show that blocking with bovine serum albumin (BSA) is not sufficient to prevent non-specific interactions of PEI and to ensure the selective biorecognition of LPS by Con A. To achieve more efficient PEI blocking a new method was proposed based on consecutive deposition of Con A-glycogen-Con A layers. Sensors modified with PEI-(Con A-Gly)2-Con A multilayers are shown to be highly sensitive, selective and reproducible. Presented biosensor is able to detect bacterial LPS in a very short detection time (20 min) with 2 μg mL−1 limit of detection, which is much lower than reported for other biosensors with Con A., The authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (project CTQ2014-54553-C3-1-R and S.B.O. fellowship of FPI-MICINN program BES-2015-071250) co-funded by the European Regional Development Fund (Feder) and from the Government of Russian Federation (Grant 074-U01)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Novel impedimetric aptasensor for label-free detection of Escherichia coli O157:H7

  • Brosel-Oliu, Sergi
  • Ferreira, Rubén
  • Uria, Naroa
  • Abramova, Natalia
  • Gargallo, Raimundo
  • Muñoz Pascual, Francisco Javier
  • Bratov, Andrey
Microbial safety of drinking water constitutes a major concern in countries at all levels of economic development. Thus, rapid, sensitive and cost effective methods of pathogenic bacteria detection, like common Escherichia coli O157:H7, which can cause important diseases, are highly required. In this work an impedimetric transducer modified with E. coli specific aptamer is studied. To enhance the sensitivity a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer, in which the electrodes are separated by insulating barriers was used. In this sensor chemical reactions at the surface of the barrier provoke electrical charge redistribution which causes changes in the surface conductivity. A DNA aptamer, which recognizes specifically the outer membrane proteins of the E. coli O157:H7, was selected as the biorecognition moiety. Here we report a novel label-free impedimetric aptasensor for detection and quantification of pathogenic E. coli O157:H7 with a low detection limit, good selectivity and short detection time. The developed sensor shows a linear response (R2 = 0.977), proportional to the logarithm of bacterial concentration present in the sample, with the limit of detection (LOD) of about 102 cfu mL−1. No response of the aptasensor was registered in the presence of other bacterial strains (E. coli k12, Salmonella typhimurium, Staphylococcus aureus), which confirms the selectivity of the suggested detection method. Additionally, the methodology of the aptasensor regeneration was developed, so that the detection may be performed several times with the same sensor. Moreover, suitability of the aptasensor for bacteria detection in real samples was demonstrated with a new approach involving bacteria pre-concentration., The authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (project CTQ2014-54553-C3-1-R, CTQ2015-66254-C2-2-P and S.B.O fellowship of FPI-MICINN program BES-2015-071250) co-funded by the European Regional Development Fund (Feder) and from the Government of Russian Federation (Grant 074-U01). N.U. acknowledges funding from the People Programme (Marie Curie Actions) of the 7th Framework Programme of the European Union (FP7/2007-2013), TECNIOspring program from the Agency for Business Competitiveness of the Government of Catalonia (ACCIÓ)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of an integrated method of concentrationand immunodetection of bacteria

  • Ezenarro, Josune J.
  • Uria, Naroa
  • Castillo-Fernandez, Óscar
  • Párraga-Niño, Noemí
  • Sabrià, Miquel
  • Muñoz Pascual, Francisco Javier
The microbial quality of water is a key aspect to avoid environmental and public health problems. The low pathogen concentration needed to produce a disease outbreak makes it essential to process large water volumes and use sensitive and specific methods such as immunoassays for its detection. In the present work, we describe the development of a device based on microfiltration membranes to integrate the concentration and the immunodetection of waterborne bacteria. A microfiltration membrane treatment protocol was designed to reduce the non-specific binding of antibodies, for which different blocking agents were tested. Thus, the proof of concept of the microbial detection system was also carried out using Escherichia coli as the bacterial pathogen model. E. coli suspensions were filtered through the membranes at 0.5 mL s−1, and the E. coli concentration measurements were made by absorbance, at 620 nm, of the resultant product of the enzymatic reaction among the horseradish peroxidase (HRP) bonded to the antibody, and the substrate 3,3′,5,5′-tetramethylbenzidine (TMB). The results showed that the homemade concentration system together with the developed membrane treatment protocol is able to detect E. coli cells with a limit of detection (LoD) of about 100 CFU in 100 mL., The authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (BACSYS pro- ject CTQ2014-54553-C3-1-R). N.U. and O.C. acknowledge funding from the People Programme (Marie Curie Actions) of the 7th Framework Programme of the E uropean Union (FP7/2007-2013), TECNIO-spring program from the Agency for Business Competitiveness of the Government of Catalonia (ACCIÓ). J.J.E. ac- knowledges financial support from the Catalan Industrial Doctorate pro- gram and Waterologies. S.L. and N.P. acknowledge financial support from Gas Natural Fenosa., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Rapid detection of legionella pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement

  • Ezenarro, Josune J.
  • Párraga-Niño, Noemí
  • Sabrià, Miquel
  • Campo García, Francisco Javier del
  • Muñoz Pascual, Francisco Javier
  • Mas, Jordi
  • Uria, Naroa
Legionella is a pathogenic bacterium, ubiquitous in freshwater environments and able to colonise man-made water systems from which it can be transmitted to humans during outbreaks. The prevention of such outbreaks requires a fast, low cost, automated and often portable detection system. In this work, we present a combination of sample concentration, immunoassay detection, and measurement by chronoamperometry. A nitrocellulose microfiltration membrane is used as support for both the water sample concentration and the Legionella immunodetection. The horseradish peroxidase enzymatic label of the antibodies permits using the redox substrate 3,3′,5,5′-Tetramethylbenzidine to generate current changes proportional to the bacterial concentration present in drinking water. Carbon screen-printed electrodes are employed in the chronoamperometric measurements. Our system reduces the detection time: from the 10 days required by the conventional culture-based methods, to 2–3 h, which could be crucial to avoid outbreaks. Additionally, the system shows a linear response (R2 value of 0.99), being able to detect a range of Legionella concentrations between 101 and 104 cfu·mL−1 with a detection limit (LoD) of 4 cfu·mL−1., The authors acknowledge financial support from the Spanish Ministry of Science, Innovation and University [BACSYS projects CTQ2014-54553-C3-1-R and C3-2R] and [RTI2018-101974-B-C22]. J.J.E. acknowledges financial support from the Catalan Industrial Doctorate program [2017-DI-051] and Waterologies S.L., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

3D impedimetric sensors as a tool for monitoring bacterial response to antibiotics

  • Brosel-Oliu, Sergi
  • Mergel,O
  • Uria, Naroa
  • Abramova, Natalia
  • van Rijn, Patrick
  • Bratov, Andrey
The presence of antimicrobial contaminants like antibiotics in the environment is a major concern because they promote the emergence and the spread of multidrug resistant bacteria. Since the conventional systems for the determination of bacterial susceptibility to antibiotics rely on culturing methods that require long processing times, the implementation of novel strategies is highly required for fast and point-of-care applications. Here the development and characterization of a novel label-free biosensing platform based on a microbial biosensor approach to perform antibiotic detection bioassays in diluted solution is presented. The microbial biosensor is based on a three-dimensional interdigitated electrode array (3D-IDEA) impedimetric transducer with immobilized E. coli bacteria. In 3D-IDEA to increase the sensitivity to superficial impedance changes the electrode digits are separated by insulating barriers. A novel strategy is employed to selectively immobilize bacteria in the spaces over the electrode digits between the barriers, referred to here as trenches, in order to concentrate bacteria, improve the reproducibility of the E. coli immobilization and increase the sensitivity for monitoring bacterial response. For effective attachment of bacteria within the trenches an initial anchoring layer of a highly charged polycation, polyethyleneimine (PEI), was used. To facilitate immobilization of bacteria within the trenches and prevent their deposition on top of the barriers an important novelty is the use of poly(N-isopropylmethacrylamide) p(NIPMAM) microgels working as antifouling agents, deposited on top of the barriers by microcontact printing. The reported microbial biosensor approach allows the bacterial response to ampicillin, a bacteriolytic antibiotic, to be registered by means of impedance variations in a rapid and label-free operation that enables new possibilities in bioassays for toxicity testing., The authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (project CTQ2014-54553-C3-1-R, CTQ2015-66254-C2-2-P and S. B. O fellowship BES-2015-071250). S. B. O. also acknowledges the PhD program in Biotechnology of Universitat Autònoma de Barcelona. O. M. is grateful for financial support from the Alexander von Humboldt Foundation, We acknowledge support of the publication fee by the CSIC Open Access Support Initiative through its Unit of Information Resources for Research (URICI)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria

  • RODRIGUEZ-CONTRERAS, ALEJANDRA
  • Marqués-Calvo, María Soledad
  • Gil, FJ
  • Manero, José María
  • Hoyos-Nogués, Mireia
  • BROSEL, SERGI
  • Abramova, Natalia
  • Muñoz, Francesc-Xavier
  • Bratov, Andrey
  • Mas-Moruno, Carlos
The authors acknowledge financial support from the Spanish Government through projects CTQ2014-54553-C3-1-R and MAT2012–30706, cofunded by the European Union through European Regional Development Funds, the Government of Catalonia (SGR2009 1039), the Technical University of Catalonia (fellowship of M.H.) and the European Union (Project ENIAC-ED-52v161210, and FP7-PEOPLE-2012-CIG, REA Grant Agreement No. 321985). This work was partially supported by Government of Russian Federation, Grant 074-U01., Novel researches are focused on the prevention and management of post-operative infections. To avoid this common complication of implant surgery, it is preferable to use new biomaterials with antibacterial properties. Therefore, the aim of this work is to develop a method of combining the antibacterial properties of antibiotic-loaded poly(3-hydroxybutyrate) (PHB) nano- and micro-spheres and poly(ethylene glycol) (PEG) as an antifouling agent, with titanium (Ti), as the base material for implants, in order to obtain surfaces with antibacterial activity. The Ti surfaces were linked to both PHB particles and PEG by a covalent bond. This attachment was carried out by firstly activating the surfaces with either Oxygen plasma or Sodium hydroxide. Further functionalization of the activated surfaces with different alkoxysilanes allows the reaction with PHB particles and PEG. The study confirms that the Ti surfaces achieved the antibacterial properties by combining the antibiotic-loaded PHB spheres, and PEG as an antifouling agent., info:eu-repo/semantics/acceptedVersion
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid detection of Legionella pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement

  • J. Ezenarro, Josune|||0000-0003-3456-3787
  • Párraga-Niño, Noemí|||0000-0003-0376-5036
  • Sabriá-Leal, M.|||0000-0002-9669-8794
  • del Campo, F. Javier|||0000-0002-3637-5782
  • Muñoz Pascual, Francisco Javier
  • Jordi Mas, Jordi
  • Uría Moltó, Naroa|||0000-0002-6699-2407
Legionella is a pathogenic bacterium, ubiquitous in freshwater environments and able to colonise man-made water systems from which it can be transmitted to humans during outbreaks. The prevention of such outbreaks requires a fast, low cost, automated and often portable detection system. In this work, we present a combination of sample concentration, immunoassay detection, and measurement by chronoamperometry. A nitrocellulose microfiltration membrane is used as support for both the water sample concentration and the Legionella immunodetection. The horseradish peroxidase enzymatic label of the antibodies permits using the redox substrate 3,3',5,5'-Tetramethylbenzidine to generate current changes proportional to the bacterial concentration present in drinking water. Carbon screen-printed electrodes are employed in the chronoamperometric measurements. Our system reduces the detection time: from the 10 days required by the conventional culture-based methods, to 2-3 h, which could be crucial to avoid outbreaks. Additionally, the system shows a linear response (R2 value of 0.99), being able to detect a range of Legionella concentrations between 101 and 104 cfu·mL-1 with a detection limit (LoD) of 4 cfu·mL-1.