Skip to main content

REACTORES ELECTROQUIMICOS MICROBIANOS BASADOS EN ELECTRODOS FLUIDICOS: UNA NUEVA PLATAFORMA PARA APLICACIONES AMBIENTALES

RTI2018-101974-B-C22

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Expanding success in the isolation of abundant marine bacteria after reduction in grazing and viral pressure and increase in nutrient availability

  • Rey Velasco, Xavier|||0000-0002-6970-6234
  • Deulofeu Capo, Ona|||0000-0003-1653-6523
  • Sanz-Sáez, Isabel|||0000-0003-0233-7224
  • Cardelús, Clara
  • Ferrera, Isabel|||0000-0003-3484-516X
  • Gasol, Josep M.|||0000-0001-5238-2387
  • Sánchez Martínez, M. Olga|||0000-0003-1254-012X
Bottom-up and top-down controls greatly influence marine microbial community composition and dynamics, which in turn have effects on their culturability. We isolated a high amount of heterotrophic bacterial strains from experiments where seawater environmental conditions had been manipulated and found that decreasing grazing and viral pressure as well as rising nutrient availability are key factors increasing the success in culturing marine bacteria. Our data hint at factors influencing culturability and underpin bacterial cultures as a powerful way to discover new taxa.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Rapid detection of legionella pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement

  • Ezenarro, Josune J.
  • Párraga-Niño, Noemí
  • Sabrià, Miquel
  • Campo García, Francisco Javier del
  • Muñoz Pascual, Francisco Javier
  • Mas, Jordi
  • Uria, Naroa
Legionella is a pathogenic bacterium, ubiquitous in freshwater environments and able to colonise man-made water systems from which it can be transmitted to humans during outbreaks. The prevention of such outbreaks requires a fast, low cost, automated and often portable detection system. In this work, we present a combination of sample concentration, immunoassay detection, and measurement by chronoamperometry. A nitrocellulose microfiltration membrane is used as support for both the water sample concentration and the Legionella immunodetection. The horseradish peroxidase enzymatic label of the antibodies permits using the redox substrate 3,3′,5,5′-Tetramethylbenzidine to generate current changes proportional to the bacterial concentration present in drinking water. Carbon screen-printed electrodes are employed in the chronoamperometric measurements. Our system reduces the detection time: from the 10 days required by the conventional culture-based methods, to 2–3 h, which could be crucial to avoid outbreaks. Additionally, the system shows a linear response (R2 value of 0.99), being able to detect a range of Legionella concentrations between 101 and 104 cfu·mL−1 with a detection limit (LoD) of 4 cfu·mL−1., The authors acknowledge financial support from the Spanish Ministry of Science, Innovation and University [BACSYS projects CTQ2014-54553-C3-1-R and C3-2R] and [RTI2018-101974-B-C22]. J.J.E. acknowledges financial support from the Catalan Industrial Doctorate program [2017-DI-051] and Waterologies S.L., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Expanding success in the isolation of abundant marine bacteria after reduction in grazing and viral pressure and increase in nutrient availability

  • Rey-Velasco, Xavier
  • Deulofeu, Ona
  • Sanz-Sáez, Isabel
  • Cardelús, Clara
  • Ferrera, Isabel
  • Gasol, Josep M.
  • Sánchez, Olga
21 pages, 6 figures, 1 table.-- Data Availability: All supplemental figures and tables can be found on GitHub (https://github.com/x-rv/Manuscript-2023). The 16S rRNA gene sequences of the isolates obtained in this study were deposited in GenBank under accession numbers OP342842 to OP344484. Amplicon sequencing data of the V4-V5 region of the 16S rRNA gene used in this study are publicly available in the European Nucleotide Archive under BioProject PRJEB60085, Isolation of microorganisms is a useful approach to gathering knowledge about their genomic properties, physiology, and ecology, in addition to allowing the characterization of novel taxa. We performed an extensive isolation effort on samples from seawater manipulation experiments that were carried out during the four astronomical seasons in a coastal site of the northwest Mediterranean to evaluate the impact of grazing, viral mortality, resource competition reduction, and light presence/absence on bacterioplankton growth. Isolates were retrieved using two growth media, and their full 16S rRNA gene was sequenced to assess their identity and calculate their culturability across seasons and experimental conditions. A total of 1,643 isolates were obtained, mainly affiliated to the classes Gammaproteobacteria (44%), Alphaproteobacteria (26%), and Bacteroidia (17%). Isolates pertaining to class Gammaproteobacteria were the most abundant in all experiments, while Bacteroidia were preferentially enriched in the treatments with reduced grazing. Sixty-one isolates had a similarity below 97% to cultured taxa and are thus putatively novel. Comparison of isolate sequences with 16S rRNA gene amplicon sequences from the same samples showed that the percentage of reads corresponding to isolates was 21.4% within the whole data set, with dramatic increases in the summer virus-reduced (71%) and diluted (47%) treatments. In fact, we were able to isolate the top 10 abundant taxa in several experiments and from the whole data set. We also show that top-down and bottom-up controls differentially affect taxa in terms of culturability. Our results indicate that culturing marine bacteria using agar plates can be successful in certain ecological situations, This research was supported by grant RTI2018-101974-B-C22 funded by the Spanish Ministry of Economy and Competitiveness and grants TM2015-70340-R, RTI2018-101025-B-100 and PID2021-125469NB-C32 funded by the Spanish Ministry of Science and Innovation. This work acknowledges the Severo Ochoa Centre of Excellence accreditation (CEX2019-000928-S). Xavier Rey-Velasco was supported by Spanish FI-SDUR and FPU grants, Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid detection of Legionella pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement

  • J. Ezenarro, Josune|||0000-0003-3456-3787
  • Párraga-Niño, Noemí|||0000-0003-0376-5036
  • Sabriá-Leal, M.|||0000-0002-9669-8794
  • del Campo, F. Javier|||0000-0002-3637-5782
  • Muñoz Pascual, Francisco Javier
  • Jordi Mas, Jordi
  • Uría Moltó, Naroa|||0000-0002-6699-2407
Legionella is a pathogenic bacterium, ubiquitous in freshwater environments and able to colonise man-made water systems from which it can be transmitted to humans during outbreaks. The prevention of such outbreaks requires a fast, low cost, automated and often portable detection system. In this work, we present a combination of sample concentration, immunoassay detection, and measurement by chronoamperometry. A nitrocellulose microfiltration membrane is used as support for both the water sample concentration and the Legionella immunodetection. The horseradish peroxidase enzymatic label of the antibodies permits using the redox substrate 3,3',5,5'-Tetramethylbenzidine to generate current changes proportional to the bacterial concentration present in drinking water. Carbon screen-printed electrodes are employed in the chronoamperometric measurements. Our system reduces the detection time: from the 10 days required by the conventional culture-based methods, to 2-3 h, which could be crucial to avoid outbreaks. Additionally, the system shows a linear response (R2 value of 0.99), being able to detect a range of Legionella concentrations between 101 and 104 cfu·mL-1 with a detection limit (LoD) of 4 cfu·mL-1.