Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Docta Complutense
Publication Artículo científico (JournalArticle)

Electrochemical immunosensor for sensitive determination of transforming growth factor (TGF) - β1 in urine

  • Sánchez Tirado, Esther
  • Martínez García, Gonzalo
  • González Cortés, Araceli
  • Yáñez-Sedeño Orive, Paloma
  • Pingarrón Carrazón, José Manuel
The first amperometric immunosensor for the quantification of TGF-β1, a cytokine proposed as a biomarker for patients having or at risk for renal disease, is described in this work. The immunosensor design involves disposable devices using carboxylic acid-functionalized magnetic microparticles supported onto screen-printed carbon electrodes and covalent immobilization of the specific antibody for TGF-β1 using Mix&Go polymer. A sandwich-type immunoassay was performed using biotin-anti-TGF and conjugation with peroxidase-labeled streptavidin (poly-HRP-Strept) polymer. Amperometric measurements were carried out at 0.20 V by adding hydrogen peroxide solution onto the electrode surface in the presence of hydroquinone as the redox mediator. The calibration plot allowed a range of linearity extending between 15 and 3000 pg/mL TGF-β1 which is adequate for the determination of the cytokine in plasma and urine. The limit of detection, 10 pg/mL, is notably improved with respect to those obtained with ELISA kits. The usefulness of the immunosensor for the determination of low TGF-β1 concentrations in real samples was evaluated by analyzing spiked urine at different pg/mL concentration levels.
Docta Complutense
Publication Artículo científico (JournalArticle)

Enzymatic/Immunoassay Dual-Biomarker Sensing Chip: Towards Decentralized Insulin/Glucose Detection

  • Vargas, Eva
  • Teymourian, Hazhir
  • Tehrani, Farshad
  • Eksin, Ece
  • Sánchez Tirado, Esther
  • Warren, Paul
  • Erdem, Arzum
  • Dassau, Eyal
  • Wang, Joseph
Performing bioassay formats based on enzyme and antibody recognition reactions with a single detection chip remains an unmet challenge owing to the different requirements of such bioassays. Herein, we describe a dual-marker biosensor chip, integrating enzyme and antibody-based assays for simultaneous electrochemical measurements of insulin (I) and glucose (G). Simultaneous G/I sensing has been realized by addressing key fabrication and operational challenges associated with the different assay requirements and surface chemistry. The I immunosensor relies on a peroxidase-labeled sandwich immunoassay, while G is monitored through reaction with glucose oxidase. The dual diabetes biomarker chip offers selective and reproducible detection of picomolar I and millimolar G concentrations in a single microliter sample droplet within less than 30 min, including direct measurements in whole blood and saliva samples. The resulting integrated enzymatic-immunoassay biosensor chip opens a new realm in point-of-care multiplexed biomarker detection.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Amperometric determination of endoglin in human serum using disposable immunosensors constructed with poly(pyrrolepropionic) acid-modified electrodes

  • Martínez-Periñán, Emiliano
  • Sánchez-Tirado, E.
  • González-Cortés, Araceli
  • Barderas, Rodrigo
  • Sánchez-Puelles, José María
  • Martínez-Santamaría, Lucía
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
24 p.-6 fig.-2 tab., An amperometric immunosensor for the determination of the biomarker endoglin (CD105) to comply with the requirements of sensitivity and accuracy demanded in clinical practice is reported in this work. The immunosensing platform is implemented onto disposable electrodes modified with poly(pyrrolepropionic) acid (pPPA). The methodology involves a sandwich configuration and labeling of the biotinylated detector antibody with poly-HRP-streptavidin for signal amplification. Amperometric detection of hydrogen peroxide reduction in the presence of HQ was employed as analytical readout. The different steps involved in the immunosensor preparation were monitored by electrochemical impedance spectroscopy. The resulting immunosensor provided a linear range between 0.18 and 20 ng mL-1, adequate for the determination of CD105 in serum, with a detection limit (LOD) of 140 pg mL−1. These analytical characteristics improve those reported previously for other electrochemical immunosensors. A comparison with immunosensors prepared using other electrochemical scaffolds for anti-CD105 immobilization involving carboxylated doubled walled carbon nanotubes or modification by grafting, showed that a better performance was achieved using pPPA-modified SPCEs. A good reproducibility of the measurements, an excellent storage stability of the anti-CD105-pPPA/SPCE bioplatforms and an excellent selectivity of the resulting immunosensors were found. The usefulness of the immunosensors was tested by analyzing human serum samples collected from healthy individuals and patients of colorectal, breast and lung cancer and epidermolysis bullosa. The results were successfully validated against those provided by an ELISA kit., The financial support of the Spanish Ministerio de Economía y Competitividad CTQ2015-70023-R and CTQ2015-64402-C2-1-R, and SAF2014-53209-R Research Projects, the PI17CIII/00045 research project from AESI and the NANOAVANSENS Program from the Comunidad de Madrid (S2013/MT-3029)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comparative evaluation of the performance of electrochemical immunosensors using magnetic microparticles and nanoparticles. Application to the determination of tyrosine kinase receptor AXL

  • Serafín, Verónica
  • Batlle, M.
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
Electrochemical sandwich immunoassay strategies involving the use of carboxyl-functionalized magnetic microbeads (cMBs) and magnetic nanoparticles (cMNPs) have been evaluated and compared. The proteolytically cleaved soluble tyrosine kinase receptor sAXL was used as the target analyte. Antibodies against AXL were covalently immobilized on cMBs or cMNPs. Immunobinding of AXL was detected by means of a secondary biotinylated antibody and a streptavidin-horseradish peroxidase conjugate. The electrochemical transduction was accomplished by capturing the cMBs or cMNPs bearing the immunoconjugates onto screen-printed carbon electrodes (SPCEs) by using a small magnet. The amperometric response was measured at −0.20 V (vs the silver pseudo-reference electrode of the SPCE) upon the addition of H2O2 in the presence of hydroquinone as the redox mediator. The calibration plots for AXL extended up to 7.5 ng mL−1 when cMBs were used for the preparation of the immunosensor and up to 40 ng mL−1 in the case of using cMNPs. The respective slope values were 158 (cMBs) and 43 nA mL ng−1 (cMNPs), while the achieved LODs were 74 (cMBs) and 75 pg mL−1 (cMNPs). Although the immunosensors prepared with cMBs provided a shorter range of linearity, they exhibited a 3.7-times larger sensitivity than those constructed with cMNPs. The successful application of the new strategies was demonstrated for the determination of the endogenous content of sAXL in real human serum samples (a cut-off value of 71 ng mL−1 have been established for patients with risk of heart failure). The immunosensors constructed using cMBs or cMNPs can be advanta geously compared, in terms of sensitivity and fabrication time, with the only immunosensor for AXL previously reported. In addition, these new immunosensors took approximately half time than ELISA to perform the assay., The financial support of projects: Retos Colaboración RTC-2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER Buna manera de hacer Europa^), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/ MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministry of Economy and Competitivity, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electrochemical immunosensor for receptor tyrosine kinase AXL using poly(pyrrolepropionic acid)-modified disposable electrodes

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • Batlle, Montserrat
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
A sensitive and rapid method for the determination of the clinically relevant biomarker receptor tyrosine kinase AXL in serum involving amperometric disposable immunosensors is reported. The target protein was sandwiched between a specific capture antibody covalently immobilized on screen-printed carbon electrodes modified with electropolymerized poly(pyrrolepropionic acid) and a biotinylated detector antibody labeled with a streptavidin-horseradish peroxidase conjugate. The amperometric responses were measured at −0.20 V vs the Ag pseudo-reference electrode of the SPCE upon the addition of H2O2 in the presence of hydroquinone (HQ) as mediator. This integrated immunosensing platform showed a low limit of detection (337 pg mL−1), a good selectivity against other non-target serum proteins, and provided results statistically in agreement with those obtained by using a commercial ELISA kit. These attractive features together with the simplicity and easy automation and miniaturization of the required instrumentation make the developed methodology a promising alternative in the development of devices for on-site clinical analysis., The financial support of projects: Retos Colaboración RTC2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER), CTQ2015-70023-R and CTQ2015- 64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministerio de Economía y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

An electrochemical immunosensor for brain natriuretic peptide prepared with screen-printed carbon electrodes nanostructured with gold nanoparticles grafted through aryl diazonium salt chemistry

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • González-Cortés, Araceli
  • García de Frutos, Pablo
  • Sabaté, Manel
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
A sensitive amperometric immunosensor has been prepared by immobilization of capture antibodies onto gold nanoparticles (AuNPs) grafted on a screen-printed carbon electrode (SPCE) through aryl diazonium salt chemistry using 4-aminothiophenol (AuNPs-S-Phe-SPCE). The immunosensor was designed for the accurate determination of clinically relevant levels of B-type natriuretic peptide (BNP) in human serum samples. The nanostructured electrochemical platform resulted in an ordered layer of AuNPs onto SPCEs which combined the advantages of high conductivity and improved stability of immobilized biomolecules. The resulting disposable immunosensor used a sandwich type immunoassay involving a peroxidase-labeled detector antibody. The amperometric transduction was carried out at −0.20 V (vs the Ag pseudo-reference electrode) upon the addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. The nanostructured immunosensors show a storage stability of at least 25 days, a linear range between 0.014 and 15 ng mL−1, and a LOD of 4 pg mL−1, which is 100 times lower than the established cut-off value for heart failure (HF) diagnosis. The performance of the immunosensor is advantageously compared with that provided with immunosensors prepared by grafting SPCE with p-phenylendiamine (H2N-Phe-SPCE) and attaching AuNPs by immersion into an AuNPs suspension or by electrochemical deposition, as well as with immunosensors constructed using commercial AuNPs-modified SPCEs. The developed immunosensor was applied to the successful analysis of human serum from heart failure (HF) patients upon just a 10-times dilution as sample treatment., The financial support of projects: RetosColaboración RTC-2015- 4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER “una manera de hacer Europa”), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (Spanish Ministry of Economy and Competitivity Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged. R.M. Torrente-Rodríguez acknowledges a predoctoral contract from the Spanish Ministerio de Economía y Competitividad., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Detection of B-type natriuretic peptide (BNP) at screen printed carbon electrodes modified with gold nanoparticles grafted through aryl diazonium salt chemistry

  • Serafín, Verónica
  • Torrente-Rodríguez, Rebeca M.
  • Batlle, Montserrat
  • García de Frutos, Pablo
  • Campuzano, Susana
  • Yáñez-Sedeño, Pilar
  • Pingarrón, José Manuel
Trabajo presentado en la XXI Reunión de la Sociedad Española de Química Analítica, celebrada en Valencia, del 5 al 7 de septiembre de 2017, A key step in the proper functioning of an electrochemical biosensor is the surface architecture connecting the biological sample to the transducer. The type of materials involved, its geometry and size strongly affect the response of the biosensor. Furthermore, gold nanoparticles (AuNPs) have a strong capacity for biomolecules adsorption without losing of biological activity and facilitate the electron transfer between redox biomaterial and the electrode surface. Thus, immobilization of AuNPs on bulk electrodes using covalently attached organic layers containing thiol groups and amino groups on their distal end offers a simple, fast, and versatile approach for preparing nanoparticle electrode arrays with low background capacitance. On the order hand, since the signs and symptoms of heart failure (HF) are not very specific and the availability of echocardiography is limited, a very interesting alternative approach to diagnosis HF is to determine accurately the blood concentration of natriuretic peptides (NPs). Between them, the B-type natriuretic peptide (BNP) is a 32-amino acid polypeptide secreted by the ventricles of the heart in response to excessive stretching of heart muscle cells. Interestingly, it has been found that BNP concentration in serum is elevated in HF patients compared to controls, establishing a cut-off value of 400 pg mL-1 . With the purpose to develop a competitive electrochemical strategy for the accurate determination of clinically relevant levels of BNP in serum samples, in this work, we have prepared a sensitive electrochemical immunosensor for this polypeptide determination based on the immobilization of capture antibodies onto gold nanoparticles grafted through aryl diazonium salt chemistry onto screen-printed carbon electrodes (SPCEs) by means of a sandwich type immunoassay involving a peroxidase-labeled detector antibody. This novel nanostructured platform resulted in an ordered layer of gold nanoparticles adsorbed onto 4-aminothiophenol which combines the advantages of the high conductivity and the stability of immobilized biomolecules. To monitor the extension of the affinity reactions the amperometric transduction at disposable screen-printed carbon electrodes was performed at -200 mV (vs the Ag pseudo-reference electrode) upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. After optimizing all the experimental variables affecting the operation and response of this immunosensing approach its analytical performance was characterized and their practical applicability successfully demonstrated by analysis of real human serum samples. The promising analytical performance exhibited by this new amperometric immunosensor of simple operation, disposable SPCE format and possibility to use pocket-size electrochemical transducers makes it very attractive alternative to commonly used ELISAs for the development of automated POC systems for on-site determination of this powerful biomarker associated with HF., The financial support of projects: Retos Colaboración RTC-2015-4184-1 (cofinanced by the Ministry of Economy and Competitivity and FEDER “una manera de hacer Europa”), CTQ2015-70023-R and CTQ2015-64402-C2-1-R (MINECO Research Projects) and S2013/MT-3029 (NANOAVANSENS Program from the Comunidad de Madrid) are gratefully acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Determination of cadherin-17 in tumor tissues of different metastatic grade using a single incubation-step amperometric immunosensor

  • Valverde, Ángela M.
  • Povedano, Eloy
  • Ruiz-Valdepeñas Montiel, Víctor
  • Yáñez-Sedeño, Paloma
  • Garranzo Asensio, María
  • Rodríguez, Nuria
  • Domínguez, Gemma
  • Barderas, Rodrigo
  • Campuzano, Susana
  • Pingarrón, José Manuel
This paper reports the development of an amperometric immunosensing platform for the determination of cadherin-17 (CDH-17), an atypical adhesion protein involved in the progression, metastatic potential, and survival of high prevalence gastric, hepatocellular, and colorectal tumors. The methodology developed relies on the efficient capture and enzymatic labeling of the target protein on the magnetic microparticles (MBs) surface using commercial antibodies and amperometric transduction at screen-printed carbon electrodes (SCPEs) through the HRP/H2O2/HQ system. The developed immunosensing platform allows the selective determination of the target protein at low ng mL-1 level (LOD of 1.43 ng mL-1) in 45 min and using a single incubation step. The electrochemical immunosensor was successfully used for the accurate determination of the target protein in a small amount (0.5 μg) of raw lysates of colon cancer cells with different metastatic potential as well as in extracts from paraffin embedded cancer colon tissues of different metastatic grade., The financial support of the Spanish Ministerio de Economía y Competitividad, Grants CTQ2015-70023-R and CTQ2015-64402-C2-1-R, and the NANOAVANSENS Program from the Comunidad de Madrid (Grant S2013/MT-3029), and predoctoral contracts from the Spanish Ministerio de Economia y Competitividad (E.P.) and Universidad Complutense de Madrid (V.R.-V.M.) are grate fully acknowledged. R.B. acknowledges the financial support of the PI17CIII/00045 Grant from the AES-ISCIII program. M.G.-A. was supported by a contract of the Programa Operativo de Empleo Juvenil y la Iniciativa de Empleo Juvenil (YEI) with the participation of the Consejería de Educacion, Juventud y Deporte de la Comunidad de Madrid y del Fondo Social Europeo., Peer reviewed