Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Stability and toxicity studies for duloxetine and econazole on Spirodela polyrhiza using chiral capillary electrophoresis

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Valimaña Traverso, Jesús Manuel
  • Amariei, Georgiana|||0000-0002-5412-6325
  • Boltes Espínola, Ana Karina|||0000-0001-9686-7730
  • García González, María Ángeles|||0000-0001-6292-8232
Stability and toxicity studies for duloxetine and econazole were achieved using individual solutions and their mixtures. Stability of drugs racemates and enantiomers was investigated under abiotic and biotic conditions. Toxicity was evaluated for the first time on Spirodela polyrhiza. EC50 values were calculated for each individual drug and for their binary mixture. Real (not nominal) concentrations determined by Capillary Electrophoresis were employed in the calculations of toxicity parameters. The use of a 25 mM phosphate buffer (pH 3.0) with 1.5% S-beta-CD as chiral selector at a temperature of 30 degrees C and a separation voltage of - 20 kV enabled the simultaneous enantiomeric separation of duloxetine and econazole in 7.5 min with enantiomeric resolutions of 7.9 and 6.5, respectively. For individual solutions, decay percentages under abiotic conditions were higher for duloxetine (80%) than for econazole (60%), while in presence of Spirodela polyrhiza they increased for duloxetine but not for econazole. Econazole showed the highest decay percentages under abiotic or biotic conditions (100%) in binary mixtures. EC50 values for duloxetine and econazole enabled to include both drugs within the group of very toxic compounds although econazole showed a higher toxicity than duloxetine and the binary mixture., Ministerio de Industria, Economía y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantioseparation by capillary electrophoresis using ionic liquids as chiral selectors

  • Greño Ocariz, Maider
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
doi: 10.1080/10408347.2018.1439365, Capillary electrophoresis is one of the most widely employed analytical techniques to achieve enantiomeric separations. In spite of the fact that there are many chiral selectors commercially available to perform enantioseparations by CE, one of the most relevant topics in this field is the search for new selectors capable of providing high enantiomeric resolutions. Chiral ionic liquids have interesting characteristics conferring them a high potential in chiral separations although only some of them are commercially available.The aim of this article is to review all the works published on the use of chiral ionic liquids as chiral selectors in the development of enantioselective methodologies by CE, covering the period of time from 2006 (when the first research work on this topic was published) to 2017. The use of chiral ionic liquids as sole chiral selectors, as chiral selectors in dual systems or as chiral ligands will be considered. This review also provides detailed analytical information on the experimental conditions used to carry outenantioseparations in different fields as well as on the separation mechanism involved., Ministerio de Economía y Competitividad, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Effect of the combined use of gamma-cyclodextrin and a chiral ionic liquid on the enantiomeric separation of homocysteine by capillary electrophoresis

  • Greño Ocariz, Maider
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
doi: 10.1016/j.chroma.2018.07.023., The enantioseparation of the non-protein amino acid homocysteine by CE was investigated in this article using seven neutral cyclodextrins and five chiral ionic liquids as chiral selectors. Using a previous derivatization step with FMOC and the subsequent separation under neutral conditions, homocysteine enantiomers were only separated when gamma-CD or (R)-N,N,N-trimethyl-2-aminobutanol-bis(trifluoromethane-sulfon)imidate (EtCholNTf2) were employed as sole chiral selectors in the separation buffer. On the one hand, gamma-CD gave rise to the enantiomeric separation in 10 min with a resolution value of 1.9, whereas EtCholNTf2 let to obtain a resolution value of 1.4 in more than 50 min. Then, the evaluation of the combined use of both selectors was also carried out, resulting in a considerable increase in the Rs. The best enantioseparation for homocysteine was obtained when 10 mM EtCholNTf2 was added to 50 mM phosphate buffer (pH 7.0) containing 2 mM gamma-CD. In an attempt to discriminate specific chiral cation effect from the salt effect, the influence of adding LiNTf2 to the separation medium was also evaluated, resulting in lower resolution values for homocysteine when compared to those achieved with the addition of EtCholNTf2, indicating a synergistic effect between EtCholNTf2 and gamma-CD. Interestingly, the enantiomer migration order changed depending on the chiral selector used. When EtCholNTf2 or gamma-CD were used as sole chiral selectors, D-enantiomer was the first-migrating enantiomer. However, an inversion in the migration order was observed when both selectors were employed in a dual system being the L- enantiomer the first-migrating one., Ministerio de Economía y Competitividad, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

An untargeted metabolomic strategy based on liquid chromatography-mass spectrometry to study high glucose-induced changes in HK-2 cells

  • Bernardo Bermejo, Samuel|||0000-0001-9126-7453
  • Sánchez López, Elena
  • Castro Puyana, María|||0000-0003-1412-4103
  • Benito Martínez, Selma|||0000-0002-3118-0564
  • Lucio Cazaña, Francisco Javier de|||0000-0001-9249-8501
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
https://www.sciencedirect.com/science/article/pii/S002196731930247X?via%3Dihub, Diabetes mellitus is a major health concern nowadays. It is estimated that 40 % of diabetics are affected by diabetic nephropathy, one of the complications derived from high glucose blood levels which can lead to chronic loss of kidney function. It is now clear that the renal proximal tubule plays a critical role in the progression of diabetic nephropathy but research focused on studying the molecular mechanisms involved is still needed. The aim of this work was to develop a liquid chromatography-mass spectrometry platform to carry out, for the first time, the untargeted metabolomic analysis of high glucose-induced changes in cultured human proximal tubular HK-2 cells. In order to find the metabolites which were affected by high glucose and to expand the metabolite coverage, intra- and extracellular fluid from HK-2 cells exposed to high glucose (25 mM), normal glucose (5.5 mM) or osmotic control (5.5 mM glucose + 19.5 mM mannitol) were analyzed by two complementary chromatographic modes: hydrophilic interaction and reversed-phase liquid chromatography. Non-supervised principal components analysis showed a good distribution among the three groups of samples. Statistically significant variables were chosen for further metabolite identification. Different metabolic pathways were affected mainly those derived from amino acidic, polyol, and nitrogenous bases metabolism., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Nuclear magnetic resonance to study the interacions acting in the enantiomeric separation of homocysteine by capillary electrophoresis with a dual system of γ-cyclodextrin and (R)-N,N,N-trimethyl-2-aminobutanol-bis(trifluoromethanesulfon)imidate

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
  • Greño Ocariz, Maider
  • Salgado Serrano, Antonio
doi: 10.1002/elps.201800483., The enantiomeric separation of FMOC-homocysteine by CE was investigated using γ-CD and the chiral ionic liquid (R)-N,N,N-trimethyl-2-aminobutanol- bis(trifluoromethane-sulfon)imidate (EtCholNTf2) as chiral selectors in a 50 mM borate buffer at pH 9.0. The separation of the enantiomers was achieved in 5 min with a resolution value of 0.9 when using 10 mM γ-CD. However, the enantiomeric separation did not take place when the ionic liquid was employed as sole the chiral selector. Thus, the combination of both selectors was studied, obtaining higher Rs values for FMOC-homocysteine and a reversal in the enantiomer migration order in comparison with the use of γ-CD alone in the separation buffer. Then, NMR experiments were carried out in order to explain the experimental results obtained. The NMR analyses showed the formation of an inclusion complex, being the hydrophobic group of FMOC-homocysteine inserted into the γ-CD cavity. Interactions between EtCholNTf2 and γ-CD were also observed, suggesting that the ionic liquid would also enter the cavity of the γ-CD., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Amino acid chiral ionic liquids combined with hydroxypropyl-beta-cyclodextrin for drug enantioseparation by capillary electrophoresis

  • Salido Fortuna, Sandra|||0000-0002-0792-3559
  • Greño Ocariz, Maider
  • Castro Puyana, María|||0000-0003-1412-4103
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
Four amino acid chiral ionic liquids were evaluated in dual systems with hydroxypropyl-beta-cyclodextrin to investigate the enantioseparation by CE of a group of seven drugs as model compounds (duloxetine, verapamil, terbutaline, econazole, sulconazole, metoprolol, and nadolol). The use of two of these chiral ionic liquids (tetramethylammonium L-Lysine ([TMA][L-Lys]) and tetramethylammonium L-glutamic acid ([TMA][L-Glu]) as modifiers in CE is reported for the first time in this work whereas tetrabutylammonium L-lysine [TBA][L-Lys]) and tetrabutylammonium L-glutamic acid ([TBA][L-Glu]) were employed previously in CE although very scarcely. The effect of the nature and the concentration of each ionic liquid added to the separation buffer containing the neutral cyclodextrin on the enantiomeric resolution and the migration time obtained for each drug, was investigated. A synergistic effect was observed when combining each chiral ionic liquid with hydroxypropyl-beta-cyclodextrin in the case of the five compounds for which the cyclodextrin showed enantiomeric discrimination power when used as sole chiral selector (duloxetine, verapamil, terbutaline, econazole, sulconazole). Buffer concentration and pH, temperature and separation voltage were varied in order to optimize the enantiomeric separation of these five compounds using dual systems giving rise to resolutions ranging from 1.1 to 6.6. (C) 2019 Elsevier B.V. All rights reserved., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Advances in the determination of non-protein amino acids in foods and biological samples by capillary electrophoresis

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
  • Pérez Miguez, Raquel
  • Salido Fortuna, Sandra|||0000-0002-0792-3559
There are hundreds of non-protein amino acids whose importance in food and biological matrices is still unknown. Many of these compounds mainly exist in food as products formed during food processing, as metabolic intermediates or as additives to increase nutritional and functional properties of food. Moreover, they have also demonstrated to play an important role in the pharmaceutical and clinical fields since they may be used therapeutically in the treatment of some pathologies and their levels may be related with some diseases. For this reason, the analysis of non-protein amino acids may provide relevant information in the food and biological fields. This article reviews the most recent advances in the development of analytical methodologies employing capillary electrophoresis for the achiral and chiral analysis of non-protein amino acids in food and biological samples. With this aim, the most relevant information concerning the separation and detection of these compounds by capillary electrophoresis is discussed and detailed experimental conditions under which their determination was achieved in food and biological samples are given covering the period of time from 2015 to 2018., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Time-series proteomic study of the response of HK-2 cells to hyperglycemic, hypoxic diabetic-like milieu

  • Valdés Tabernero, Alberto|||0000-0002-7901-5816
  • García Pastor, Coral|||0000-0002-7954-9172
  • Castro Puyana, María|||0000-0003-1412-4103
  • Lucio Cazaña, Francisco Javier de|||0000-0001-9249-8501
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
During diabetes, renal proximal tubular cells (PTC) are exposed to a combination of high glucose and hypoxic conditions, which plays a relevant role in the development of diabetic kidney disease (DKD). In this work, a time-series proteomic study was performed to analyse the effect of a diabetic-like microenvironment induced changes on HK-2 cells, a human cell line derived from normal proximal tubular epithelial cells. Cells simultaneously exposed to high glucose (25 mM) and hypoxia (1% O-2) were compared to cells in control conditions for up to 48 h. Diabetic conditions increased the percentage of death cells after 24 and 48 h, but no differences in the protein/cell ratio were found. The relative protein quantification using dimethyl-labeling and UHPLC-MS/MS analysis allowed the identification of 317, 296 and 259 proteins at 5, 24 and 48 h, respectively. The combination of statistical and time expression profile analyses indicated an increased expression of proteins involved in glycolysis, and a decrease of cytoskeletal-related proteins. The exposure of HK-2 cells to high glucose and hypoxia reproduces some of the effects of diabetes on PTC and, with the limitations inherent toin vitrostudies, propose new mechanisms and targets to be considered in the management of DKD., Ministerio de Economía y Competitividad, Comunidad de Madrid, Fundación Jiménez Díaz
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric separation of ivabradine by cyclodextrin-electrokinetic chromatography. Effect of amino acid chiral ionic liquids

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric analysis of pyrethroids and organophosphorus insecticides

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Casado Navas, Natalia
  • Jiménez Jiménez, Sara|||0000-0002-4096-6235
  • García González, María Ángeles|||0000-0001-6292-8232
The use of pesticides has increased sharply in the last decades, not only in agriculture, but also in industry, public health, and other areas. Pyrethroids and organophosphorus insecticides are among the most employed pesticides. These chemicals usually contain asymmetric chiral atoms; thus, they are characterized by stereoisomerism. Although most of these chiral pesticides are produced, used, and released as racemic mixtures, the different enantiomers of these compounds can present different insecticidal activity, different toxicity against vertebrates and invertebrates, and also different persistence in the environment. In fact, in some cases, only one enantiomer is active, while the other can be less active or even toxic to non-target organisms. Therefore, the development of enantioselective analytical methodologies enabling their determination presents a high interest. Different separation techniques, including high performance liquid chromatography, gas chromatography, supercritical fluid chromatography, and capillary electrophoresis, have been employed to achieve the chiral analysis of pyrethroids and organophosphorus insecticides. This review presents the characteristics of the stereoselective analytical methodologies developed with this aim from 2010 to April 2019 and their applications to the analysis of real samples as well as for toxicity and biodegradation studies., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Modeling-based optimization of the simultaneous enantiomeric separation of multicomponent mixtures of phenoxy acid herbicides using dual cyclodextrin systems by Capillary Electrophoresis

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • García González, María Ángeles|||0000-0001-6292-8232
  • Saz Díaz, José María|||0000-0002-6989-8272
  • Casado Navas, Natalia
In this work, the Dubsky's model proposed for Capillary Electrophoresis (CE) enantioseparation systems with a mixture of chiral selectors was applied to the rapid optimization of the simultaneous enantiomeric separation of a multicomponent mixture of six phenoxy acid herbicides using a dual system of two cyclodextrins (CDs), (2-hydroxypropyl)-beta-CD (HP-beta-CD) and heptakis(2,3,6-tri-O-methyl)-beta-CD (TM-beta-CD). Simply by carrying out a small number of individual experiments separately with each CD, the Dubsky's model enabled to foresee the results that could be obtained for any possible combination of concentrations and relative proportion of both CDs in the mixture. Results obtained in this work demonstrated that the model was successful by improving the previous results experimentally obtained by the trial and error method for the simultaneous enantiomeric separation of the six phenoxy acid herbicides studied in this work. In fact, the separation was improved in terms of enantiomeric resolutions obtained (from 1.2 to 4.2 for concentrations of CDs of 4 mM HP-beta-CD and 16 mM TM-beta-CD) and by considerably reducing the time to optimize the separation conditions enabling to find, in a faster and efficient way, the most adequate proportion of both CDs and the concentration of each CD in the mixture to obtain baseline separation of the twelve enantiomers. Additionally, the apparent complexation constants between enantiomers and each CD were calculated. This is the first time that the above-mentioned model was applied to a multicomponent mixture of chiral compounds. (C) 2019 Elsevier B.V. All rights reserved., Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric determination of econazole and sulconazole by electrokinetic chromatography using hydroxypropyl-b-cyclodextrin combined with ionic liquids based on L-lysine and Ly-glutamic acid

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
  • Salido Fortuna, Sandra|||0000-0002-0792-3559
Two analytical methodologies based on the combined use of hydroxypropyl-beta-cyclodextrin and two different amino acid-based chiral ionic liquids (tetrabutylammonium-L-lysine or tetrabutylammonium-L-glutamic acid) in electrokinetic chromatography were developed in this work to perform the enantios-elective determination of econazole and sulconazole in pharmaceutical formulations. The influence of different experimental variables such as buffer concentration, applied voltage, nature and concentration of the ionic liquid, temperature and injection time, on the enantiomeric separation was investigated. The combination of hydroxypropyl-beta-cyclodextrin and tetrabutylammonium-L-lysine under the optimized conditions enabled to achieve the enantiomeric determination of both drugs with high enantiomeric resolution (3.5 for econazole and 2.4 for sulconazole). The analytical characteristics of the developed methodologies were evaluated in terms of linearity, precision, LOD, LOQ and recovery showing good performance for the determination of both drugs which were successfully quantitated in pharmaceutical formulations. This work reports the first analytical methodology enabling the enantiomeric determination of sulconazole in pharmaceutical formulations., Ministerio de Economía y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric separation of colchicine and lacosamide by nano-LC. Quantitative analysis in pharmaceutical formulations

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • García González, María Ángeles|||0000-0001-6292-8232
  • Casado Navas, Natalia
  • Jiang, Z.
A chiral analytical methodology was developed by nano-liquid chromatography (nano-LC) enabling the enantiomeric separation of two chiral drugs, lacosamide (novel antiepileptic drug) and colchicine (antiuremic drug), commercialized as pure enantiomers. A capillary column lab-packed with an amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phase was used in a lab-assembled nano-LC system. Lacosamide and colchicine enantiomers were separated in less than 8.0 and 9.0 min, respectively, with resolution values of 1.6 and 2.3, using 20 nL of sample and 1.8 mu L of mobile phase per analysis. The analytical characteristics of the proposed methodology were evaluated according to the International Council for Harmonisation (ICH) guidelines, showing good analytical performance with good recoveries (97-98% and 100-103%) and precision values (relative standard deviation (RSD) <10.5 and <3.0%) for lacosamide and colchicine enantiomers, respectively. LODs were 1.7 and 2.0 mu g/mL for (S)- and (R)-lacosamide, respectively, and 1.0 mu g/mL for both colchicine enantiomers. Additionally, the developed methodology enabled to detect a 0.1% of the enantiomeric impurities, fulfilling the ICH regulation requirements. The method was applied to the determination of lacosamide and colchicine enantiomers in different pharmaceutical formulations to ensure their quality control. The content of the enantiomeric impurities was below a 0.1% and the amount of (R)-lacosamide and (S)-colchicine agreed with their labeled contents., Universidad de Alcalá, Ministerio de Economía, Industria y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Chiral Capillary Electrophoresis

  • Bernardo Bermejo, Samuel|||0000-0001-9126-7453
  • Sánchez López, Elena
  • Castro Puyana, María|||0000-0003-1412-4103
  • Marina Alegre, María Luisa|||0000-0002-5583-1624
The implications of chirality in different environments are already well known and reported extensively in the literature. Capillary Electrophoresis, a separation technique that only requires few nanoliters of sample, has demonstrated its potential for chiral analysis in the past years. The aim of this article is to provide an overview on the fundamentals and characteristics of Chiral Capillary Electrophoresis as well as the main advances and trends in this topic. Special attention is paid to the most recent technological and methodological developments achieved mainly in the most employed separation mode (Electroki-netic Chromatography). The most noteworthy and recent applications reported on the enantiomeric separation and determination of compounds in pharmaceutical, food, biomedical, environmental or forensic samples will also be critically overviewed. The characteristics of the developed methodologies will be detailed in Tables and future trends will also be discussed. (C) 2020 Elsevier B.V. All rights reserved., Comunidad de Madrid, Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric separation of homocysteine and cysteine by electrokinetic chromatography using mixtures of gamma-cyclodextrin and carnitine-based ionic liquids

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Castro Puyana, María|||0000-0003-1412-4103
  • Greño Ocariz, Maider
Two new chiral ionic liquids based on the ester of the non-protein amino acid carnitine as cationic counterpart were synthesized, characterized and evaluated as chiral selectors for the enantiomeric separation of homocysteine and cysteine derivatized with 9-fluorenylmethoxycarbonyl chloride by electrokinetic chromatography. The use of both ionic liquids, L-carnitine methyl ester bis(trifluoromethane)sulfonimide and L-carnitine methyl ester L-(+)-lactate, as sole chiral selectors in the separation buffer, did not allow the enantiomeric separation of the studied amino acids. However, the combined use of L-carnitine methyl ester bis(trifluoromethane)sulfonimide ionic liquid with gamma-CD forming a dual system led to the enantiomeric separation of both analytes and showed the existence of a strong synergistic effect. On the contrary, the dual system gamma-CD plus L-carnitine methyl ester L-(+)-lactate did not improve the enantiomeric separations with respect to those obtained using the CD alone. The influence of different experimental variables such as buffer composition and pH, and ionic liquid concentration was investigated. Also, the nature of the anionic moiety was evaluated by comparing the results obtained with both ionic liquids when combined with gamma-CD. The use of 2 mM gamma-CD combined with 5 mM L-carnitine methyl ester bis(trifluoromethane)sulfonimide in a 50 mM phosphate buffer at pH 7.0 enabled to achieve the simultaneous enantiomeric separation of homocysteine and cysteine with high resolution values (> 6.0) in analysis times close to 12 min., Comunidad de Madrid, Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Comprehensive metabolomic study of the response of HK-2 cells to hyperglycemic hypoxic diabetic-like milieu

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • Valdés Tabernero, Alberto|||0000-0002-7901-5816
  • Lucio Cazaña, Francisco Javier de|||0000-0001-9249-8501
  • Castro Puyana, María|||0000-0003-1412-4103
  • García Pastor, Coral|||0000-0002-7954-9172
  • Fiehn, Oliver
Diabetic nephropathy (DN) is the leading cause of chronic kidney disease. Although hyperglycaemia has been determined as the most important risk factor, hypoxia also plays a relevant role in the development of this disease. In this work, a comprehensive metabolomic study of the response of HK-2 cells, a human cell line derived from normal proximal tubular epithelial cells, to hyperglycemic, hypoxic diabetic-like milieu has been performed. Cells simultaneously exposed to high glucose (25 mM) and hypoxia (1% O-2) were compared to cells in control conditions (5.5 mM glucose/18.6% O-2) at 48 h. The combination of advanced metabolomic platforms (GC-TOF MS, HILIC- and CSH-QExactive MS/MS), freely available metabolite annotation tools, novel databases and libraries, and stringent cut-off filters allowed the annotation of 733 metabolites intracellularly and 290 compounds in the extracellular medium. Advanced bioinformatics and statistical tools demonstrated that several pathways were significantly altered, including carbohydrate and pentose phosphate pathways, as well as arginine and proline metabolism. Other affected metabolites were found in purine and lipid metabolism, the protection against the osmotic stress and the prevention of the activation of the beta -oxidation pathway. Overall, the effects of the combined exposure of HK-cells to high glucose and hypoxia are reasonably compatible with previous in vivo works., Ministerio de Economía y Competitividad de España
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Enantiomeric determination of drugs in pharmaceutical formulations and biological samples by Electrokinetic Chromatography

  • Marina Alegre, María Luisa|||0000-0002-5583-1624
  • García González, María Ángeles|||0000-0001-6292-8232
  • Casado Navas, Natalia
  • Valimaña Traverso, Jesús Manuel
Chirality is a relevant issue in the pharmaceutical field due to the different biological activity that enantiomers of a chiral drug can show. In fact, the desired biological or pharmaceutical activity might be present in only one of the enantiomers, while the other enantiomer(s) may have different biological activity, be inactive or even toxic. This has motivated in recent years the development of drugs marketed as pure enantiomers to avoid exposing the organism to the action of enantiomers that may not be active or even harmful to health. Thus, it is of high interest to develop enantioselective analytical methodologies to control the presence of enantiomeric impurities and to understand the enantioselective metabolism of chiral drugs. This review gives an overview about the analytical strategies developed by electrokinetic chromatography (EKC) from 2010 to June 2019 for the enantiomeric determination of drugs in both pharmaceutical formulations and biological samples. The types of chiral selectors used, the migration order of enantiomers, their resolution, the detection technique employed and the sensitivity achieved are revised and compared. Also, applications to assess the enantiomeric purity control of pharmaceutical formulations and to determine chiral drugs in biological samples to study their metabolism are included. Advantages and limitations of the chiral methods developed by EKC are also discussed., Ministerio de Economía y Competitividad