Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

BULERIA. Repositorio Institucional de la Universidad de León
Publication Artículo científico (JournalArticle)

Estimating cooling production and monitoring efficiency in chillers using a soft sensor

  • Alonso Castro, Serafín
  • Morán Álvarez, Antonio
  • Pérez López, Daniel
  • Prada Medrano, Miguel Ángel
  • Diaz Blanco, Ignacio
  • Domínguez González, Manuel
[EN] Intensive use of heating, ventilation and air conditioning systems in buildings entails monitoring their efficiency. Moreover, cooling systems are key facilities in large buildings and can account up to 44% of the energy consumption. Therefore, monitoring efficiency in chillers is crucial and, for that reason, a sensor to measure the cooling production is required. However, manufacturers rarely install it in the chiller due to its cost. In this paper, we propose a methodology to build a soft sensor that provides an estimation of cooling production and enables monitoring the chiller efficiency. The proposed soft sensor uses independent variables (internal states of the chiller and electric power) and can take advantage of current or past observations of those independent variables. Six methods (from linear approaches to deep learning ones) are proposed to develop the model for the soft sensor, capturing relevant features on the structure of data (involving time, thermodynamic and electric variables and the number of refrigeration circuits). Our approach has been tested on two different chillers (large water-cooled and smaller air-cooled chillers) installed at the Hospital of León. The methods to implement the soft sensor are assessed according to three metrics (MAE, MAPE and R²). In addition to the comparison of methods, the results also include the estimation of cooling production (and the comparison of the true and estimated values) and monitoring the COP indicator for a period of several days and for both chillers., SI, Ministerio de Ciencia e Innovación, European Regional Development Fund
BULERIA. Repositorio Institucional de la Universidad de León
Publication Artículo científico (JournalArticle)

Virtual sensor for probabilistic estimation of the evaporation in cooling towers

  • Alonso Castro, Serafín
  • Morán Álvarez, Antonio
  • Pérez López, Daniel
  • Prada Medrano, Miguel Ángel
  • Fuertes Martínez, Juan José
  • Domínguez González, Manuel
16th AIAI (Artificial Intelligence Applications and Innovations) Joint International Conference, [EN] Global natural resources are affected by several causes such as climate change effects or unsustainable management strategies. Indeed, the use of water has been intensified in urban buildings because of the proliferation of HVAC (Heating, Ventilating and Air Conditioning) systems, for instance cooling towers, where an abundant amount of water is lost during the evaporation process. The measurement of the evaporation is challenging, so a virtual sensor could be used to tackle it, allowing to monitor and manage the water consumption in different scenarios and helping to plan efficient operation strategies which reduce the use of fresh water. In this paper, a deep generative approach is proposed for developing a virtual sensor for probabilistic estimation of the evaporation in cooling towers, given the surrounding conditions. It is based on a conditioned generative adversarial network (cGAN), whose generator includes a recurrent layer (GRU) that models the temporal information by learning from previous states and a densely connected layer that models the fluctuations of the conditions. The proposed deep generative approach is not only able to yield the estimated evaporation value but it also produces a whole probability distribution, considering any operating scenario, so it is possible to know the confidence interval in which the estimation is likely found. This deep generative approach is assessed and compared with other probabilistic state-of-the-art methods according to several metrics (CRPS, MAPE and RMSE) and using real data from a cooling tower located at a hospital building. The results obtained show that, to the best of our knowledge, our proposal is a noteworthy method to develop a virtual sensor, taking as input the current and last samples, since it provides an accurate estimation of the evaporation with wide enough confidence intervals, contemplating potential fluctuations of the conditions., SI
BULERIA. Repositorio Institucional de la Universidad de León
Publication Artículo científico (JournalArticle)

Interactive visualization for NILM in large buildings using non-negative matrix factorization

  • García Pérez, Diego
  • Díaz Blanco, Ignacio
  • Pérez López, Daniel
  • Cuadrado Vega, Abel Alberto
  • Domínguez González, Manuel
  • Morán Álvarez, Antonio
[EN] Non-intrusive load monitoring (NILM) techniques have recently attracted much interest, since they allow to obtain latent patterns from power demand data in buildings, revealing useful information to the expert user. Unsupervised methods are specially attractive, since they do not require labeled datasets. Particularly, non-negative matrix factorization (NMF) methods decompose a single power demand measurement over a certain time period into a set of components or “parts” that are sparse, non-negative and sum up the original measured quantity. Such components reveal hidden temporal patterns which may be difficult to interpret in complex systems such as large buildings. We suggest to integrate the knowledge of the user into the analysis in order to recognize the real events inside the electric network behind the learnt patterns. In this paper, we integrate the available domain knowledge of the user by means of a visual analytics web application in which an expert user can interact in a fluid way with the NMF outcome through visual approaches such as barcharts, heatmaps or calendars. Our approach is tested with real electric power demand data from a hospital complex, showing how the interpretation of the decomposition is improved by means of interactive data cube visualizations, in which the user can insightfully relate the NMF components to characteristic demand patterns of the hospital such as those derived from human activity, as well as to inefficient behaviors of the largest systems in the hospital., SI, Ministerio de Economía y fondos europeos FEDER