Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

CFD-based comparison study of a new flow diverting stent and commercially-available ones for the treatment of cerebral aneurysms

  • Catalán-Echeverría, B.
  • Kelly, M.E.
  • Peeling, L.
  • Bergstrom, D.
  • Chen, X.
  • Malvè, M.
Flow-diverting stents (FDSs) show considerable promise for the treatment of cerebral aneurysms by diverting blood flow away from the aneurysmal sacs, however, post-treatment complications such as failure of occlusion and subarachnoid haemorrhaging remain and vary with the FDS used. Based on computational fluid dynamics (CFD), this study aimed to investigate the performance of a new biodegradable stent as compared to two metallic commercially available FDSs. CFD models were developed for an idealized cerebral artery with a sidewall aneurysmal sac treated by deploying the aforementioned stents of different porosities (90, 80, and 70%) respectively. By using these models, the simulation and analysis were performed, with a focus on comparing the local hemodynamics or the blood flow in the stented arteries as compared to the one without the stent deployment. For the comparison, we computed and compared the flow velocity, wall shear stress (WSS) and pressure distributions, as well as the WSS related indices, all of which are of important parameters for studying the occlusion and potential rupture of the aneurysm. Our results illustrate that the WSS decreases within the aneurysmal sac on the treated arteries, which is more significant for the stents with lower porosity or finer mesh. Our results also show that the maximum WSS near the aneurysmal neck increases regardless of the stents used. In addition, the WSS related indices including the time-average WSS, oscillatory shear index and relative residence time show different distributions, depending on the FDSs. Together, we found that the finer mesh stents provide more flow reduction and smaller region characterized by high oscillatory shear index, while the new stent has a higher relative residence time.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The Hemodynamics of Aneurysms Treated with Flow-Diverting Stents Considering both Stent and Aneurysm/Artery Geometries

  • Cillo-Velasco, P.R.
  • Luciano, R.D.
  • Kelly, M.E.
  • Peeling, L.
  • Bergstrom, D.J.
  • Chen, X.B.
  • Malve, M.
Flow diverting stents are deployed to reduce the blood flow into the aneurysm, which would thereby induce thrombosis in the aneurysm sac; the stents prevent its rupture. The present study aimed to examine and quantify the impacts of different flow stents on idealized configurations of the cerebral artery. In our study, we considered a spherical sidewall aneurysm located on curved and tortuous idealized artery vessels and three stents with different porosities (70, 80 and 90%) for deployment. Using computational fluid dynamics, the local hemodynamics in the presence and absence of the stents were simulated, respectively, under the assumption that the blood flow was unsteady and non-Newtonian. The hemodynamic parameters, such as the intra-aneurysmal flow, velocity field and wall shear stress and its related indices, were examined and compared among the 12 cases simulated. The results illustrated that with the stent deployment, the intra-aneurysmal flow and the wall shear stress and its related indices were considerably modified depending on both stent and aneurysm/artery geometries, and that the intra-aneurysmal relative residence time increased rapidly with decreasing stent porosity in all the vessel configurations. These results also inform the rationale for selecting stents for treating aneurysms of different configurations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Use of computational fluid dynamics to compare upper airway pressures and airflow resistance in brachycephalic, mesocephalic, and dolichocephalic dogs

  • Fernández-Parra, R.
  • Pey, P.
  • Zilberstein, L.
  • Malvè, M.
Brachycephalic dog breeds are prone to breathing difficulties because of their upper airway anatomy. Several surgical techniques exist to correct anatomical pathologies and common surgical approaches aim to correct functional abnormalities in the nares and/or the soft palate. However, further research is needed to improve clinical outcomes. This study evaluated air pressure and airflow resistance in the upper airways and trachea in nine sedated, sternally recumbent dogs of different skull types (dolichocephalic, n = 3; mesocephalic, n = 3; brachycephalic, n = 3). CT images were acquired from the nostrils to the caudal border of the lungs and geometrical reconstruction of the upper airway and trachea was performed. Analysis of computational fluid dynamics was performed using inspiratory flow adapted to bodyweight for each dog. Flow (L/min) and pressure (cmH2O) were computed for the entire upper airway and trachea. Resistance (cmH2O/L/min) was calculated using pressure differences between the nose, larynx, and trachea. In this pilot study, statistical comparisons were not performed. Pressure maps, airflow, and resistance were similar in dolichocephalic and mesocephalic breeds. Median pressure difference (3.76 cmH2O) and resistance (0.154 cmH2O/L/min) between the nose and larynx were numerically higher in brachycephalic dogs than in other breeds (0.45 cmH2O and 0.016 cmH2O/L/min, respectively). Median pressure difference (0.205 cmH2O) and resistance (0.009 cmH2O/L/min) between the larynx and trachea was numerically similar in all dogs, except for the English bulldog. The methodology used in this preliminary study to quantify airflow characteristics such as pressure and resistance could improve the understanding of brachycephalic obstruction airway syndrome.