Skip to main content

APRENDIZAJE DE AFFORDANCS PARA EL CONTROL DE ROBOTS POR INTENCIONES

DPI2011-25892

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2011
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Detecting intention to walk in stroke patients from pre-movement EEG correlates

  • Sburlea, A.I.
  • Montesano, L.
  • Cano de la Cuerda, R.
  • Alguacil Diego, I.M.
  • Miangolarra-Page, J.
  • Minguez, J.
Background: Most studies in the field of brain-computer interfacing (BCI) for lower limbs rehabilitation are carried out with healthy subjects, even though insights gained from healthy populations may not generalize to patients in need of a BCI. Methods: We investigate the ability of a BCI to detect the intention to walk in stroke patients from pre-movement EEG correlates. Moreover, we also investigated how the motivation of the patients to execute a task related to the rehabilitation therapy affects the BCI accuracy. Nine chronic stroke patients performed a self-initiated walking task during three sessions, with an intersession interval of one week. Results: Using a decoder that combines temporal and spectral sparse classifiers we detected pre-movement state with an accuracy of 64 % in a range between 18 % and 85.2 %, with the chance level at 4 %. Furthermore, we found a significantly strong positive correlation (r = 0.561, p = 0.048) between the motivation of the patients to perform the rehabilitation related task and the accuracy of the BCI detector of their intention to walk. Conclusions: We show that a detector based on temporal and spectral features can be used to classify pre-movement state in stroke patients. Additionally, we found that patients'' motivation to perform the task showed a strong correlation to the attained detection rate of their walking intention.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Exploiting task constraints for self-calibrated brain-machine interface control using error-related potentials

  • Iturrate, I.
  • Grizou, J.
  • Omedes, J.
  • Oudeyer, P.Y
  • Lopes, M.
  • Montesano, L.
This paper presents a new approach for self-calibration BCI for reaching tasks using error- related potentials. The proposed method exploits task constraints to simultaneously cali- brate the decoder and control the device, by using a robust likelihood function and an ad- hoc planner to cope with the large uncertainty resulting from the unknown task and decoder. The method has been evaluated in closed-loop online experiments with 8 users using a pre- viously proposed BCI protocol for reaching tasks over a grid. The results show that it is pos- sible to have a usable BCI control from the beginning of the experiment without any prior calibration. Furthermore, comparisons with simulations and previous results obtained using standard calibration hint that both the quality of recorded signals and the performance of the system were comparable to those obtained with a standard calibration approach
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Revisiting LP-NUCA Energy Consumption: Cache Access Policies and Adaptive Block Dropping

  • Suárez Gracia, Darío
  • Ferrerón, Alexandra
  • Montesano del Campo, Luis
  • Monreal Arnal, Teresa
  • Viñals Yúfera, Víctor
Cache working-set adaptation is key as embedded systems move to multiprocessor and Simultaneous Multithreaded Architectures (SMT) because interthread pollution harms system performance and battery life. Light-Power NUCA (LP-NUCA) is a working-set adaptive cache that depends on temporal-locality to save energy. This work identifies the sources of energy waste in LP-NUCAs: parallel access to the tag and data arrays of the tiles and low locality phases with useless block migration. To counteract both issues, we prove that switching to serial access reduces energy without harming performance and propose a machine learning Adaptive Drop Rate (ADR) controller that minimizes the amount of replacement and migration when locality is low. This work demonstrates that these techniques efficiently adapt the cache drop and access policies to save energy. They reduce LP-NUCA consumption 22.7% for 1SMT. With interthread cache contention in 2SMT, the savings rise to 29%. Versus a conventional organization, energy--delay improves 20.8% and 25% for 1- and 2SMT benchmarks, and, in 65% of the 2SMT mixes, gains are larger than 20%.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On the Usage of Linear Regression Models to Reconstruct Limb Kinematics from Low Frequency EEG Signals

  • Antelis, J.M.
  • Montesano, L.
  • Ramos-Murguialday, A.
  • Birbaumer, N.
  • Minguez, J.
Several works have reported on the reconstruction of 2D/3D limb kinematics from low-frequency EEG signals using linear regression models based on positive correlation values between the recorded and the reconstructed trajectories. This paper describes the mathematical properties of the linear model and the correlation evaluation metric that may lead to a misinterpretation of the results of this type of decoders. Firstly, the use of a linear regression model to adjust the two temporal signals (EEG and velocity profiles) implies that the relevant component of the signal used for decoding (EEG) has to be in the same frequency range as the signal to be decoded (velocity profiles). Secondly, the use of a correlation to evaluate the fitting of two trajectories could lead to overly-optimistic results as this metric is invariant to scale. Also, the correlation has a non-linear nature that leads to higher values for sinus/cosinus-like signals at low frequencies. Analysis of these properties on the reconstruction results was carried out through an experiment performed in line with previous studies, where healthy participants executed predefined reaching movements of the hand in 3D space. While the correlations of limb velocity profiles reconstructed from low-frequency EEG were comparable to studies in this domain, a systematic statistical analysis revealed that these results were not above the chance level. The empirical chance level was estimated using random assignments of recorded velocity profiles and EEG signals, as well as combinations of randomly generated synthetic EEG with recorded velocity profiles and recorded EEG with randomly generated synthetic velocity profiles. The analysis shows that the positive correlation results in this experiment cannot be used as an indicator of successful trajectory reconstruction based on a neural correlate. Several directions are herein discussed to address the misinterpretation of results as well as the implications on previous invasive and non-invasive works.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Continuous decoding of movement intention of upper limb self-initiated analytic movements from pre-movement EEG correlates

  • López-Larraz, E.
  • Montesano, L.
  • Gil-Agudo, Á.
  • Minguez, J.
 Background: Brain-machine interfaces (BMI) have recently been integrated within motor rehabilitation therapies by actively involving the central nervous system (CNS) within the exercises. For instance, the online decoding of intention of motion of a limb from pre-movement EEG correlates is being used to convert passive rehabilitation strategies into active ones mediated by robotics. As early stages of upper limb motor rehabilitation usually focus on analytic single-joint mobilizations, this paper investigates the feasibility of building BMI decoders for these specific types of movements. Methods: Two different experiments were performed within this study. For the first one, six healthy subjects performed seven self-initiated upper-limb analytic movements, involving from proximal to distal articulations. For the second experiment, three spinal cord injury patients performed two of the previously studied movements with their healthy elbow and paralyzed wrist. In both cases EEG neural correlates such as the event-related desynchronization (ERD) and movement related cortical potentials (MRCP) were analyzed, as well as the accuracies of continuous decoders built using the pre-movement features of these correlates (i.e., the intention of motion was decoded before movement onset). Results: The studied movements could be decoded in both healthy subjects and patients. For healthy subjects there were significant differences in the EEG correlates and decoding accuracies, dependent on the moving joint. Percentages of correctly anticipated trials ranged from 75% to 40% (with chance level being around 20%), with better performances for proximal than for distal movements. For the movements studied for the SCI patients the accuracies were similar to the ones of the healthy subjects. Conclusions: This paper shows how it is possible to build continuous decoders to detect movement intention from EEG correlates for seven different upper-limb analytic movements. Furthermore we report differences in accuracies among movements, which might have an impact on the design of the rehabilitation technologies that will integrate this new type of information. The applicability of the decoders was shown in a clinical population, with similar performances between healthy subjects and patients.