ELECTROHISTEROGRAFIA, CONSTRUYENDO PUENTES PARA SU USO CLINICO EN OBSTETRICIA

DPI2015-68397-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode

  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Bueno Barrachina, José Manuel
  • Rodríguez de Sanabria Gil, Rafael
[EN] Concentric ring electrodes (CRE) have been proposed for sensing bioelectrical activity with high spatial resolution. Computational studies have revealed that the CRE dimensions are closely related to the electric dipole depth they can sense, but further experimental confirmation is needed. We aimed to develop and test a wireless multichannel ECG recording system based on a new flexible multi-ring electrode and to check the influence of CRE dimensions on the acquired signals. The system provided high-precision ECG signals by a simple procedure. The bipolar concentric ECG signal amplitude and SNR increase with the CRE¿s outer ring dimension. Differences in the signal morphologies, associated with different sensitivities to the location of the active dipoles, were also obtained in the case of diameters smaller than 34 mm. A system with several wireless sensor nodes developed could be easily used by clinical staff for non-invasive cardiac monitoring and diagnosis with high spatial and temporal resolution., Research supported in part by a grant from the Conselleria d'Educacio, Cultura I Esport, Generalitat Valenciana Conselleria - Spain (GV/2014/029); by a grant from the Universitat Politecnica de Valencia - Spain (SP20120490); and by the Ministry of Economy and Competitiveness - Spain and the European Regional Development Fund (DPI2015-68397-R (MINECO/FEDER)).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of the effects of Atosiban on uterine electromyograms recorded in women with threatened preterm labor

  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales, Alfredo
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
[EN] Although research studies using electrohysterography on women without tocolytic therapy have shown its potential for preterm birth diagnosis, tocolytics are usually administered in emergency rooms at the first sign of threatened preterm labor (TPL). Information on the uterine response during tocolytic treatment could prove useful for the development of tools able to predict true preterm deliveries under normal clinical conditions. The aim of this study was thus to analyze the effects of Atosiban on Electrohysterogram (EHG) parameters and to compare its effects on women who delivered preterm (WDP) and at term (WDT). Electrohysterograms recorded in different Atosiban therapy stages (before, during and after drug administration) on 40 WDT and 27 WDP were analyzed by computing linear, and non-linear EHG parameters. Results reveal that Atosiban does not greatly affect the EHG signal amplitude, but does modify its spectral content and reduces the energy associated with the fast wave high component in both WDP and WDT, with a faster response in the latter. EHG signal complexity remained constant in WDT, while it increased in WDP until it reached similar values to WDT during Atosiban treatment. The spectral and complexity parameters were able to separate (p < 0.05) WDT and WDP prior to and during tocolytic treatment and before and after treatment, respectively. The results pave the way for developing better and more reliable medical decision support systems based on EHG for preterm delivery prediction in TPL women in clinical scenarios., This work received financial support from the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R), VLC/Campus (UPV-FE-2018-B03) and by Conselleria de Educación, Investigación, Cultura y Deporte, Generalitat Valenciana (GV/2018/104).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Prediction of Labor Induction Success from the Uterine Electrohysterogram

  • Benalcazar-Parra, Carlos
  • Monfort-Ortiz, Rogelio
  • Alberola Rubio, José
  • PERALES MARIN, ALFREDO JOSE
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Prats-Boluda, Gema|||0000-0002-9362-5055
[EN] Pharmacological agents are often used to induce labor. Failed inductions are associated with unnecessarily long waits and greater maternal-fetal risks, as well as higher costs. No reliable models are currently able to predict the induction outcome from common obstetric data (area under the ROC curve (AUC) between 0.6 and 0.7). The aim of this study was to design an early success-predictor system by extracting temporal, spectral, and complexity parameters from the uterine electromyogram (electrohysterogram (EHG)). Different types of feature sets were used to design and train artificial neural networks: Set_1: obstetrical features, Set_2: EHG features, and Set_3: EHG+obstetrical features. Predictor systems were built to classify three scenarios: (1) induced women who reached active phase of labor (APL) vs. women who did not achieve APL (non-APL), (2) APL and vaginal delivery vs. APL and cesarean section delivery, and (3) vaginal vs. cesarean delivery. For Scenario 3, we also proposed 2-step predictor systems consisting of the cascading predictor systems from Scenarios 1 and 2. EHG features outperformed traditional obstetrical features in all the scenarios. Little improvement was obtained by combining them (Set_3). The results show that the EHG can potentially be used to predict successful labor induction and outperforms the traditional obstetric features. Clinical use of this prediction system would help to improve maternal-fetal well-being and optimize hospital resources., This work received financial support from the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (DPI2015-68397-R and RTI2018-094449-A-I00), Universitat Politècnica de València VLC/Campus (UPV-FE-2018-B02), Generalitat Valenciana (GV/2018/104), and Bial S.A.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and Assessment of a Robust and Generalizable ANN-Based Classifier for the Prediction of Premature Birth by means of Multichannel Electrohysterographic Records

  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales Marín, Alfredo José
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Preterm labor is one of the major causes of neonatal deaths and also the cause of significant health and development impairments in those who survive. However, there are still no reliable and accurate tools for preterm labor prediction in clinical settings. Electrohysterography (EHG) has been proven to provide relevant information on the labor time horizon. Many studies focused on predicting preterm labor by using temporal, spectral, and nonlinear parameters extracted from single EHG recordings. However, multichannel analysis, which includes information from the whole uterus and about coupling between the recording areas, may provide better results. The cross validation method is often used to design classifiers and evaluate their performance. However, when the validation dataset is used to tune the classifier hyperparameters, the performance metrics of this dataset may not properly assess its generalization capacity. In this work, we developed and compared different classifiers, based on artificial neural networks, for predicting preterm labor using EHG features from single and multichannel recordings. A set of temporal, spectral, nonlinear, and synchronization parameters computed from EHG recordings was used as the input features. All the classifiers were evaluated on independent test datasets, which were never ¿seen¿ by the models, to determine their generalization capacity. Classifiers¿ performance was also evaluated when obstetrical data were included. The experimental results show that the classifier performance metrics were significantly lower in the test dataset (AUC range 76-91%) than in the train and validation sets (AUC range 90-99%). The multichannel classifiers outperformed the single-channel classifiers, especially when information was combined into mean efficiency indexes and included coupling information between channels. Including obstetrical data slightly improved the classifier metrics and reached an AUC of for the test dataset. These results show promise for the transfer of the EHG technique to preterm labor prediction in clinical practice., This work was supported by the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (DPI2015-68397-R, MINECO/FEDER, and RTI2018-094449-A-I00-AR); Generalitat Valenciana (AICO/2019/220); and the VLC/Campus (UPV-FE-2018-B03).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

New electrohysterogram-based estimators of intrauterine pressure signal, tonus and contraction peak for non-invasive labor monitoring

  • Benalcazar-Parra, Carlos
  • Alberola-Rubio, José
  • López-Corral, Angel
  • PERALES MARIN, ALFREDO JOSE
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
[EN] Background: Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activity of uterine cells, surface electrohysterography (EHG) has become a noninvasive monitoring alternative. The Teager energy (TE) operator of the EHG signal has been used for IUP continuous pressure estimation, although its accuracy could be improved. We aimed to develop new optimized IUP estimation models for clinical application. Approach: We first considered enhancing the optimal estimation of IUP clinical features (maximum pressure and tonus) rather than optimizing the signal only (continuous pressure). An adaptive algorithm was also developed to deal with inter-patient variability. For each optimizing signal feature (continuous pressure, maximum pressure and tonus), individual (single patient), global (full database) and adaptive models were built to estimate the recorded IUP signal. The results were evaluated by computing the root mean square errors (RMSe): continuous pressure error (CPe), maximum pressure error (MPe) and tonus error (TOe). Main results: The continuous pressure global model yielded IUP estimates with Cpe = 14.61mm Hg, MPe = 29.17mm Hg and Toe = 7.8mm Hg. The adaptive models significantly reduced errors to CPe = 11.88, MPe = 16.02 and Toe = 5.61mm Hg. The EHG-based IUP estimates outperformed those from traditional tocographic recordings, which had significantly higher errors (CPe = 21.93, MPe = 26.97, and TOe = 13.96). Significance: Our results show that adaptive models yield better IUP estimates than the traditional approaches and provide the best balance of the different errors computed for a better assessment of the labor progress and maternal and fetal wellbeing., This research project was supported by the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (DPI2015-68397-R), and by the projects UPV_ FE-2018-C03 and GV/2018/104.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrohysterographic characterization of the uterine myoelectrical response to labor induction drugs

  • Benalcazar-Parra, Carlos
  • Garcia Casado, Javier
  • Monfort-Orti, Rogelio
  • Alberola Rubio, José
  • Perales Marín, Alfredo Jose
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
[EN] Labor induction is a common practice to promote uterine contractions and labor onset. Uterine electrohysterogram (EHG) has proved its suitability for characterizing the uterus electrophysiological condition in women with spontaneous labor. The aim of this study was to characterize and compare uterine myoelectrical activity during the first 4h in response to labor induction drugs, Misoprostol (G1) and Dinoprostone (G2), by analyzing the differences between women who achieved active phase of labor and those who did not (successful and failed inductions). A set of temporal, spectral and complexity parameters were computed from the EHG-bursts. As for successful inductions, statistical significant and sustained increases with respect to basal period were obtained for EHG amplitude, mean frequency, uterine activity index (UAI) and Teager, after 60¿ for the G1 group; duration, amplitude, number of contractions and UAI for the G2 group, after 120¿. Moreover, Teager showed statistical significant and sustained differences between successful and failed inductions (1.43±1.45 µV2.Hz2.105 vs. 0.40±0.26 µV2.Hz2.105 after 240¿) for the G1 group, but not in the G2 group, probably due to the slower pharmacokinetics of this drug. These results revealed that EHG could be useful for successful induction prediction in the early stages of induction, especially when using Misoprostol., This research project was supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R) and by the company Bial SA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Prediction of labor onset type: Spontaneous vs induced, role of electrohysterography?

  • Alberola Rubio, José
  • Prats-Boluda, Gema
  • Desantes, D.
  • Valero, J.
  • Perales Marin, Alfredo Jose
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] Background and objective: Induction of labor (IOL) is a medical procedure used to initiate uterine contractions in order to achieve delivery. IOL entails medical risks and has a significant impact on both maternal and neonatal well-being. An automatic system capable of distinguishing women who will enter labor spontaneously from those who will require late-term IOL could support clinicians and mothers in making informed decisions about prolonging pregnancy. With this aim, we developed and evaluated predictive models using not only traditional obstetrical data but also electrophysiological parameters derived from the electrohysterogram (EHG). Methods: EHG recordings were obtained from singleton term pregnancies. A set of 10 temporal and spectral parameters was calculated to characterize EHG bursts, and 6 common obstetrical parameters was also considered in the design of the predictive models. Different models were implemented based on single-layer Support Vector Machines (SVM) and on SVM ensembles using majority voting (double layer), to distinguish between two groups: term spontaneous labor (≤ 41 weeks of gestation) and late-term IOL. The areas under the receiver operating characteristic curve (AUC) of the models were compared. Results: Obstetrical and EHG parameters did not differ significantly between the two groups. Among the non-contextualized single-input SVM models, the best-performing obstetrical predictors were the Bishop score (AUC = 0.65) and gestational age at recording time (AUC = 0.68). When the EHG parameter median frequency was contextualized with these two obstetrical parameters, performance improved to an AUC of 0.76. A multiple-input SVM model using all EHG parameters achieved an AUC of 0.70. The best performance was obtained with the majority-voting SVM ensemble using contextualized EHG parameters, which reached an AUC of 0.93. Conclusions: Measuring the electrophysiological uterine condition by means of electrohysterographic recordings yielded a promising clinical decision support system for distinguishing patients that will spontaneously achieve active labor before the end of full term from those who will require late term IOL. The importance of considering these EHG measurements in the patient's individual context was also shown by combining EHG parameters with obstetrical parameters. Clinicians considering elective labor induction would benefit from this technique., General Electric Healthcare
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Uterine contractile efficiency indexes for labor prediction: a bivariate approach from multichannel electrohysterographic records

  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales Marín, Alfredo Jose
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Prats-Boluda, Gema|||0000-0002-9362-5055
[EN] Labor prediction is one of the most challenging goals in obstetrics, mainly due to the poor understanding of the factors responsible for the onset of labor. The electrohysterogram (EHG) is the recording of the myoelectrical activity of myometrial cells and has been shown to provide relevant information on the electrophysiological state of the uterus. This information could be used to obtain more accurate labor predictions than those of the currently used techniques, such as the Bishop score, tocography or biochemical markers. Indeed, a number of efforts have already been made to predict labor by this method, separately characterizing the intensity, the coupling degree of the EHG signals and myometrial cell excitability, these being the cornerstones on which contraction efficiency is built. Although EHG characterization can distinguish between different obstetric situations, the reported results have not been shown to provide a practical tool for the clinical detection of true labor. The aim of this work was thus to define and calculate indexes from multichannel EHG recordings related to all the phenomena involved in the efficiency of uterine myoelectrical activity (intensity, excitability and synchronization) and to combine them to form global efficiency indexes (GEI) able to predict delivery in less than 7/14 days. Four EHG synchronization indexes were assessed: linear correlation, the imaginary part of the coherence, phase synchronization and permutation cross mutual information. The results show that even though the synchronization and excitability efficiency indexes can detect increasing trends as labor approaches, they cannot predict labor in less than 7/14 days. However, intensity seems to be the main factor that contributes to myometrial efficiency and is able to predict labor in less than 7/14 days. All the GEls present increasing monotonic trends as pregnancy advances and are able to identify (p < 0.05) patients who will deliver in less than 7/14 days better than single channel and single phenomenon parameters. The GEI based on the permutation cross mutual information shows especially promising results. A simplified EHG recording protocol is proposed here for clinical practice, capable of predicting deliveries in less than 7/14 days, consisting of 4 electrodes vertically aligned with the median line of the uterus. (C) 2018 Elsevier Ltd. All rights reserved., The authors are grateful to Zhenhu Liang, of the Yanshan University, who provided essential information for computing the PLV and NPCMI synchronization indexes. This work was supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R, MINECO/FEDER).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes

  • Estrada-Petrocelli, Luis
  • Torres, Abel
  • Sarlabous, Leonardo
  • Ràfols-de-Urquía, Magda
  • Jané, Raimon
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
[EN] Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (R-ins/noise), (4) basal sEMG with ECG (R-ins/cardio) and (5) expiratory sEMG without ECG (R-ins/exp). Spectral power, R-ins/noise and R-ins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of R-ins/cardio and significantly higher median frequencies were obtained for CREs. R-ins/noise and R-ins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement., This work was supported in part by the CERCA Program/Generalitat de Catalunya, in part by the Secretaria d'Universitats i Recerca de la Generalitat de Catalunya under Grant GRC 2017 SGR 01770, in part by the Spanish Grants RTI2018-098472-B-I00, RTI2018-094449-A-I00-AR (MCIU/AEI/FEDER, UE) and DPI2015-68397-R (MINECO/FEDER), and in part by the Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN, Instituto de Salud Carlos III/FEDER). The first author was supported by the IFARHU-SENACYT Scholarship Program from the Panama Government under Grant 270-2012-273.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrohysterography in the diagnosis of preterm birth: a review

  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Mas-Cabo, Javier
  • Alberola Rubio, José
  • Perales Marin, Alfredo Jose
[EN] Preterm birth (PTB) is one of the most common and serious complications in pregnancy. About 15 million preterm neonates are born every year, with ratios of 10-15% of total births. In industrialized countries, preterm delivery is responsible for 70% of mortality and 75% of morbidity in the neonatal period. Diagnostic means for its timely risk assessment are lacking and the underlying physiological mechanisms are unclear. Surface recording of the uterine myoelectrical activity (electrohysterogram, EHG) has emerged as a better uterine dynamics monitoring technique than traditional surface pressure recordings and provides information on the condition of uterine muscle in different obstetrical scenarios with emphasis on predicting preterm deliveries. Objective: A comprehensive review of the literature was performed on studies related to the use of the electrohysterogram in the PTB context. Approach: This review presents and discusses the results according to the different types of parameter (temporal and spectral, non-linear and bivariate) used for EHG characterization. Main results: Electrohysterogram analysis reveals that the uterine electrophysiological changes that precede spontaneous preterm labor are associated with contractions of more intensity, higher frequency content, faster and more organized propagated activity and stronger coupling of different uterine areas. Temporal, spectral, non-linear and bivariate EHG analyses therefore provide useful and complementary information. Classificatory techniques of different types and varying complexity have been developed to diagnose PTB. The information derived from these different types of EHG parameters, either individually or in combination, is able to provide more accurate predictions of PTB than current clinical methods. However, in order to extend EHG to clinical applications, the recording set-up should be simplified, be less intrusive and more robust-and signal analysis should be automated without requiring much supervision and yield physiologically interpretable results. Significance: This review provides a general background to PTB and describes how EHG can be used to better understand its underlying physiological mechanisms and improve its prediction. The findings will help future research workers to decide the most appropriate EHG features to be used in their analyses and facilitate future clinical EHG applications in order to improve PTB prediction., This work was supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund under grant DPI2015-68397-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Uterine electromyography for discrimination of labor imminence in women with threatened preterm labor under tocolytic treatment

  • Mas-Cabo, Javier
  • Perales Marín, Alfredo Jose
  • Alberola Rubio, José
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
[EN] As one of the main aims of obstetrics is to be able to detect imminent delivery in patients with threatened preterm labor, the techniques currently used in clinical practice have serious limitations in this respect. The electrohysterogram (EHG) has now emerged as an alternative technique, providing relevant information about labor onset when recorded in controlled checkups without administration of tocolytic drugs. The studies published to date mainly focus on EHG-burst analysis and, to a lesser extent, on whole EHG window analysis. The study described here assessed the ability of EHG signals to discriminate imminent labor (<7days) in women with threatened preterm labor undergoing tocolytic therapy, using both EHG-burst and whole EHG window analyses, by calculating temporal, spectral, and non-linear parameters. Only two non-linear EHG-burst parameters and four whole EHG window analysis parameters were able to distinguish the women who delivered <7days from the others, showing that EHG can provide relevant information on the approach of labor, even in women with threatened preterm labor under the effects of tocolytic therapy. The whole EHG window outperformed the EHG-burst analysis and is seen as a step forward in the development of real-time EHG systems able to predict imminent labor in clinical praxis>The ability of EHG recordings to predict imminent labor (<7days) was analyzed in preterm threatened patients undergoing tocolytic therapies by means of EHG-burst and whole EHG window analysis. The non-linear features were found to have better performance than the temporal and spectral parameters in separating women who delivered in less than 7days from those who did not.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Flexible Multiring Concentric Electrode for Non-Invasive Identification of Intestinal Slow Waves

  • Zena-Giménez, Victor Fabián
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
  • Prats-Boluda, Gema|||0000-0002-9362-5055
[EN] Developing new types of optimized electrodes for specific biomedical applications can substantially improve the quality of the sensed signals. Concentric ring electrodes have been shown to provide enhanced spatial resolution to that of conventional disc electrodes. A sensor with different electrode sizes and configurations (monopolar, bipolar, etc.) that provides simultaneous records would be very helpful for studying the best signal-sensing arrangement. A 5-pole electrode with an inner disc and four concentric rings of different sizes was developed and tested on surface intestinal myoelectrical recordings from healthy humans. For good adaptation to a curved body surface, the electrode was screen-printed onto a flexible polyester substrate. To facilitate clinical use, it is self-adhesive, incorporates a single connector and can perform dry or wet (with gel) recordings. The results show it to be a versatile electrode that can evaluate the optimal configuration for the identification of the intestinal slow wave and reject undesired interference. A bipolar concentric record with an outer ring diameter of 30 mm, a foam-free adhesive material, and electrolytic gel gave the best results., Grant from the Ministerio de Economia y Competitividad y del Fondo Europeo de Desarrollo Regional. DPI2015-68397-R (MINECO/FEDER).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparison of labour induction with misoprostol and dinoprostone and characterization of uterine response based on electrohysterogram

  • Benalcazar-Parra, Carlos
  • Monfort-Orti, Rogelio
  • Alberola Rubio, José
  • Perales Marín, Alfredo Jose
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Garcia-Casado, Javier|||0000-0003-1410-2721
[EN] Objective: The objective of this study is to compare the uterine activity response between women administered dinoprostone (prostaglandin E2) and misoprostol (prostaglandin E1) for induction of labour (IOL) by analysing not only the traditional obstetric data but also the parameters extracted from uterine electrohysterogram (EHG). Methods: Two cohorts were defined: misoprostol (25-mg vaginal tablets; 251 women) and dinoprostone cohort (10 mg vaginal inserts; 249 women). All the mothers were induced by a medical indication of a Bishop Score < ¿ 6. Results: The misoprostol cohort was associated with a shorter time to achieve active labour (p ¿ .017) and vaginal delivery (p ¿ .009) and with a higher percentage of vaginal delivery in less than 24 h in mothers with a very unfavourable cervix score (risk ratio (RR): 1.41, IC95% 1.17¿1.69, p ¿ .002). Successful inductions with misoprostol showed EHG parameter values significantly higher than basal state for amplitude and pseudo Montevideo units (PMU) 60¿ after drug administration, while spectral parameters significantly increased after 150¿. This response was not observed in failed inductions. In the successful dinoprostone group, the duration and number of contractions increased significantly after 120¿, PMU did so after 180¿, and no significant differences were found for spectral parameters, possibly due to the slower pharmacokinetics of this drug. Conclusion: Successful inductions of labour by misoprostol are associated with earlier effective contractions than in labours induced by dinoprostone., This work was partially supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund under grant [DPI2015-68397-R] and by the company Bial SA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Textile Concentric Ring Electrodes: Influence of Position and Electrode Size on Cardiac Activity Monitoring

  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
  • Pradas-Novella, Francisco
  • Garcia-Casado, Javier
[EN] Continuous ECG monitoring can play an important role in the rapid detection of pathological signatures and arrhythmias. Current systems use electrodes with limitations in wearable long-term applications and spatial selectivity. In this work, two sizes of textile concentric ring electrodes (TCRE42 and TCRE50) were developed and tested for monitoring cardiac activity. The low-cost devices were found to be easy to implement and to potentially have the advantages of textile electrodes for being lightweight, stretchable, adjustable, washable, and long-lasting. Both TCREs yielded similar signal detectability of different ECG waves. The optimal P wave recording area (OPA) for detecting signals was on the upper right chest. Although the absolute signal amplitude of TCRE records was smaller than that of lead II, normalized amplitude in the OPA is similar for T wave and higher for P wave. The TCREs also allowed better analysis of P wave morphology and were able to detect more right and left atrial depolarization waves. TCRE48 showed slightly better detectability, normalized amplitude, and spatial selectivity than TCRE50 within the OPA. The authors consider the TCRE suitable for use in ubiquitous mobile health care systems, especially for atrial activity monitoring and diagnosis, This work was supported by grants from the Ministerio de Economia y Competitividad and the European Regional Development Fund (DPI2015-68397-R) (MINECO/FEDER). This work was also supported by the Spanish Government/FEDERfunds (MAT2015-64139-C4-3-R) (MINECO/FEDER).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology

  • Lidon-Roger, Jose V.|||0000-0003-3839-7878
  • Prats-Boluda, Gema|||0000-0002-9362-5055
  • Ye Lin, Yiyao|||0000-0003-2929-181X
  • Garcia-Casado, Javier|||0000-0003-1410-2721
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
[EN] Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT: PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT: PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT: PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT: PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment., Grant from the Ministerio de Economia y Competitividad y del Fondo Europeo de Desarrollo Regional. DPI2015-68397-R (MINECO/FEDER). This work was also supported by the Spanish Government/FEDER funds (grant number MAT2015-64139-C4-3-R (MINECO/FEDER)).