LENTES INTRAOCULARES AVANZADAS: DISEÑO, CALIDAD OPTICA Y REPERCUSION CLINICA

DPI2016-76019-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design

  • Vega, F.
  • Millan, M.S.
  • Garzon, N.
  • Altemir, I.
  • Poyales, F.
  • Larrosa, J.M.
The optical quality of a set of IOLs (modeling set: one monofocal and two bifocals) was assessed through focus by the area under the modulation transfer function (MTFa) metric and related to the visual acuity (VA) defocus curves of pseudophakic patients implanted with said IOLs. A non-linear relationship between the MTFa and clinical VA was obtained with an asymptotic limit found to be the best VA achievable by the patients. Two mathematical fitting functions between clinical VA and MTFa were derived with high correlation coefficients (R-2 >= 0.85). They were applied to the MTFa obtained from a different set of IOLs with advanced designs (trial set: one extended range of vision -ERV-, one trifocal ERV and one trifocal apodized) to predict VA versus defocus of patients implanted with these IOLs. Differences between the calculated VA and the clinical VA for both fitting models were within the standard deviation of the clinical measurements in the range of -3.00 D to 0.00 D defocus. thus proving the suitability of the MTFa metric to predict clinical VA performance of new IOL designs. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses

  • Altemir-Gomez, I.
  • Millan, M.S.
  • Vega, F.
  • Bartol-Puyal, F.
  • Gimenez-Calvo, G.
  • Larrosa, J.M.
  • Polo, V.
  • Pablo, L.E.
  • Garcia-Martin, E.
Objective: To compare visual quality in patients implanted with Tecnis ® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their optical quality measured in vitro with an eye model. Methods: In total, 122 patients participated in this study: 44 implanted with monofocal and 78 with multifocal intraocular lenses. Measurements of visual acuity and contrast sensitivity were performed. The optical quality of the intraocular lenses was evaluated in three image planes (distance, intermediate and near) using an eye model on a test bench. The metric considered was the area under the curve of the modulation transfer function. Results: Optical quality at the far focus of the monofocal intraocular lens (area under the curve of the modulation transfer function = 66.97) was considerably better than that with the multifocal lens (area under the curve of the modulation transfer function = 32.54). However, no significant differences were observed between groups at the distance-corrected visual acuity. Distance-corrected near vision was better in the multifocal (0.15 ± 0.20 logMAR) than that in the monofocal group (0.43 ± 0.21 logMAR, p < 0.001), which correlated with the better optical quality at near reached by the multifocal intraocular lens (area under the curve of the modulation transfer function = 29.11) in comparison with the monofocal intraocular lens (area under the curve of the modulation transfer function = 5.0). In intermediate vision, visual acuity was 0.28 ± 0.16 logMAR (multifocal) and 0.36 ± 0.14 logMAR (monofocal) with p = 0.014, also in good agreement with the values measured in the optical quality (area under the curve of the modulation transfer function = 10.69 (multifocal) and 8.86 (monofocal)). The contrast sensitivity was similar in almost all frequencies. Pelli–Robson was slightly better in the monofocal (1.73) than in the multifocal group (1.64; p = 0.023). Conclusion: Patients implanted with multifocal ZMB00 achieved a distance visual acuity similar to those implanted with monofocal ZCB00, but showed significantly better intermediate and near visual acuity. A correlation was found between intraocular lenses’ optical quality and patients’ visual acuity. Contrast sensitivity was very similar between the multifocal and monofocal groups.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients

  • Armengol, J.
  • Garzón, N.
  • Vega, F.
  • Altemir, I.
  • Millán, M.S.
This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients

  • Armengol Cebrian, Jesús
  • Garzon, Nuria
  • Vega Lerín, Fidel
  • Altemir Gómez, I.
  • Millán Garcia-Varela, M. Sagrario
This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability., Ministerio de Economía y Competitividad y fondos Feder (DPI2016-76019-R)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Through-focus energy efficiency and longitudinal chromatic aberration of three presbyopia-correcting intraocular lenses

  • Millán Garcia-Varela, M. Sagrario
  • Vega Lerín, Fidel
Purpose: To compare the chromatic performance of the Bausch & Lomb Versario 3F trifocal intraocular lens (IOL) with the PhysIOL FineVision MicroF trifocal IOL and the Johnson & Johnson Vision TECNIS Symfony ZXR00 extended range of vision (ERV) IOL. Methods: The through-focus energy efficiency (TF-EE) was measured in vitro with red (R), green (G), and blue (B) wavelengths and was used to obtain the focus powers and longitudinal chromatic aberrations (LCAs) for each IOL. Other metrics, derived from the RGB TF-EE curves, were assessed for a more complete description of the chromatic performance of the IOLs. Results: Both of the trifocal IOLs, although not specifically designed to tackle chromatic aberrations, showed acceptable LCA (=0.50 D) in all foci with more balanced R and B efficiencies of their foci. Despite having the lowest TF-EE value at all foci, the Versario 3F demonstrated the most balanced chromatic performance with the smoothest energy transition among all foci and the smallest chromatic span. The Symfony lens effectively reduced LCA at distance and intermediate foci (=0.36 D), despite the unbalanced and asymmetric R and B efficiencies at its foci. Conclusions: To fully describe the chromatic performance of an IOL it is necessary to take into account not only the LCA but also the RGB TF-EE and chromatic span. This comprehensive analysis suggests that, in comparison with the other IOLs under study, the Versario 3F lens might contribute to further mitigating the impact of chromatic aberration. Translational Relevance: The in vitro bench testing of the optical properties of modern presbyopia-correcting intraocular lenses (more specifically in this work, the polychromatic through-focus energy efficiency and longitudinal chromatic aberration) provides objective and complementary information that helps to interpret the visual quality outcomes of pseudophakic patients obtained in clinics., None of the authors has a financial or proprietary interest in any of the products or materials used in the study. Sources of financial support: public, the Spnaish Ministerio de Economía y Competitividad, and European-Union ERDF funds, under project Ref. No. DPI2016-76019-R and private, Bausch and Lomb Incorporated., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Connectivity-based segmentation of retinal vessels in eye fundus images, Segmentación basada en la conectividad de la red vascular de la retina en imágenes de fondo de ojo

  • Rallo Capdevila, Miguel
  • Millán Garcia-Varela, M. Sagrario
© Sociedad Española de Óptica. A new unsupervised method for segmentation of objects of diverse nature with the common feature of connectivity (e.g. branching trees or net-shaped objects) is proposed. A preferred application to the vasculature segmentation of retinal images has been illustrated using images from DRIVE database. In the pre-processing stage, the method overcomes the common problem of non-uniform illumination of eye fundus images. The method follows with an iterative algorithm that starts with a seed and adds, at each step, a new vessel segment connected to the previously segmented part. The result preserves the connectivity as a distinct feature of the retinal vessel tree. The segmentation performance is evaluated through common signal detection metrics: sensitivity, specificity and accuracy., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Optical performance of a monofocal intraocular lens designed to extend depth of focus

  • Vega Lerín, Fidel
  • Millán Garcia-Varela, M. Sagrario
  • Gil Arnal, Julian Miguel Ángel
  • Garzón Jimenez, Nuria
Purpose: To test the performance of a new monofocal intraocular lens, intended to extend depth of focus (Tecnis Eyhance, ICB00; Johnson & Johnson Vision, Inc) (ICB-IOL), in comparison to a standard monofocal IOL (Tecnis 1-piece, ZCB00; Johnson & Johnson Vision, Inc) (ZCB-IOL) of the same platform and material. Methods: Assessment of the optical performance of the two IOLs was made in vitro using an optical test bench with a model eye. The spherical aberration, modulation transfer function (MTF), and area under the MTF (MTFa) were obtained for pupil sizes ranging from 2 to 5 mm. Through-focus MTFa curves between -3.00 and +1.00 diopters (D) were obtained with three pupil sizes (2, 3, and 4.5 mm). Halo formation was also assessed for both lenses. Results: The ICB-IOL had slightly worse optical quality at its best focus (ie, lower MTF scores at distance vision) and more negative spherical aberration than the ZCB-IOL for pupils ranging from 2 to 3 mm. The maximum of the through-focus MTFa curve of the ICB-IOL with a 2-mm pupil shifted to a myopic defocus of -0.50 D. For larger pupils (= 3.5 mm), there were no differences in spherical aberration, MTF scores, and halo energy between the two lenses. Conclusions: The new ICB-IOL is a modified monofocal lens with 0.50 D of additional power in its central 2-mm zone and more negative spherical aberration values, which induce a myopic shift of the maximum of optical quality and could improve intermediate vision. For pupils larger than 3.5 mm, there were no differences between IOLs. The new ICB-IOL design would produce photic phenomena comparable to a standard IOL., Supported by project DPI2016-76019-R from the Spanish Ministerio de Economía y Competitividad y Fondos FEDER., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Low f-number multiorder diffractive lenses

Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Nonlinear joint transform correlator architectures for images encryption, decryption and authentication systems

Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Visual acuity assessment in phakic and pseudophakic eyes under red, green, and blue illumination, Valoración de la agudeza visual con iluminación roja, verde y azul en ojos fáquicos y pseudofáquicos

  • Clavé Cerezo, Laura
  • Torrents Gómez, Aurora
  • Rallo Capdevila, Miguel
  • Millán Garcia-Varela, M. Sagrario
Purpose: To assess the impact of the quasi-monochromatic illumination on visual acuity (VA) in phakic and monofocal pseudophakic eyes using different wavelengths. Methods: Sixty-one eyes classified in two groups (phakic and pseudophakic) participated in this study: 31 young phakic and 30 pseudophakic implanted with an acrylic monofocal intraocular lens. Distance VA was measured with custom optotype illuminated sequentially with three LED lights of nominal wavelengths (B) 455nm, (G) 530nm, (R) 625nm and white (W) LED light (CCT= 6500K). Near VA was additionally assessed in young phakic eyes under the same illuminations. Results: Best mean distance VA was obtained under red and white lights in young phakic eyes, whereas it was obtained under white and green lights in pseudophakic eyes. For both groups, the blue illumination led to the worst mean distance VA outcomes. No significant differences were found among mean near VA for R, G an B lights, but it was significantly better under W light than under B light. Conclusion: The measured distance VA values reveal the impact of the chromatic difference of refraction caused by the longitudinal chromatic aberration of the tested eyes. This aberration, is compensated by the accommodation capability of young phakics under red light. In the case of monofocal elderly pseudophakic eyes, a natural age-related decrease in the VA is observed. Additionally, the lack of accommodation, and a postoperative refraction outcome likely targeted for a green design wavelength, make the mean distance VA under green light match the one under white light. The mean near VA results in young phakic subjects revealed a balanced accommodation capability to every R, G, B illumination, but significantly higher under W light than under B light., This work was supported by the Spanish Ministerio de Economía y Competitividad and FEDER funds under project Ref. DPI2016-76019-R., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Removing dust artifacts in retinal images via dictionary learning and sparse-based inpainting

  • Barrios Montes, Erik Miguel
  • Marrugo Hernandez, Andrés Guillermo
  • Millán Garcia-Varela, M. Sagrario
In the field of ophthalmology, retinal images are essential for the diagnosis of many diseases. These images are acquired with a device called the retinal camera. However, often small dust particles in the sensor produce image artifacts that can be confused with small lesions, such as micro-aneurysms. The digital removal of artifacts can be understood as an inpainting process in which a set of pixels are replaced with a value obtained from the surrounding area. In this paper, we propose a methodology based on the sparse representations and dictionary learning for the removal of artifacts in retinal images. We test our method on real retinal images coming from the clinical setting with actual dust artifacts. We compare our restoration results with a diffusion-based inpainting technique. Encouraging experimental results show that our method can successfully remove the artifacts, while assuring the continuity of the retinal structures, like blood vessels., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Dust particle artifact detection and removal in retinal images

  • Sierra, E.
  • Marrugo Hernandez, Andrés Guillermo
  • Millán Garcia-Varela, M. Sagrario
Retinal fundus cameras suffer from dust particles attaching to the sensor and lens, which manifest as small artifacts on the images. We propose a new strategy for the detection and removal of dust particle artifacts in retinal images. We consider as input two or more color fundus images acquired within the same session, in which we assume the artifacts remain in the same position. Our method consists in detecting candidate artifacts via normalized cross correlation with an artifact template, performing segmentation via region growing, and comparing the segmentations in all images. This guarantees that all detections are consistent for all images. The removal stage consists in an inpainting procedure so that the new region does not stand out from the neighboring regions. Encouraging experimental results show the localization of artifacts is effective and the artifacts are successfully removed, while not introducing new artifacts in the color retinal images., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Correlation between polychromatic image quality metrics to predict visual acuity in pseudophakic patients

  • Armengol Cebrian, Jesús
  • Garzon, Nuria
  • Vega Lerín, Fidel
  • Altemir Gómez, I.
  • Millán Garcia-Varela, M. Sagrario
The optical quality of three multifocal intraocular lenses (MIOLs) was measured in vitro using the area under the modulation transfer function (MTFa) and energy efficiency (EE). We evaluated those metrics through-focus (TF) by axially scanning the image space with three wavelengths (R, G, B). High linear correlation between MTFa and EE was found for all cases. Correlations between optical in vitro results (polychromatic TF-MTFa and TF-EE) and clinical visual acuity (VA) defocus curves for the three MIOLs allowed us to derive mathematical expressions. Both metrics proved to be equivalent to predict postoperative VA., Spanish Ministerio de Economía y Competitividad y fondos FEDER (DPI2016-76019-R), Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Pupil size differences between female and male patients after cataract surgery

  • Ordiñaga Monreal, Enrique
  • Castanera Gratacós, Diego
  • Castanera de Molina, Fernando
  • Fambuena Muedra, Isabel
  • Vega Lerín, Fidel
  • Millán Garcia-Varela, M. Sagrario
Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pupils, the male group had greater reduction in their postoperative pupillary diameter, -0.56 mm (-12.4%), than the female group, -0.38 mm (-8.2%), P = 0.025. Photopic postoperative pupils reduced to a lesser extent, yet more in men than in women (-0.11mm [-4.5%] vs. -0.04 [-1.6%], P = 0.048). Weak significant negative correlation was found between photopic pupillary changes in women with age (r = -0.24, P = 0.041), and positive correlation for mesopic pupillary changes in men with age (r = +0.34, P = 0.039). Conclusions Patients experience pupil reduction after cataract surgery in general, but more in men than in women and for both photopic and mesopic lighting conditions. The differences are statistically significant and have moderate clinical relevance. Concerning pupillary changes, weak but opposite sign correlations were found between male/female gender and age., This work was supported by the Spanish Ministerio de Economía y Competitividad and FEDERfunds under project Ref. DPI2016-76019-R, Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Toward and ophtalmic imaging system with extended depth of focus using the asymmetric phase mask

  • Romero Pérez, Lenny Alexandra
  • Marrugo Hernandez, Andrés Guillermo
  • Millán Garcia-Varela, M. Sagrario
We study the trade-off of extending the depth-of-focus with an asymmetric phase mask optical element and the decrease of image quality in terms of a numerical optimization scheme that could be used in ophthalmic imaging systems., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Efecto del centrado de retinografías en los índices de tortuosidad de los vasos sanguíneos

Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Integration of the photon-counting technique and a joint transform correlator to encrypt and authenticate images

Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Clinical assessment of chromatic aberration in phakic and pseudophakic eyes

  • Millán Garcia-Varela, M. Sagrario
  • Vega Lerín, Fidel
  • Garzon, Nuria
We present a psychophysical method and a simple setup for the clinical assessment of the longitudinal chromatic aberration (LCA) in phakic and pseudophakic eyes. A proof of concept built from inexpensive and non-sophisticated optomechanical components were used to obtain the preliminary clinical results presented in this work, Peer Reviewed, Postprint (published version)