Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biocompatibility and Electrical Stimulation of Skeletal and Smooth Muscle Cells Cultured on Piezoelectric Nanogenerators

  • Blanquer, Andreu
  • Careta, Oriol
  • Anido-Varela, Laura
  • Aranda, Aida
  • Ibáñez, Elena
  • Esteve, Jaume
  • Nogués, Carme
  • Murillo Rodríguez, Gonzalo
Nanogenerators are interesting for biomedical applications, with a great potential for electrical stimulation of excitable cells. Piezoelectric ZnO nanosheets present unique properties for tissue engineering. In this study, nanogenerator arrays based on ZnO nanosheets are fabricated on transparent coverslips to analyse the biocompatibility and the electromechanical interaction with two types of muscle cells, smooth and skeletal. Both cell types adhere, proliferate and differentiate on the ZnO nanogenerators. Interestingly, the amount of Zn ions released over time from the nanogenerators does not interfere with cell viability and does not trigger the associated inflammatory response, which is not triggered by the nanogenerators themselves either. The local electric field generated by the electromechanical nanogenerator-cell interaction stimulates smooth muscle cells by increasing cytosolic calcium ions, whereas no stimulation effect is observed on skeletal muscle cells. The random orientation of the ZnO nanogenerators, avoiding an overall action potential aligned along the muscle fibre, is hypothesised to be the cause of the cell-type dependent response. This demonstrates the need of optimizing the nanogenerator morphology, orientation and distribution according to the potential biomedical use. Thus, this study demonstrates the cell-scale stimulation triggered by biocompatible piezoelectric nanogenerators without using an external source on smooth muscle cells, although it remarks the cell type-dependent response., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Piezoelectric MEMS resonator with magnetic tip mass for energy harvesting from ultra-low intensity magnetic fields

  • Duque, Marcos
  • Murillo Rodríguez, Gonzalo
This article addresses the limitation in the implementation of the Internet of Things (IoT) due to its energy dependence on batteries. The central focus of this work is the development and characterization of a magnetoelectric (ME) energy generator for IoT, which combines a piezoelectric microelectromechanical system (MEMS) with a magnetic mass to interact with ambient magnetic fields (MFs). The device's efficiency is validated through finite element modeling (FEM) simulations and electrical characterization. Its applicability in environments with residual magnetic fields, such as near common household appliances, highlights its viability. Specific results, such as a maximum generated power of 0.55 µW, corresponding to a power density of 9.19 µW/cm³, for a magnetic field strength of 5 µT, emphasize its ability to address energy challenges and promote the sustainable autonomy of IoT., Funding text 1 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL (www.energiot.com), who holds part of the intellectual property and is funded by the European Union under the Silicon Eurocluster project (101074552), and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona. Funding text 2 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL ( www.energiot.com ), who holds part of the intellectual property, and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Replication data for Piezoelectric MEMS resonator with magnetic tip mass for energy harvesting from ultra-low intensity magnetic fields

  • Duque, Marcos
  • Murillo Rodríguez, Gonzalo
This article addresses the limitation in the implementation of the Internet of Things (IoT) due to its energy dependence on batteries. The central focus of this work is the development and characterization of a magnetoelectric (ME) energy generator for IoT, which combines a piezoelectric microelectromechanical system (MEMS) with a magnetic mass to interact with ambient magnetic fields (MFs). The device's efficiency is validated through finite element modeling (FEM) simulations and electrical characterization. Its applicability in environments with residual magnetic fields, such as near common household appliances, highlights its viability. Specific results, such as a maximum generated power of 0.55 µW, corresponding to a power density of 9.19 µW/cm³, for a magnetic field strength of 5 µT, emphasize its ability to address energy challenges and promote the sustainable autonomy of IoT., Funding text 1 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL (www.energiot.com), who holds part of the intellectual property and is funded by the European Union under the Silicon Eurocluster project (101074552), and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona. Funding text 2 G. Murillo thanks the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), the national projects PID2020-119350RA-I00, EUR2020-112082 and CNS2022-136065, under the Dynamization Actions \"Europa Excelencia 2020\u201D and the Consolidation Actions funded by the NextGenerationEU Instrument and Ramon y Cajal Fellowship 2020 (RYC2020-030501-I). This work has been carried out in collaboration with ENERGIOT DEVICES SL ( www.energiot.com ), who holds part of the intellectual property, and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multiplex Sensing Electronic Skin Based on Seamless Fully Printed Stretchable Piezoelectric Devices

  • Alique, Marc
  • Moya, Ana
  • Otero, David
  • Kreuzer, Martin
  • Lacharmoise, Paul
  • Murillo, Gonzalo
  • Delgado Simao, Claudia
Wearable skin mountable devices, more than flexibility, require conformability, stretchability, and a high water vapor transmission rate, so that the perspiration processes are not blocked, to assure comfort and stability of use in contact with living bodies. Skin mountable stretchable devices with piezoelectric devices have been reported, based on the integration of polyvinylidene fluoride foils with discrete electrodes and stretchable substrates, and show potential in revolutionizing medical devices for remote monitoring applications. However, the electrodes and active layer are usually not stretchable, only the carrier substrate. The study reports the full description of a novel fully printed stretchable piezoelectric device, printed directly over a stretchable polymer foil of thermoplastic polyurethane. The stability of the response of the stretchable piezoelectric devices is used as movement sensors through their output potential. An electronic skin based on a fully printed circuit with a matrix of 15 all-printed piezoelectric devices is prepared and investigated and used directly mounted on different body parts, and the real-time monitoring of movements are recorded and analyzed., M.A. is a fellow of Eurecat “Vicente Lopez” PhD grant program. This work was financially supported by the Catalan Government through the funding grant ACCIÓ-Eurecat. G.M. thanks the financial support from La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010) and EUR2020-112082 under the Dynamization Actions Europa Excelencia 2020 funded by NextGenerationEU Instrument. The FTIR experiments were performed at MIRAS beamline at ALBA Synchrotron with the collaboration of ALBA staff. The GIWAXS experiments were performed at NCD-SWEET beamline at ALBA Synchrotron with the collaboration of ALBA staff. All experiments involving human participants were carried out with their informed consent., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tapping-Actuated Triboelectric Nanogenerator with Surface Charge Density Optimization for Human Motion Energy Harvesting

  • Duque, Marcos
  • Murillo, Gonzalo
In this article, triboelectric effect has been used to harvest mechanical energy from human motion and convert it into electrical energy. To do so, different ways of optimizing the energy generated have been studied through the correct selection of materials, the design of new spacers to improve the contact surface area, and charge injection by high-voltage corona charging to increase the charge density of dielectric materials. Finally, a triboelectric nanogenerator (TENG) has been manufactured, which is capable of collecting the mechanical energy of the force applied by hand tapping and using it to power miniaturized electronic sensors in a self-sufficient and sustainable way. This work shows the theoretical concept and simulations of the proposed TENG device, as well as the experimental work carried out., G.M. appreciates the financial support from the La Caixa Foundation under the Junior Leader Retaining Fellowship (LCF/BQ/PR19/11700010), project EUR2020-112082 under the Dynamization Actions “Europa Excelencia 2020” funded by the NextGenerationEU Instrument, and the Ramon y Cajal Fellowship 2020. This work has been carried out in collaboration with ENERGIOT DEVICES SL (www.energiot.com) and in the framework of the doctoral program in Electronic and Telecommunication Engineering of the Autonomous University of Barcelona., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

ZnO Nanosheet-Coated TiZrPdSiNb Alloy as a Piezoelectric Hybrid Material for Self-Stimulating Orthopedic Implants

  • Careta, Oriol|||0000-0003-1333-0300
  • Esteve, Jaume|||0000-0001-9440-7984
  • Sort, Jordi|||0000-0003-1213-3639
  • Murillo, Gonzalo|||0000-0002-0368-1900
  • Nogués, Carme|||0000-0002-6361-8559
  • Fornell Beringues, Jordina|||0000-0002-0909-3843
  • Pellicer, Eva|||0000-0002-8901-0998
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Blanquer, Andreu|||0000-0002-3551-1885
A Ti-based alloy (Ti45Zr15Pd30Si5Nb5) with already proven excellent mechanical and biocompatibility features has been coated with piezoelectric zinc oxide (ZnO) to induce the electrical self-stimulation of cells. ZnO was grown onto the pristine alloy in two different morphologies: a flat dense film and an array of nanosheets. The effect of the combined material on osteoblasts (electrically stimulable cells) was analyzed in terms of proliferation, cell adhesion, expression of differentiation markers and induction of calcium transients. Although both ZnO structures were biocompatible and did not induce inflammatory response, only the array of ZnO nanosheets was able to induce calcium transients, which improved the proliferation of Saos-2 cells and enhanced the expression of some early differentiation expression genes. The usual motion of the cells imposes strain to the ZnO nanosheets, which, in turn, create local electric fields owing to their piezoelectric character. These electric fields cause the opening of calcium voltage gates and boost cell proliferation and early differentiation. Thus, the modification of the Ti45Zr15Pd30Si5Nb5 surface with an array of ZnO nanosheets endows the alloy with smart characteristics, making it capable of electric self-stimulation.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biocompatibility and Electrical Stimulation of Skeletal and Smooth Muscle Cells Cultured on Piezoelectric Nanogenerators

  • Blanquer, Andreu|||0000-0002-3551-1885
  • Careta, Oriol|||0000-0003-1333-0300
  • Anido-Varela, Laura
  • Aranda, Aida
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Esteve, Jaume|||0000-0001-9440-7984
  • Nogués, Carme|||0000-0002-6361-8559
  • Murillo, Gonzalo|||0000-0002-0368-1900
Nanogenerators are interesting for biomedical applications, with a great potential for electrical stimulation of excitable cells. Piezoelectric ZnO nanosheets present unique properties for tissue engineering. In this study, nanogenerator arrays based on ZnO nanosheets are fabricated on transparent coverslips to analyse the biocompatibility and the electromechanical interaction with two types of muscle cells, smooth and skeletal. Both cell types adhere, proliferate and differentiate on the ZnO nanogenerators. Interestingly, the amount of Zn ions released over time from the nanogenerators does not interfere with cell viability and does not trigger the associated inflammatory response, which is not triggered by the nanogenerators themselves either. The local electric field generated by the electromechanical nanogenerator-cell interaction stimulates smooth muscle cells by increasing cytosolic calcium ions, whereas no stimulation effect is observed on skeletal muscle cells. The random orientation of the ZnO nanogenerators, avoiding an overall action potential aligned along the muscle fibre, is hypothesised to be the cause of the cell-type dependent response. This demonstrates the need of optimizing the nanogenerator morphology, orientation and distribution according to the potential biomedical use. Thus, this study demonstrates the cell-scale stimulation triggered by biocompatible piezoelectric nanogenerators without using an external source on smooth muscle cells, although it remarks the cell type-dependent response.