Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 23
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array

  • Alvarez, V.
  • Borges, F. I. G.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Marí Romero, Antonio Francisco
  • Palma, R,
  • Pérez Aparicio, José Luis
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas, demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Q(beta beta)).© 2013 IOP Publishing Ltd and Sissa Medialab srl., This work was supported by the following agencies and institutions: the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The electronics of the energy plane of the NEXT-White detector

  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Laing, A.
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
  • Monrabal, Francesc
  • Gómez-Cadenas, J.J.
[EN] This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit(-1) in the chain of Bi-214. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4mV., We acknowledge support from the following agencies and institutions: the European Research Council (ERC), Spain under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program, Spain SEV-2014-0398 and the Maria de Maetzu Program, Spain MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER, Spain through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We acknowledge partial support from the European Union Horizon 2020 research and innovation programme, Spain under the Marie Sklodowska-Curie grant agreements No. 690575 and 674896. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic Xe-137 in xenon gas experiments using He-3 neutron capture

  • Rogers, L.
  • Jones, B. J. P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I. J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Xe-136 is used as the target medium for many experiments searching for 0 nu beta beta. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of Xe-137 created by the capture of neutrons on Xe-136. This isotope decays via beta decay with a half-life of 3.8 min and a Q(beta) of similar to 4.16 MeV. This work proposes and explores the concept of adding a small percentage of He-3 to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from Xe-137 activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory., The work described was supported by the Department of Energy under Award numbers DE-SC0019054 and DE-SC0019223. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under the Marie Skodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

  • Ferrario, P.
  • Laing, A.
  • Lopez-March, N.
  • Gomez-Cadenas, J. J.
  • Azevedo, C. D. R.
  • Borges, F.I.G.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • C.A.N. Conde
  • Dafni, T.
  • Diaz, J.
  • Diesburg, M.
  • Pérez-Aparicio, José L.
  • Querol, M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qββ . This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22Na 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the 228Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1.% for signal events., This work was supported by the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; and the Fermi National Accelerator Laboratory under U.S. Department of Energy Contract No. DE-AC02-07CH11359
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterisation of NEXT-DEMO using xenon Ka X-rays

  • Lorca, D.
  • Martín Albo, J.
  • Laing, A.
  • Ferrario, P.
  • Gómez Cadenas, J.J.
  • Álvarez, V.
  • Borges, F.I.G.
  • Camargo, M.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Marí Romero, Antonio Francisco
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Pérez Aparicio, José Luis
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon K-shell X-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a 1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using Ka X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from 22Na., This work was supported by the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

PMT calibration of a scintillation detector using primary scintillation

  • Freitas, E. D. C.
  • Fernandes, L. M. P.
  • Yahlali, N.
  • Perez, J.
  • Alvarez, V.
  • Borges, F. I. G.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Marí Romero, Antonio Francisco
  • Pérez Aparicio, José Luis
  • Rodríguez Samaniego, Javier
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
We have studied the calibration of PMTs in scintillation detectors, inducing single electron response on the PMT from primary scintillation produced by x-ray interaction. The results agree with those obtained by the commonly used single electron response (SER) method, which uses LED light pulses to induce the PMT SER. The use of the primary scintillation for PMT calibration will be convenient in situations where the PMT is already in situ, when it becomes difficult or even impossible to apply the SER method, e.g. in commercial sealed scintillator/PMT devices. Furthermore, we have experimentally investigated the possibility of fitting the high-charge tail of the PMT SER pulse-height distribution to an exponential function, inferring the PMT gain from the inverse of the exponent. The results of the exponential fit method agree with those obtained by the SER method for pulse-height distributions resulting from an average number of around 1.0 photoelectrons reaching the first dynode per light/scintillation pulse. The SER method has higher precision and, therefore, is used in a larger number of applications. Nevertheless, the exponential fit method will be useful in situations where the single photoelectron peak is under the background or noise peak and it may present an alternative, simple way, for relative gain calibration of PMT arrays as well as for monitoring the PMT gain variations., The NEXT experiment is supported by the following agencies and institutions: the European Research Funding through an ERC Advanced Grant (NEXT 2013); Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008- 0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04; the Portuguese FCT and FEDER through program COMPETE, project PTDC/FIS/103860/2008. C.M.B. Monteiro acknowledges grant SFRH/BPD/76842/2011 from FCT.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ionization and scintillation of nuclear recoils in gaseous xenon

  • Renner, J.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Matis, H. S.
  • Miller, T.
  • Nakajima, Y.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Shuman, D.
  • Alvarez, V.
  • Borges, F. I. G.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Diaz, J.
  • Evtoukhovitch, P.
  • Fernandes, L. M. P.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gomez, H.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D. C.
  • Iguaz, F. J.
  • Irastorza, I. G.
  • Jinete, M. A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J. A. M.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Mari, A.
  • Martin-Albo, J.
  • Martinez, A.
  • Moiseenko, A.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Palma, R.
  • Perez, J.
  • Pérez Aparicio, José Luis
  • Ripoll, L.
  • Rodriguez, A.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Segui, L.
  • Serra, L.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Tomas, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Gil, A.|||0000-0001-7192-6992
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
Abstract Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope α-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments., This work was supported by the following agencies and institutions: the Director, Office of Science, Office of Basic Energy Sciences, of the U.S. Department of Energy, and the National Energy Research Scientific Computing Center (NERSC), supported by the Office of Science of the U.S. Department of Energy, both under Contract no. DE-AC02-05CH11231; the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under Grants CONSOLIDER-Ingenio 2010 C5D2008-0037 (CUP), FPA2009-13697-004-04, FPA2009-13697-C04-01, FIS2012-37947-C04-01, FIS2012-37947-C04-02, FIS2012-37947-C04-03, and FIS2012-37947-C04-04; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner acknowledges the support of a Department of Energy National Nuclear Security Administration Stewardship Science Graduate Fellowship, grant number DE-FC52-08NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Radio Frequency and DC High Voltage Breakdown of High Pressure Helium, Argon, and Xenon

  • Woodruff, K.
  • Baeza-Rubio, J.
  • Huerta, D.
  • Jones, B. J. P.
  • McDonald, A. D.
  • Norman, L.
  • Nygren, D. R.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I. J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Results of the material screening program of the NEXT experiment

  • Dafni, T.
  • Bandac, I.
  • Bettini, A.
  • Borges, F. I. G. M.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Diaz, J.
  • Fernandes, L. M. P.
  • Fernandez, M.
  • Ferrario, P.
  • Pérez-Aparicio, José L.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium γ-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo de revisión (ReviewArticle)

Measurement of energy resolution with the NEXT-White silicon photomultipliers

  • Contreras, T.
  • Palmeiro, B.
  • Almazán, H.
  • Para, A.
  • Martinez-Lema, G.
  • Guenette, R.
  • Adams, C.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F.
  • Ayet, S.
  • Azevedo, C.D.R.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses 83mKr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9±0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the JHEP09(2024)112 noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union’s Framework Programme for Research and Innovation, Horizon 2020 (2014–2020), under Grant Agreement No. 957202-HIDDEN; Spain’s MCIN/AEI and the ERDF (“A way of making Europe”) under grants PID2021-125475NB and the Severo Ochoa Programme grant CEX2018-000867-S; the Generalitat Valenciana (Spain) under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government (Spain) under the predoctoral training programme for non-doctoral research personnel; the “la Caixa” Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese Foundation for Science and Technology (FCT) under project UID/FIS/04559/2020 supporting the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19, and 465; the U.S. Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (The University of Texas at Arlington), and DE-SC0019223 (The University of Texas at Arlington); the U.S. National Science Foundation under award NSF CHE-2004111; and the Robert A. Welch Foundation under award Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterráneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays

  • Álvarez, V.
  • Borges, F.I.G.M.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí Romero, Antonio Francisco
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, F.
  • Monteiro C.M.B.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, D.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Pérez, J.
  • Pérez Aparicio, José Luis
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Vázquez, D.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
  • Aznar, F.
  • Calvet, D.
  • Druillole, F.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gracia, J.
  • Le Coguie, A.
  • Mols, J.P.
  • Pons, P.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Ruiz, E.
[EN] NEXT-MM is a general-purpose high pressure (10 bar, ∼25 l active volume) Xenon- based TPC, read out in charge mode with an 0.8 cm×0.8 cm-segmented 700 cm2 plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT 0νββ experiment, although the experiment s first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy γ -rays emitted by a 241 Am source when interacting with the Xenon gas (Eγ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated α particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6% FWHM@30 keV), NEXT is supported by the following agencies and institutions: the Ministerio de Econom´ıa y Competitividad (MINECO) of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02- 05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52- 08NA28752. The development of NEXT-MM in particular has important contributions from the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; and also MINECO under grants FPA2008-03456, FPA2011-24058 and CPAN under grant CSD2007- 00042. This work would not have been possible without the encouragement of our RD51 colleages and the dedicated effort of R. de Oliveira and his team at CERN to provide these unique detectors. Discussions with O. Sahin, R. Veenhof, S. Biagi and C. Acevedo are greatly acknowledged. DGD gratefully acknowledges the ‘Charpak award’ for this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrian, S.
  • Perez, J.
  • Bandac, I.
  • Labarga, L.
  • Alvarez, V.
  • Barrado, A. I.
  • Bettini, A.
  • Borges, F. I. G. M.
  • Camargo, M.
  • Carcel, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Conde, E.
  • Dafni, T Diaz, J.
  • Fernandes, L. M. P.
  • Fernandez, M.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J. A.
  • Herrera, D. C.
  • Irastorza, I. G.
  • Laing, A.
  • Liubarsky, I.
  • Lopez-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Marí Peláez, Antonio
  • Martin-Albo, J.
  • Martinez, A.
  • Martinez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Munoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Ortiz de Solorzano, A.
  • Pérez Aparicio, José Luis
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Serra, L.
  • Shuman, D.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J. T.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radio-purity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radio pure tracking plane, in direct contact with the gas detector medium, was a challenge since the needed components have typically activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper and silicon photomultipliers., We deeply acknowledge John Murphy and Carl Jackson from SensL Technologies Ltd for their efficient collaboration in the analysis of SiPMs. We very much thank also Vicenzo Mancini from SOMACIS company for the care in the development of radiopure kapton PCBs. Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT and the T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences of the US DoE under Contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by similar to 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economa y Competitividad of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Mara de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015; the U.S. Department of Energy under contracts number DEAC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A& M) and DE-SC0019223/DESC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An improved measurement of electron-ion recombination in high-pressure xenon gas

  • Serra, L.
  • Sorel, M.
  • Alvarez, V.
  • Borges, F. I. G.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Diaz, J.
  • Marí Romero, Antonio Francisco
  • Pérez Aparicio, José Luis
  • Querol Galve, Marcos
  • Webb, Rachel
  • Yahlali Haddou, Nadia
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8% FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be 0:561 0:045, translating into an average energy to produce a primary scintillation photon ofWex = (39:2 3:2) eV., This work was supported by the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Present status and future perspectives of the NEXT experiment

  • Gómez Cadenas. J.J.
  • Álvarez, V.
  • Borges, F.I.G.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cerverá, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • González Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, J.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laig, A.
  • Liubarsky, I.
  • Lopez, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, M.
  • Marí Romero, Antonio Francisco
  • Martín Albo, J.
  • Martínez, A.
  • Miller, T.
  • Moissenko, A.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot Guínot, M.
  • Nygren, D.
  • Oliviera, C.A.B.
  • Palma, R.
  • Pérez, Javier
  • Pérez Aparicio, José Luis
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Seguí, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.
  • Yahlali Haddou, Nadia
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the 136Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolutionbetter than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1 ton-scale experiment., This work was supported by the following agencies and institutions: the Ministerio de Economia y Competitividad of Spain under Grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences of the US Department of Energy under Contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under Contract no. DE-FC52-08NA28752. J. J. Gomez-Cadenas is a spokes person.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The front-end electronics for the 1.8-kchannel SiPM tracking plane in the NEW detector

  • Rodríguez, Javier
  • Lorca, D.
  • Monrabal, F.
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Esteve Bosch, Raul|||0000-0002-1289-6938
[EN] NEW is the first phase of NEXT-100 experiment, an experiment aimed at searching for neutrinoless double-beta decay. NEXT technology combines an excellent energy resolution with tracking capabilities thanks to a combination of optical sensors, PMTs for the energy measurement and SiPMs for topology reconstruction. Those two tools result in one of the highest background rejection potentials in the field. This work describes the tracking plane that will be constructed for the NEW detector which consists of close to 1800 sensors with a 1-cm pitch arranged in twenty- eight 64-SiPM boards. Then it focuses in the development of the electronics needed to read the 1800 channels with a front-end board that includes per-channel differential transimpedance input amplifier, gated integrator, automatic offset voltage compensation and 12-bit ADC. Finally, a de- scription of how the FPGA buffers data, carries out zero suppression and sends data to the DAQ interface using CERN RD-51 SRS s DTCC link specification complements the description of the electronics of the NEW detector tracking plane., The authors would like to acknowledge the collaboration of the membership of the NEXT experiment. The European Commision under the European Research Council 2013 Advanced Grant 339787 - NEXT, the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04-04 (also co-financed by FEDER). The Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Present status and future perspectives of the NEXT experiment

  • Gomez-Cadenas, J.J.
  • Alvarez, V.
  • Borges, F.I.G.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Condeb, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Diaz, J.
  • Egorov, M.
  • Esteve, R.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreirag, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gomez, H.
  • Gonzalez-Diaz, D.
  • Gutierrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Mari, A.
  • Martin-Alboa, J.
  • Martinez, A.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Perez, J.
  • Perez Aparicio, J.L.
  • Renner, J.
  • Ripoll, L.
  • Rodriguez, A.
  • Rodriguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Tomas, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the 136Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolutionbetter than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1 ton-scale experiment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays

  • Álvarez, V.
  • Borges, F.I.G.M.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Esteve R.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natalda Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Pérez, J.
  • Pérez Aparicio, J.L.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Vázquez, D.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
  • Aznar, F.
  • Calvet, D.
  • Druillole, F.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gracia, J.
  • Le Coguie, A.
  • Mols, J.P.
  • Pons, P.
  • Ruiz, E.
NEXT-MM is a general-purpose high pressure (10 bar, 25 l active volume) Xenonbased TPC, read out in charge mode with an 0:8 cm 0:8 cm-segmented 700 cm2 plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT 0nbb experiment, although the experiment’s first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy g- rays emitted by a 241Am source when interacting with the Xenon gas (Eg = 26, 30, 59:5 keV). The localized nature of such events around atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated a particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly 2014 JINST 9 C04015 due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Results of the material screening program of the NEXT experiment

  • Dafni, T.
  • Álvarez, V.
  • Bandac, I.
  • Bettini, A.
  • Borges, F.I.G.M.
  • Camargo, M.
  • Cárcel, S.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Fernández, M.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Pérez, J.
  • Pérez Aparicio, J.L.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate neutrinoless double beta decay, requi- res extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium ¿-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrián, S.
  • Pérez, J.
  • Bandac, I.
  • Labarga, L.
  • Álvarez, V.
  • Barrado, A.I.
  • Bettini, A.
  • Borges, F.I.G.M.
  • Camargo, M.
  • Cárcel, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Conde, E.
  • Dafni, T.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Fernández, M.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Morata, J.A.H.
  • Herrera, D.C.
  • Irastorza, I.G.
  • Laing, A.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Ortiz de Solórzano, A.
  • Aparicio, J.L.P.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Santos, J.M.F.D.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
The ``Neutrino Experiment with a Xenon Time-Projection Chamber'' (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr'aneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8×10-4 counts keV-1 kg-1 y-1, have been identified.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

  • Ferrario, P.
  • Laing, A.
  • López-March, N.
  • Gómez-Cadenas, J. J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R. M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J. A.
  • Irastorza, I.G.
  • Labarga, L.
  • Lebrun, P.
  • Liubarsky, I.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Nebot-Guinot, M
  • Novella, P.
  • Nygren, D.
  • Para, A.
  • Pérez, J.
  • Pérez Aparicio, J. L.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J. M. F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Yepes-Ramírez, H.
The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qßß. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22Na 1275 keV gammas and electron- positron pairs produced by conversions of gammas from the 228Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1.% for signal events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The NEXT experiment

  • Gomez-Cadenas, J.J.
  • on behalf of the NEXT collaboration
NEXT (Neutrino Experiment with a Xenon TPC) is an experiment to search neutrinoless double beta decay processes (ßß0¿ßß0¿). The isotope chosen by NEXT is 136Xe. The NEXT technology is based in the use of time projection chambers operating at a typical pressure of 15 bar and using electroluminescence to amplify the signal (HPXe). The main advantages of the experimental technique are: a) excellent energy resolution; b) the ability to reconstruct the trajectory of the two electrons emitted in the decays, a unique feature of the HPXe which further contributes to the suppression of backgrounds; c) scalability to large masses; and d) the possibility to reduce the background to negligible levels thanks to the barium tagging technology (BaTa). The NEXT roadmap was designed in four stages: i) Demonstration of the HPXe technology with prototypes deploying a mass of natural xenon in the range of 1 kg; ii) Characterisation of the backgrounds to the ßß0¿ßß0¿ signal and measurement of the ßß2¿ßß2¿ signal with the NEW detector, deploying 10 kg of enriched xenon and operating at the LSC; iii) Search for ßß0¿ßß0¿ decays with the NEXT-100 detector, which deploys 100 kg of enriched xenon; iv) Search for ßß0¿ßß0¿ decays with the BEXT detector, which will deploy masses in the range of the ton and will introduce two additional handles, only possible in a HPXe: a) A magnetic field, capable of further enhancing the topological signal of NEXT; and b) barium-tagging (a technique pioneered by the EXO experiment which is also accessible to NEXT). The first stage of NEXT has been successfully completed during the period 2009–2013. The prototypes NEXT-DEMO (IFIC) and NEXT-DBDM (Berkeley) were built and operated for more than two years. These apparatuses have demonstrated the main features of the technology. The experiment is currently developing its second phase. The NEW detector is being constructed during 2014 and will operate in the LSC during 2015. The NEXT-100 detector will be built and commissioned during 2016 and 2017 and will start data taking in 2018. NEXT-100 could discover ßß0¿ßß0¿ processes if the period of the decay is equal or less than 6×10256×1025 year. The fourth phase of the experiment (BEXT) could start in 2020.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Backgrounds and sensitivity of the NEXT double beta decay experiment

  • Nebot-Guinot, M.
  • Ferrario, P.
  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Gómez-Cadena, J.J.
  • on behalf of the NEXT Collaboration
NEXT (Neutrino Experiment with a Xenon TPC) is a neutrinoless double-beta (ßß0¿ßß0¿) decay experiment that will operate at the Canfranc Underground Laboratory (LSC). It is an electroluminescent high-pressure gaseous xenon Time Projection Chamber (TPC) with separate read-out planes for calorimetry and tracking. Energy resolution and background suppression are the two key features of any neutrinoless double beta decay experiment. NEXT has both good energy resolution (<1% FWHM) at the Q value of 136Xe and an extra handle for background identification provided by track reconstruction. With the background model of NEXT, based on the detector simulation and the evaluation of the detector radiopurity, we can determine the sensitivity to a measurement of the ßß2¿ßß2¿ mode in NEW and to a ßß0¿ßß0¿ search in NEXT100. In this way we can predict the background rate of 5×10-4 counts/(keV kg yr)5×10-4 counts/(keV kg yr), and a sensitivity to the Majorana neutrino mass down to 100 meV after a 5-years run of NEXT100.