Skip to main content

Interacción de iones rápidos con inestabilidades magnetohidrodinámicas en plasmas de fusión

FJC2019-041092-I

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Juan de la Cierva Formación
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE SEVILLA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization of scintillator screens under irradiation of low energy 133Cs ions

  • Toledo Garrido, Juan José
  • Galdón Quiroga, Joaquín
  • Viezzer, Eleonora
  • Birkenmeier, Gregor
  • Olevskaia, V.
  • Balden, M.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Rodríguez-Ramos, M.
  • Anda, Gábor
  • Videla-Trevin, Micaela
  • García-Muñoz, M.
  • ASDEX Upgrade Team
An imaging heavy ion beam probe (i-HIBP) diagnostic, for the simultaneous measurement of plasma density, magnetic field and electrostatic potential in the plasma edge, has been installed at ASDEX Upgrade. Unlike standard heavy ion beam probes, in the i-HIBP the probing (heavy) ions are collected by a scintillator detector, creating a light pattern or strike-line, which is then imaged by a camera. Therefore, a good characterization of the scintillator response is needed. Previous works focused on the scintillator behaviour against irradiation with light ions such as hydrogen and alpha particles. In this work we present the characterization of several scintillator screens - TG-Green (SrGa2S4:Eu2+), YAG-Ce (Y3Al5O12:Ce3+) and P11 (ZnS:Ag) - against irradiation with 133Cs+ ions, in an energy range between 5 and 70 keV and ion currents between 105 and 107 ions/(s·cm2). Three main properties of the scintillators have been studied: the ionolumenescence efficiency or yield, the linearity and the degradation as a function of the fluence. The highest yield was delivered by the TG-Green scintillator screen with > 8·103 photons/ion at 50 keV. All the samples showed a linear response with increasing incident ion flux. The degradation was quantified in terms of the fluence F1/2, which leads to a reduction of the emissivity by a factor of 2. TG-Green showed the lowest degradation with F1/2= 5.4·1014 ions/cm2. After the irradiation the samples were analyzed by Scanning Electron Microscopy (SEM), Rutherford Backscattering Spectrometry (RBS) and Particle Induced X-ray Emission (PIXE). No trace of Cs was found in the irradiated regions. These results indicate that, among the tested materials, TG-Green is the best candidate for the i-HIBP detector., This work received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No. 805162). G. Birkenmeier acknowledges funding from the Helmholtz Association under grant no. VHNG-1350. J. Galdon-Quiroga acknowledges funding from the Spanish Ministry of Science and Innovation under grant no. FJC2019-041092-I.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

  • Vuuren, A. Jansen van
  • Lazerson, S. A.
  • LeViness, A.
  • García-Muñoz, M.
  • Gates, David
  • Galdón Quiroga, Joaquín
  • Hidalgo-Salaverri, Javier
  • Rueda-Rueda, José
  • García-Domínguez, J.
  • Ayllón Guerola, Juan Manuel
A conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co- and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity-space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution., EUROfusion Consortium 10.13039/100018708-European Union via the Euratom Research and Training Programme (Grant Number: 101052200–EUROfusion) 10.13039/501100004837-Ministerio de Ciencia e Innovación (Grant Number: FJC-2019-041092-I)