Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Rate of injection measurements of a direct-acting piezoelectric injector for different operating temperatures

  • Payri, Raul|||0000-0001-7428-5510
  • Gimeno, Jaime|||0000-0003-3317-9994
  • Mata, Carmen
  • Viera-Sotillo, Alberto Antonio
[EN] As the regulations for pollutant emissions in diesel engines are increasingly restrictive, the introduction of the piezoelectric direct-acting injectors seeks to improve the overall efficiency of the injection system, and consequently reduce combustion contaminants. In such systems, the needle lift is governed by the charge, or voltage, applied to the piezo stack, allowing for a more precise control over the fuel injection process. Although it is known that the performance of the piezoelectric crystals depends on its temperature of operation, the effect this has on the rate of injection is still unclear. In this research, a particular setup was used to measure the rate of injection of a direct-acting injector for different operating temperatures. It was mounted into an injection discharge rate curve indicator with a particular holder that has a cooling sleeve connected to a circuit running ethylene glycol, which is driven by a thermoregulator unit. A parametric sweep of different piezo stack control voltages for three rail pressures and operating temperatures was carried out. On the results, when needle lift does not influence internal flow development, the rate of injection was controlled by the injection pressure, with minimal impact from the working temperature, resembling results from conventional hydraulic injectors. At partial needle lift, two operating regions were observed, delimited by a particular voltage level. Above it, the needle throttling was able to control mass fuel flow accurately. But below it, the stabilized rate of injection values decreased drastically. The rate of this decline was dependent only on the injection pressure. The threshold level, named critical voltage, increased linearly with increasing injection pressure and working temperature. Also, to maintain a constant fuel mass flow for decreasing operating temperature, the voltage level of the control signal had to be reduced. These results highlight the importance of monitoring and controlling the operating conditions of the direct-acting injectors, as their performance and efficiency are both influenced by the working temperature of the piezo stack., This research has been partially funded by FEDER and Spanish Ministerio de Economía y Competitividad through project TRA2015-67679-c2-1-R. Additionally, financial support to Dr. Carmen Mata was provided by Ayudas para estancias en otras universidades y centros de investigación 2017 of Universidad de Castilla la Mancha. Likewise, Alberto Viera is supported through the FPI contract 2016-S2-1361 of Programa de Apoyo para la Investigación y Desarrollo (PAID) of Universitat Poltècnica de València.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Measurements of the mass allocation for multiple injection strategies using the rate of injection and momentum flux signals

  • Payri, Raul|||0000-0001-7428-5510
  • Gimeno, Jaime|||0000-0003-3317-9994
  • Marti-Aldaravi, Pedro|||0000-0003-4650-4004
  • Viera, Alberto
[EN] As legislations set very stringent environmental and fuel economy standards, researchers have pushed into a continuous development in all areas of the diesel engine. The recent evolution of the injection technologies has permitted to modify the fuel-delivery strategies. From what was a single pulse per injection event, modern systems allow to inject up to eight different times precisely per combustion cycle. In such sense, experimental results of the rate of injection and momentum flux could be useful for validation and improvement of computational models. Moreover, accurately quantifying the injected mass per pulse in a fuel-gas interface can provide data with more realistic engine-like conditions. To this end, this research presents measurements of the rate of injection and momentum flux for two simple multiple injection strategies: a pilot-main and a main-post. Boundary conditions included two rail and discharge pressures, two different pilot/post quantities and four dwell times. A new approach was employed to estimate the mass allocation with the momentum flux data, and results were compared to the rate of injection traces to verify the distribution calculated. On the results, signals for each pulse were successfully decoupled using its rising and falling edge. The shot-to-shot variability of the pilot/post injection was highly dependent on its transitory characteristics, and on the dwell time for post injections due to internal pressure waves. The injected mass per pulse was successfully measured as well in the momentum flux test rig, and the energizing time changed slightly to account for the different operation interfaces. Signals from both measurement campaigns showed a remarkable agreement when compared, ascertain the possibility of measuring the injected mass, and its allocation for multiple injection strategies, in the momentum flux test rig., The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This research was partially funded by the Spanish Ministerio de Ciencias, Investigacion y Universidades through project RTI2018-099706-B-I00. Part of the experimental hardware was purchased through funds obtained from Generalitat Valenciana and FEDER through project IDIFEDER/2018/037. In addition, A.V. was supported through the FPI contract 2016-S2-1361 of "`Programa de Apoyo para la Investigacion y Desarrollo (PAID)'' of Universitat Poltecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Differences between single and double-pass schlieren imaging on diesel vapor spray characteristics

  • Payri, Raul|||0000-0001-7428-5510
  • Salvador, Francisco Javier|||0000-0003-3269-2251
  • Bracho Leon, Gabriela|||0000-0002-9198-7044
  • Viera-Sotillo, Alberto Antonio
[EN] The use olschlieren imaging at high acquisition rate has been adopted as a standard optical technique for the analysis of vaporizing diesel sprays under engine-like conditions. A single-pass schlieren arrangement is typically used for the study of axially drilled single-orifice nozzles, as vessels with multiple optical accesses regularly allow line of sight visualization. Contrarily, for multi-spray nozzles, measurements are commonly performed through a single,optical access, in which case a double-pass arrangement is employed. As a consequence, the light beams pass through the test section twice, increasing the optical sensitivity of the schlieren setup. However, the influence this has on the macroscopic spray characteristics is still unclear. The scope of this study is to analyze the differences in vapor phase penetration and spreading angle measured for the same injection event, through high-speed imaging, for both single and double-pass schlieren configurations. Experiments were carried out with a three hole nozzle with a nominal orifice diameter of 90 mu m, named Spray B from the Engine Combustion Network, using commercially available diesel fuel and in non-reactive conditions. The impact of different injection pressures, chamber temperatures and densities on the spray captured by each setup was assessed. On the results, vapor. phase penetration and spreading angle followed the expected trend found in the literature, for the different boundary conditions tested. Comparing the optical setups, vapor phase penetration and spreading angle results obtained with the double-pass arrangement were marginally higher than those from the single-pass. The deviation was observed throughout all tested conditions. For spray tip penetration, although the discrepancy was approximately constant for different injection pressures and chamber temperature, it increased with increasing density. These results highlight the importance of a proper understanding regarding the limitations of optical diagnostics, in particular for results used in calibration of computational models. (C) 2017 Elsevier Ltd. All rights reserved., This research has been partially funded by FEDER and Spanish Ministerio de Economia y Competitividad through project TRA2015-67679-C2-1-R. Additionally, Alberto Viera is supported through the FPI contract 2016-S2-1361 of "Programa de Apoyo para la Investigacion y Desarrollo (PAID)" of Universitat Poltecnica de Valencia.