Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Electrochemical biosensor for early Alzheimer's detection and patient risk stratification using plasma exosomes

  • Rossi, Rosanna|||0000-0002-3656-2908
  • Cano, Amanda|||0000-0001-9567-4283
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Ruiz Laza, Agustín|||0000-0003-2633-2495
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
Alzheimer's Disease (AD) is the leading cause of dementia, accounting for 60-70 % of cases worldwide. Early diagnosis remains challenging due to the limitations of current diagnostic tools, which are costly, invasive, and suffer from low patient compliance. Blood-based biomarkers, particularly plasma brain-derived exosomes (BDEs), have emerged as a promising alternative since they carry AD-related molecules and can be isolated non-invasively. In this study, an immunoassay was developed to isolate BDEs using magnetic particles functionalized with an anti-neuroligin-3 (NLGN3) antibody, while the AD-related marker β-secretase (BACE-1) was detected on the captured exosomes. This is the first report combining NLGN3 for for the isolation of BDEs with BACE-1 as a detection target, establishing a novel biomarker panel for AD diagnostics. The assay was evaluated across three readout platforms-optical, chemiluminescent, and electrochemical-with detection limits in the range of 104-105 exosomes μL-1. Among them, the portable electrochemical platform achieved the improved LOD (1.51 × 104 exosomes μL-1, R2 = 0.9829). Plasma samples from patients with AD, mild cognitive impairment (MCI), and healthy controls were analyzed, revealing differences in exosomal BACE-1 levels (p < 0.1, t-test). These findings demonstrate, for the first time, an in vitro diagnostic approach based on a portable electrochemical biosensor for early AD detection in plasma through a novel exosomal biomarker panel. Compared to conventional diagnostics, this biosensor offers a non-invasive and cost-effective solution for AD screening, with the potential to support earlier intervention and patient risk stratification.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

The activity of alkaline phosphatase in breast cancer exosomes simplifies the biosensing design

  • Lima Moura, Silio|||0000-0001-8867-6029
  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Sappia, Luciano|||0000-0001-8474-0142
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
This work addresses a biosensor combining the immunomagnetic separation and the electrochemical biosensing based on the intrinsic ALP activity of the exosomes. This approach explores for the first time two different types of biomarkers on exosomes, in a unique biosensing device combining two different biorecognition reaction: immunological and enzymatic. Besides, the intrinsic activity of alkaline phosphatase (ALP) in exosomes as a potential biomarker of carcinogenesis as well as osseous metastatic invasion is also explored. To achieve that, as an in vitro model, exosomes from human fetal osteoblasts are used. It is demonstrated that the electrochemical biosensor improves the analytical performance of the gold standard colorimetric assay for the detection of ALP activity in exosomes, providing a limit of detection of 4.39 mU L-1, equivalent to 105 exosomes μL-1. Furthermore, this approach is used to detect and quantify exosomes derived from serum samples of breast cancer patients. The electrochemical biosensor shows reliable results for the differentiation of healthy donors and breast cancer in- dividuals based on the immunomagnetic separation using specific epithelial biomarkers CD326 (EpCAM) com- bined with the intrinsic ALP activity electrochemical readout.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Electrochemical genosensing of overexpressed GAPDH transcripts in breast cancer exosomes

  • Pallarès-Rusiñol, Arnau|||0000-0001-9990-148X
  • Lima Moura, Silio|||0000-0001-8867-6029
  • Martí, Mercè|||0000-0002-1846-0043
  • Pividori, María Isabel|||0000-0002-5266-7873
Exosomes are receiving highlighted attention as new biomarkers for the detection of cancer since they are profusely released by tumor cells in different biological fluids. In this paper, the exosomes are preconcentrated from the serum by immunomagnetic separation (IMS) based on a CD326 receptor as a specific epithelial cancer-related biomarker and detected by glyceraldehyde-3-phosphate dehydrogenase (GAPDH) transcripts. Following the lysis of the captured exosomes, the released GAPDH transcripts are amplified by reverse transcription polymerase chain reaction (RT-PCR) with a double-tagging set of primers on poly(dT)-modified-MPs to increase the sensitivity. The double-tagged amplicon is then quantified by electrochemical genosensing. The IMS/double-tagging RT-PCR/electrochemical genosensing approach is first demonstrated for the sensitive detection of exosomes derived from MCF7 breast cancer cells and compared with CTCs in terms of the analytical performance, showing an LOD of 4 × 102 exosomes μL-1. The genosensor was applied to human samples by immunocapturing the exosomes directly from serum from breast cancer patients and showed a higher electrochemical signal (3.3-fold, p < 0.05), when compared with healthy controls, suggesting an overexpression of GAPDH on serum-derived exosomes from breast cancer patients. The detection of GAPDH transcripts is performed from only 1.0 mL of human serum using specific magnetic particles, improving the analytical simplification and avoiding ultracentrifugation steps, demonstrating to be a promising strategy for minimal invasive liquid biopsy.