Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Gold nanoclusters as elemental label for the sequential quantification of apolipoprotein E and metallothionein 2A in individual human cells of the retinal pigment epithelium using single cell-ICP-MS

  • Lores-Padín, Ana
  • Mavrakis, Emmanouil
  • Fernández-Vega, Beatriz
  • García, Montserrat
  • González-Iglesias, Héctor
  • Pereiro, Rosario
  • Pergantis, Spiros A.
Gold nanoclusters (AuNCs) with a diameter of 1.99 nm on average were synthesized and applied as labels in immunoprobes for the determination of cytosolic proteins in individual human retinal pigment epithelium (HRPEsv) cells by single cell – inductively coupled plasma – mass spectrometry (sc-ICP-MS). For quantitative purposes, the number of gold atoms per immunoprobe (i.e., the amplification factor) was determined; 466 gold atoms on average were obtained. Human metallothioneins (MT), including the 2A isoform (MT2A), and apolipoprotein E (APOE) play an important role under inflammation and oxidation processes in the RPE. The new single biomarker strategy introduced was applied to the sequential determination of MT2A and APOE in HRPEsv cells under pro-inflammatory and control conditions through the development of immunoassays with the corresponding AuNCs immunoprobes and the measurement of the Au signal by sc-ICP-MS. In addition, Fe signal was measured as constituent element of HRPEsv cells in order to check the integrity of the cells after the immunoassay and to confirm the number of cell events detected when monitoring the protein label (Au). Optimisation of parameters related with the sample preparation for the analysis of cytosolic proteins in intact HRPEsv cells was carried out. The method was successfully applied to the determination of both proteins in control cells and cells treated with the recombinant human interleukin-1α. Quantitative results obtained per cell for the average protein amounts of APOE and MT2A using the sc-ICP-MS procedure were corroborated with commercial ELISA kits., This work was financially supported through project PID2019- 107838RB-I00/Agencia Estatal de Investigacion (AEI)/10.13039/ 501100011033). A. Lores-Padín acknowledges the FPU Grant (Ref. MECD-17-FPU16/01363; Ministry of Education) and “Estancias Breves y Traslados Temporales FPU Grant” (Ref. EST19/00274). A. Lores-Padín would like to thank Assist. Prof. I.V. Pavlidis and his group for the biochemical facility support during her work at the University of Crete.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Iridium nanoclusters as high sensitive-tunable elemental labels for immunoassays: Determination of IgE and APOE in aqueous humor by inductively coupled plasma-mass spectrometry

  • Menero-Valdés, Paula
  • Lores-Padín, Ana
  • Fernández-Vega, Beatriz
  • González-Iglesias, Héctor
  • Pereiro, Rosario
Iridium nanoclusters (IrNCs) stabilized with citrate were synthesized and then the ligand was exchanged by lipoic acid (LA). The IrNCs@LA were bioconjugated through carbodiimide chemistry with specific antibodies to prepare IrNCs-labelled immunoprobes. The IrNCs-immunoprobes were employed in competitive immunoassays for immunoglobulin E (IgE) and apolipoprotein E (APOE) determination by detecting the iridium through inductively coupled plasma – mass spectrometry (ICP-MS). The IrNCs@LA have a 1.89 nm diameter at average and each NC contains 250 Ir atoms. Labelling of specific antibodies with IrNCs was optimized in terms of recognition capabilities and signal amplification by ICP-MS. Amplification and detection limits can be tuned by selecting the IrNCs:Ab molar ratio. An immunoprobe prepared by mixing a 10:1 IrNC:Ab molar ratio was selected for the determination of IgE and APOE in aqueous humor, achieving a signal amplification of 1760 iridium atoms per molecule of the sought protein and limits of detection in the tens of pg mL of protein. The IrNCs-immunoprobes were evaluated for IgE determination in serum samples as well as for IgE and APOE in aqueous humor (from controls subjects and patients affected by primary open angle glaucoma) by ICP-MS, being required just sample dilution as pre-treatment. Results were corroborated with commercial ELISA kits., This work was financially supported through project PID2019-107838RB-I00/Agencia Estatal de Investigación (AEI)/10.13039/501100011033) in Spain. P. Menero-Valdés and A. Lores-Padín acknowledge the FPU Grants with Ref. FPU19/00556 and FPU16/01363, respectively (Ministry of Education, Spain). Authors would like to acknowledge the technical support provided by Servicios Científico-Técnicos of the University of Oviedo.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Metal nanoclusters as elemental labels for the determination of specific proteins related to eye neurodegenerative diseases in individual cells by single cell and laser ablation ICP-MS

  • Fernández-Vega, Beatriz
  • Menero-Valdés, Paula
  • Lores-Padín, Ana
  • Quarles Jr., C. Derrick
  • García, Montserrat
  • González-Iglesias, Héctor
  • Pereiro, Rosario
Resumen del trabajo presentado en el Colloquium Spectroscopicum Internationale XLII (CSI XLII), celebrado en Gijón (España), del 30 de mayo al 3 de junio de 2022
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Real matrix-matched calibration strategy for the quantification of neurodegeneration-related proteins in single human epithelial cells by LA-ICP-MS using specific metal-labelled antibodies

  • Lores-Padín, Ana
  • García, Montserrat
  • González-Iglesias, Héctor
  • Fernández-Vega, Beatriz
  • Pereiro, Rosario
Resumen del trabajo presentado en el 15th European Workshop on Laser Ablation (EWLA 2022), celebrado en Berna (Suiza), del 12 al 15 de julio de 2022, Biological heterogeneity is a well-known fact that affects the study of biological processes, especially regarding cells. At present, there is a current need of developing new analytical methodologies allowing for the determination of elements and biomolecules in a cell-to-cell basis [1]. In this regard, laser ablation (LA) coupled to ICP-MS is a promising complementary alternative to liquid nebulization single cell (sc) ICP-MS for the characterization of individual cells. Furthermore, not only the analysis of elements naturally present in the cells can be tackled but also specific biomolecules through the combination of LA-ICP-MS with adequate metal-labelling strategies [2]. In this way, the qualitative 2D-mapping of target biomolecules with a subcellular resolution can be performed. However, the persistent lack of adequate matrix-matched reference materials still hinders the quantitative analysis of elements and biomolecules in biological samples by LA-ICP-MS, being especially critical in cell cultures due to their complex matrix. In this work, we propose a novel matrix-matched calibration strategy, which fully mimics the matrix of cultured cells, by using the same cell line of the sample to create laboratory standards. As a case of study, the sequential quantification of two cytosolic proteins (MT2A and APOE) in individual human retinal pigment epithelial (HRPEsv) cells, both in cells subjected to inflammation with cytokine Interleukin-1α and control, was carried out. For such purpose, a single biomarker strategy using well-characterized Au nanoclusters (AuNCs) as specific antibody labels was performed for the proteins tagging. The laboratory standards were created by supplementing HRPEsv cells with suspensions containing nude AuNCs (HRPEsv@AuNCs cells). The preparation and characterisation of the single-cell laboratory standards (by both ICP-MS and LA-ICPMS) were optimised as well as the data treatment protocol required for obtaining the quantitative distribution of the proteins in individual cells. To corroborate the quantitative results obtained for the proteins determination by LA-ICP-MS in HRPEsv cells, sc-ICP-MS analysis and commercial ELISA kits were employed., This work was financially supported through project PID2019-107838RB-I00 Agencia Estatal de Investigación (AEI)/10.13039/501100011033) and project AYUD/2021/51289 - FICYT. A. Lores- Padín acknowledges the FPU Grant (Ref. MECD-17-FPU16/01363; Ministry of Education).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Real matrix-matched standards for quantitative bioimaging of cytosolic proteins in individual cells using metal nanoclusters as immunoprobes-label: A case study using laser ablation ICP-MS detection

  • Lores-Padín, Ana
  • Fernández, Beatriz
  • García, Montserrat
  • González-Iglesias, Héctor
  • Pereiro, Rosario
The persistent lack of adequate matrix-matched reference materials still hinders the quantitative analysis of elements and biomolecules in biological samples by LA-ICP-MS. This fact is especially critical in cell cultures due to their complex matrix. In this work, we propose a novel matrix-matched calibration strategy, which fully mimics the matrix of cultured cells, by using the same cell line of the sample to create laboratory standards. As a model case, the quantitative imaging of two cytosolic proteins (MT2A and APOE) in individual HRPEsv cells was performed by LA-ICP-MS, both in cells subjected to inflammation with cytokine Interleukin-1α (IL-1α) and controls (CT). A single biomarker strategy using Au nanoclusters (AuNCs) as specific antibody labels was employed for the analysis of the selected proteins in individual cells by LA-ICP-MS. HRPEsv cells supplemented with suspensions containing nude AuNCs was employed to generate single-cell laboratory standards (HRPEsv cells@AuNCs). The preparation and characterization of the single-cell laboratory standards by both ICP-MS and LA-ICP-MS were optimized as well as the data treatment protocol required for obtaining the quantitative distribution of the proteins in individual cells. The mass of APOE and MT2A per cell in CT and IL1α−treated HRPEsv cells analysed by LA-ICP-MS using the proposed matrix-matched calibration were successfully corroborated with commercial ELISA kits. In addition, quantitative real time polymerase chain reaction (qPCR) analyses were performed to study the proteins gene expression., This work was financially supported through project PID2019-107838RB-I00/Agencia Estatal de Investigación (AEI)/10.13039/501100011033). A. Lores-Padín acknowledges the FPU Grant (Ref. MECD-17-FPU16/01363; Ministry of Education). Authors would like to acknowledge the technical support provided by Servicios Científico-Técnicos of the University of Oviedo.