Publication Artículo científico (JournalArticle)

A Flexible PDMS-Based Optical Biosensor for Stretch Monitoring in Cardiac Tissue Samples

  • Sannino, Andrea
  • Velarte, Antonio
  • Otín, Aránzazu
  • Artigas, José Ignacio
  • Oliván-Viguera, Aida
Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane—where the samples are attached—which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10–30% stretches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Optical fiber integration in PDMS devices for dynamic tissue deformation

  • Velarte, Antonio
  • Sannino, Andrea
  • Otin, Aranzazu
  • Santamaría, Beatriz
  • Artigas, José Ignacio
  • Pueyo, Esther
This study introduces an advanced optical fiber-based stretchable sensing platform designed for precise biomechanical characterization in tissue engineering applications, specifically tailored for cardiac tissue studies. The system is entirely fabricated from biocompatible polydimethylsiloxane (PDMS) material, and features a thin upper membrane and an internal cavity where controlled pneumatic deformation occurs. Deformation is quantified through changes in optical intensity measured through a strategically aligned optical fiber pair, as membrane stretching disrupts total internal reflection conditions. Finite element modeling using COMSOL is used to optimize device geometry and predict deformation, which is subsequently validated through experimental analyses. A custom-designed electronic system with capacity for real-time signal processing ensures stable and sensitive data acquisition. The experimental results show high levels of linearity and repeatability in a physiologically relevant stretch range, highlighting its potential for biomechanical research applications and dynamic tissue stimulation. Future improvements are directed toward extending the reliable deformation operating range through advances in the optical system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Fabrication and integration of partially-transparent ionic polymer–metal composite actuators into microphysiological systems

  • Tajeddin, Alireza
  • Velarte, Antonio
  • Sattari, Romina
  • Wiendels, Maury
  • Hunt, Andres
  • Mummery, Christine L.
  • Orlova, Valeria
  • Zhang, Juan
  • Portero, Vincent
  • Pueyo, Esther
  • Otín, Arantxa
  • Mastrangeli, Massimo
We present partially-transparent ionic polymer–metal composite (IPMC) actuators and their seamless integration into microphysiological systems, to enable dynamic mechanical stimulation of cell monolayers with direct optical access. The proposed IPMC platform employs a layered microfabrication strategy that allows precise tailoring of electrode geometry while preserving optical transparency across selected regions of the actuator. This design overcomes a key limitation of conventional IPMCs, namely their inherent opacity and resulting lack of (bio-)opto-mechatronics compatibility, thereby facilitating in vitro applications and real-time optical and fluorescent microscopy. The actuators are integrated into standard 12-well culture plates through customized mechanical and electrical interfaces and are driven by a compact, programmable electronic control system, enabling flexible modulation of actuation dynamics within biologically-relevant regimes. We confirm the biocompatibility of the platform by culturing Human Embryonic Kidney (HEK) cells and contractile cardiomyocytes from human-induced pluripotent stem cells (hiPSC-CMs). Together, these advances establish a scalable, low-voltage, and optically-compatible actuation platform for organ-on-chip and mechanobiology applications.