RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A complete software application for automatic registration of x-ray mammography and magnetic resonance images

  • Solves Llorens, Juan Antonio
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • Monserrat, C.
  • Feliu, E
  • Garcia, M
  • Lloret, M
Purpose: This work presents a complete and automatic software application to aid radiologists in breast cancer diagnosis. The application is a fully automated method that performs a complete registration of magnetic resonance (MR) images and x-ray (XR) images in both directions (from MR to XR and from XR to MR) and for both x-ray mammograms, craniocaudal (CC), and mediolateral oblique (MLO). This new approximation allows radiologists to mark points in the MR images and, without any manual intervention, it provides their corresponding points in both types of XR mammograms and vice versa. Methods: The application automatically segments magnetic resonance images and x-ray images using the C-Means method and the Otsu method, respectively. It compresses the magnetic resonance images in both directions, CC and MLO, using a biomechanical model of the breast that distinguishes the specific biomechanical behavior of each one of its three tissues (skin, fat, and glandular tissue) separately. It makes a projection of both compressions and registers them with the original XR images using affine transformations and nonrigid registration methods. Results: The application has been validated by two expert radiologists. This was carried out through a quantitative validation on 14 data sets in which the Euclidean distance between points marked by the radiologists and the corresponding points obtained by the application were measured. The results showed a mean error of 4.2 ± 1.9 mm for the MRI to CC registration, 4.8 ± 1.3 mm for the MRI to MLO registration, and 4.1 ± 1.3 mm for the CC and MLO to MRI registration. Conclusions: A complete software application that automatically registers XR and MR images of the breast has been implemented. The application permits radiologists to estimate the position of a lesion that is suspected of being a tumor in an imaging modality based on its position in another different modality with a clinically acceptable error. The results show that the application can accelerate the mammographic screening process for high risk populations or for dense breasts., This project has been partially funded by the Regional Valencian Government (reference ACOMP/2012/181), by CDTI (reference IDI-20101153), and by MICINN (reference TIN2010-20999-C04-01). The authors would like to express our gratitude to the personnel from the HCB and La Fe Hospitals.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Method for Liver Segmentation on Computed Tomography Images in Venous Phase Suitable for Real Environments

  • López-Mir, Fernando|||0000-0001-8286-6796
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • González Pérez, Pablo
  • Pareja, Eugenia
  • Morales, Sandra
  • Solaz-Minguez, Jaime
Nowadays, different methods are being published for the segmentation of the liver but, in general, most of them are not suitable for clinical practice due to several inconveniences as high computational cost, excessive user dependence or low accuracy. The purpose of this paper is to present the performance and validation of a liver segmentation method in computed tomography images (contrast venous phase) where automation, easy user interaction, and low computational cost (besides the required accuracy for clinical purposes) have been taken into account. Firstly, an adaptive filter based on intrinsic parameters of the liver is applied to reduce noise but preserving external liver gradients. In a second step, from a seed or a group of them, voxels with similar intensities are included in an initial 3D mask. Finally, thanks to the combination of morphological operators in different orientations, several non-liver structures (cava vein, ribs, stomach or heart) are removed and the final 3D liver mask is obtained. Thirty public datasets have been used to estimate the accuracy of the proposed algorithm, twenty for training the method and ten for testing it. An average Jaccard index of 0.91 (±0.03), a Hausdorff distance of 26.68 (±10.42) mm, and a runtime of 0.25 seconds per slice, state a promising efficiency and efficacy in the test datasets. To our knowledge, liver segmentation methods in the state of the art are achieving high accuracy at the expense of requiring an exhaustive training stage and so much clinician interaction time in different steps of the process. In this paper, a method based on intensity properties is carried out with a high grade of automatism, an easy user interaction and a low computational cost. The results obtained for different patients state a low variance and a good accuracy in most images, thus the robustness of the method is demonstrated., Thanks to the Hospital Clinica Benidorm (HCB) for funding this project. This work has been supported by the Centro para el Desarrollo Tecnologico Industrial (CDTI) under the project ONCOTIC (IDI-20101153), partially by the Ministry of Education and Science Spain (TIN2010-20999-004-01).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of several biomechanical models for the simulation of lamb liver behaivour using similarity coefficients from medical image

  • Martínez Martínez, Francisco
  • Lago Ángel, Miguel Ángel
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • C. Monserrat|||0000-0003-1790-8085
In this study, six biomechanical models for simulating lamb liver behaviour are presented. They are validated using similarity coefficients from Medical Image on reconstructed volumes from computerised tomography images. In particular, the Jaccard and Hausdorff coefficients are used. Loads of 20 and 40 g are applied to the livers and their deformation is simulated by means of the finite element method. The models used are a linear elastic model, a neo-Hookean model, a Mooney¿Rivlin model, an Ogden model, a linear viscoelastic model and a viscohyperelastic model. The model that provided a behaviour that is closest to reality was the viscohyperelastic model, where the hyperelastic part was modelled with an Ogden model., This project has been partially funded by MITYC (reference TSI-020100-2009-189), by CDTI (reference IDI-20101153) and by MICINN (reference TIN2010-20999-C04-01). We would like to express our gratitude to the personnel from the HCB hospital where the experiments with the CT Machine were carried out.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Liver segmentation in MRI: a fully automatic method based on stochastic partitions

  • López-Mir, Fernando|||0000-0001-8286-6796
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Angulo, J.
  • Luna, L.
There are few fully automated methods for liver segmentation in magnetic resonance images (MRI) despite the benefits of this type of acquisition in comparison to other radiology techniques such as computed tomography (CT). Motivated by medical requirements, liver segmentation in MRI has been carried out. For this purpose, we present a new method for liver segmentation based on the watershed transform and stochastic partitions. The classical watershed over-segmentation is reduced using a marker-controlled algorithm. To improve accuracy of selected contours, the gradient of the original image is successfully enhanced by applying a new variant of stochastic watershed. Moreover, a final classifier is performed in order to obtain the final liver mask. Optimal parameters of the method are tuned using a training dataset and then they are applied to the rest of studies (17 datasets). The obtained results (a Jaccard coefficient of 0.91 +/- 0.02) in comparison to other methods demonstrate that the new variant of stochastic watershed is a robust tool for automatic segmentation of the liver in MRI. (C) 2014 Elsevier Ireland Ltd. All rights reserved., This work has been supported by the MITYC under the project NaRALap (ref. TSI-020100-2009-189), partially by the CDTI under the project ONCOTIC (IDI-20101153), by Ministerio de Educacion y Ciencia Spain, Project Game Teen (TIN2010-20187) projects Consolider-C (SEJ2006-14301/PSIC), "CIBER of Physiopathology of Obesity and Nutrition, an initiative of ISCIII" and Excellence Research Program PROMETEO (Generalitat Valenciana. Conselleria de Educacion, 2008-157). We would like to express our gratitude to the Hospital Clinica Benidorm, for providing the MR datasets and to the radiologist team of Inscanner for the manual segmentation of the MR images.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Segmentation of the breast skin and its influence in the simulation of the breast compresion during an X-Ray mammography

  • Solves Llorens, Juan Antonio
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • C. Monserrat|||0000-0003-1790-8085
  • Feliu, E.
  • García, M.
  • Lloret, M.
A novel method of skin segmentation is presented aimed to obtain as many pixels belonging to the real skin as possible. This method is validated by experts in radiology. In addition, a biomechanical model of the breast, which considers the skin segmented in this way, is constructed to study the influence of considering real skin in the simulation of the breast compression during an X-ray mammography. The reaction forces of the plates are obtained and compared with the reaction forces obtained using classical methods that model the skin as a 2D membranes that cover all the breast. The results of this work show that, in most of the cases, the method of skin segmentation is accurate and that real skin should be considered in the simulation of the breast compression during the X-ray mammographies. Copyright © 2012 J. A. Solves Llorens et al., This project has been partially funded by the Regional Valencian Government through IMPIVA with FEDER funding (reference IMIDTF/2010/111), by CDTI (reference IDI-20101153), and by MICINN (reference TIN2010-20999-C04-01). The authors would like to express their gratitude to the personnel from the Hospitals HCB and La Fe.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Parameter optimization of the liver tissue mechanical properties by means of FE modeling of the respiratory liver motion and similarity coefficients

  • Martínez Martínez, Francisco
  • Martín-Guerrero, J.
  • Pareja, E.
  • López-Andújar, R.
  • Brugger, S.
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • C. Monserrat|||0000-0003-1790-8085
This work has been partially supported by CDTI (ref. IDI-20101153) and by MICINN (ref. TIN2010-20999-C04-01) and by GVA (ref. ACOMP/2012/181). The work of Francisco Martı´nez-Martı´nez has been supported by the Spanish Government under the FPI Grant BES2011-046495. We would also like to express our deep gratitude to the Hospital Clı´nica Benidorm for its participation in this project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

  • López-Mir, Fernando|||0000-0001-8286-6796
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Fuertes Cebrián, Juan José
  • Bueno, J.
  • Pareja, E.
Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments.The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery., This work has been supported by Centro para el Desarrollo Tecnologico Industrial (CDTI) under the project Oncotic (IDI-20101153) and the Hospital Clinica Benidorm(HCB) and partially supported by the Ministry of Education and Science of Spain (TIN2010-20999-C04-01), the project Consolider-C (SEJ2006-14301/PSIC) and the "CIBER of Physiopathology of Obesity Nutrition, an initiative of ISCIII" Prometheus and Excellence Research Program (Generalitat Valenciana, Department of Education, 2008-157). The authors would like to express their gratitude to the Hospital Clinica Benidorm and to the Hospital Univeritari i Politecnic la Fe (especially the surgical team) for their participation and involvement in this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Estimation of the elastic parameters of human liver biomechanical models by means of medical images and evolutionary computation

  • Martínez Martínez, Francisco
  • Martín Guerrero, José David
  • Lago, M. A.
  • Pareja, E.
  • Brugger, S.
  • López-Andújar, R.
  • Rupérez Moreno, María José|||0000-0001-8457-7963
  • C. Monserrat|||0000-0003-1790-8085
This paper presents a method to computationally estimate the elastic parameters of two biomechanical models proposed for the human liver. The method is aimed at avoiding the invasive measurement of its mechanical response. The chosen models are a second order Mooney–Rivlin model and an Ogden model. A novel error function, the geometric similarity function (GSF), is formulated using similarity coefficients widely applied in the field of medical imaging (Jaccard coefficient and Hausdorff coefficient). This function is used to compare two 3D images. One of them corresponds to a reference deformation carried out over a finite element (FE) mesh of a human liver from a computer tomography image, whilst the other one corresponds to the FE simulation of that deformation in which variations in the values of the model parameters are introduced. Several search strategies, based on GSF as cost function, are developed to accurately find the elastics parameters of the models, namely: two evolutionary algorithms (scatter search and genetic algorithm) and an iterative local optimization. The results show that GSF is a very appropriate function to estimate the elastic parameters of the biomechanical models since the mean of the relative mean absolute errors committed by the three algorithms is lower than 4%. © 2013 Elsevier Ireland Ltd. All rights reserved., This project has been partially funded by CDTI (reference IDI-20101153) and by MICINN (reference TIN2010-20999-C04-01). The work of Francisco Martinez-Martinez has been supported by the Spanish Government under the FPI Grant BES-2011-046495. We would also like to express our gratitude to the Hospital Clinica Benidorm.