Assessing the energetic and environmental impacts of the operation and maintenance of Spanish sewer networks from a life-cycle perspective

  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Chenel, Sergio
  • Marín, Desirée
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Farreny Gaya, Ramon
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
The environmental impacts resulting from sewer networks are best analysed from a life-cycle perspective to integrate the energy requirements into the infrastructure design. The energy requirements for pumping wastewater depend on the configuration of the city (e.g., climate, population, length of the sewer, topography, etc.). This study analyses and models the effect of such site-specific features on energy consumption and related effects in a sample of Spanish cities. The results show that the average annual energy used by sewers (6.4 kWh/capita and 0.014 kWh/m³ of water flow) must not be underestimated because they may require up to 50 % of the electricity needs of a typical treatment plant in terms of consumption per capita. In terms of Global Warming Potential, pumping results in an average of 2.3 kg CO₂eq./capita. A significant positive relationship was demonstrated between the kWh consumed and the length of the sewer and between other factors such as the population and wastewater production. In addition, Atlantic cities can consume 5 times as much energy as Mediterranean or Subtropical regions. A similar trend was shown in coastal cities. Finally, a simple predictive model of the electricity consumption was presented that considers the analysed parameters.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Environmental assessment of drinking water transport and distribution network use phase for small to medium-sized municipalities in Spain

  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Farreny Gaya, Ramon
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
Previous studies assessing the environmental impacts of drinking water supply networks have considered a bottom-up approach, analysing single case studies. This paper presents a top-down approach for the assessment of the operational phase of a water supply network. A representative sample of 50 cities was statistically analysed to find relations between different variables regarding electricity and water consumption linked with the environmental impacts of the network. The results show that some of the variables are clearly related to the relative energy consumption of the network. Such is the case for population size, where small municipalities have up to 14 times higher relative electricity consumption compared with medium-sized municipalities (1.15E-2 as opposed to 8.3E-4 kWh/m³ registered water km of network) due to case-specific factors such as a strong gradient between a water tank and the consumption point. Similarly, the cases showing low population density exhibit 7 times higher relative electricity consumption because of the longer distances that must be covered and the correlation between population density and size. The values found for greenhouse gas (GHG) emissions derived from the energy consumption are consistent with results from previous studies: on average, 5.53 kg of CO₂ eq. emissions/inhabitant·year are released, but the variability is very high, ranging from 0.005 to 67.8 kg of CO₂ eq. emissions/inhabitant·year. No clearly significant correlations were found between the relative water demand and variables such as seasonality or income per capita, which might indicate that water consumption depends on individual decisions of the population rather than on the variables assessed. Models for the estimation of water demand, length of network and electricity consumption were defined. However, the modelling of electricity consumption presented more difficulties because of its high variability. A protocol for data collection should be defined and implemented in the future to enable the analysis of more high quality case studies and for the definition of more accurate and reliable models.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Environmental assessment of different pipelines for drinking water transport and distribution network in small to medium cities: a case from Betanzos, Spain, Environmental assessment of a drinking water transport and distribution network in small to medium cities and application to a case study network

  • Sanjuan Delmas, David|||0000-0002-5238-2069
  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Martínez Gasol, Carles|||0000-0003-3002-9229
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Josa Garcia-Tornel, Alejandro|||0000-0003-1180-7910
  • Rieradevall, Joan|||0000-0003-3360-6829
Until now, few studies had focused on the environmental impact of the construction phase of a drinking water transport and distribution network (DWTDN). Using the life cycle assessment (LCA) methodology, this article compares the environmental impact of pipes made of different materials as constructive solutions for the DWTDN. Two pipe diameters (90 and 200 mm) commonly used in small to medium-sized cities are analysed. The results show that polyvinyl chloride (PVC), high density polyethylene (HDPE) and low density PE have similar environmental impacts in the case of 90 mm pipe diameter. In the case of 200 mm pipe diameter, ductile iron (DI) and glass fibre reinforced polyester show higher environmental impacts than HDPE and PVC, which in the case of DI are between 3 and 11 times higher than those of HDPE for all the midpoint impact categories. Regarding the different construction phases, installation has a higher percentage of environmental impact for 90 mm pipe diameter (40-68% for HDPE in all the impact categories) than for 200 mm pipe diameter (24-57% for an HDPE) due to the difference in the amount of material required for the manufacture of the pipe. The assessment methodology was applied to calculate the environmental burdens derived from a case study. The impact of the different elements of the case study network has been added to obtain the global impact. The potential reduction of the environmental impacts of the case study has been calculated substituting the whole actual network by less impacting constructive solutions. A potential reduction of between 6 and 16% of the impact has been found for the case study, although the savings might be greater in networks with greater abundance of more impacting pipe materials such as DI. This methodology allows the improvement of the network and the design of more eco-efficient DWTDN.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Municipal sewer networks as sources of nitrous oxide, methane and hydrogen sulphide emissions, a review and case studies

  • Eijo Rio, Elena
  • Petit-Boix, Anna|||0000-0003-2048-2708
  • Villalba, Gara|||0000-0001-6392-0902
  • Suárez Ojeda, María Eugenia|||0000-0003-2520-2701
  • Rieradevall, Joan|||0000-0003-3360-6829
  • Gabarrell Durany, Xavier|||0000-0003-1730-4337
  • Marín, Desirée
  • Amores, Maria José
  • Aldea, Xavier
Sewers are known as longitudinal reactors where gases such as methane, nitrous oxide and hydrogen sulphide can be produced. However, gaseous emissions have been mainly assessed in wastewater treatment plants (WWTP). This article presents a critical review of studies that quantify the generation of these gases in sewers and aims to identify the existing research gaps. Differences in sampling methods and site selection, as well as a limited number of studies, result in incoherent comparisons. To address some of these gaps, sampling campaigns were conducted in two Spanish cities. Results showed that wet wells were the most important sources of gases with concentrations up to 321 μg CH4 Lair-1 and 6.8 μg N2O Lair-1. Regarding emission factors, in the case of Calafell, the estimated annual emissions were 18.6 kg CH4 year-1 and 0.3 kg H2S year-1 in summer and 3.8 kg CH4 year-1 and 0.5 kg H2S year-1 in winter. About Betanzos, these values were 24.6 kg CH4 year-1 and 0.5 kg N2O year-1 in summer and 10 kg CH4 year-1 in winter. The summer campaign resulted in greater gas concentration than in the winter season for both cities, suggesting that temperature is a key parameter. We conclude that gas emissions from sewers are significant compared to those of WWTPs resulting in an important contribution to the carbon footprint. Further work needs to be done to assess the gas production along the entire sewer networks, which can result in very different emission factors depending on the sewer components.