Skip to main content

ELECTRONICA DE OXIDOS A LA NANOESCALA: INGENIERIA DE INTERFASES EN HETEROESTRUCTURAS PARA DISPOSITIVOS MAGNETOELECTRONICOS

MAT2008-06517-C02-01

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2008
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

On the discrimination between magnetite and maghemite by XANES measurements in fluorescence mode

  • Espinosa, Ana
  • Serrano Rubio, Aída
  • Llavona, A.
  • Jiménez de la Morena, J.
  • Abuin, M.
  • Figuerola, A.
  • Pellegrino, T.
  • Fernández Lozano, José Francisco
  • García-Hernández, Mar
  • Castro, Germán R.
  • García García-Tuñón, Miguel Ángel
We discuss here the quantification of magnetite and maghemite from x-ray absorption near edge spectroscopy at the Fe K-edge in fluorescence mode. We show that the modification of the spectral shape due to self-absorption effects can lead to erroneous results for certain thicknesses. However, for homogeneous samples containing just magnetite and maghemite without other phases, the quantification of magnetite and maghemite can be obtained from the spectra measured in fluorescence mode without correcting the spectra for the self-absorption effects. We describe the conditions to carry on this analysis that requires measuring the reference compounds exactly under the same conditions as the studied samples and using the appropriate thickness. © 2012 IOP Publishing Ltd., Authors acknowledge European Synchrotron Radiation Facility for provision of synchrotron radiation facilities and thank the SpLine CRG beamline (BM25) staff for assistance during X-ray absorption experiments. C. Prieto is acknowledged for critical reading of the manuscript and valuable comments. This work has been supported by the European project MAGNIFYCO (Contract NMP4-SL-2009-228622), by Spanish Ministry of Science and innovation through the projects FIS-2008-06249, MAT2010-C21088-C03, MAT2008-06517-C02-01 and Comunidad de Madrid, project NANOBIOMAGNET (S2009/MAT-1726)., Peer reviewed