Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Antibacterial coatings on titanium surfaces: a comparison study between in vitro single-species and multispecies biofilm

  • Godoy-Gallardo, Maria
  • Wang, Zhejun
  • Shen, Ya
  • Manero, José María
  • Gil, FJ
  • Rodríguez Rius, Daniel
  • Haapasale, Markus
This study was supported by the Ministry of Economy and Competitiveness (MINECO) of the Spanish Government (Projects: MAT2009-12547, MAT2012-30706), Fundación Ramón Areces and co-funded by the European Union through European Regional Development Funds. Research reported in this study was also with the support of the Canada Foundation for Innovation (CFI fund; Project No. 32623), and the National Natural Science Foundation of China (NSFC; Grant No. 81300904)., Dental plaque is a biofilm that causes dental caries, gingivitis, and periodontitis. Most of the studies in antibacterial coatings have been conducted by in vitro single-species biofilm formation, but oral biofilm involves more than 700 different bacterial species that are able to interact. Therefore, new studies are focused on in vitro multispecies biofilm models that mimic in vivo biofilms. The aim of the present work was to study different antibacterial coatings onto titanium surfaces and evaluate the in vitro antimicrobial properties of the surfaces on two different bacterial species and an oral biofilm. The lactate dehydrogenase assay determined that treated samples did not affect fibroblast viability. In addition, the viability of microorganisms on modified samples was evaluated by a LIVE/DEAD BacLight bacterial viability kit. Although a decrease in viable bacteria onto treated samples was obtained, the results showed differences in effectiveness when single-biofilm and oral plaque were tested. It confirms, as we expected, the distinct sensitivities that bacterial strains have. Thus, this multispecies biofilms model holds a great potential to assess antibacterial properties onto samples for dental purposes., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Development of tantalum scaffold for orthopaedic applications produced by space-holder method

  • Rupérez de Gracia, Elisa
  • Manero Planella, José María
  • Riccardi Hernandez, Kiara
  • Li, Yuping
  • Aparicio Bádenas, Conrado José
  • Gil Mur, Francisco Javier
This study was supported by the Ministery of Science and Innovation (MICINN) and the Ministery of Economy and Competitiveness (MINECO) of the Spanish Government (Projects MAT2009-12547)., In the present study, production of tantalum porous scaffolds using the space holder technique was performed. The effect of size and content of sodium chloride particles, used as space holder, as well as compacting pressure on foam structure and mechanical properties have been investigated. The morphological characterization was carried out by means of scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP) and micro-CT technique. The relationship between the elastic modulus and yield strength of the tantalum porous scaffold and the pore structure was evaluated. Space holder technique allows obtaining tantalum open-cell structure (70% of porosity) and modulus of elasticity similar to cancellous bone, with reproducible processability into three-dimensional structures and reasonable manufacturing costs., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Antibacterial properties of hLf1-11 peptide onto titanium surfaces: a comparison study between silanization and surface initiated polymerization

  • Godoy-Gallardo, Maria
  • Mas-Moruno, Carlos
  • Yu, Kai
  • Manero, José María
  • Gil, FJ
  • Kizhakkedathu, Jayachandran
  • Rodríguez Rius, Daniel
This study was supported by the Ministry of Science and Innovation (MICINN) and the Ministry of Economy and Competitiveness (MINECO) of the Spanish Government (Projects: MAT2009-12547, MAT2012-30706 co-funded by the European Union through European Regional Development Funds). C.M.-M. thanks the support of the Secretary for Universities and Research of the Ministry of Economy and Knowledge of the Government of Catalonia (2011-BP-B-00042) and the People Programme (Marie Curie Actions) of the European Union's Seventh Framework Programme (FP7-PEOPLE-2012-CIG, REA grant agreement n° 321985)., Dental implant failure can be associated with infections that develop into peri-implantitis. In order to reduce biofilm formation, several strategies focusing on the use of antimicrobial peptides (AMPs) have been studied. To covalently immobilize these molecules onto metallic substrates, several techniques have been developed, including silanization and polymer brush prepared by surface-initiated atom transfer radical polymerization (ATRP), with varied peptide binding yield and antibacterial performance. The aim of the present study was to compare the efficiency of these methods to immobilize the lactoferrin-derived hLf1–11 antibacterial peptide onto titanium, and evaluate their antibacterial activity in vitro. Smooth titanium samples were coated with hLf1–11 peptide under three different conditions: silanization with 3-aminopropyltriethoxysilane (APTES), and polymer brush based coatings with two different silanes. Peptide presence was determined by X-ray photoelectron spectroscopy, and the mechanical stability of the coatings was studied under ultrasonication. The LDH assays confirmed that HFFs viability and proliferation were no affected by the treatments. The in vitro antibacterial properties of the modified surfaces were tested with two oral strains (Streptococcus sanguinis and Lactobacillus salivarius) showing an outstanding reduction. A higher decrease in bacterial attachment was noticed when samples were modified by ATRP methods compared to silanization. This effect is likely due to the capacity to immobilize more peptide on the surfaces using polymer brushes and the nonfouling nature of polymer PDMA segment., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs

  • Godoy Gallardo, María
  • Manzanares, Maria Cristina
  • Sevilla Sánchez, Pablo
  • Nart, José
  • Manzanares, Norberto
  • Manero Planella, José María
  • Gil Mur, Francisco Javier
  • Boyd, Steven K.
  • Rodríguez Rius, Daniel
The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10 units), Ti_Ag (silver electrodeposition treatment, 10 units), and Ti_TSP (silanization treatment, 10 units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2 months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were p¬erformed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P < 0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs

  • Godoy Gallardo, Maria
  • Manzanares-Céspedes, Maria Cristina
  • Sevilla Sánchez, Pablo
  • Nart Molina, José
  • Manzanares, Norberto
  • Manero Planella, José María
  • Gil Mur, Francisco Javier
  • Boyd, Steven K.
  • Rodríguez, Daniel
The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10 units), Ti_Ag (silver electrodeposition treatment, 10 units), and Ti_TSP (silanization treatment, 10 units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2 months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P < 0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Silver deposition on titanium surface by electrochemical anodizing process reduces bacterial adhesion of Streptococcus sanguinis and Lactobacillus salivarius

  • Godoy Gallardo, Maria
  • Rodríguez‐Hernández, Ana G.
  • Delgado, Luis M.
  • Manero Planella, José María
  • Gil Mur, Francisco Javier
  • Rodríguez, Daniel
This investigation was supported by the Research Grant MAT2009-12547 from the Ministry of Science and Innovation (MICINN). The authors also express their gratitude to Dr. Virginia Paredes, for her useful comments and advices regarding the XPS analysis., Objectives: The aim of this study was to determine the antibacterial properties of silver‐doped titanium surfaces prepared with a novel electrochemical anodizing process. Material and methods: Titanium samples were anodized with a pulsed process in a solution of silver nitrate and sodium thiosulphate at room temperature with stirring. Samples were processed with different electrolyte concentrations and treatment cycles to improve silver deposition. Physicochemical properties were determined by X‐ray photoelectron spectroscopy, contact angle measurements, white‐light interferometry, and scanning electron microscopy. Cellular cytotoxicity in human fibroblasts was studied with lactate dehydrogenase assays. The in vitro effect of treated surfaces on two oral bacteria strains (Streptococcus sanguinis and Lactobacillus salivarius) was studied with viable bacterial adhesion measurements and growth curve assays. Nonparametric statistical Kruskal–Wallis and Mann–Whitney U‐tests were used for multiple and paired comparisons, respectively. Post hoc Spearman's correlation tests were calculated to check the dependence between bacteria adhesion and surface properties. Results: X‐ray photoelectron spectroscopy results confirmed the presence of silver on treated samples and showed that treatments with higher silver nitrate concentration and more cycles increased the silver deposition on titanium surface. No negative effects in fibroblast cell viability were detected and a significant reduction on bacterial adhesion in vitro was achieved in silver‐treated samples compared with control titanium. Conclusions:Silver deposition on titanium with a novel electrochemical anodizing process produced surfaces with significant antibacterial properties in vitro without negative effects on cell viability., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Anhydride-functional silane immobilized onto titanium surfaces induces osteoblast cell differentiation and reduces bacterial adhesion and biofilm formation

  • Godoy-Gallardo, Maria
  • Guillem-Marti, Jordi
  • Sevilla Sánchez, Pablo
  • Manero, José María
  • Gil, FJ
  • Rodríguez Rius, Daniel
This work was supported by Fundación Ramón Areces and the Spanish Government (MINECO) under Grants MAT2009-12547 and MAT2012-30706, both co-funded by the European Union through European Regional Development Funds. M. Godoy-Gallardo and F.J. Gil report that they have a patent (ES patent P201 331756) on the TESPSA silane application., Bacterial infection in dental implants along with osseointegration failure usually leads to loss of the device. Bioactive molecules with antibacterial properties can be attached to titanium surfaces with anchoring molecules such as silanes, preventing biofilm formation and improving osseointegration. Properties of silanes as molecular binders have been thoroughly studied, but research on the biological effects of these coatings is scarce. The aim of the present study was to determine the in vitro cell response and antibacterial effects of triethoxysilypropyl succinic anhydride (TESPSA) silane anchored on titanium surfaces. X-ray photoelectron spectroscopy confirmed a successful silanization. The silanized surfaces showed no cytotoxic effects. Gene expression analyses of Sarcoma Osteogenic (SaOS-2) osteoblast-like cells cultured on TESPSA silanized surfaces reported a remarkable increase of biochemical markers related to induction of osteoblastic cell differentiation. A manifest decrease of bacterial adhesion and biofilm formation at early stages was observed on treated substrates, while favoring cell adhesion and spreading in bacteria–cell co-cultures. Surfaces treated with TESPSA could enhance a biological sealing on implant surfaces against bacteria colonization of underlying tissues. Furthermore, it can be an effective anchoring platform of biomolecules on titanium surfaces with improved osteoblastic differentiation and antibacterial properties., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs

  • Godoy-Gallardo, Maria
  • Manzanares Céspedes, Maria Cristina
  • Sevilla Sánchez, Pablo
  • Nart, Jose
  • Manzanares, Norberto
  • Manero, José María
  • Gil, FJ
  • Boyd, Steven
  • Rodríguez Rius, Daniel
This work was supported by Research Grants MAT2009-12547 and MAT2012-30706 (MINECO/FEDER, UE), by Fundación Ramon Areces (XVI Concurso Nacional de Ayudas a la Investigación) and Generalitat of Catalonia (BE-DGR-2012)., The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10 units), Ti_Ag (silver electrodeposition treatment, 10 units), and Ti_TSP (silanization treatment, 10 units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2 months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P < 0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-mplantitis., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Silver deposition on titanium surface by electrochemical anodizing process reduces bacterial adhesion of Streptococcus sanguinis and Lactobacillus salivarius

  • Godoy-Gallardo, Maria
  • Rodríguez Hernández, Ana Guadalupe
  • Delgado, Luis M.
  • Manero, José María
  • Gil, FJ
  • Rodríguez Rius, Daniel
This investigation was supported by the Research Grant MAT2009-12547 from the Ministry of Science and Innovation (MICINN). The authors also express their gratitude to Dr. Virginia Paredes, for her useful comments and advices regarding the XPS analysis., Objectives: The aim of this study was to determine the antibacterial properties of silver-doped titanium surfaces prepared with a novel electrochemical anodizing process. Material and methods: Titanium samples were anodized with a pulsed process in a solution of silver nitrate and sodium thiosulphate at room temperature with stirring. Samples were processed with different electrolyte concentrations and treatment cycles to improve silver deposition. Physicochemical properties were determined by X-ray photoelectron spectroscopy, contact angle measurements, white-light interferometry, and scanning electron microscopy. Cellular cytotoxicity in human fibroblasts was studied with lactate dehydrogenase assays. The in vitro effect of treated surfaces on two oral bacteria strains (Streptococcus sanguinis and Lactobacillus salivarius) was studied with viable bacterial adhesion measurements and growth curve assays. Nonparametric statistical Kruskal-Wallis and Mann-Whitney U-tests were used for multiple and paired comparisons, respectively. Post hoc Spearman's correlation tests were calculated to check the dependence between bacteria adhesion and surface properties. Results: X-ray photoelectron spectroscopy results confirmed the presence of silver on treated samples and showed that treatments with higher silver nitrate concentration and more cycles increased the silver deposition on titanium surface. No negative effects in fibroblast cell viability were detected and a significant reduction on bacterial adhesion in vitro was achieved in silver-treated samples compared with control titanium. Conclusions: Silver deposition on titanium with a novel electrochemical anodizing process produced surfaces with significant antibacterial properties in vitro without negative effects on cell viability., info:eu-repo/semantics/acceptedVersion