Skip to main content

SUPERFICIES MULTIFUNCIONALES BIOMIMETICAS: UNA NUEVA ESTRATEGIA BIOMOLECULAR PARA CONTROLAR LA RESPUESTA CELULAR EN TERAPIAS REGENERATIVAS

MAT2017-83905-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A dual molecular biointerface combining RGD and KRSR sequences improves osteoblastic functions by synergizing integrin and cell-membrane proteoglycan binding

  • Hoyos Nogués, Mireia|||0000-0003-4221-5643
  • Falgueras Batlle, Elena
  • Ginebra Molins, Maria Pau|||0000-0002-4700-5621
  • Manero Planella, José María|||0000-0002-1673-4389
  • Gil Mur, Francisco Javier|||0000-0002-6824-1412
  • Mas Moruno, Carlos|||0000-0001-8337-0872
Synergizing integrin and cell-membrane heparan sulfate proteoglycan signaling on biomaterials through peptidic sequences is known to have beneficial effects in the attachment and behavior of osteoblasts; however, controlling the exact amount and ratio of peptides tethered on a surface is challenging. Here, we present a dual molecular-based biointerface combining integrin (RGD) and heparin (KRSR)-binding peptides in a chemically controlled fashion. To this end, a tailor-made synthetic platform (PLATF) was designed and synthesized by solid-phase methodologies. The PLATF and the control linear peptides (RGD or KRSR) were covalently bound to titanium via silanization. Physicochemical characterization by means of contact angle, Raman spectroscopy and XPS proved the successful and stable grafting of the molecules. The biological potential of the biointerfaces was measured with osteoblastic (Saos-2) cells both at short and long incubation periods. Biomolecule grafting (either the PLATF, RGD or KRSR) statistically improved (p < 0.05) cell attachment, spreading, proliferation and mineralization, compared to control titanium. Moreover, the molecular PLATF biointerface synergistically enhanced mineralization (p < 0.05) of Saos-2 cells compared to RGD or KRSR alone. These results indicate that dual-function coatings may serve to improve the bioactivity of medical implants by mimicking synergistic receptor binding.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

All-in-one trifunctional strategy: a cell adhesive, bacteriostatic and bactericidal coating for titanium implants

  • Hoyos Nogués, Mireia
  • Buxadera-Palomero, Judit
  • Ginebra Molins, Maria Pau
  • Manero Planella, José María
  • Gil Mur, Francisco Javier
  • Mas Moruno, Carlos
The authors thank the Spanish Government for financial support through a Ramon y Cajal grant of C.M.-M. (RYC-2015-18566) and Projects No. MAT2015-67183-R and MAT2017-83905-R (MINECO/FEDER), cofunded by the European Union through European Regional Development Funds, the Fundación Hergar, the Government of Catalonia (2014SGR-1333 and ICREA academia fellowship of M.-P.G), the Technical University of Catalonia (fellowship of M.H.-N.) and the European Commission (Marie Curie Career Integration Grant of C.M.-M, REA Grant Agreement No. 321985). The authors wish to express their gratitude to Dr. M. Dominguez and Trifon Trifonov for technical assistance with XPS analysis and SEM/FIB measurements, respectively, Strategies to inhibit initial bacterial adhesion are extremely important to prevent infection on biomaterial surfaces. However, the simultaneous attraction of desired eukaryotic cells remains a challenge for successful biomaterial-host tissue integration. Here we describe a method for the development of a trifunctional coating that repels contaminating bacteria, kills those that adhere, and promotes osteoblast adhesion. To this end, titanium surfaces were functionalized by electrodeposition of an antifouling polyethylene glycol (PEG) layer and subsequent binding of a peptidic platform with cell-adhesive and bactericidal properties. The physicochemical characterization of the samples via SEM, contact angle, FTIR and XPS analysis verified the successful binding of the PEG layer and the biomolecules, without altering the morphology and topography of the samples. PEG coatings inhibited protein adsorption and osteoblast-like (SaOS-2) attachment; however, the presence of cell adhesive domains rescued osteoblast adhesion, yielding higher values of cell attachment and spreading compared to controls (p < 0.05). Finally, the antibacterial potential of the coating was measured by live/dead assays and SEM using S. sanguinis as a model of early colonizer in oral biofilms. The presence of PEG layers significantly reduced bacterial attachment on the surfaces (p < 0.05). This antibacterial potential was further increased by the bactericidal peptide, yielding values of bacterial adhesion below 0.2% (p < 0.05). The balance between the risk of infection and the optimal osteointegration of a biomaterial is often described as “the race for the surface”, in which contaminating bacteria and host tissue cells compete to colonize the implant. In the present work, we have developed a multifunctional coating for a titanium surface that promotes the attachment and spreading of osteoblasts, while very efficiently inhibits bacterial colonization, thus holding promise for application in bone replacing applications., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Influence of connection type and platform diameter on titanium dental implants fatigue: non-axial loading cyclic test analysis

  • Nicolas-Silvente, Ana Isabel
  • Velasco-Ortega, Eugenio
  • Ortiz-Garcia, Iván
  • Jiménez Guerra, Álvaro
  • Monsalve-Guil, Loreto
  • Ayuso-Montero, Raul
  • Gil, FJ
  • Lopez-Lopez, Jose
The authors acknowledge the Spanish Government for financial support through a Ramon y Cajal grant of C.M.M. (RYC-2015-18566) and projects RTI2018-098075-B-C21, RTI2018-098075-B-C22, and MAT2017-83905-R, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU)., Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This study aims to evaluate the fatigue for different types of connections, external and internal, and different platform diameters. Three implant designs with the same length were used: (a) external hexagon/narrow platform; (b) internal double hexagon/narrow platform; (c) internal octagon/regular platform. A fatigue test was developed to establish the number of cycles needed before fracture. A 30º oblique load with a sinusoidal function of fatigue at a frequency of 15 Hz and 10% stress variation was applied to each system. The fatigue load limit (FLL) for design (a) was 190 N, being the nominal-curvature-moment (NCM) = 1.045; FLL = 150 N, with a NCM = 0.825 for (b), and FLL = 325 N, with a NCM = 1.788 for (c). The platform diameter affects the FLL, obtaining lower FLL on a narrow platform. The connection type interferes with the implant walls’ width, especially in narrow implants, making internal connections more unstable at this level. Long-term clinical studies to assess the restoration’s success rate and survival are mandatory., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Two different strategies to enhance osseointegration in porous titanium: inorganic thermo-chemical treatment versus organic coating by peptide adsorption

  • Ortiz-Hernández, Monica
  • Rappe, Katrin S.
  • Molmeneu, Meritxell
  • Mas-Moruno, Carlos
  • Guillem Martí, Jordi
  • Punset fuste, Miquel
  • CAPARROS, CRISTINA
  • Calero, Jose
  • franch, jordi
  • Fernandez-Fairen, Mariano
  • Gil, FJ
The authors thank the Spanish Government for financial support through a Ramon y Cajal grant of C.M.-M. (RYC-2015-18566) and Projects No. MAT2015-67183-R and MAT2017-83905-R (MINECO/FEDER), co-funded by the European Union through European Regional Development Funds, and the Government of Catalonia (2017 SGR1165)., In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Mineralization of titanium surfaces: biomimetic implants

  • Gil Mur, Francisco Javier
  • Manero Planella, José María
  • Rupérez de Gracia, Elisa
  • Velasco-Ortega, Eugenio
  • Jiménez-Guerra, Alvaro
  • Ortiz-Garcia, Iván
  • Monsalve Guil, Loreto
The authors thank the Spanish government for financial support through a Ramon y Cajal grant to C.M.-M. (RYC-2015-18566), and projects No. MAT2015-67183-R, MAT2017-83905-R, RTI2018-098075-B-C21, and RTI2018-098075-BC22, cofunded by the EU through the European Regional Development Funds (MINECO-FEDER, EU)., The surface modification by the formation of apatitic compounds, such as hydroxyapatite, improves biological fixation implants at an early stage after implantation. The structure, which is identical to mineral content of human bone, has the potential to be osteoinductive and/or osteoconductive materials. These calcium phosphates provoke the action of the cell signals that interact with the surface after implantation in order to quickly regenerate bone in contact with dental implants with mineral coating. A new generation of calcium phosphate coatings applied on the titanium surfaces of dental implants using laser, plasma-sprayed, laser-ablation, or electrochemical deposition processes produces that response. However, these modifications produce failures and bad responses in long-term behavior. Calcium phosphates films result in heterogeneous degradation due to the lack of crystallinity of the phosphates with a fast dissolution; conversely, the film presents cracks, which produce fractures in the coating. New thermochemical treatments have been developed to obtain biomimetic surfaces with calcium phosphate compounds that overcome the aforementioned problems. Among them, the chemical modification using biomineralization treatments has been extended to other materials, including composites, bioceramics, biopolymers, peptides, organic molecules, and other metallic materials, showing the potential for growing a calcium phosphate layer under biomimetic conditions., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Polyethylene glycol pulsed electrodeposition for the development of antifouling coatings on titanium

  • Buxadera-Palomero, Judit
  • Albó, Kim
  • Gil, FJ
  • Mas-Moruno, Carlos
  • Rodríguez, Daniel
This research was funded by the Technical University of Catalonia and Fundación Ramón Areces through the fellowship of J.B.-P. Funding was also provided by Fundación Ramón Areces through project “Biosellado”, and the Spanish Government through projects Nos. MAT2015-67183-R and MAT2017-83905-R, co-funded by the EU through European Regional Development Funds, and a Ramon y Cajal grant of C.M.-M. (RYC-2015-18566). The authors also thank the Government of Catalonia (Grant No. 2017 SGR-1165)., Titanium dental implants are widely used for the replacement of damaged teeth. However, bacterial infections at the interface between soft tissues and the implant can impair the functionality of the device and lead to failure. In this work, the preparation of an antifouling coating of polyethylene glycol (PEG) on titanium by pulsed electrodeposition was investigated in order to reduce Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) adhesion while maintaining human fibroblast adhesion. Different pulsed conditions were prepared and characterized by contact angle, Focused Ion Beam (FIB), Fourier Transformed Infrared Spectroscopy in the Attenuated Total Reflectance mode (ATR-FTIR), and X-ray photoelectron spectroscopy (XPS). XPS tested fibronectin adsorption. S. aureus, E. coli and human fibroblast adhesion was tested in vitro in both mono and co-culture settings. Physicochemical characterization proved useful for confirming the presence of PEG and evaluating the efficiency of the coating methods. Fibronectin adsorption decreased for all of the conditions, but an adsorption of 20% when compared to titanium was maintained, which supported fibroblast adhesion on the surfaces. In contrast, S. aureus and E. coli attachment on coated surfaces decreased up to 90% vs. control titanium. Co-culture studies with the two bacterial strains and human fibroblasts showed the efficacy of the coatings to allow for eukaryotic cell adhesion, even in the presence of pre-adhered bacteria., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

One-step liquid phase polymerization of HEMA by atmospheric-pressure plasma discharges for Ti dental implants

  • Buxadera-Palomero, Judit
  • Fricke, Katja
  • Reuter, Stephan
  • Gil, FJ
  • Rodriguez, Daniel
  • Canal Barnils, Cristina
This article is based upon work from COST Action TD1208, supported by COST (European Cooperation in Science and Technology). The authors acknowledge MINECO for their support through project PID2019-103892RB-I00 and projects RTI2018-098075-B-C21 and MAT2017-83905-R, co-funded by the EU through European Regional Development Funds. SR acknowledges funding by the German Ministry of Education and Research (BMBF, grant number 03Z2DN12). Data discussion and manuscript editing was performed during funding within the TransMedTech Institute by the Canada First Research Excellence Fund and Fonds de Recherche du Quebec (S.R.)., Dental implants can fail due to various factors, in which bad tissue integration is believed to have a significant role. Specific properties of the implant surface, such as its chemistry and roughness, are of paramount importance to address specific cell responses, such as the adsorption of proteins, as well as the adhesion and differentiation of cells, which are suitable for biomaterial and tissue engineering. In this study, an acrylate-containing coating was produced on titanium surfaces through the atmospheric pressure plasma treatment of a liquid precursor, 2-hydroxyethyl methacrylate. A hydrophilic coating was obtained, showing retention of the monomer chemistry as assessed by FTIR analysis and XPS. Enhanced fibroblast adhesion and decreased Staphylococcus aureus and Escherichia coli adhesion were recorded, showing that this is a suitable method to produce biocompatible coatings with a reduced bacterial adhesion., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Reseña (Review)

Antimicrobial peptides: powerful biorecognition elements to detect bacteria in biosensing technologies

  • Hoyos Nogués, Mireia
  • Gil Mur, Francisco Javier
  • Mas Moruno, Carlos
This article belongs to the Special Issue Antimicrobial Peptides and Peptidomimetics, This research was funded by the Spanish Government through a Ramon y Cajal grant of C.M.-M. (RYC-2015-18566) and Projects No. MAT2015-67183-R and MAT2017-83905-R (MINECO/FEDER), co-funded by the European Union through European Regional Development Funds, and the Government of Catalonia (2017 SGR116)., Bacterial infections represent a serious threat in modern medicine. In particular, biofilm treatment in clinical settings is challenging, as biofilms are very resistant to conventional antibiotic therapy and may spread infecting other tissues. To address this problem, biosensing technologies are emerging as a powerful solution to detect and identify bacterial pathogens at the very early stages of the infection, thus allowing rapid and effective treatments before biofilms are formed. Biosensors typically consist of two main parts, a biorecognition moiety that interacts with the target (i.e., bacteria) and a platform that transduces such interaction into a measurable signal. This review will focus on the development of impedimetric biosensors using antimicrobial peptides (AMPs) as biorecognition elements. AMPs belong to the innate immune system of living organisms and are very effective in interacting with bacterial membranes. They offer unique advantages compared to other classical bioreceptor molecules such as enzymes or antibodies. Moreover, impedance-based sensors allow the development of label-free, rapid, sensitive, specific and cost-effective sensing platforms. In summary, AMPs and impedimetric transducers combine excellent properties to produce robust biosensors for the early detection of bacterial infections., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A dual molecular biointerface combining RGD and KRSR sequences improves osteoblastic functions by synergizing integrin and cell-membrane proteoglycan binding

  • Hoyos Nogués, Mireia
  • Falgueras Batlle, Elena
  • Ginebra Molins, Maria Pau
  • Manero Planella, José María
  • Gil Mur, Francisco Javier
  • Mas Moruno, Carlos
Synergizing integrin and cell-membrane heparan sulfate proteoglycan signaling on biomaterials through peptidic sequences is known to have beneficial effects in the attachment and behavior of osteoblasts; however, controlling the exact amount and ratio of peptides tethered on a surface is challenging. Here, we present a dual molecular-based biointerface combining integrin (RGD) and heparin (KRSR)-binding peptides in a chemically controlled fashion. To this end, a tailor-made synthetic platform (PLATF) was designed and synthesized by solid-phase methodologies. The PLATF and the control linear peptides (RGD or KRSR) were covalently bound to titanium via silanization. Physicochemical characterization by means of contact angle, Raman spectroscopy and XPS proved the successful and stable grafting of the molecules. The biological potential of the biointerfaces was measured with osteoblastic (Saos-2) cells both at short and long incubation periods. Biomolecule grafting (either the PLATF, RGD or KRSR) statistically improved (p < 0.05) cell attachment, spreading, proliferation and mineralization, compared to control titanium. Moreover, the molecular PLATF biointerface synergistically enhanced mineralization (p < 0.05) of Saos-2 cells compared to RGD or KRSR alone. These results indicate that dual-function coatings may serve to improve the bioactivity of medical implants by mimicking synergistic receptor binding., Postprint (published version)