Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Clinically significant prostate cancer detection with deep learning in a multi-center magnetic resonance imaging study

  • Alzate-Grisales, Jesus Alejandro
  • Mora-Rubio, Alejandro
  • Pean-Teruel, Miguel
  • Navarro Beltran, Azahar
  • Ruiz Torres, Clara
  • Osca Garcia, Jose Manuel
  • Garcia-Garcia, Francisco
  • Tabares-Soto, Reinel
  • de la Iglesia-Vaya, Maria
  • Garcia-Gomez, Juan M
[EN] Accurate early detection of clinically significant prostate cancer is crucial for improving patient outcomes. However, traditional diagnostic methods such as Digital Rectal Exam and Prostate-Specific Antigen (PSA) tests often lack the sensitivity and specificity needed for effective diagnosis. This study presents an AI-based approach for csPCa classification using MRI data, incorporating both the PI-CAI Challenge dataset and a newly compiled, diverse BIMCV Prostate dataset comprising over 9000 MRI sessions from 16 healthcare centers in the Valencian Region. The methodology includes a robust preprocessing pipeline, featuring prostate segmentation with a custom-trained nnUNet model, and utilizes a 3D variant of EfficientNet-B7. To ensure robustness, we employed a transfer learning strategy where five models pretrained on PI-CAI were fine-tuned on the BIMCV dataset and aggregated using a stacked meta-learner. This ensemble approach yielded a Receiver Operating Characteristic Area Under the Curve of 0.816 on the independent hold-out set, significantly outperforming a non-pretrained baseline (AUC 0.71). Furthermore, we demonstrated that synthesizing missing ADC maps using a mono-exponential model serves as an effective data augmentation strategy, preventing data loss without introducing domain shift. Interpretability techniques such as occlusion sensitivity and guided backpropagation were employed to provide insights into the model's decision-making process, enhancing transparency. This research highlights the potential of AI-enhanced MRI techniques in advancing csPCa detection and diagnosis., This work is funded by the Spanish Ministry of Economic Affairs and Digital Transformation (Project MIA.2021.M02.0005 TARTAGLIA, from the Recovery, Resilience, and Transformation Plan financed by the European Union through Next Generation EU funds). TARTAGLIA takes place under the R&D Missions in Artificial Intelligence program, which is part of the Spain Digital 2025 Agenda and the Spanish National Artificial Intelligence Strategy.
Docta Complutense
Publication Artículo científico (JournalArticle)

Optimizing point source tracking in awake rat PET imaging: a comprehensive study of motion detection and best correction conditions

  • Arias Valcayo, Fernando
  • Galve Lahoz, Pablo
  • Udías Moinelo, José Manuel
  • Vaquero, Juan José
  • Desco, Manuel
  • Herraiz, Joaquín L.
  • López Herraiz, Joaquín
Preclinical PET animal studies require immobilization of the animal, typically accomplished through the administration of anesthesia, which may affect the radiotracer biodistribution. The use of (Formula presented.) F point sources attached to the rat head is one of the most promising methods for motion compensation in awake rat PET studies. However, the presence of radioactive markers may degrade image quality. In this study, we aimed to investigate the most favorable conditions for preclinical PET studies using awake rats with attached point sources. Firstly, we investigate the optimal activity conditions for the markers and rat-injected tracer using Monte Carlo simulations to determine the parameters of maximum detectability without compromising image quality. Additionally, we scrutinize the impact of delayed window correction for random events on marker detectability and overall image quality within these studies. Secondly, we present a method designed to mitigate the influence of rapid rat movements, which resulted in a medium loss of events of around 30%, primarily observed during the initial phase of the data acquisition. We validated our study with PET acquisitions from an awake rat within the acceptable conditions of activity and motion compensation parameters. This acquisition revealed an 8% reduction in resolution compared to a sedated animal, along with a 6% decrease in signal-to-noise ratio (SNR). These outcomes affirm the viability of our method for conducting awake preclinical brain studies.