Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Platelet-Derived Extracellular Vesicle Functionalization of Ti Implants

  • Antich-Rosselló, Miquel
  • Forteza-Genestra, Maria Antònia
  • Calvo, Javier
  • Gayà, Antoni
  • Monjo, Marta
  • Ramis, Joana Maria
[eng] Extracellular Vesicles (EVs) are biological nanovesicles that play a key role in cell communication. Their content includes active biomolecules such as proteins and nucleic acids, which present great potential in regenerative medicine. More recently, EVs derived from Platelet Lysate (PL) have shown an osteogenic capability comparable to PL. Besides, biomaterials are frequently used in orthopedics or dental restoration. Here, we provide a method to functionalize Ti surfaces with PL-derived EVs in order to improve their osteogenic properties. EVs are isolated from PL by size exclusion chromatography, and afterward Ti surfaces are functionalized with PL-EVs by drop casting. Functionalization is proven by EVs release and its biocompatibility by the lactate dehydrogenase (LDH) release assay.
Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Labeling of Extracellular Vesicles for Monitoring Migration and Uptake in Cartilage Explants

  • Forteza-Genestra, Maria Antònia
  • Antich-Rosselló, Miquel
  • Ortega, Francisco Gabriel
  • Ramis-Munar, Guillem
  • Calvo, Javier
  • Gayà, Antoni
  • Monjo, Marta
  • Ramis, Joana Maria
[eng] Extracellular vesicles (EVs) are used in different studies to prove their potential as a cell-free treatment due to their cargo derived from their cellular source, such as platelet lysate (PL). When used as treatment, EVs are expected to enter the target cells and effect a response from these. In this research, PL-derived EVs have been studied as a cell-free treatment for osteoarthritis (OA). Thus, a method was set up to label EVs and test their uptake on cartilage explants. PL-derived EVs are labeled with the lipophilic dye PKH26, washed twice through a column, and then tested in an 'in vitro' inflammation-driven OA model for 5 h after particle quantification by nanoparticle tracking analysis (NTA). Hourly, cartilage explants are fixed, paraffined, cut into 6 µm sections to mount on slides, and observed under a confocal microscope. This allows verification of whether EVs enter the target cells (chondrocytes) during this period and analyze their direct effect.
Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Nanostructured Implant–Tissue Interface Assessment Using a Three-Dimensional Gingival Tissue Equivalent

  • Llopis-Grimalt, Maria Antonia
  • Munar-Bestard, Marta
  • Ramis-Munar, Guillem
  • Smith, David
  • Starborg, Tobias
  • Kadler, Karl E.
  • Monjo, Marta
  • Ramis, Joana M.
[eng] Improved soft tissue integration (STI) around dental implants is key for implant success. The formation of an early and long-lasting transmucosal seal around the implant abutment might help to prevent peri-implantitis, one of the major causes of late implant failure. In natural teeth, collagen fibers are firmly inserted and fixed in the cementum of the tooth and emerge perpendicular to the gingival tissue. In contrast, around dental implants, collagen fibers run predominantly parallel to the implant surface, allowing bacterial migration into the peri-implant interface that might lead to peri-implantitis. Previous studies have shown that nanostructured Ti surfaces improve gingival cell response in monolayer cell cultures. Here, we aimed at evaluating the implant-tissue interface using a 3D gingival tissue equivalent (GTE). First, we evaluated the GTE response to a nanostructured (NN) and machined Ti surface after the stimulation with 'Porphyromonas gingivalis' lipopolysaccharide (LPS), to simulate peri-implantitis conditions. Thus, GTE viability, through MTT assay, the release of metalloproteinase-1 (MMP1) and its inhibitor (TIMP1) through ELISA, and the gene expression of extracellular matrix turnover genes by real-time RT-PCR were analyzed. Second, GTE-implant interaction was characterized by serial block face scanning electron microscopy, and collagen-1 orientation at the tissue-implant interface was analyzed by immunofluorescence. While a similar GTE response to LPS stimulation was found for both implant surfaces, a higher proportion of collagen oriented perpendicular to the implant was observed on the NN implant surface. Thus, our results indicate that the nanostructuration of titanium dental implant abutments could allow the correct orientation of collagen fibers and greater soft tissue sealing, while keeping biocompatibility levels and LPS response comparable.
Repositori Institucional UIB
Publication Artículo científico (JournalArticle)

Customizing the extracellular vesicles release and effect by strategizing surface functionalization of titanium

  • Antich-Rosselló, Miquel
  • Forteza-Genestra, Maria Antònia
  • Calvo, Javier
  • Gayà, Antoni
  • Monjo, Marta
  • Ramis, Joana Maria
[eng] Metallic material functionalization with Extracellular Vesicles (EVs) is a desirable therapeutic approach to improve regenerative procedures. Among the different functionalization strategies available, here we have compared drop casting on machined Ti surfaces, drop casting on nanostructured TiO<sub>2</sub> surfaces and polymeric entrapment with polydopamine. EVs are a heterogeneous population of communication nanovesicles released by cells that are being intensively investigated for their use in therapeutics. We have selected platelet derived EVs for Ti surface coating due to their demonstrated osteoinductive properties. Our results show that each functionalization strategy leads to differences in the size of EV populations attached to and released from the metallic implants, which, in turn, leads to variations in their osteogenic capability measured through alkaline phosphatase activity and calcium deposition. In conclusion, the functionalization strategy used has an important effect on the resulting implant functionality, probably due to the heterogeneous EVs nature. Thus, the methodological approach to metallic material functionalization should be carefully chosen when working with extracellular vesicles in order to obtain the desired therapeutic application.