Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Highest dominant frequency and rotor positions are robust markers of driver location during noninvasive mapping of atrial fibrillation: A computational study

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernandez-Aviles, Francisco
  • Berenfeld, Omer
  • Atienza, Felipe
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] BACKGROUND Dominant frequency (DF) and rotor mapping have been proposed as noninvasive techniques to guide localization of drivers maintaining atrial fibrillation (AF). OBJECTIVE The purpose of this study was to evaluate the robustness of both techniques in identifying atrial drivers noninvasively under the effect of electrical noise or model uncertainties. METHODS Inverse-computed DFs and phase maps were obtained from 30 different mathematical AF simulations. Epicardial highest dominant frequency (HDF) regions and rotor location were compared with the same inverse-computed measurements after addition of noise to the ECG, size variations of the atria, and linear or angular deviations in the atrial location inside the thorax. RESULTS Inverse-computed electrograms (EGMs) individually correlated poorly with the original EGMs in the absence of induced uncertainties (0.45 +/- 0.12) and were worse with 10-dB noise (0.22 +/- 0.11), 3-cm displacement (0.01 +/- 0.02), or 36 degrees rotation (0.02 +/- 0.03). However, inverse-computed HDF regions showed robustness against induced uncertainties: from 82% +/- 18% match for the best conditions, down to 73% +/- 23% for 10-dB noise, 77% +/- 21% for 5-cm displacement, and 60% +/- 22% for 36 degrees rotation. The distance from the inverse-computed rotor to the original rotor was also affected by uncertainties: 0.8 +/- 1.61 cm for the best conditions, 2.4 +/- 3.6 cm for 10-dB noise, 4.3 +/- 3.2 cm for 4-cm displacement, and 4.0 +/- 2.1 cm for 36 degrees rotation. Restriction of rotor detections to the HDF area increased rotor detection accuracy from 4.5 +/- 4.5 cm to 3.2 +/- 3.1 cm (P < .05) with 0-dB noise. CONCLUSION The combination of frequency and phase-derived measurements increases the accuracy of noninvasive localization of atrial rotors driving AF in the presence of noise and uncertainties in atrial location or size., This work was supported in part by grants from Generalitat Valenciana (ACIF/2013/021); Instituto de Salud Carlos III-FEDER (Fondo Europeo de Desarrollo Regional) and Ministerio de Ciencia e Innovacion (PI13-01882, PI13-00903, PI14/00857, PI16/01123, IJCI-2014-22178, DTS16/00160 and Red RIC RD12.0042.0001); Spanish Society of Cardiology (Clinical Research Grant 2015); and the National Heart, Lung, and Blood Institute (P01-HL039707, P01-HL087226, and Q1 R01-HL118304). Dr. Atienza served on the advisory board of Medtronic and Sorin. Dr. Berenfeld received research support from Medtronic and St. Jude Medical; and is a cofounder and Scientific Officer of Rhythm Solutions, Inc., Research and Development Director for S.A.S. Volta Medical, and consultant to Acutus Medical. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Presence and stability of rotors in atrial fibrillation: evidence and therapeutic implications

  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Climent, Andreu M.
  • Rodrigo Bort, Miguel
  • Fernandez-Aviles, Francisco
  • Atienza, Felipe
  • Berenfeld, Omer
[EN] Rotor-guided ablation has opened new perspectives into the therapy of atrial fibrillation (AF). Analysis of the spatio-temporal cardiac excitation patterns in the frequency and phase domains has demonstrated the importance of rotors in research models of AF, however, the dynamics and role of rotors in human AF are still controversial. In this review, the current knowledge gained through research models and patient data that support the notion that rotors are key players in AF maintenance is summarized. We report and discuss discrepancies regarding rotor prevalence and stability in various studies, which can be attributed in part to methodological differences among mapping systems. Future research for validation and improvement of current clinical electrophysiology mapping technologies will be crucial for developing mechanistic-based selection and application of the best therapeutic strategy for individual AF patient, being it, pharmaceutical, ablative, or other approach., This work was supported in part by grants from the Instituto de Salud Carlos III (Ministry of Economy and Competitiveness, Spain: PI13-01882, PI13-00903, and PI14/00857), Spanish Society of Cardiology (Clinical Research Grant 2015), Generalitat Valenciana (ACIF/2013/021), Innovation (Red RIC, PLE2009-0152), and NHLBI (P01-HL039707, P01-HL087226, and R01-HL118304).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ventricular Tachycardia and Early Fibrillation in Patients With Brugada Syndrome and Ischemic Cardiomyopathy Show Predictable Frequency-Phase Properties on the Precordial ECG Consistent With the Respective Arrhythmogenic Substrate

  • Calvo, David
  • Atienza, Felipe
  • Martinez, Laura
  • Ávila, Pablo
  • Rubín, José
  • Herreros, Benito
  • Arenal, Ángel
  • García-Fernández,Javier
  • Sebastian, Rafael
  • Martinez-Camblor, Pablo
  • Jalife, José
  • Berenfeld, Omer
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • FERRER ALBERO, ANA|||0000-0001-7642-916X
[EN] Background¿ Ventricular fibrillation (VF) has been proposed to be maintained by localized high-frequency sources. We tested whether spectral-phase analysis of the precordial ECG enabled identification of periodic activation patterns generated by such sources. Methods and Results¿Precordial ECGs were recorded from 15 ischemic cardiomyopathy and 15 Brugada syndrome (type 1 ECG) patients during induced VF and analyzed in the frequency-phase domain. Despite temporal variability, induced VF episodes lasting 19.6±7.9 s displayed distinctly high power at a common frequency (shared frequency, 5.7±1.1 Hz) in all leads about half of the time. In patients with Brugada syndrome, phase analysis of shared frequency showed a V1¿V6 sequence as would be expected from patients displaying a type 1 ECG pattern (P<0.001). Hilbert-based phases confirmed that the most stable sequence over the whole VF duration was V1¿V6. Analysis of shared frequency in ischemic cardiomyopathy patients with anteroseptal (n=4), apical (n=3), and inferolateral (n=4) myocardial infarction displayed a sequence starting at V1¿V2, V3¿V4, and V5¿V6, respectively, consistent with an activation origin at the scar location (P=0.005). Sequences correlated with the Hilbert-based phase analysis (P<0.001). Posterior infarction (n=4) displayed no specific sequence. On paired comparison, phase sequences during monomorphic ventricular tachycardia correlated moderately with VF (P<0.001). Moreover, there was a dominant frequency gradient from precordial leads facing the scar region to the contralateral leads (5.8±0.8 versus 5.4±1.1 Hz; P=0.004). Conclusions¿Noninvasive analysis of ventricular tachycardia and early VF in patients with Brugada syndrome and ischemic cardiomyopathy shows a predictable sequence in the frequency-phase domain, consistent with anatomic location of the arrhythmogenic substrate., This study was supported by the National Heart, Lung and Blood Institute (P01-HL039707, P01-HL087226 R01-HL118304); the Spanish Society of Cardiology, Arrhythmia and Electrophysiology Section; the Leducq Foundation, Paris, France; Centro Nacional de Investigaciones Cientificas, Madrid, Spain; Generalitat Valenciana, Valencia, Spain (PROMETEO/2012/030); VI Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica from the Ministerio de Economia y Competitividad of Spain (TIN2012-37546-C03-01); and the European Commission (European Regional Development Funds [ERDF]-FEDER)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mechanisms of Fractionated Electrograms Formation in the Posterior Left Atrium During Paroxysmal Atrial Fibrillation in Humans

  • Atienza, Felipe
  • Calvo, David
  • Almendral, Jesús
  • Zlochiver, Sharon
  • Grzeda, Krzysztof R.
  • González-Torrecilla, Esteban
  • Arenal, Ángel
  • Fernández-Avilés, Francisco
  • Berenfeld, Omer
  • Martínez Alzamora, Mª Nieves|||0000-0002-8305-7963
Objectives: The aim of this paper was to study mechanisms of formation of fractionated electrograms on the posterior left atrial wall (PLAW) in human paroxysmal atrial fibrillation (AF). Background: The mechanisms responsible for complex fractionated atrial electrogram formation during AF are poorly understood. Methods: In 24 patients, we induced sustained AF by pacing from a pulmonary vein. We analyzed transitions between organized patterns and changes in electrogram morphology leading to fractionation in relation to interbeat interval duration (systolic interval [SI]) and dominant frequency. Computer simulations of rotors helped in the interpretation of the results. Results: Organized patterns were recorded 31 ± 18% of the time. In 47% of organized patterns, the electrograms and PLAW activation sequence were similar to those of incoming waves during pulmonary vein stimulation that induced AF. Transitions to fractionation were preceded by significant increases in electrogram duration, spike number, and SI shortening (R 2 = 0.94). Similarly, adenosine infusion during organized patterns caused significant SI shortening leading to fractionated electrograms formation. Activation maps during organization showed incoming wave patterns, with earliest activation located closest to the highest dominant frequency site. Activation maps during transitions to fragmentation showed areas of slowed conduction and unidirectional block. Simulations predicted that SI abbreviation that heralds fractionated electrograms formation might result from a Doppler effect on wave fronts preceding an approaching rotor or by acceleration of a stationary or meandering, remotely located source. Conclusions: During induced AF, SI shortening after either drift or acceleration of a source results in intermittent fibrillatory conduction and formation of fractionated electrograms at the PLAW, This work was supported in part by grants from the Spanish Society of Cardiology (to Dr. Calvo); National Heart, Lung, and Blood Institute Grants P01-HL039707, P01-HL87226, and R01-HL060843 (to Dr. Berenfeld); and the Ministerio de Ciencia e Innovacion, Red RECAVA (to Drs. Atienza, Gonzalez-Torrecilla, Arenal, and Fernandez-Aviles) and the Centro Nacional de Investigaciones Cardiovasculares (proyecto CNIC-13) (to Drs. Atienza, Almendral, Gonzalez-Torrecilla, and Berenfeld). Dr. Atienza has served on the advisory board of and received lecture fees from Medtronic; and has received research funding from St. Jude Medical Spain. Dr. Berenfeld has received a research grant from St. Jude Medical. All other authors have reported that they have no relationships to disclose. Drs. Atienza and Calvo contributed equally to this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Technical Considerations on Phase Mapping for Identification of Atrial Reentrant Activity in Direct- and Inverse-Computed Electrograms

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernández-Avilés, Francisco
  • Berenfeld, Omer
  • Atienza, Felipe
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] [Background] Phase mapping has become a broadly used technique to identify atrial reentrant circuits for ablative therapy guidance. This work studies the phase mapping process and how the signal nature and its filtering affect the reentrant pattern characterization in electrogram (EGM), body surface potential mapping, and electrocardiographic imaging signals. [Methods and Results] EGM, body surface potential mapping, and electrocardiographic imaging phase maps were obtained from 17 simulations of atrial fibrillation, atrial flutter, and focal atrial tachycardia. Reentrant activity was identified by singularity point recognition in raw signals and in signals after narrow band-pass filtering at the highest dominant frequency (HDF). Reentrant activity was dominantly present in the EGM recordings only for atrial fibrillation and some atrial flutter propagations patterns, and HDF filtering allowed increasing the reentrant activity detection from 60% to 70% of time in atrial fibrillation in unipolar recordings and from 0% to 62% in bipolar. In body surface potential mapping maps, HDF filtering increased from 10% to 90% the sensitivity, although provoked a residual false reentrant activity ¿30% of time. In electrocardiographic imaging, HDF filtering allowed to increase ¿100% the time with detected rotors, although provoked the apparition of false rotors during 100% of time. Nevertheless, raw electrocardiographic imaging phase maps presented reentrant activity just in atrial fibrillation recordings accounting for ¿80% of time. [Conclusions] Rotor identification is accurate and sensitive and does not require additional signal processing in measured or noninvasively computed unipolar EGMs. Bipolar EGMs and body surface potential mapping do require HDF filtering to detect rotors at the expense of a decreased specificity., This study was supported, in part, by Universitat Politecnica de Valencia through its research initiative program; Generalitat Valenciana Grants (ACIF/2013/021); the Instituto de Salud Carlos III (Ministry of Economy and Competitiveness, Spain: PI13-01882, PI13-00903, PI14/00857, PI16/01123, TEC2013-46067-R, DTS16/0160, and IJCI-2014-22178); Spanish Society of Cardiology (Grant for Clinical Research in Cardiology 2015); Spanish Ministry of Science and Innovation (Red RIC RD12.0042.0001); and the National Heart, Lung, and Blood Institute (P01-HL039707, P01-HL087226, and Q1 R01-HL118304) and cofounded by FEDER.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

  • Martínez-Mateu, Laura
  • Sebastián Aguilar, Rafael
  • Rodriguez Matas, José Félix
  • Jalife, José
  • Berenfeld, Omer
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • FERRER ALBERO, ANA|||0000-0001-7642-916X
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35¿94% of the simulation time, depending on the basket¿s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures., This work was partially supported by: Programa Prometeu de la Conselleria d'Educacio Formacio I Ocupacio, Generalitat Valenciana (www.edu.gva.es/fio/index_es.asp). Award Number: PROMETEU/2016/088 to JS;"Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2013-2016" from the Ministerio de Economia, Industria y Competitividad of Spain, Agencia Estatal de Investigacion (www.mineco.gob.es) and the European Commission (European Regional Development Funds - ERDF -FEDER) (ec.europa.eu/regional_policy/es/funding/erdf/) Award Number: DPI2016-75799-R to JS; "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientado a los Retos de la Sociedad" from the Ministerio de Economia y Competitividad of Spain, Agencia Estatal de Investigacion (www.mineco.gob.es) and the European Commission (European Regional Development Funds - ERDF -FEDER) (ec.europa.eu/regional_policy/es/funding/erdf/) Award Number: TIN2014-59932-JIN to RS; National Institutes of Health (https://www.nih.gov/grants-funding). Award Numbers: R01-HL122352, P01-HL039707, P01-HL087236 and R01-HL118304 to OB; and research grant from Medtronic, Inc. (http://www.medtronic.com/us-en/about/foundation.html) to OB and JJ. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Noninvasive Localization of Maximal Frequency Sites of Atrial Fibrillation by Body Surface Potential Mapping

  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Millet Roig, José|||0000-0002-8879-003X
  • Climent, Andreu M.
  • Arenal, Ángel
  • Fernandez-Aviles, Francisco
  • Jalife, José
  • Atienza, Felipe
  • Berenfeld, Omer
Background—Ablation of high-frequency sources in patients with atrial fibrillation (AF) is an effective therapy to restore sinus rhythm. However, this strategy may be ineffective in patients without a significant dominant frequency (DF) gradient. The aim of this study was to investigate whether sites with high-frequency activity in human AF can be identified noninvasively, which should help intervention planning and therapy. Methods and Results—In 14 patients with a history of AF, 67-lead body surface recordings were simultaneously registered with 15 endocardial electrograms from both atria including the highest DF site, which was predetermined by atrial-wide real-time frequency electroanatomical mapping. Power spectra of surface leads and the body surface location of the highest DF site were compared with intracardiac information. Highest DFs found on specific sites of the torso showed a significant correlation with DFs found in the nearest atrium (ρ=0.96 for right atrium and ρ=0.92 for left atrium) and the DF gradient between them (ρ=0.93). The spatial distribution of power on the surface showed an inverse relationship between the frequencies versus the power spread area, consistent with localized fast sources as the AF mechanism with fibrillatory conduction elsewhere. Conclusions—Spectral analysis of body surface recordings during AF allows a noninvasive characterization of the global distribution of the atrial DFs and the identification of the atrium with the highest frequency, opening the possibility for improved noninvasive personalized diagnosis and treatment. (Circ Arrhythm Electrophysiol. 2013;6:294-301.), Dr Atienza served on the advisory board of Medtronic and has received research funding from St. Jude Medical Spain. Dr Jalife is a consultant for Topera, Inc., and for Rhythm Solutions, Inc. He is a coinvestigator in a research grant from Gilead, Inc. Dr Berenfeld is a cofounder and chief scientist of Rhythm Solutions, Inc. None of the companies disclosed financed the research described in this article. The other authors have no conflicts to report.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Minimal configuration of body surface potential mapping for discrimination of left versus right dominant frequencies during atrial fibrillation

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernández-Avilés, Francisco
  • Atienza, Felipe
  • Berenfeld, Omer
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background: Ablation of drivers maintaining atrial fibrillation (AF) has been demonstrated as an effective therapy. Drivers in the form of rapidly activated atrial regions can be noninvasively localized to either left or right atria (LA, RA) with body surface potential mapping (BSPM) systems. This study quantifies the accuracy of dominant frequency (DF) measurements from reduced-leads BSPM systems and assesses the minimal configuration required for ablation guidance. Methods: Nine uniformly distributed lead sets of eight to 66 electrodes were evaluated. BSPM signals were registered simultaneously with intracardiac electrocardiograms (EGMs) in 16 AF patients. DF activity was analyzed on the surface potentials for the nine leads configurations, and the noninvasive measures were compared with the EGM recordings. Results: Surface DF measurements presented similar values than panoramic invasive EGM recordings, showing the highest DF regions in corresponding locations. The noninvasive DFs measures had a high correlation with the invasive discrete recordings; they presented a deviation of <0.5 Hz for the highest DF and a correlation coefficient of >0.8 for leads configurations with 12 or more electrodes. Conclusions: Reduced-leads BSPM systems enable noninvasive discrimination between LA versus RA DFs with similar results as higher-resolution 66-leads system. Our findings demonstrate the possible incorporation of simplified BSPM systems into clinical planning procedures for AF ablation., This work was supported in part by Generalitat-Valenciana Grants [ACIF/2013/021]; Instituto de SaludCarlos III, Ministerio de Ciencia e Innovacion [PI13/00903, PI13-01882, PI14/00857, PI16/01123, TEC2013-46067-R, DTS16/0160 and IJCI-2014-22178] cofound by FEDER.; Spanish Society of Cardiology [Clinical research Grants 2015]; Ministerio de Ciencia e Innovacion [Red RICRD12.0042.0001]; and the National Heart, Lung, and Blood Institute [P01-HL039707, P01-HL087226 and R01-HL118304].