RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparative evaluation of the intermediate systems employed in two-stage refrigeration cycles driven by compound compressors

  • Cabello, R.
  • Torrella Alcaraz, Enrique
  • Llopis, R.
  • Sanchez, D.
[EN] This work presents an experimental evaluation, from an energy analysis point of view, for two of the most used inter-stage systems in two-stage vapour compression cycles driven by compound compressors: the direct liquid injection and subcooler systems. The evaluation, considers the two-stage cycle with no intermediate systems as reference cycle and was performed on a plant, driven by a compound compressor using the refrigerant R404A for an evaporating temperature range of -36 to -20 degrees C and for a condensing temperature range of 30-47 degrees C. The analysis of the results shows that the inter-stage systems determine the performance of the energy parameters, which are discussed in the paper. The configuration yielding the best results was the two-stage compression cycle with subcooler, since the cooling capacity and COP values for this configuration were the highest. Conversely, the two-stage compression cycle working with direct liquid injection showed lower performance from an energy point of view, though this configuration allows a substantial reduction of the discharge temperature., The authors would like to thank BANCAJA for its partial support to the project P1-1B2008-12.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental evaluation of HCFC-22 replacement by the drop-in fluids HFC-422A and HFC-417B for low temperature refrigeration applications

  • Llopis, R.
  • Cabello, R.
  • Sanchez, D.
  • Torrella Alcaraz, Enrique
  • Patino, J.
  • Sanchez, J. G.
The Regulation CE-1005/2009 has banned the use of virgin HCFC-22 in Europe from the 31st December 2009, because it contains chlorine, although its use is allowed up to the 31st December 2014 if it is recycled. Now, manufacturers are developing different free-chlorine drop-in solutions to replace the HCFC-22 in the existing equipment by non-ozone depleting substances in order to exhaust its remaining life. This work focuses on the experimental evaluation of two HCFC-22 drop-in solutions for low temperature applications, the HFC-422A and the HFC-417B, in a double-stage vapour compression plant driven by a compound compressor in an evaporating temperature range between -31 and -17 degrees C and in a condensing temperature range between 30 and 48 degrees C. The experimental results show that there is a reduction in cooling capacity and in COP with regard to the HCFC-22 operation, which is analysed and discussed in the paper., The authors would like to thank Fundacion Caixa Castello-Bancaixa (P1.1B2008-12) and to Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) for their economic support given to the present study.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant

  • Llopis, R.
  • Torrella Alcaraz, Enrique
  • Cabello, R.
  • Sanchez, D.
[EN] As a result of the ban of the CFC fluids in 2000 and the future limitation of HCFC fluids, which manufacture limit is the year 2010, refrigerant producers have been working to develop different mixtures, mainly based on HFC fluids, which emulate the properties of the former refrigerants used in refrigeration plants. At the moment, the HFC-404A and the HFC-507A are the more widely used fluids in Europe as replacement of the CFC-502 in plants operating at low temperatures. This work presents the experimental evaluation, from an energy point of view, of both refrigerants in the same refrigeration plant, which corresponds to a double-stage vapour compression plant driven by a compound compressor. The characterization was made for an evaporating temperature range between ¿36 and ¿20 °C for a constant condensing temperature of 40 °C., The authors are indebted to 'Fundacion Caixa Castello-Bancaixa' (P1.1B2008-12) and to the 'Ministerio de Medioambiente y Medio Rural y Marino' (200800050084716) for the support given to the present study.