Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A comparison of diesel sprays CFD modeling approaches: DDM versus Sigma-Y Eulerian atomization model

  • Desantes J.M.|||0000-0002-4124-9393
  • García-Oliver, José M|||0000-0002-2676-9681
  • Pastor Enguídanos, José Manuel|||0000-0003-4458-0353
  • Pandal-Blanco, Adrián
[EN] A comparison between the Σ-Y atomization model and a classical DDM approach has been carried out for diesel spray CFD simulations. The Σ-Y model, originally proposed by Vallet and Borghi (1999), is based on an Eulerian representation of the spray atomization and dispersion by means of a single-fluid variable density turbulent flow. The locally homogeneous flow approach has been applied in order to develop a spray vaporization model based on state relationships. A finite-volume solver for model equations has been created using the OpenFOAM CFD open-source C++ library (GarcíaOliver et al., 2013). In the case of the Lagrangian-DDM approach, the original dieselFoam solver of OpenFOAM is used. Model predictions have been compared to experimental measurements of free diesel sprays under vaporizing conditions from the database of the Engine Combustion Network (ECN). Accurate predictions of liquid and vapor spray penetration, as well as mixture fraction can be achieved for the nominal condition with both models, although DDM simulations tend to be less accurate. Additionally, near nozzle flow structure of the Spray A condition of ECN is also studied with both models. The conclusion is a more accurate prediction of the near-field internal structure of the spray in the case of the Eulerian model, due to both a higher mesh resolution and a more adequate modelling approach. Consequently, results shown in this work put in evidence the benefits of using an Eulerian model to predict qualitatively and accurately the diesel spray behaviour under different ambient conditions and injection pressures., Part of this work was possible thanks to the Programa de Ayudas de Investigacion y Desarrollo (PAID-2013) of the Universitat Polite`cnica de València. Also,we thank the collaboration of I. Garc´ıa Ayala and R. Redon Moreno, students of final degree project (PFC) at the Universitat Politècnica de València
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Coupled/decoupled spray simulation comparison of the ECN spray a condition with the Sigma-Y Eulerian atomization model

  • Desantes J.M.|||0000-0002-4124-9393
  • García-Oliver, José M|||0000-0002-2676-9681
  • Pastor Enguídanos, José Manuel|||0000-0003-4458-0353
  • Baldwin, E.
  • Schmidt, D. P.
  • Pandal-Blanco, Adrián
This work evaluates the performance of the Σ-Y Eulerian atomization model at reproducing the internal structure of a diesel spray in the near- field. In the study, three different computational domains have been used in order to perform 3D and 2D coupled simulations, where the internal nozzle flow and external spray are modeled in one continuous domain, and 2D decoupled simulations, where only the external spray is modeled. While the 3D simulation did the best job of capturing the dense zone of the spray, the 2D simulations also performed well, with the coupled 2D simulation slightly outperforming the decoupled simulation. The similarity in results between the coupled and the decoupled simulation show that internal and external flow calculations can be performed independently. In addition, the use of spatially averaged nozzle outlet conditions, in the case of an axisymmetric (single-hole) convergent nozzle, leads to a slightly worse near-field spray predictions but to an accurate far-field ones. Finally, a novel constraint on turbulent driven mixing multiphase flows is introduced which prevents the slip velocity from exceeding the magnitude of the turbulent fluctuations through a realizable Schmidt number. This constraint increased model stability, allowing for a 4x increase in Courant number., Authors acknowledge that part of this work was possible thanks to the Programa de Ayudas de Investigacion y Desarrollo (PAID-2013 3198) of the Universitat Politecnica de Valencia. Also this study was partially funded by the Spanish Ministry of Economy and Competitiveness in the frame of the COMEFF(TRA2014-59483-R) project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A computational analysis of local flow for reacting Diesel sprays by means of an Eulerian CFD model

  • Pandal-Blanco, Adrián
  • García-Oliver, José M|||0000-0002-2676-9681
  • Novella Rosa, Ricardo|||0000-0002-5123-6924
  • Pastor Enguídanos, José Manuel|||0000-0003-4458-0353
[EN] An implementation and validation of the coupled Sigma-gamma ADF model is presented in this work for reacting Diesel spray CFD simulations under a RANS turbulence modeling approach. An Approximated Diffusion Flamelet (ADF) model Michel et al. (2008) implemented in the OpenFOAM CFD open-source library by Winklinger (2014)15 fed with the spray description, i.e. mixing formation process, provided by the Sigma-gamma Eulerian atomization model Garcia-Oliver et al. (2013). In the present investigation, the Engine Combustion Network Spray A reference configuration is used for validation. Specifically, the model can provide accurate predictions of typical reacting spray metrics, such as the ignition delay and the lift-off length. Moreover, the internal structure is also fairly reproduced in terms of quasi-steady spatial distribution of formaldehyde and OH, related with low and high temperature reactions respectively. Additionally, modeling results have been compared to recent Particle image velocimetry (PIV) measurements Garcia-Oliver et al. (2017) under both inert and reacting conditions. Flow response to heat release is quantitatively predicted by the model, both in terms of local velocity increase as well as radial dilation. The model has been used to understand combustion-induced reduction in entrainment, in particular around the lift-off length location. Flow confinement does not seem to influence the global flame behaviour, even though some changes in the local flow hint can be observed when moving from an open to a closed domain. (C) 2017 Elsevier Ltd. All rights reserved., Authors acknowledge that this work was possible thanks to the Programa de Ayudas de Investigation y Desarrollo (PAID-2013 3198) of the Universitat Politecnica de Valencia. Also this study was partially funded by the Spanish Ministry of Economy and Competitiveness in the frame of the COMEFF(TRA2014-59483-R) project. Authors thank Gilles Bruneaux from IFPEN for the interesting suggestions and discussions.