Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl

  • González Martínez, Miguel Ángel|||0000-0002-5104-1262
  • Morais, Sergi|||0000-0002-3722-2358
  • Puchades, Rosa|||0000-0002-9329-1593
  • Maquieira, Angel|||0000-0003-4641-4957
  • Abad Fuentes, Antonio
  • Montoya Baides, Ángel
[EN] Immunosensor systems have been developed for the rapid and sensitive determination of pesticides, using the insecticide carbaryl as a model analyte. The systems are based on the principle of heterogeneous competitive enzyme immunoassay and used mouse monoclonal anti-carbaryl antibodies either in solution (indirect format) or immobilized (direct format). In both formats, enzyme label (horseradish peroxidase, HRP) and fluorometric detection were employed. In the direct format, antibodies were immobilized on a hydrazide-derivatized agarose gel, and 6-[((1-naphthyloxy)carbonyl)amino]hexanoic acid (CNH hapten) conjugated to HRP was used as the enzyme tracer. The limit of detection was 26 ng L-1 (11 min/assay), and the useful life of the sensor was 60−70 cycles. In the indirect format, CNH conjugated to bovine serum albumin was immobilized on an N-hydroxysuccinimide-derivatized agarose gel, and a rabbit anti-mouse antibody labeled with HRP was used as a secondary immunoreagent. The limit of detection was 284 ng L-1 (17 min/assay), and the useful life of the sensor was 160−200 cycles. The developed methods were applied to the analysis of commercial drinking water and apple juice spiked with carbaryl. Interassay RSD ranged from 9 to 39% in the direct format and from 4 to 28% in the indirect format. Recoveries were between 62 and 109% in the direct format and between 78 and 124% in the indirect format. The results were compared with those obtained by enzyme-linked immunosorbent assay as reference method and indicated the suitability of the immunosensor for quality control in water and food analysis, This project was supported by the CICYT project AMB 96-1079 and the DGCYT project PB 95-0740. M.A.G.-M. acknowledges a grant from the Fundacio´n Caja Madrid to carry out Ph.D. studies.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automation of Heterogeneous Enzyme Immunoassay for Atrazine. Comparison of Three Immobilization Supports

  • González Martínez, Miguel Ángel|||0000-0002-5104-1262
  • Morais, Sergi|||0000-0002-3722-2358
  • Puchades, Rosa|||0000-0002-9329-1593
  • Maquieira, Angel|||0000-0003-4641-4957
  • Marco, M.
  • Barceló, D.
[EN] Intensive agriculture associated with the use of large amounts of different pesticides, together with the growing concern about the potential contamination of ground water, have brought about the need for developing fast screening methods. This work presents the automation of an enzyme-linked immunosorbent assay for atrazine by means of a flow-through system. Three different solid supports for antibody immobilization were compared in a direct competitive assay format. Sensitivity reached in all cases was below the maximum level allowed in the EU (100 ng L-1). Cross-reactivity of atrazine-related compounds was also studied. The performance of the different supports is discussed regarding sensitivity and immunosurface regeneration., This work was supported by the CICYT project AMB 96-1079 and the DGCYT project PB 95-0740, Comission of the European Community (Contract ENV4-CT96-0333). M.A.González-Martínez acknowledges a grant from the Fundación Cajamadrid, Spain, to carry out a PhD degree.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An Immunosensor for the Automatic Determination of the Antifouling Agent Irgarol 1051 in Natural Waters

  • González Martínez, Miguel Ángel|||0000-0002-5104-1262
  • Puchades, Rosa|||0000-0002-9329-1593
  • Maquieira, Angel|||0000-0003-4641-4957
  • Penalva Villegas, José
  • Ballesteros, Berta
  • Marco, Maria Pilar
  • Barceló, Damià
[EN] The development of an immunosensor for analysis of the antifouling agent Irgarol 1051 (2-methylthio-4-tert-butylamin-6-cyclopropylamin-s-triazine) is described. The immunosensor is based on a heterogeneous competitive enzyme immunoassay and uses binder azlactone support with immobilized protein A/G. The flow-through immunosensor is completely automated and is able to carry out a whole analysis cycle in about 23 min. Competitive calibration curves have an I50 value of 0.053 μg/L (0.21 nM), with a limit of detection of 0.010 μg/L and a quantification dynamic range from 0.019 to 0.158 μg/L. The protein A/G support can be used for more than 600 assay cycles without loss of sensor performance. The sensor is prone to some interferences from tert-butyl-containing s-triazine compounds, such as terbutryn and terbumeton, but little inteference is shown for other s-triazine compounds, e.g., atrazine or simazine. The developed sensor is applied to the determination of trace levels of Irgarol 1051 in water samples such as Mediterranean marina and beach seawater, estuarine river water, and lake water, without any sample pretreatment other than adjusting the pH and ionic strength of samples to those of standards. Good correlation is achieved between the immunosensor results and ELISA or HPLC analyses., This work has been supported by the CICYT (AMB 96-1079), DGCYT (PB 95-0740), EC (environmental and climate contracts EVN4-CT95-0066 and EVN4-CT97-0476), and RIANA (ENV4-CT95-0066). J. P. acknowledges a grant from the Ministerio de Educación y Ciencia, Spain, to carry out Ph D. studies.