Skip to main content

DEPOSICION DE CAPA ATOMICA PARA EL CRECIMIENTO DE ABAJO-ARRIBA DE PELICULAS DE FASES MAX Y MXENOS A MEDIDA

PCIN-2017-134

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos Programación Conjunta Internacional
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre ASOC CIC NANOGUNE

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Rapid colorimetric detection of wound infection with a fluidic paper device

  • Hoyo, Javier
  • Bassegoda Puigdomenech, Arnau
  • Ferreres Cabanes, Guillem|||0000-0003-3138-8506
  • Hinojosa Caballero, Dolores
  • Gutierrez Capitan, Manuel
  • Baldi Coll, Antonio
  • Fernandez Sanchez, Cesar
  • Tzanov, Tzanko|||0000-0002-8568-1110
Current procedures for the assessment of chronic wound infection are time-consuming and require complex instruments and trained personnel. The incidence of chronic wounds worldwide, and the associated economic burden, urge for simple and cheap point-of-care testing (PoCT) devices for fast on-site diagnosis to enable appropriate early treatment. The enzyme myeloperoxidase (MPO), whose activity in infected wounds is about ten times higher than in non-infected wounds, appears to be a suitable biomarker for wound infection diagnosis. Herein, we develop a single-component foldable paper-based device for the detection of MPO in wound fluids. The analyte detection is achieved in two steps: (i) selective immunocapture of MPO, and (ii) reaction of a specific dye with the captured MPO, yielding a purple color with increasing intensity as a function of the MPO activity in infected wounds in the range of 20–85 U/mL. Ex vivo experiments with wound fluids validated the analytic efficiency of the paper-based device, and the results strongly correlate with a spectrophotometric assay., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Rapid colorimetric detection of wound infection with a fluidic paper device

  • Hoyo, Javier
  • Bassegoda Puigdomenech, Arnau
  • Ferreres Cabanes, Guillem
  • Hinojosa Caballero, Dolores
  • Gutierrez Capitan, Manuel
  • Baldi Coll, Antonio
  • Fernandez Sanchez, Cesar
  • Tzanov, Tzanko
Current procedures for the assessment of chronic wound infection are time-consuming and require complex instruments and trained personnel. The incidence of chronic wounds worldwide, and the associated economic burden, urge for simple and cheap point-of-care testing (PoCT) devices for fast on-site diagnosis to enable appropriate early treatment. The enzyme myeloperoxidase (MPO), whose activity in infected wounds is about ten times higher than in non-infected wounds, appears to be a suitable biomarker for wound infection diagnosis. Herein, we develop a single-component foldable paper-based device for the detection of MPO in wound fluids. The analyte detection is achieved in two steps: (i) selective immunocapture of MPO, and (ii) reaction of a specific dye with the captured MPO, yielding a purple color with increasing intensity as a function of the MPO activity in infected wounds in the range of 20–85 U/mL. Ex vivo experiments with wound fluids validated the analytic efficiency of the paper-based device, and the results strongly correlate with a spectrophotometric assay., Peer Reviewed, Postprint (published version)