Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Regional conduction velocities determined by noninvasive mapping are associated with arrhythmia-free survival after atrial fibrillation ablation

  • Invers-Rubio, Eric
  • Hernández-Romero, Ismael
  • Reventós-Presmanes, Jana
  • Ferró, Elisenda
  • Guichard, Jean Baptiste
  • Regany-Closa, Mariona
  • Pellicer-Sendra, Berta
  • Borrás, Roger
  • Tolosana, José María
  • Prat-Gonzalez, Susanna
  • Porta-Sanchez, Andreu
  • Arbelo, Elena
  • Guasch, Eduard
  • Sitges, Marta
  • Brugada, Josep
  • Roca-Luque, Ivo
  • Lluís Mont
  • TF Althoff
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Andreu M. Climent|||0000-0002-7260-8811
[EN] BACKGROUND Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 6 0.15 m/s vs 1.64 6 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 6 0.22 m/s vs 1.08 6 0.26 m/s; P < .0001). This average conduction velocity of the ¿slowest¿ segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P 5 .002). CONCLUSION This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy., This work is supported in part by grants from the European Union s Horizon Research and Innovation Programme under the Marie Sk1odowska-Curie Grant Agreement (860974; to M.S.G.); Instituto de Salud Carlos III, Spanish Government, Madrid, Spain (FIS_PI16/00435 FIS_CIBER16; to L.M.); Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018-003617, and RYC2018-024346-I; to A.M.C.), EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d Educació, Investigació, Cultura i Esport (ACIF/2020/265; to A.C.), and Spanish Agencia Estatal de Investigación (AEI), part of the Ministerio de Ciencia e Innovación, reference PID2020-119364RB-I00 (to A.C.).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

AF driver detection in pulmonary vein area by electropcardiographic imaging: Relation with a favorable outcome of pulmonary vein isolation

  • Fambuena-Santos, Carlos
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Hernández-Romero, Ismael
  • Molero-Alabau, Rubén
  • Atienza, Felipe
[EN] Pulmonary vein isolation (PVI) is the most successful treatment for atrial fibrillation (AF) nowadays. However, not all AF patients benefit from PVI. In this study, we evaluate the use of ECGI to identify reentries and relate rotor density in the pulmonary vein (PV) area as an indicator of PVI outcome. Rotor maps were computed in a set of 29 AF patients using a new rotor detection algorithm. The relationship between the distribution of reentrant activity and the clinical outcome after PVI was studied. The number of rotors and proportion of PSs in different atrial regions were computed and compared retrospectively in two groups of patients: patients that remained in sinus rhythm 6 months after PVI and patients with arrhythmia recurrence. The total number of rotors obtained was higher in patients returning to arrhythmia after the ablation (4.31 ± 2.77 vs. 3.58 ± 2.67%, p = 0.018). However, a significantly higher concentration of PSs in the pulmonary veins was found in patients that remained in sinus rhythm (10.20 ± 12.40% vs. 5.19 ± 9.13%, p = 0.011) 6 months after PVI. The results obtained show a direct relationship between the expected AF mechanism and the electrophysiological parameters provided by ECGI, suggesting that this technology offers relevant information to predict the clinical outcome after PVI in AF patients., This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 860974, PersonalizeAF, Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018-003617, and RYC2018-024346-I), EIT Health (SAVE-COR Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) and Spanish Agencia Estatal de Investigacion (AEI), part of the Ministerio de Ciencia e Innovacion, reference PID2020-119364RB-I00. *This publication reflects only the author's view and that the Agency is not responsible for any use that may be made of the information it contains.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation

  • Molero-Alabau, Rubén
  • Gonzalez-Ascaso, Ana
  • Hernández-Romero, Ismael
  • Lundbäck-Mompó, David
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Introduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and recording ECG electrodes distribution to compute ECGI during atrial fibrillation (AF).Methods: Torso meshes from 100 to 2000 nodes heterogeneously and homogeneously distributed were compared. Signals from nine AF realistic mathematical simulations were used for computing the ECGI. Results for each torso mesh were compared with the ECGI computed with a 4,000 nodes reference torso. In addition, real AF recordings from 25 AF patients were used to compute ECGI in torso meshes from 100 to 1,000 nodes. Results were compared with a reference torso of 2000 nodes. Torsos were remeshed either by reducing the number of nodes while maximizing the overall shape preservation and then assigning the location of the electrodes as the closest node in the new mesh or by forcing the remesher to place a node at each electrode location. Correlation coefficients, relative difference measurements and relative difference of dominant frequencies were computed to evaluate the impact on signal morphology of each torso mesh.Results: For remeshed torsos where electrodes match with a geometrical node in the mesh, all mesh densities presented similar results. On the other hand, in torsos with electrodes assigned to closest nodes in remeshed geometries performance metrics were dependent on mesh densities, with correlation coefficients ranging from 0.53 +/- 0.06 to 0.92 +/- 0.04 in simulations or from 0.42 +/- 0.38 to 0.89 +/- 0.2 in patients. Dominant frequency relative errors showed the same trend with values from 1.14 +/- 0.26 to 0.55 +/- 0.21 Hz in simulations and from 0.91 +/- 0.56 to 0.45 +/- 0.41 Hz in patients.Conclusion: The effect of mesh density in ECGI is minimal when the location of the electrode is preserved as a node in the mesh. Torso meshes constructed without imposing electrodes to constitute nodes in the torso geometry should contain at least 400 nodes homogeneously distributed so that a distance between nodes is below 4 cm., This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovacion (supported by FEDER Fondo Europeo de Desarrollo Regional PI17/01106, PEJ2018003617 and RYC2018-024346-I), EIT Health (Activity code 220385, EIT Health is supported by EIT, a body of the European Union), Generalitat Valenciana Conselleria d'Educacio, Investigacio, Cultura i Esport (ACIF/2020/265) and Spanish Agencia Estatal de Investigacion (AEI), part of the Ministerio de Ciencia e Innovacion, reference PID2020-119364RB-I00.