Skip to main content

LA INTERACCION BINOCULAR EN LA PERCEPCION DEL MOVIMIENTO: IMPLICACIONES EN LA ACTIVACION DE LOS MECANISMOS VISUALES INHIBITORIOS

PGC2018-093406-B-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema de I+D+i
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD COMPLUTENSE DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Docta Complutense
Publication Artículo científico (JournalArticle)

Interaction between motion scales: When performance in motion discrimination is worse for a compound stimulus than for its integrating components

  • Luna del Valle, Raúl
  • Serrano Pedraza, Ignacio
Motion direction discrimination becomes impaired when combinations of drifting high spatial frequency (HSF) and static low spatial frequency (LSF) patterns are merged into a compound stimulus. Such impairment has been suggested to occur due to an interaction between motion sensors tuned to coarse and fine scale spatial patterns. This interaction is modulated by different stimulus parameters like temporal frequency, size, the spectral components mixed, and their relative contrast. The present research precisely aims to explore in a deeper way the interaction’s dependency upon the spatial frequency and the relative contrast of the components when both move coherently. Two experiments were therefore performed measuring duration thresholds (Experiment 1) and proportion of correct responses (Experiment 2) in a motion direction discrimination task. Stimuli were vertical Gabor patches of 4 deg diameter horizontally drifting with a speed of 2 deg/sec. Simple LSF and HSF stimuli as well as complex stimuli where both components moved coherently (LSFm + HSFm) were used. These were grouped in the following LSF and HSF pairs: 0.25–0.75, 0.5–1.5, 1–3 and 2–6 c/deg. Each component had a Michelson contrast of 28% or 7%, giving rise to different relative contrast combinations. Most interestingly, the results show a decrease in performance for complex stimuli with respect to each of their simple components when the LSF component has a lower contrast than the HSF one. The decrease depends on the particular spatial frequencies mixed in a stimulus. Further knowledge about the inhibitory mechanism is thus provided, revealing its joint dependency upon contrast and spatial frequency.
Docta Complutense
Publication Artículo científico (JournalArticle)

Efficient estimation of stereo thresholds: What slope should be assumed for the psychometric function?

  • Serrano Pedraza, Ignacio
  • Vancleef, Kathleen
  • Herbert, William
  • Goodship, Nicola
  • Woodhouse, Maeve
  • Read, Jenny C. A.
Bayesian staircases are widely used in psychophysics to estimate detection thresholds. Simulations have revealed the importance of the parameters selected for the assumed subject’s psychometric function in enabling thresholds to be estimated with small bias and high precision. One important parameter is the slope of the psychometric function, or equivalently its spread. This is often held fixed, rather than estimated for individual subjects, because much larger numbers of trials are required to estimate the spread as well as the threshold. However, if this fixed value is wrong, the threshold estimate can be biased. Here we determine the optimal slope to minimize bias and maximize precision when measuring stereoacuity with Bayesian staircases. We performed 2- and 4AFC disparity detection stereo experiments in order to measure the spread of the disparity psychometric function in human observers assuming a Logistic function. We found a wide range, between 0.03 and 3.5 log10 arcsec, with little change with age. We then ran simulations to examine the optimal spread using the empirical data. From our simulations and for three different experiments, we recommend selecting assumed spread values between the percentiles 60–80% of the population distribution of spreads (these percentiles can be extended to other type of thresholds). For stereo thresholds, we recommend a spread around the value σ = 1.7 log10 arcsec for 2AFC (slope β = 4.3 /log10 arcsec), and around σ = 1.5 log10 arcsec for 4AFC (β = 4.9 /log10 arcsec). Finally, we compared a Bayesian procedure (ZEST using the optimal σ) with five Bayesian procedures that are versions of ZEST-2D, Psi, and Psi-marginal. In general, for the conditions tested, ZEST optimal σ showed the lowest threshold bias and highest precision.
Docta Complutense
Publication Artículo científico (JournalArticle)

ASTEROID stereotest v1.0: Lower stereo thresholds usingsmaller, denser and faster dots

  • Read, Jenny
  • Wong, Zhen Yi
  • Yek, Xinye
  • Wong, Ying Xin
  • Bachtoula González, Omar
  • Llamas Cornejo, Ichasus
  • Serrano Pedraza, Ignacio
Purpose: In 2019, we described ASTEROID, a new stereotest run on a 3D tabletcomputer which involves a four-alternative disparity detection task on a dynamicrandom-dot stereogram. Stereo thresholds measured with ASTEROID were wellcorrelated with, but systematically higher than (by a factor of around 1.5), thresh-olds measured with previous laboratory stereotests or the Randot Preschool clini-cal stereotest. We speculated that this might be due to the relatively large, sparsedots used in ASTEROID v0.9. Here, we introduce and test the stereo thresholdsand test-repeatability of the new ASTEROID v1.0, which uses precomputedimages to allow stereograms made up of much smaller, denser dots.Methods: Stereo thresholds and test/retest repeatability were tested and comparedbetween the old and new versions of ASTEROID (n = 75) and the Randot Circles(n = 31) stereotest, in healthy young adults.Results: Thresholds on ASTEROID v1.0 are lower (better) than on ASTEROIDv0.9 by a factor of 1.4, and do not differ significantly from thresholds on the Ran-dot Circles. Thresholds were roughly log-normally distributed with a mean of1.54 log 10 arcsec (35 arcsec) on ASTEROID v1.0 compared to 1.70 log 10 arcsec(50 arcsec) on ASTEROID v0.9. The standard deviation between observers wasthe same for both versions, 0.32 log 10 arcsec, corresponding to a factor of 2 aboveand below the mean. There was no difference between the versions in their test/retest repeatability, with 95% coefficient of repeatability = 0.46 log10 arcsec (afactor of 2.9 or 1.5 octaves) and a Pearson correlation of 0.8 (comparable to otherclinical stereotests).Conclusion: The poorer stereo thresholds previously reported with ASTEROIDv0.9 appear to have been due to the relatively large, coarse dots and low densityused, rather than to some other aspect of the technology. Employing the smalldots and high density used in ASTEROID v1.0, thresholds and test/retest repeata-bility are similar to other clinical stereotests.
Docta Complutense
Publication Artículo científico (JournalArticle)

Evidence for different spatiotemporal mechanisms using duration thresholds: An individual differences approach

  • Luna del Valle, Raúl
  • Serrano Pedraza, Ignacio
The study of motion perception through classical psychophysical methods has suggested that independent spatiotemporal filters acting over specific locations in retinal images carry out early motion processing. On the other hand, individual differences approaches have been able to identify a structure of spatiotemporal filters too. In this same fashion—through an individual differences approach—the present study aims to uncover a structure of spatiotemporal frequency selective motion mechanisms. This is done, for the first time, using supra-threshold contrast stimuli in a motion direction discrimination task. Two experiments were performed measuring duration thresholds for drifting 2D Gabor gratings of 0.25, 0.5, 0.75, 1, 1.5, 2, 3 and 6 c/deg. They moved with a speed of 2 deg/sec, with Michelson contrasts of 0.1 or 0.9 (Experiment 1) or had a contrast of 0.9 drifting with a temporal frequency of 2 Hz or 8 Hz (Experiment 2). Principal component analyses uncover three factors in each of four conditions. When Varimax-rotated, these are seen to be selective to spatial frequencies lower than 0.5 c/deg, intermediate ones from 0.5 to 1–1.5 c/deg, and frequencies greater than 1–1.5 c/deg. Direct Oblimin rotations indicate that factors are moderately correlated. Further analyses show very slight differences in the correlational structures between contrast conditions (0.1 vs. 0.9), and no differences between temporal frequency conditions (2 Hz vs. 8 Hz). To conclude, the idea of a three-factor structure in motion processing for low, intermediate, and high spatial frequencies is supported.
Docta Complutense
Publication Artículo científico (JournalArticle)

Taller Docta.. Evidence for different spatiotemporal mechanisms using duration thresholds: An individual differences approach

  • Luna, Raul
  • Serrano Pedraza, Ignacio
The study of motion perception through classical psychophysical methods has suggested that independent spatiotemporal filters acting over specific locations in retinal images carry out early motion processing. On the other hand, individual differences approaches have been able to identify a structure of spatiotemporal filters too. In this same fashion—through an individual differences approach—the present study aims to uncover a structure of spatiotemporal frequency selective motion mechanisms. This is done, for the first time, using supra-threshold contrast stimuli in a motion direction discrimination task. Two experiments were performed measuring duration thresholds for drifting 2D Gabor gratings of 0.25, 0.5, 0.75, 1, 1.5, 2, 3 and 6 c/deg. They moved with a speed of 2 deg/sec, with Michelson contrasts of 0.1 or 0.9 (Experiment 1) or had a contrast of 0.9 drifting with a temporal frequency of 2 Hz or 8 Hz (Experiment 2). Principal component analyses uncover three factors in each of four conditions. When Varimax-rotated, these are seen to be selective to spatial frequencies lower than 0.5 c/deg, intermediate ones from 0.5 to 1–1.5 c/deg, and frequencies greater than 1–1.5 c/deg. Direct Oblimin rotations indicate that factors are moderately correlated. Further analyses show very slight differences in the correlational structures between contrast conditions (0.1 vs. 0.9), and no differences between temporal frequency conditions (2 Hz vs. 8 Hz). To conclude, the idea of a three-factor structure in motion processing for low, intermediate, and high spatial frequencies is supported.
Docta Complutense
Publication Artículo científico (JournalArticle)

Achieving visual stability during smooth pursuit eye movements: Directional and confidence judgements favor a recalibration model

  • Luna del Valle, Raúl
  • Serrano Pedraza, Ignacio
  • Gegenfurtner, Karl R.
  • Schütz, Alexander C.
  • Souto, David
During smooth pursuit eye movements, the visual system is faced with the task of telling apart reafferent retinal motion from motion in the world. While an efference copy signal can be used to predict the amount of reafference to subtract from the image, an image-based adaptive mechanism can ensure the continued accuracy of this computation. Indeed, repeatedly exposing observers to background motion with a fixed direction relative to that of the target that is pursued leads to a shift in their point of subjective stationarity (PSS). We asked whether the effect of exposure reflects adaptation to motion contingent on pursuit direction, recalibration of a reference signal or both. A recalibration account predicts a shift in reference signal (i.e. predicted reafference), resulting in a shift of PSS, but no change in sensitivity. Results show that both directional judgements and confidence judgements about them favor a recalibration account, whereby there is an adaptive shift in the reference signal caused by the prevailing retinal motion during pursuit. We also found that the recalibration effect is specific to the exposed visual hemifield.