INNOVACIONES EN PLATAFORMAS ANALITICAS CON TECNICAS CROMATOGRAFICAS Y ESPECTROMETRICAS. DESAFIOS EN CARACTERIZACION, RECONOCIMIENTO DE PATRONES DE MUESTRA Y MICROEXTRACCION

PGC2018-098363-B-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema de I+D+i
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE MURCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Determination of cadmium in used engine oil, gasoline and diesel by electrothermal atomic absorption spectrometry using magnetic ionic liquid-based dispersive liquid-liquid microextraction

  • Aguirre Pastor, Miguel Ángel
  • Canals, Antonio
  • López-García, Ignacio
  • Hernández-Córdoba, Manuel
  • Aguirre Pastor, Miguel Ángel|||/items/2ded3973-b197-4677-af9e-89db8c79363f
  • Canals, Antonio|||/items/4a7548bb-9862-4dd9-bee4-559e2a77eb23
In this study, a sensitive and matrix-effect free analytical method for Cd determination in engine oils and fuel samples by dispersive liquid-liquid microextraction with electrothermal atomic absorption spectrometry has been successfully developed. The extractant solvent used for the microextraction procedure was a magnetic ionic liquid (MIL) (i.e., bis(1-ethyl-3-methylimidazolium) tetrathiocyanatocobaltate (II) [Emim]2[Co(SCN)4]), which presents a paramagnetic property, and allows an easy phase separation using a magnet. In order to eliminate the well-known drawbacks of direct introduction of MIL in the graphite furnace, a back-extraction procedure was performed to transfer the analyte into an aqueous phase. The main experimental factors affecting the extraction of Cd (i.e., amount of sample and MIL, extraction and back-extraction time and concentration and amount of nitric acid) were optimized using a multivariate analysis consisting in two steps: a Plackett-Burman design followed by a circumscribed central composite design. Under optimum conditions (i.e., amount of sample: 6.2 g; amount of MIL: 119 mg; extraction time: 1 min; amount of nitric acid: 200 mg; nitric acid concentration: 1 mol L-1 and back-extraction time: 1 min), the proposed analytical method was validated and successfully used to analyze three real-world samples (i.e., used engine oil, gasoline and diesel). The three samples were spiked at two levels (i.e., 10 and 20 μg kg-1 of Cd for used engine oil and 1 and 3 μg kg-1 of Cd for gasoline and diesel). RSD and recovery values were within the range of 6–11% and 95–110%, respectively.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Thermogravimetry coupled with mass spectrometry successfully used to quantify polyethylene and polystyrene microplastics in organic amendments

  • Martín de la Fuente, Alba
  • Marhuenda Egea, Frutos Carlos
  • Ros, Margarita
  • Pascual, José Antonio
  • Sáez-Tovar, José Antonio
  • Martínez Sabater, Encarnación
  • Peñalver, Rosa
  • Marhuenda Egea, Frutos Carlos|||/items/90bc5484-0530-4d50-815c-cc12afc6127d
The global consumption of plastic is growing year by year, producing small plastic pieces known as microplastics (MPs) that adversely affect ecosystems. The use of organic amendments (compost and manure) polluted with MPs affects the quality of agricultural soils, and these MPs can be incorporated into the food chain and negatively impact human health. Current European legislation only considers large plastic particles in organic amendments. There is no information regarding MP pollution. Thus, the development of a methodology to support future legislation ensuring the quality of agricultural soils and food safety is necessary. This proposed methodology is based on thermogravimetry coupled with mass spectrometry to quantify polyethylene and polystyrene (PE and PS) MPs through their mass spectrometry signal intensity of characteristic PE (m/z 41, 43 and 56) and PS (m/z 78 and 104) ions. This method has been validated with several organic amendments where the MP content ranged from 52.6 to 4365.7 mg kg−1 for PE-MPs and from 1.1 to 64.3 mg kg−1 for PS-MPs. The proposed methodology is a quick and robust analytical method to quantify MPs in organic amendments that could support new legislation.