Skip to main content

ANEURISMAS DE AORTA ASCENDENTE. PROGRESION DE LA DILATACION: ETIOPATOGENIA Y NUEVOS BIOMARCADORES DE IMAGEN PARA PREDECIR SU EVOLUCION

PI17/00381

•
Funding agency name Instituto de Salud Carlos III
Funding agency acronym ISCIII
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de Investigación en Salud
Call year 2017
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACION INSTITUTO DE INVESTIGACION VALLE DE HEBRON
Execution centre HOSPITAL VALLE DE HEBRON

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury

  • Gil-Sala, Daniel|||0000-0003-4885-5836
  • Guala, Andrea|||0000-0002-5006-8164
  • Garcia Reyes, Marvin
  • Azancot, María A.|||0000-0002-8447-1373
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Allegue Allegue, Nicolas
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Goncalves Martins, Gabriela
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Constenla Garcia, Ivan|||0000-0002-7107-2277
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Tello Díaz, Cristina
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
  • Bellmunt Montoya, Sergi|||0000-0002-2851-720X
Objective: Thoracic endovascular aortic repair (TEVAR) is widely used for the treatment of patients with blunt traumatic thoracic aortic injury (BTAI). However, aortic haemodynamic and biomechanical implications of this intervention are poorly investigated. This study aimed to assess whether patients treated by TEVAR following BTAI have thoracic aortic abnormalities in geometry, stiffness, and haemodynamics. Methods: Patients with BTAI treated by TEVAR at Vall d'Hebron Hospital between 1999 and 2019 were compared with propensity score matched healthy volunteers (HVs). All subjects underwent cardiovascular magnetic resonance (CMR) comprising a 4D flow CMR sequence. Spatially resolved aortic diameter, length, volume, and curvature were assessed. Pulse wave velocity, distensibility, and longitudinal strain (all measurements of aortic stiffness) were determined regionally. Moreover, advanced haemodynamic descriptors were quantified: systolic flow reversal ratio (SFRR), quantifying backward flow during systole, and in plane rotational flow (IRF), measuring in plane strength of helical flow. Results: Twenty-six BTAI patients treated by TEVAR were included and matched with 26 HVs. They did not differ in terms of age, sex, and body surface area. Patients with TEVAR had a larger and longer ascending aorta (AAo) and marked abnormalities in local curvature. Aortic stiffness was greater in the aortic segments proximal and distal to TEVAR compared with controls. Moreover, TEVAR patients presented strongly altered flow dynamics compared with controls: a reduced IRF from the distal AAo to the proximal descending aorta and an increased SFRR in the whole thoracic aorta. These differences persisted adjusting for cardiovascular risk factors and were independent of time elapsed since TEVAR implantation. Conclusion: At long term follow up, previously healthy patients who underwent TEVAR implantation following BTAI had increased diameter, length and volume of the ascending aorta, and increased aortic stiffness and abnormal flow patterns in the whole thoracic aorta compared with matched controls. Further studies should address whether these alterations have clinical implications.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Impact of valve-sparing aortic root replacement on aortic fluid dynamics and biomechanics in patients with syndromic heritable thoracic aortic disease

  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Guala, Andrea|||0000-0002-5006-8164
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Fernandez-Galera, Rubén
  • Valente, Filipa|||0000-0002-5569-3292
  • Casas, Guillem|||0000-0001-7122-320X
  • Oliveró, Ruperto|||0000-0002-0888-8572
  • Ferrer-Cornet, Marta
  • Bragulat-Arévalo, Mireia
  • Carrasco-Poves, Alejandro
  • Garrido-Oliver, Juan|||0000-0002-5806-2031
  • Morales-Galán, Alberto
  • Johnson, Kevin M.
  • Wieben, Oliver
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Rodriguez-Palomares, José F
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms remain unclear. This prospective, longitudinal study evaluates the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients. Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two time-resolved three-dimensional phase-contrast cardiovascular magnetic resonance (4D flow CMR) studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two matched cohorts of 40 healthy volunteers (HV) and 16 sHTAD patients without indication for aortic root replacement (sHTAD-NSx) with available 4D flow CMR were included for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV), and aortic strain were analyzed in the ascending (AscAo) and descending aorta (DescAo). All patients with sHTAD presented altered hemodynamics and increased stiffness (p < 0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9 m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3 m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF -2.2 vs 10.4 cm 2 /s in HV, p = 0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p = 0.002), and decreased WSS (0.36 vs 0.47 N/m 2 in HV, p = 0.004) in the proximal DescAo. After VSARR, proximal DescAo IRF (p = 0.010) and circumferential WSS increased (p = 0.011), no longer differing from HV, but SFRR, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3 cm 2 /s, p = 0.047). Most AscAo flow alterations were restored to physiological values after VSARR. In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Estimating nonlinear anisotropic properties of healthy and aneurysm ascending aortas using magnetic resonance imaging

  • Latorre Molins, Álvaro T.
  • Guala, Andrea|||0000-0002-5006-8164
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Rodríguez Palomares, José Fernando|||0000-0002-8822-5532
  • Martínez Barca, Miguel Ángel
  • Peña Baquedano, Estefanía
An ascending aortic aneurysm is an often asymptomatic localized dilatation of the aorta. Aortic rupture is a life-threatening event that occurs when the stress on the aortic wall exceeds its mechanical strength. Therefore, patient-specific finite element models could play an important role in estimating the risk of rupture. This requires not only the geometry of the aorta but also the nonlinear anisotropic properties of the tissue. In this study, we presented a methodology to estimate the mechanical properties of the aorta from magnetic resonance imaging (MRI). As a theoretical framework, we used finite element models to which we added noise to simulate clinical data from real patient geometry and different properties of healthy and aneurysmal aortic tissues collected from the literature. The proposed methodology considered the nonlinear properties, the zero pressure geometry, the heart motion, and the external tissue support. In addition, we analyzed the aorta as a homogeneous material and as a heterogeneous model with different properties for the ascending and descending parts. The methodology was also applied to pre-surgical, in vivo MRI data of a patient who underwent surgery during which an aortic wall sample was obtained. The results were compared with those obtained from ex vivo biaxial test of the patient's tissue sample. The methodology showed promising results after successfully recovering the nonlinear anisotropic material properties of all analyzed cases. This study demonstrates that the variable used during the optimization process can affect the result. In particular, variables such as principal strains were found to obtain more realistic materials than the displacement field.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Versican accumulation drives Nos2 induction and aortic disease in Marfan syndrome via Akt activation

  • Ruiz-Rodríguez, María Jesús
  • Oller, Jorge
  • Martínez-Martínez, Sara
  • Alarcón-Ruiz, Iván
  • Toral, Marta
  • Sun, Yilin
  • Colmenar, Ángel
  • Méndez-Olivares, María José
  • López-Maderuelo, Dolores
  • Kern, Christine B.
  • Nistal Herrera, Juan Francisco
  • Evangelista, Arturo
  • Teixido-Tura, Gisela
  • Campanero, Miguel R.
  • Redondo, Juan Miguel
The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia e Innovación (MCIN) and the Pro CNIC Foundation), the CBMSO is supported by Consejo Superior de Investigaciones Científicas and Universidad Autónoma de Madrid. CBMSO and CNIC are Severo Ochoa Centers of Excellence (grants CEX2021-001154-S and CEX2020-001041-S, respectively) funded by MICIN/AEI/10.13039/501100011033. The project leading to these results has received funding from “La Caixa” Banking Foundation under project codes HR18-00068 (to MRC and JMR); Spanish Ministerio de Ciencia e Innovación grant RTI2018-099246-BI00 (MICIU/AEI/FEDER, UE) to JMR, and grants PID2020-115217RB-100 and PID2021-122388OB-100 to MRC and JMR, respectively, funded by MCIN/AEI/10.13039/501100011033; Instituto de Salud Carlos III (CIBER-CV CB16/11/00264 and CB16/11/00479; and grants PI17/00381 to GT-T and PI21/00084 (co-funded by Fondo Europeo de Desarrollo Regional (FEDER)) to JFN); Fundacio La Marato TV3 (20151330 to JMR); Instituto de Investigación Sanitaria Marqués de Valdecilla (IDIVAL) (INNVAL 21/24) to JFN; The Marfan Foundation USA Faculty grant 2017 MRF/1701 (to JMR); Fundación MERCK; Fundación Española de Enfermedades Raras 2022 and V-Ayudas “Muevete por los que no pueden 2021” (to JO); and Spanish Ministerio de Ciencia e Innovación contracts FPI (BES-2016-077649) to MJR-R; Sara Borrell (CD18/00028) and Juan de la Cierva (IJC2020-044581-I) to MT; Ramón y Cajal (RYC2021-033343-I) to JO; and FPU (20/04814) to IA-R.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study

  • Teixido-Tura, Gisela
  • Servato, Maria Luz
  • De Carvalho Negrao Valente, Filipa Xavier
  • Garrido Oliver, Juan
  • Galián Gay, Laura
  • Gutierrez García-Moreno, Laura
  • Fernández Galera, Ruben
  • Casas Masnou, Guillem
  • González Alujas, Teresa
  • Cuellar Calabria, Hug
  • Ferreira González, Ignacio
  • Evangelista Masip, Artur
  • Guala, Andrea
  • Dux-Santoy Hurtado, Lydia
  • Rodríguez Palomares, Jose Fernando
  • Ruiz Muñoz, Aroa
Aortic dissection; Aortic stiffness; Magnetic resonance imaging, Dissecció aòrtica; Rigidesa aòrtica; Imatges per ressonància magnètica, Disección aórtica; Rigidez aórtica; Imágenes de resonancia magnética, Background Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Methods Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Results Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. Conclusions In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI17/00381 and PI20/01727), the Spanish Ministry of Science, Innovation and Universities (RTC2019-007280–1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015 and SEC/FEC-INV-CLI 21/030) and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Guala A. has received funding from Spanish Ministry of Science, Innovation and Universities (IJC2018-037349-I).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Aortic disease in Marfan syndrome is caused by overactivation of sGC-PRKG signaling by NO

  • de la Fuente-Alonso, Andrea
  • Alfayate, Alvaro
  • Ruiz-Rodríguez, María Jesús
  • Bonzón-Kulichenko, Elena
  • Teixido Tura, Gisela
  • Evangelista Masip, Artur
  • Toral, Marta
Aneurysm; Aortic diseases; Marfan syndrome, Aneurisma; Malalties aòrtiques; Síndrome de Marfan, Aneurisma; Enfermedades aórticas; Síndrome de Marfan, Thoracic aortic aneurysm, as occurs in Marfan syndrome, is generally asymptomatic until dissection or rupture, requiring surgical intervention as the only available treatment. Here, we show that nitric oxide (NO) signaling dysregulates actin cytoskeleton dynamics in Marfan Syndrome smooth muscle cells and that NO-donors induce Marfan-like aortopathy in wild-type mice, indicating that a marked increase in NO suffices to induce aortopathy. Levels of nitrated proteins are higher in plasma from Marfan patients and mice and in aortic tissue from Marfan mice than in control samples, indicating elevated circulating and tissue NO. Soluble guanylate cyclase and cGMP-dependent protein kinase are both activated in Marfan patients and mice and in wild-type mice treated with NO-donors, as shown by increased plasma cGMP and pVASP-S239 staining in aortic tissue. Marfan aortopathy in mice is reverted by pharmacological inhibition of soluble guanylate cyclase and cGMP-dependent protein kinase and lentiviral-mediated Prkg1 silencing. These findings identify potential biomarkers for monitoring Marfan Syndrome in patients and urge evaluation of cGMP-dependent protein kinase and soluble guanylate cyclase as therapeutic targets.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Impact of valve-sparing aortic root replacement on aortic fluid dynamics and biomechanics in patients with syndromic heritable thoracic aortic disease

  • Fernández Galera, Ruben
  • Ferrer Cornet, Marta
  • Bragulat Arévalo, Mireia
  • Carrasco-Poves, Alejandro
  • Ferreira González, Ignacio
  • Teixido-Tura, Gisela
  • Dux-Santoy Hurtado, Lydia
  • Ruiz Muñoz, Aroa
  • Guala, Andrea
  • Galian-Gay, Laura
  • Valente, Filipa
  • Casas, Guillem
  • Oliveró, Ruperto
  • Garrido-Oliver, Juan
  • Morales-Galan, Alberto
  • Evangelista Masip, Arturo
  • Rodríguez Palomares, José F
Fluid dynamics; Syndromic heritable thoracic aortic disease; Aortic root replacement, Dinàmica de fluids; Malaltia aòrtica toràcica hereditària sindròmica; Substitució de l'arrel aòrtica, Dinámica de fluidos; Enfermedad aórtica torácica hereditaria sindrómica; Reemplazo de la raíz aórtica, Background Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms remain unclear. This prospective, longitudinal study evaluates the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients. Methods Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two time-resolved three-dimensional phase-contrast cardiovascular magnetic resonance (4D flow CMR) studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two matched cohorts of 40 healthy volunteers (HV) and 16 sHTAD patients without indication for aortic root replacement (sHTAD-NSx) with available 4D flow CMR were included for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV), and aortic strain were analyzed in the ascending (AscAo) and descending aorta (DescAo). Results All patients with sHTAD presented altered hemodynamics and increased stiffness (p < 0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9 m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3 m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF −2.2 vs 10.4 cm2/s in HV, p = 0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p = 0.002), and decreased WSS (0.36 vs 0.47 N/m2 in HV, p = 0.004) in the proximal DescAo. After VSARR, proximal DescAo IRF (p = 0.010) and circumferential WSS increased (p = 0.011), no longer differing from HV, but SFRR, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3 cm2/s, p = 0.047). Most AscAo flow alterations were restored to physiological values after VSARR. Conclusion In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI17/00381, PI20/01727, and PI21/00448), the Spanish Ministry of Science, Innovation and Universities (FORT23/00034, RTC2019-007280-1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015, SEC/FEC-INV-CLI 21/030, and SEC/FEC-INV-CLI 23/08), and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Andrea Guala has received funding from “la Caixa” Foundation (LCF/BQ/PR22/11920008). Juan Garrido-Oliver has received funding from Secretaria d'Universitats i Recerca del Departament de Recerca i Universitats de la Generalitat de Catalunya i del Fons Europeu Social Plus (AGAUR-FI 2023 FI-1 00322 Joan Oró).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Versican accumulation drives Nos2 induction and aortic disease in Marfan syndrome via Akt activation

  • Ruiz-Rodriguez, Maria Jesus
  • Oller Pedrosa, Jorge
  • Martínez-Martínez, Sara
  • Alarcon Ruiz, Ivan
  • Toral, Marta
  • Sun, YiLin
  • Teixido-Tura, Gisela
Aortic aneurysm; Marfan syndrome; Versican, Aneurisma aòrtic; Síndrome de Marfan; Versican, Aneurisma aortico; Síndrome de Marfan; Versican, Thoracic aortic aneurysm and dissection (TAAD) is a life-threatening condition associated with Marfan syndrome (MFS), a disease caused by fibrillin-1 gene mutations. While various conditions causing TAAD exhibit aortic accumulation of the proteoglycans versican (Vcan) and aggrecan (Acan), it is unclear whether these ECM proteins are involved in aortic disease. Here, we find that Vcan, but not Acan, accumulated in Fbn1C1041G/+ aortas, a mouse model of MFS. Vcan haploinsufficiency protected MFS mice against aortic dilation, and its silencing reverted aortic disease by reducing Nos2 protein expression. Our results suggest that Acan is not an essential contributor to MFS aortopathy. We further demonstrate that Vcan triggers Akt activation and that pharmacological Akt pathway inhibition rapidly regresses aortic dilation and Nos2 expression in MFS mice. Analysis of aortic tissue from MFS human patients revealed accumulation of VCAN and elevated pAKT-S473 staining. Together, these findings reveal that Vcan plays a causative role in MFS aortic disease in vivo by inducing Nos2 via Akt activation and identify Akt signaling pathway components as candidate therapeutic targets., The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia e Innovación (MCIN) and the Pro CNIC Foundation), the CBMSO is supported by Consejo Superior de Investigaciones Científicas and Universidad Autónoma de Madrid. CBMSO and CNIC are Severo Ochoa Centers of Excellence (grants CEX2021-001154-S and CEX2020-001041-S, respectively) funded by MICIN/AEI/10.13039/501100011033. The project leading to these results has received funding from “La Caixa” Banking Foundation under project codes HR18-00068 (to MRC and JMR); Spanish Ministerio de Ciencia e Innovación grant RTI2018-099246-B-I00 (MICIU/AEI/FEDER, UE) to JMR, and grants PID2020-115217RB-100 and PID2021-122388OB-100 to MRC and JMR, respectively, funded by MCIN/AEI/10.13039/501100011033; Instituto de Salud Carlos III (CIBER-CV CB16/11/00264 and CB16/11/00479; and grants PI17/00381 to GT-T and PI21/00084 (co-funded by Fondo Europeo de Desarrollo Regional (FEDER)) to JFN); Fundacio La Marato TV3 (20151330 to JMR); Instituto de Investigación Sanitaria Marqués de Valdecilla (IDIVAL) (INNVAL 21/24) to JFN; The Marfan Foundation USA Faculty grant 2017 MRF/1701 (to JMR); Fundación MERCK-Fundación Española de Enfermedades Raras 2022 and V-Ayudas “Muévete por los que no pueden 2021” (to JO); and Spanish Ministerio de Ciencia e Innovación contracts FPI (BES-2016-077649) to MJR-R; Sara Borrell (CD18/00028) and Juan de la Cierva (IJC2020-044581-I) to MT; Ramón y Cajal (RYC2021-033343-I) to JO; and FPU (20/04814) to IA-R.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve

  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Guala, Andrea|||0000-0002-5006-8164
  • Sotelo, Julio
  • Uribe, Sergio
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Hurtado, Daniel E.
  • Valente, Filipa|||0000-0002-5569-3292
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Gutiérrez García-Moreno, Laura
  • González-Alujas, Teresa
  • Johnson, Kevin M.
  • Wieben, Oliver
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
Supplemental Digital Content is available in the text. To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Fluid-structure interaction simulations outperform computational fluid dynamics in the description of thoracic aorta haemodynamics and in the differentiation of progressive dilation in Marfan syndrome patients

  • Pons, Ramon|||0000-0003-4273-9084
  • Guala, Andrea|||0000-0002-5006-8164
  • Rodríguez-Palomares, J. F.
  • Cajas, J. C.
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Molins, J. J.
  • Vázquez, Mariano|||0000-0002-2526-6708
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Martorell, Jordi|||0000-0002-2043-2762
Abnormal fluid dynamics at the ascending aorta may be at the origin of aortic aneurysms. This study was aimed at comparing the performance of computational fluid dynamics (CFD) and fluid-structure interaction (FSI) simulations against four-dimensional (4D) flow magnetic resonance imaging (MRI) data; and to assess the capacity of advanced fluid dynamics markers to stratify aneurysm progression risk. Eight Marfan syndrome (MFS) patients, four with stable and four with dilating aneurysms of the proximal aorta, and four healthy controls were studied. FSI and CFD simulations were performed with MRI-derived geometry, inlet velocity field and Young's modulus. Flow displacement, jet angle and maximum velocity evaluated from FSI and CFD simulations were compared to 4D flow MRI data. A dimensionless parameter, the shear stress ratio (SSR), was evaluated from FSI and CFD simulations and assessed as potential correlate of aneurysm progression. FSI simulations successfully matched MRI data regarding descending to ascending aorta flow rates (R 2 = 0.92) and pulse wave velocity (R 2 = 0.99). Compared to CFD, FSI simulations showed significantly lower percentage errors in ascending and descending aorta in flow displacement (-46% ascending, -41% descending), jet angle (-28% ascending, -50% descending) and maximum velocity (-37% ascending, -34% descending) with respect to 4D flow MRI. FSI- but not CFD-derived SSR differentiated between stable and dilating MFS patients. Fluid dynamic simulations of the thoracic aorta require fluid-solid interaction to properly reproduce complex haemodynamics. FSI- but not CFD-derived SSR could help stratifying MFS patients
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta, a 4D flow cardiovascular magnetic resonance study

  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Guala, Andrea|||0000-0002-5006-8164
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Servato, Maria Luz
  • Valente, Filipa|||0000-0002-5569-3292
  • Garrido-Oliver, Juan|||0000-0002-5806-2031
  • Galian-Gay, Laura|||0000-0001-6828-5928
  • Gutiérrez García-Moreno, Laura
  • Fernandez-Galera, Rubén
  • Casas, Guillem|||0000-0001-7122-320X
  • González-Alujas, Teresa
  • Cuellar-Calabria, Hug|||0000-0003-2197-4990
  • Johnson, Kevin M.
  • Wieben, Oliver
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events. The online version contains supplementary material available at 10.1186/s12968-022-00852-6.
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

False lumen rotational flow and aortic stiffness are associated with aortic growth rate in patients with chronic aortic dissection of the descending aorta: a 4D flow cardiovascular magnetic resonance study

  • Teixido Tura, Gisela
  • Servato, Maria Luz
  • De Carvalho Negrao Valente, Filipa Xavier
  • Garrido Oliver, Juan
  • Galián Gay, Laura
  • Gutierrez García-Moreno, Laura
  • Fernández Galera, Ruben
  • Casas Masnou, Guillem
  • González Alujas, Teresa
  • Cuellar Calabria, Hug
  • Ferreira González, Ignacio
  • Evangelista Masip, Artur
  • Guala, Andrea
  • Dux-Santoy Hurtado, Lydia
  • Rodríguez Palomares, Jose Fernando
  • Ruiz Muñoz, Aroa
Aortic dissection; Aortic stiffness; Magnetic resonance imaging, Dissecció aòrtica; Rigidesa aòrtica; Imatges per ressonància magnètica, Disección aórtica; Rigidez aórtica; Imágenes de resonancia magnética, Background Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. Methods Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. Results Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. Conclusions In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI17/00381 and PI20/01727), the Spanish Ministry of Science, Innovation and Universities (RTC2019-007280–1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015 and SEC/FEC-INV-CLI 21/030) and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Guala A. has received funding from Spanish Ministry of Science, Innovation and Universities (IJC2018-037349-I).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Versican accumulation drives Nos2 induction and aortic disease in Marfan syndrome via Akt activation

  • Ruiz-Rodriguez, Maria Jesus
  • Oller Pedrosa, Jorge
  • Martínez-Martínez, Sara
  • Alarcon Ruiz, Ivan
  • Toral, Marta
  • Sun, YiLin
  • Teixido-Tura, Gisela
Aortic aneurysm; Marfan syndrome; Versican, Aneurisma aòrtic; Síndrome de Marfan; Versican, Aneurisma aortico; Síndrome de Marfan; Versican, Thoracic aortic aneurysm and dissection (TAAD) is a life-threatening condition associated with Marfan syndrome (MFS), a disease caused by fibrillin-1 gene mutations. While various conditions causing TAAD exhibit aortic accumulation of the proteoglycans versican (Vcan) and aggrecan (Acan), it is unclear whether these ECM proteins are involved in aortic disease. Here, we find that Vcan, but not Acan, accumulated in Fbn1C1041G/+ aortas, a mouse model of MFS. Vcan haploinsufficiency protected MFS mice against aortic dilation, and its silencing reverted aortic disease by reducing Nos2 protein expression. Our results suggest that Acan is not an essential contributor to MFS aortopathy. We further demonstrate that Vcan triggers Akt activation and that pharmacological Akt pathway inhibition rapidly regresses aortic dilation and Nos2 expression in MFS mice. Analysis of aortic tissue from MFS human patients revealed accumulation of VCAN and elevated pAKT-S473 staining. Together, these findings reveal that Vcan plays a causative role in MFS aortic disease in vivo by inducing Nos2 via Akt activation and identify Akt signaling pathway components as candidate therapeutic targets., The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the Ministerio de Ciencia e Innovación (MCIN) and the Pro CNIC Foundation), the CBMSO is supported by Consejo Superior de Investigaciones Científicas and Universidad Autónoma de Madrid. CBMSO and CNIC are Severo Ochoa Centers of Excellence (grants CEX2021-001154-S and CEX2020-001041-S, respectively) funded by MICIN/AEI/10.13039/501100011033. The project leading to these results has received funding from “La Caixa” Banking Foundation under project codes HR18-00068 (to MRC and JMR); Spanish Ministerio de Ciencia e Innovación grant RTI2018-099246-B-I00 (MICIU/AEI/FEDER, UE) to JMR, and grants PID2020-115217RB-100 and PID2021-122388OB-100 to MRC and JMR, respectively, funded by MCIN/AEI/10.13039/501100011033; Instituto de Salud Carlos III (CIBER-CV CB16/11/00264 and CB16/11/00479; and grants PI17/00381 to GT-T and PI21/00084 (co-funded by Fondo Europeo de Desarrollo Regional (FEDER)) to JFN); Fundacio La Marato TV3 (20151330 to JMR); Instituto de Investigación Sanitaria Marqués de Valdecilla (IDIVAL) (INNVAL 21/24) to JFN; The Marfan Foundation USA Faculty grant 2017 MRF/1701 (to JMR); Fundación MERCK-Fundación Española de Enfermedades Raras 2022 and V-Ayudas “Muévete por los que no pueden 2021” (to JO); and Spanish Ministerio de Ciencia e Innovación contracts FPI (BES-2016-077649) to MJR-R; Sara Borrell (CD18/00028) and Juan de la Cierva (IJC2020-044581-I) to MT; Ramón y Cajal (RYC2021-033343-I) to JO; and FPU (20/04814) to IA-R.
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Impact of valve-sparing aortic root replacement on aortic fluid dynamics and biomechanics in patients with syndromic heritable thoracic aortic disease

  • Fernández Galera, Ruben
  • Ferrer Cornet, Marta
  • Bragulat Arévalo, Mireia
  • Carrasco-Poves, Alejandro
  • Ferreira González, Ignacio
  • Teixido-Tura, Gisela
  • Dux-Santoy Hurtado, Lydia
  • Ruiz Muñoz, Aroa
  • Guala, Andrea
  • Galian-Gay, Laura
  • Valente, Filipa
  • Casas, Guillem
  • Oliveró, Ruperto
  • Garrido-Oliver, Juan
  • Morales-Galan, Alberto
  • Evangelista Masip, Arturo
  • Rodríguez Palomares, José F
Fluid dynamics; Syndromic heritable thoracic aortic disease; Aortic root replacement, Dinàmica de fluids; Malaltia aòrtica toràcica hereditària sindròmica; Substitució de l'arrel aòrtica, Dinámica de fluidos; Enfermedad aórtica torácica hereditaria sindrómica; Reemplazo de la raíz aórtica, Background Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms remain unclear. This prospective, longitudinal study evaluates the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients. Methods Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two time-resolved three-dimensional phase-contrast cardiovascular magnetic resonance (4D flow CMR) studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two matched cohorts of 40 healthy volunteers (HV) and 16 sHTAD patients without indication for aortic root replacement (sHTAD-NSx) with available 4D flow CMR were included for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV), and aortic strain were analyzed in the ascending (AscAo) and descending aorta (DescAo). Results All patients with sHTAD presented altered hemodynamics and increased stiffness (p < 0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9 m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3 m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF −2.2 vs 10.4 cm2/s in HV, p = 0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p = 0.002), and decreased WSS (0.36 vs 0.47 N/m2 in HV, p = 0.004) in the proximal DescAo. After VSARR, proximal DescAo IRF (p = 0.010) and circumferential WSS increased (p = 0.011), no longer differing from HV, but SFRR, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3 cm2/s, p = 0.047). Most AscAo flow alterations were restored to physiological values after VSARR. Conclusion In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI17/00381, PI20/01727, and PI21/00448), the Spanish Ministry of Science, Innovation and Universities (FORT23/00034, RTC2019-007280-1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015, SEC/FEC-INV-CLI 21/030, and SEC/FEC-INV-CLI 23/08), and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Andrea Guala has received funding from “la Caixa” Foundation (LCF/BQ/PR22/11920008). Juan Garrido-Oliver has received funding from Secretaria d'Universitats i Recerca del Departament de Recerca i Universitats de la Generalitat de Catalunya i del Fons Europeu Social Plus (AGAUR-FI 2023 FI-1 00322 Joan Oró).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Aortic disease in Marfan syndrome is caused by overactivation of sGC-PRKG signaling by NO

  • de la Fuente-Alonso, Andrea
  • Alfayate, Alvaro
  • Ruiz-Rodríguez, María Jesús
  • Bonzón-Kulichenko, Elena
  • Teixido Tura, Gisela
  • Evangelista Masip, Artur
  • Toral, Marta
Aneurysm; Aortic diseases; Marfan syndrome, Aneurisma; Malalties aòrtiques; Síndrome de Marfan, Aneurisma; Enfermedades aórticas; Síndrome de Marfan, Thoracic aortic aneurysm, as occurs in Marfan syndrome, is generally asymptomatic until dissection or rupture, requiring surgical intervention as the only available treatment. Here, we show that nitric oxide (NO) signaling dysregulates actin cytoskeleton dynamics in Marfan Syndrome smooth muscle cells and that NO-donors induce Marfan-like aortopathy in wild-type mice, indicating that a marked increase in NO suffices to induce aortopathy. Levels of nitrated proteins are higher in plasma from Marfan patients and mice and in aortic tissue from Marfan mice than in control samples, indicating elevated circulating and tissue NO. Soluble guanylate cyclase and cGMP-dependent protein kinase are both activated in Marfan patients and mice and in wild-type mice treated with NO-donors, as shown by increased plasma cGMP and pVASP-S239 staining in aortic tissue. Marfan aortopathy in mice is reverted by pharmacological inhibition of soluble guanylate cyclase and cGMP-dependent protein kinase and lentiviral-mediated Prkg1 silencing. These findings identify potential biomarkers for monitoring Marfan Syndrome in patients and urge evaluation of cGMP-dependent protein kinase and soluble guanylate cyclase as therapeutic targets.