Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Targeted detection of Mycobacterium tuberculosis MPT64 antigen using an antibody-coated nanoporous anodic alumina biosensor: A novel approach for tuberculosis screening

  • Caballos, Isabel
  • Climent Terol, Estela
  • Gil-Brusola, Ana
  • Hernández-Montoto, Andy|||0000-0001-5623-9836
  • Martínez-Máñez, Ramón|||0000-0001-5873-9674
  • Aznar, Elena|||0000-0003-0361-3876
[EN] Tuberculosis (TB) is a chronic condition caused by Mycobacterium tuberculosis. According to WHO's Global Tuberculosis Report 2024, TB has again become the leading cause of death from a single infectious agent, surpassing COVID-19 in 2023 and 2024 in terms of infectious disease deaths. Due to its high infectivity and serious effects, timely diagnosis and treatment are crucial for controlling its spread. This study presents a fluorogenic biosensor for detecting M. tuberculosis MPT64 antigen using gated nanoporous anodic alumina (NAA). NAA material is loaded with rhodamine B and capped with an antibody against MPT64 protein. The presence of MPT64 induces antibody displacement due to the specific recognition and subsequent release of rhodamine B to the medium that is detected by fluorescence measurement. The biosensor is physicochemically characterized by scanning electron microscopy and X-ray spectroscopy. The biosensor achieves a limit of detection (LOD) of 1.32 nM (0.032 mg L-1) for MPT64 protein and demonstrated high selectivity through testing against various antigens from other viral pathogens and bacterial species. The efficacy of the biosensor is further validated with grown mycobacteria from clinical samples. The developed approach offers three key aspects: (i) selective detection of active TB by targeting the secreted MPT64 protein using gated nanomaterials; (ii) a rapid response (60 min); and (iii) a cost-effective design suitable for resource-limited settings. This biosensor shows great potential as a tool for the clinical diagnosis of active tuberculosis., We thank PID2024-155683OB-C41 and PID2021-126304OB-C41 from the Ministerio de Ciencia, Innovacion y Universidades and AEI/10.13039/501100011033 (co-financed by the European Regional Development Fund) , and CIPROM/2021/007 (to R. M.-M.) from the Generalitat Valenciana. This research was also supported by CIBER, Instituto de Salud Carlos III (group CB07/01/2012) . I.-C. thanks the Instituto de Salud Carlos III for her predoctoral fellowship (IFI21/00008) . We thank electron microscopy service of UPV for their support. R.M.M. thanks to the European Union's Horizon EUROPE research and innovation programme under grant agreement No 101093042. E. C. thanks the Instituto de Salud Carlos III for funding the proyects Miguel Servet 2023 CP23/00086 and PI24_01239, both co-funded by the European Union.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Anthracene-Modified Nanoporous Silica Nanoparticles for ATP Detection and Salivary Diagnostics in Parkinson&apos, s Disease

  • Ahi, E.E.
  • Climent Terol, Estela
  • Beyret, Cansu
  • Caglayan, Mehmet Gokhan
  • Coban, Burak
  • Yilmaz, Rezzak
  • Durmus, Mahmut
  • Martí-Centelles, Vicente|||0000-0002-9142-9392
  • Martínez-Máñez, Ramón|||0000-0001-5873-9674
[EN] ATP is an essential biological molecule, and abnormal levels are linked to various diseases. In this study, we developed an optical sensor array consisting of an anthracene-modified MCM-41 mesoporous nanoparticle-based hybrid organic-inorganic material to detect ATP in a TRIS-HCl buffer (pH 7). To create the sensor, we synthesized MCM-41 silica nanoparticles and functionalized them with aminoanthracene and imidazolium-anthracene groups. The fluorescence responses of the optical sensor array were recorded and analyzed by using a pattern recognition protocol, specifically linear discriminant analysis, to distinguish between ATP, ADP, AMP, and potential interferents. Quantitative regression analysis of ATP in TRIS-HCl was performed using artificial neural networks, which yielded an acceptable error rate of 7.8%. The sensor array was also evaluated for discrimination of Parkinson's disease (PD) from healthy controls, based on pattern recognition of ATP-related analytes in saliva samples from 24 patients with PD and 23 healthy controls. The results showed that the MCM-41 mesoporous silica nanoparticle-based sensor array can discriminate PD by pattern recognition with 73.7% sensitivity and 83.3% specificity., The diagnostic part of this study is supported by the Ankara University Scientific Research Projects Coordination Office (TSA-2023-2648 and TSA-2025-3825). V.M.-C. acknowledges financial support from the Project CIDEGENT/2020/031 funded by the Generalitat Valenciana, Project ESGENT/2024/ 001 funded by the Generalitat Valenciana, project PID2024- 157188OB-I00 funded by MICIU/AEI/10.13039/ 501100011033 and FEDER A way to make Europe, project PID2020-113256RA-I00 funded by MICIU/AEI/10.13039/ 501100011033, and project CNS2023-144879 funded by MICIU/AEI/10.13039/501100011033 and European Union NextGenerationEU/PRTR. R.M.-M. acknowledges the European Union s Horizon EUROPE research and innovation program under grant agreement no. 101093042, project PID2024-155683OB-C41 funded by MICIU/AEI/10.13039/ 501100011033 and FEDER A way to make Europe, project PID2021-126304OB-C41 funded by MICIU/AEI/10.13039/ 501100011033 and FEDER A way to make Europe, and project PROMETEO CIPROM/2021/007 funded by Generalitat Valenciana. E.C. thanks the Instituto de Salud Carlos III for founding the projects Miguel Servet 2023 CP23/00086 and PI24_01239, both cofunded by the European Union.