Skip to main content

MULTISCANNING-EMG DE UNA AGUJA: DESARROLLO DEL SISTEMA Y OBTENCION DE UNA BASE DE DATOS DE NORMALIDAD

PID2019-109062RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACIÓN INSTITUTO DE INVESTIGACIÓN SANITARIA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

EMG probability density function: a new way to look at EMG signal filling from single motor unit potential to full interference pattern

  • Navallas Irujo, Javier
  • Eciolaza Ferrando, Adrián
  • Mariscal Aguilar, Cristina
  • Malanda Trigueros, Armando
  • Rodríguez Falces, Javier
An analytical derivation of the EMG signal's amplitude probability density function (EMG PDF) is presented and used to study how an EMG signal builds-up, or fills, as the degree of muscle contraction increases. The EMG PDF is found to change from a semi-degenerate distribution to a Laplacian-like distribution and finally to a Gaussian-like distribution. We present a measure, the EMG filling factor, to quantify the degree to which an EMG signal has been built-up. This factor is calculated from the ratio of two non-central moments of the rectified EMG signal. The curve of the EMG filling factor as a function of the mean rectified amplitude shows a progressive and mostly linear increase during early recruitment, and saturation is observed when the EMG signal distribution becomes approximately Gaussian. Having presented the analytical tools used to derive the EMG PDF, we demonstrate the usefulness of the EMG filling factor and curve in studies with both simulated signals and real signals obtained from the tibialis anterior muscle of 10 subjects. Both simulated and real EMG filling curves start within the 0.2 to 0.35 range and rapidly rise towards 0.5 (Laplacian) before stabilizing at around 0.637 (Gaussian). Filling curves for the real signals consistently followed this pattern (100% repeatability within trials in 100% of the subjects). The theory of EMG signal filling derived in this work provides (a) an analytically consistent derivation of the EMG PDF as a function of motor unit potentials and motor unit firing patterns; (b) an explanation of the change in the EMG PDF according to degree of muscle contraction; and (c) a way (the EMG filling factor) to quantify the degree to which an EMG signal has been built-up., This work was supported by the Ministerio de Ciencia e Innovacion of the Spanish Government under Grant PID2019-109062RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

M-wave changes caused by brief voluntary and stimulated isometric contractions

  • Rodríguez Falces, Javier
  • Malanda Trigueros, Armando
  • Navallas Irujo, Javier
  • Place, Nicolas
Introduction Under isometric conditions, the increase in muscle force is accompanied by a reduction in the fbers’ length. The efects of muscle shortening on the compound muscle action potential (M wave) have so far been investigated only by computer simulation. This study was undertaken to assess experimentally the M-wave changes caused by brief voluntary and stimulated isometric contractions. Methods Two diferent methods of inducing muscle shortening under isometric condition were adopted: (1) applying a brief (1 s) tetanic contraction and (2) performing brief voluntary contractions of diferent intensities. In both methods, supramaximal stimulation was applied to the brachial plexus and femoral nerves to evoke M waves. In the frst method, electrical stimulation (20 Hz) was delivered with the muscle at rest, whereas in the second, stimulation was applied while participants performed 5-s stepwise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 100% MVC. The amplitude and duration of the frst and second M-wave phases were computed. Results The main fndings were: (1) on application of tetanic stimulation, the amplitude of the M-wave frst phase decreased (~10%, P<0.05), that of the second phase increased (~50%, P<0.05), and the M-wave duration decreased (~20%, P<0.05) across the frst fve M waves of the tetanic train and then plateaued for the subsequent responses; (2) when superimposing a single electrical stimulus on muscle contractions of increasing forces, the amplitude of the M-wave frst phase decreased (~20%, P<0.05), that of the second phase increased (~30%, P<0.05), and M-wave duration decreased (~30%, P<0.05) as force was raised from 0 to 60–70% MVC force. Conclusions The present results will help to identify the adjustments in the M-wave profle caused by muscle shortening and also contribute to diferentiate these adjustments from those caused by muscle fatigue and/or changes in Na+–K+ pump activity., Open Access funding provided by Universidad Pública de Navarra. This work has been supported by the Spanish Ministry of Science and Innovation under the project PID2019-109062RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Effects of muscle shortening on single-fiber, motor unit, and compound muscle action potentials

  • Rodríguez Falces, Javier
  • Malanda Trigueros, Armando
  • Navallas Irujo, Javier
Even under isometric conditions, muscle contractions are associated with some degree of fiber shortening. The effects of muscle shortening on extracellular electromyographic potentials have not been characterized in detail. Moreover, the anatomical, biophysical, and detection factors influencing the muscle-shortening effects have been neither identified nor understood completely. Herein, we investigated the effects of muscle shortening on the amplitude and duration characteristics of singlefiber, motor unit, and compound muscle action potentials. We found that, at the single-fiber level, two main factors influenced the muscle-shortening effects: (1) the electrode position and distance relative to the myotendinous zone and (2) the electrode distance to the maxima of the dipole field arising from the stationary dipole created at the fiber-tendon junction. Besides, at the motor unit and muscle level, two additional factors were involved: (3) the overlapping between the propagating component of some fibers with the non-propagating component of other fibers and (4) the spatial spreading of the fiber-tendon junctions. The muscle-shortening effects depend critically on the electrode longitudinal distance to the myotendinous zone. When the electrode was placed far from the myotendinous zone, muscle shortening resulted in an enlargement and narrowing of the final (negative) phase of the potential, and this enlargement became less pronounced as the electrode approached the fiber endings. For electrode locations close to the myotendinous zone, muscle shortening caused a depression of both the main (positive) and final (negative) phases of the potential. Beyond the myotendinous zone, muscle shortening led to a decrease of the final (positive) phase. The present results provide reference information that will help to identify changes in MUPs and M waves due to muscle shortening, and thus to differentiate these changes from those caused by muscle fatigue., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been supported by the Spanish Ministry of Science and Innovation under the project PID2019-109062RB-I00
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Masked least-squares averaging in processing of scanning-EMG recordings with multiple-discharges

  • Corera Orzanco, Íñigo
  • Malanda Trigueros, Armando
  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
Removing artifacts from nearby motor units is one of the main objectives when processing scanning-EMG recordings. Methods such as median filtering or masked least-squares smoothing (MLSS) can be used to eliminate artifacts in recordings with just one discharge of the motor unit potential (MUP) at each location. However, more effective artifact removal can be achieved if several discharges per position are recorded. In this case, processing usually involves averaging the discharges available at each position and then applying a median filter in the spatial dimension. The main drawback of this approach is that the median filter tends to distort the signal waveform. In this paper, we present a new algorithm that operates on multiple discharges simultaneously and in the spatial dimension. We refer to this algorithm as the multi masked least-squares smoothing (MMLSS) algorithm: an extension of the MLSS algorithm for the case of multiple discharges. The algorithm is tested using simulated scanning-EMG signals in different recording conditions, i.e., at different levels of muscle contraction and for different numbers of discharges per position. Results demonstrate that the algorithm eliminates artifacts more effectively than any previously available method and does so without distorting the waveform of the signal., This work has been supported by the Spanish Ministry of Science and Innovation under the project PID2019-109062RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Automatic detection of motor unit fractions in multiscanning EMG recordings

  • Kallingal Muraleedharan, Mahima
  • Mariscal Aguilar, Cristina
  • Rodríguez Falces, Javier
  • Navallas Irujo, Javier
  • Malanda Trigueros, Armando
Purpose This study presents a novel algorithm for the automatic detection of motor unit (MU) fractions within the motor unit potential (MUP) scans derived from multiscanning EMG recordings. MU fractions are spatially distinct regions identif ied in the MUP scans that reflect the distribution of muscle fibres within each MU. Multiscanning EMG allows recording multiple MUPs simultaneously in a single recording, improving efficiency and reducing patient discomfort. Methods The algorithm combines amplitude thresholding, morphological operations, and connected component analysis to identify MU fractions. Algorithm performance was evaluated using MUP scans from tibialis anterior muscles of five healthy individuals. The analysis was performed in two ways: the first included all the fractions detected automatically, and the second included only those fractions detected in both the automatic and the ground truth. Additionally, the association between muscle depth, number of MU fractions, and signal-to-noise ratio (SNR) of the recorded signals was analysed. Results T-tests showed no statistically significant difference between the algorithm and ground truth for both start and end markers. ANOVA indicated that muscle depth did not affect the signal-to-noise ratio (f = 1.06, p = 0.35). Overall, the algorithm reliably identified MU fractions. Conclusion The proposed automatic method accurately detects MU fractions, providing a valuable tool for analysing motor unit activity in clinical and research settings., This work was supported by the predoctoral grant from the Department of Universities, Innovation and Digital Transformation, Govt. of Navarra (Grant number: 0011-0537-2021-000059). This work was also supported by the Ministerio de Ciencia e Innovacion, Spanish Government (Grant number: PID2019-109062RB-100, PID2022-1366200B-100). Ministerio de Ciencia e Innovación, PID2019-109062RB-100, Javier Navallas, Spanish National Plan for Scientific and Technical Research and Innovation, PID2022-136620OB-I00, Javier Navallas, Departamento de Universidad, Innovación y Transformación Digital - Gobierno de Navarra., 0011-0537-2021-000059, Mahima Kallingal Muraleedharan.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Automatic jitter measurement in needle-detected motor unit potential trains

  • Malanda Trigueros, Armando
  • Stashuk, Daniel W.
  • Navallas Irujo, Javier
  • Rodríguez Falces, Javier
  • Rodríguez Carreño, Ignacio
  • Valle, César
  • Garnés Camarena, Óscar
In an active motor unit (MU), the time intervals between the firings of its muscle fibers vary across successive MU activations. This variability is called jitter and is increased in pathological processes that affect the neuromuscular junctions or terminal axonal segments of MUs. Traditionally, jitter has been measured using single fiber electrodes (SFEs) and a difficult and subjective manual technique. SFEs are expensive and reused, implying a potential risk of patient infection; so, they are being gradually substituted by safer, disposable, concentric needle electrodes (CNEs). As CNEs are larger, voltage contributions from individual fibers of a MU are more difficult to detect, making jitter measurement more difficult. This paper presents an automatic method to estimate jitter from trains of motor unit potentials (MUPs), for both SFE and CNE records. For a MUP train, segments of MUPs generated by single muscle fibers (SF MUP segments) are found and jitter is measured between pairs of these segments. Segments whose estimated jitter values are not reliable, according to several SF MUP segment characteristics, are excluded. The method has been tested in several simulation studies that use mathematical models of muscle fiber potentials. The results are very satisfactory in terms of jitter estimation error (less than 10% in most of the cases studied) and mean number of valid jitter estimates obtained per simulated train (greater than 1.0 in many of the cases and less than 0.5 only in the most complicated). A preliminary study with real signals was also performed, using 19 MUP trains from 3 neuropathic patients. Jitter measurements obtained by the automatic method were compared with those extracted from a commercial system (Keypoint) and the edition and supervision of an expert electromyographer. From these measurements 63% were taken from equivalent interval pair sites within the time span of the MUP trains and, as such, were considered as compatible measurements. Differences in jitter of these compatible measurements were very low (mean value of 1.3 μs, mean of absolute differences of 2.97 μs, 25% and 75% percentile intervals of − 0.85 and 3.82 μs, respectively). Although new tests with larger number of real recordings are still required, the method seems promising for clinical practice., This work has been supported by the Spanish Ministry of Science, Education, and Universities, under the “Salvador de Madariaga” 2018 Program and by the Spanish Ministry of Education and Research, under the PID2019-109062RB-I00 project. Open Access funding provided by the Public University of Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Sarcolemmal excitability, M-Wave changes, and conduction velocity during a sustained low-force contraction

  • Rodríguez Falces, Javier
  • Place, Nicolas
This study was undertaken to investigate whether sarcolemmal excitability is impaired during a sustained low-force contraction [10% maximal voluntary contraction (MVC)] by assessing muscle conduction velocity and also by analyzing separately the first and second phases of the muscle compound action potential (M wave). Twenty-one participants sustained an isometric knee extension of 10% MVC for 3min. M waves were evoked by supramaximal single shocks to the femoral nerve given at 10-s intervals. The amplitude, duration, and area of the first and second M-wave phases were computed. Muscle fiber conduction velocity, voluntary surface electromyographic (EMG), perceived effort, MVC force, peak twitch force, and temperature were also recorded. The main findings were: (1) during the sustained contraction, conduction velocity remained unchanged. (2) The amplitude of the M-wave first phase decreased for the first ~30s (−7%, p<0.05) and stabilized thereafter, whereas the second phase amplitude increased for the initial ~30s (+7%, p<0.05), before stabilizing. (3) Both duration and area decreased steeply during the first ~30s, and then more gradually for the rest of the contraction. (4) During the sustained contraction, perceived effort increased fivefold, whereas knee extension EMG increased by ~10%. (5) Maximal voluntary force and peak twitch force decreased (respectively, −9% and −10%, p<0.05) after the low-force contraction. Collectively, the present results indicate that sarcolemmal excitability is well preserved during a sustained 10% MVC task. A depression of the M-wave first phase during a low-force contraction can occur even in the absence of changes in membrane excitability. The development of fatigue during a low-force contraction can occur without alteration of membrane excitability., This work has been supported by the Spanish Ministry of Science and Innovation under the project PID2019-109062RB-I00.