Skip to main content

CUANTIFICACION DEL DETERIORO LOCAL DEL MIOCARDIO MEDIANTE CATETER MULTIELECTRODO GRID ALTA DENSIDAD. IDENTIFICACION D METRICAS DEL SUSTRATO FIBROTICO RESPONSABLE DE ARRITMIAS.

PID2019-109547RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2019
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation and assessment of clique arrangements for the estimation of omnipolar electrograms in high density electrode arrays: an experimental animal model study

  • Ruiperez-Campillo, Samuel
  • Crespo, Marina
  • Alberola, Antonio
  • Heimer, Jakob
  • Chorro, Francisco J.
  • Tormos Ferrando, Álvaro|||0000-0002-3280-376X
  • Guill Ibáñez, Antonio|||0000-0001-8546-264X
  • Cebrián Ferriols, Antonio José|||0000-0003-0519-5284
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated oEGMs according to the classic triangular clique (4 possible orientations) and a novel cross-orientation clique arrangement. Furthermore, we tested the effects of interelectrode spacing from 1 to 4 mm. Performance was evaluated by means of several parameters that measured amplitude rejection ratios, electric field loop area, activation pulse width and morphology distortion. Most reliable oEGM estimations were obtained with cross-configurations and interelectrode spacings = 2 mm. Estimations from triangular cliques resulted in wider electric field loops and unreliable detection of the direction of the propagation wavefront. Moreover, increasing interelectrode distance resulted in increased pulse width and morphology distortion. The results prove that current oEGM estimation techniques are insufficiently accurate. This study opens a new standpoint for the design of new-generation HD catheters and mapping software., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by PID2019- 109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovación, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance assessment of electrode configurations for the estimation of omnipolar electrograms from high density arrays

  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
  • Ruiperez-Campillo, Samuel
  • Segarra, Izan
  • Cervigon, Raquel
  • Casado-Arroyo, Rubén
  • Merino, José Luis
[EN] Objective: The aim of this study is to propose a method to reduce the sensitivity of the estimated omnipolar electrogram (oEGM) with respect to the angle of the propagation wavefront. Methods: A novel configuration of cliques taking into account all four electrodes of a squared cell is proposed. To test this approach, simulations of HD grids of cardiac activations at different propagation angles, conduction velocities, interelectrode distance and electrogram waveforms are considered. Results: The proposed approach successfully provided narrower loops (essentially a straight line) of the electrical field described by the bipole pair with respect to the conventional approach. Estimation of the direction of propagation was improved. Additionally, estimated oEGMs presented larger amplitude, and estimations of the local activation times were more accurate. Conclusions: A novel method to improve the estimation of oEGMs in HD grid of electrodes is proposed. This approach is superior to the existing methods and avoids pitfalls not yet resolved., This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) and CIacBERCV CB16/11/00486 (Instituto de Salud Carlos III). We would like express our gratitute to the Rafael del Pino Foundation and La Caixa Foundation for the support and contribution to the academic training of one first author of the manuscript (S. Ruiperez-Campillo).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

From 12 to 1 ECG lead: multiple cardiac condition detection mixing a hybrid machine learning approach with a one-vs-rest classification strategy

  • Jiménez-Serrano, Santiago|||0000-0003-2917-6053
  • Calvo Saiz, Conrado Javier
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
  • Rodrigo, Miguel
[EN] Objective: Detecting different cardiac diseases using a single or reduced number of leads is still challenging. This work aims to provide and validate an automated method able to classify ECG recordings. Performance using complete 12-lead systems, reduced lead sets, and single-lead ECGs is evaluated and compared. Approach: Seven different databases with 12-lead ECGs were provided during the PhysioNet/Computing in Cardiology Challenge 2021, where 88,253 annotated samples associated with none, one, or several cardiac conditions among 26 different classes were released for training, whereas 42,896 hidden samples were used for testing. After signal preprocessing, 81 features per ECG-lead were extracted, mainly based on heart rate variability, QRST patterns and spectral domain. Next, a One-vs-Rest classification approach made of independent binary classifiers for each cardiac condition was trained. This strategy allowed each ECG to be classified as belonging to none, one or several classes. For each class, a classification model among two binary Supervised Classifiers and one Hybrid Unsupervised-Supervised classification system was selected. Finally, we performed a 3-fold cross-validation to assess the system's performance. Main results: Our classifiers received scores of 0.39, 0.38, 0.39, 0.38, and 0.37 for the 12, 6, 4, 3 and 2-lead versions of the hidden test set with the Challenge evaluation metric (CM). Also, we obtained a mean G-score of 0.80, 0.78, 0.79, 0.79, 0.77 and 0.74 for the 12, 6, 4, 3, 2 and 1-lead subsets with the public training set during our 3-fold cross-validation. Significance: We proposed and tested a machine learning approach focused on flexibility for identifying multiple cardiac conditions using one or more ECG leads. Our minimal-lead approach may be beneficial for novel portable or wearable ECG devices used as screening tools, as it can also detect multiple and concurrent cardiac conditions., This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovación, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Non-invasive characterisation of macroreentrant atrial tachycardia types from a vectorcardiographic approach with the slow conduction region as a cornerstone

  • Ruipérez-Campillo, Samuel
  • Castrejón, Sergio
  • Martínez, Marcel
  • Cervigón, Raquel
  • Meste, Olivier
  • Merino, José Luis
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] Background and objectives: Macroreentrant atrial tachyarrhythmias (MRATs) can be caused by different reentrant circuits. The treatment for each MRAT type may require ablation at different sites, either at the right or left atria. Unfortunately, the reentrant circuit that drives the arrhythmia cannot be ascertained previous to the electrophysiological intervention. Methods: A noninvasive approach based on the comparison of atrial vectorcardiogram (VCG) loops is proposed. An archetype for each group was created, which served as a reference to measure the similarity between loops. Methods were tested in a variety of simulations and real data obtained from the most common right (peritricuspid) and left (perimitral) macroreentrant circuits, each divided into clockwise and counterclockwise subgroups. Adenosine was administered to patients to induce transient AV block, allowing the recording of the atrial signal without the interference of ventricular signals. From the vectorcardiogram, we measured intrapatient loop consistence, similarity of the pathway to archetypes, characterisation of slow velocity regions and pathway complexity. Results: Results show a considerably higher similarity with the loop of its corresponding archetype, in both simulations and real data. We found the capacity of the vectorcardiogram to reflect a slow velocity region, consistent with the mechanisms of MRAT, and the role that it plays in the characterisation of the reentrant circuit. The intra-patient loop consistence was over 0.85 for all clinical cases while the similarity of the pathway to archetypes was found to be 0.85 +/- 0.03, 0.95 +/- 0.03, 0.87 +/- 0.04 and 0.91 +/- 0.02 for the different MRAT types (and p < 0 . 02 for 3 of the 4 groups), and pathway complexity also allowed to discriminate among cases (with p < 0 . 05 ). Conclusions: We conclude that the presented methodology allows us to differentiate between the most common forms of right and left MRATs and predict the existence and location of a slow conduction zone. This approach may be useful in planning ablation procedures in advance., This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government), CIBERCV CB16/11/00486 (Instituto de Salud Carlos III) and PROMETEOII/2014/037 (Generalitat Valenciana).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Vector Field Heterogeneity for the Assessment of Locally Disorganised Cardiac Electrical Propagation Wavefronts From High-Density Multielectrodes

  • Pancorbo, Lucía
  • Ruiperez-Campillo, Samuel
  • Tormos, Álvaro
  • Cervigón, Raquel
  • Alberola, Antonio
  • Chorro, Francisco Javier
  • Guill Ibáñez, Antonio|||0000-0001-8546-264X
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] High-density multielectrode catheters are becoming increasingly popular in cardiac electrophysiology for advanced characterisation of the cardiac tissue, due to their potential to identify impaired sites. These are often characterised by abnormal electrical conduction, which may cause locally disorganised propagation wavefronts. To quantify it, a novel heterogeneity parameter based on vector field analysis is proposed, utilising finite differences to measure direction changes between adjacent cliques. The proposed Vector Field Heterogeneity metric has been evaluated on a set of simulations with controlled levels of organisation in vector maps, and a variety of grid sizes. Furthermore, it has been tested on animal experimental models of isolated Langendorff-perfused rabbit hearts. The proposed parameter exhibited superior capturing ability of heterogeneous propagation wavefronts compared to the classical Spatial Inhomogeneity Index, and simulations proved that the metric effectively captures gradual increments in disorganisation in propagation patterns. Notably, it yielded robust and consistent outcomes for $\mathbf {4\times 4}$ grid sizes, underscoring its suitability for the latest generation of orientation-independent cardiac catheters., This work was supported in part by the National Research Program, Ministerio de Ciencia e Innovación, Spanish Government under Grants PID2019- 109547RB-I00 and PID2022-142514OB-I00, and in part by Instituto de Salud Carlos II under Grant CIBERCV CB16/11/00486.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Clustering and machine learning framework for medical time series classification

  • Ruiperez-Campillo, Samuel
  • Reiss, Michael
  • Elisa
  • Cebrián Ferriols, Antonio José|||0000-0003-0519-5284
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] Background and motivation: The application of artificial intelligence in medical research, particularly unsupervised learning techniques, has shown promising potential. Medical time series data poses a unique challenge for analysis due to its complexity. Existing unsupervised learning methods often fail to effectively classify these variations, highlighting a gap in current approaches. We introduce a methodological clustering classification framework designed to accurately handle such data, aiming for improved classification tasks in biomedical signals. Methods: To address these challenges, we introduce a novel approach for the analysis and classification of medical time series data. Our method integrates agglomerative hierarchical clustering with Hilbert vector space representations of medical signals and biological sequences. We rigorously define the mathematical principles and conduct evaluations using simulations of cardiac signals, real-world neural signal datasets, open-source protein sequences, and the MNIST dataset for illustrative purposes. Results: The proposed method exhibited a 96% success rate in classifying protein sequences by function and effectively identifying families within a large protein set. In cardiac signal analysis, it retained 0.996 variance in a condensed 6-dimensional space, accurately classifying 87.4% of simulated atrial flutter groups and 99.91% of main groups when excluding conduction direction. For neural signals, it demonstrated near-perfect tracking accuracy of neural activity in mouse brain recordings, as confirmed by expert evaluations. Conclusion: Our proposed method offers a novel, translational approach for the treatment and classification of medical and biological time series, addressing some of the prevalent challenges in the field and paving the way for more reliable and effective biomedical signal analysis., This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovación, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Pulmonary Vein Activity Organization to Determine Atrial Fibrillation Recurrence: Preliminary Data from a Pilot Study

  • Cervigón, Raquel
  • Moreno, Javier
  • Pérez-Villacastín, Julián
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] Ablation of pulmonary veins has emerged as a key procedure for normal rhythm restoration in atrial fibrillation patients. However, up to half of ablated Atrial fibrillation (AF) patients suffer recurrences during the first year. In this article, simultaneous intra-atrial recordings registered at pulmonary veins previous to the ablation procedure were analyzed. Spatial cross-correlation and transfer entropy were computed in order to estimate spatial organization. Results showed that, in patients with arrhythmia recurrence, pulmonary vein electrical activity was less correlated than in patients that maintained sinus rhythm. Moreover, correlation function between dipoles showed higher delays in patients with AF recurrence. Results with transfer entropy were consistent with spatial cross-correlation measurements. These results show that arrhythmia drivers located at the pulmonary veins are associated with a higher organization of the electrical activations after the ablation of these sites., This research was funded by Spanish Ministry of Research and Innovation : PID2019-109547RB-I00. This research was supported by the PID2019-109547RB-I00 National Research Program RETOS from the Spanish Ministry of Research and Innovation and partialy by GVA (PROMETEO/2018/078) & ISCIII (CB16/11/00486). Thanks to Michael Charles Willoughby for English language and scientific editing services.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A new method for manufacturing dry electrodes on textiles. Validation for wearable ECG monitoring

  • FERRI PASCUAL, JOSUÉ|||0000-0002-8084-6182
  • Llinares Llopis, Raúl|||0000-0002-9732-2262
  • Cebrián Ferriols, Antonio José|||0000-0003-0519-5284
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
  • Millet Roig, José|||0000-0002-8879-003X
  • Segarra, Izan
[EN] This paper presents a new dry ECG electrode printed on a textile substrate. The proposed manufacturing process permits cost-effective mass production. The ECG dry electrode is obtained through screen printing a conductive silver ink coated with a biocompatible carbon layer. Three different designs combining two shapes (circular and square) and two sizes were developed. The resulting measured impedances are similar to those obtained via a conventional electrode. The prototypes were attached to a bracelet and used with a commercial electrocardiogram (ECG) device to register ECG signals. The dry electrodes were validated via ECG monitoring and compared with a conventional wet electrode. The clinical interest intervals reported similar results and the QRS morphology presented slight differences. Noise evaluation showed no notable differences for all the analyzed parameters., The work presented was funded by the Conselleria d'Economia Sostenible, Sectors Productius i Treball, through IVACE. HYBRID II Project, IMAMCI/2021/1. This work was also supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) & CIBERCV CB16/11/00486 (Instituto de Salud Carlos III)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Multiple Cardiac Disease Detection from Minimal-Lead ECG Combining Feedforward Neural Networks with a One-vs-Rest Approach

  • Jiménez-Serrano, Santiago|||0000-0003-2917-6053
  • Calvo Saiz, Conrado Javier
  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
  • RODRIGO BORT, MIGUEL
[EN] Although standard 12-lead ECG is the primary technique in cardiac diagnostic, detecting different cardiac diseases using single or reduced number of leads is still challenging. The purpose of our team, itaca-UPV, is to provide a method able to classify ECG records using minimal lead information in the context of the 2021 PhysioNet/Computing in Cardiology Challenge, also using only a single-lead. We resampled and filtered the ECG signals, and extracted 109 features mostly based on Hearth Rhythm Variability (HRV). Then, we used selected features to train one feed-forward neural network (FFNN) with one hidden layer for each class using a One-vs-Rest approach, thus allowing each ECG to be classified as belonging to none or more than one class. Finally, we performed a 3-fold cross validation to assess the model performance. Our classifiers received scores of 0.34, 0.34, 0.27, 0.30, and 0.34 (ranked 26th, 21th, 29th, 25th, and 22th out of 39 teams) for the 12, 6, 4, 3 and 2-lead versions of the hidden test set with the Challenge evaluation metric. Our minimal-lead approach may be beneficial for novel portable or wearable ECG devices used as screening tools, as it can also detect multiple and concurrent cardiac conditions. Accuracy in detection can be improved adding more disease-specific features.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Mini Peltier Cell Array System for the Generation of Controlled Local Epicardial Heterogeneities

  • Segarra, Izan
  • Ruiperez-Campillo, Samuel
  • Chorro, Francisco Javier
  • Alberola, Antonio
  • Cebrián Ferriols, Antonio José|||0000-0003-0519-5284
  • Tormos Ferrando, Álvaro|||0000-0002-3280-376X
  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
[EN] The present study aims to design and fabricate a system capable of generating heterogeneities on the epicardial surface of an isolated rabbit heart perfused in a Langendorff system. The system consists of thermoelectric modules that can be independently controlled by the developed hardware, thereby allowing for the generation of temperature gradients on the epicardial surface, resulting in conduction slowing akin to heterogeneities of pathological origin. A comprehensive analysis of the system's viability was performed through modeling and thermal simulation, and its practicality was validated through preliminary tests conducted at the experimental cardiac electrophysiology laboratory of the University of Valencia. The design process involved the use of Fusion 360 for 3D designs, MATLAB/Simulink for algorithms and block diagrams, LTSpice and Altium Designer for schematic captures and PCB design, and the integration of specialized equipment for animal experimentation. The objective of the study was to efficiently capture epicardial recordings under varying conditions.Clinical relevance- The proposed system aims to induce local epicardial heterogeneities to generate labeled correct signals that can serve as a golden standard for improving algorithms that identify and characterize fibrotic substrates. This improvement will enhance the efficacy of ablation processes and potentially reduce the ablated surface area., This work was supported by PID2019-109547RB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Estimation of PQ distance dispersion for atrial fibrillation detection

  • Giraldo-Guzmán, Jader
  • Kotas, Marian
  • Contreras-Ortiz, Sonia H.
  • Urina-Triana, Miguel
  • Castells, Francisco|||0000-0001-5044-3545
[EN] Background and objective: Atrial fibrillation (AF) is the most common cardiac arrhythmia in the world. It is associated with significantly increased morbidity and mortality. Diagnosis of the disease can be based on the analysis of the electrical atrial activity, on quantification of the heart rate irregularity or on a mixture of the both approaches. Since the amplitude of the atrial waves is small, their analysis can lead to false results. On the other hand, the heart rate based analysis usually leads to many unnecessary warnings. Therefore, our goal is to develop a new method for effective AF detection based on the analysis of the electrical atrial waves. Methods: The proposed method employs the fact that there is a lack of repeatable P waves preceding QRS complexes during AF. We apply the operation of spatio-temporal filtering (STF) to magnify and detect the prominent spatio-temporal patterns (STP) within the P waves in multi-channel ECG recordings. Later we measure their distances (PQ) to the succeeding QRS complexes, and we estimate dispersion of the obtained PQ series. For signals with normal sinus rhythm, this dispersion is usually very low, and contrary, for AF it is much raised. This allows for effective discrimination of this cardiologic disorder. Results: Tested on an ECG database consisting of AF cases, normal rhythm cases and cases with normal rhythm restored by the use of cardioversion, the method proposed allowed for AF detection with the accuracy of 98 . 75% on the basis of both 8-channel and 2-channel signals of 12 s length. When the signals length was decreased to 6 s, the accuracy varied in the range of 95% - 97 . 5% depending on the number of channels and the dispersion measure applied. Conclusions: Our approach allows for high accuracy of atrial fibrillation detection using the analysis of electrical atrial activity. The method can be applied to an early detection of the desease and can advantageously be used to decrease the number of false warnings in systems based on the analysis of the heart rate., The authors report no conflicts of interest. The authors alone are responsible for the content and writing of this article. This research is partially supported by statutory funds of the Depart-ment of Cybernetics, Nanotechnology and Data Processing, Sile-sian University of Technology, BK2021. Francisco Castells receives research funds from the National Research Program RETOS under grant PID2019-109547RB-I0 0 from the Ministry of Science, Spanish Government. Jader Giraldo received funds from Universidad Tecnologica de Bolivar, CartagenaColombia, (grantcode: C2018P022) . The work was performed using the infrastructure supported by POIG.02.03.0124099/13 grant: GeCONiI-Upper Silesian Center for Computational Science and Engineering.