ESTRATEGIAS DE VENTILACION OPTIMIZADAS CONSIDERANDO LA CALIDAD DEL AIRE INTERIOR, EL CONFORT TERMICO Y EL CONSUMO DE ENERGIA EN EDIFICIOS EDUCATIVOS

PID2020-117366RB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2020
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 53
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Energy implications of meeting indoor air quality and thermal comfort standards in Mediterranean schools using natural and mechanical ventilation strategies

  • Maiques Garcia, Maria|||0009-0005-6506-1589
  • Tarragona Roig, Joan|||0000-0001-6776-4273
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Casals Casanova, Miquel|||0000-0001-5379-894X
Educational buildings often face significant challenges with indoor air quality and thermal comfort, mainly due to a lack of mechanical ventilation and air conditioning systems. Research has demonstrated that these issues negatively affect students’ learning. The main objective of this paper was to assess compliance with indoor air quality and thermal comfort standards in educational buildings, by quantifying HVAC energy implications under natural and mechanical ventilation strategies. For this purpose, an educational building model that has 4 classrooms occupied by students from different age groups was simulated in 11 Mediterranean climate zones, for 4 ventilation strategies, and with 2 building orientations. The results reveal that natural ventilation is effective only in mild Mediterranean climates, with air quality non-compliance ranging from 0 % to 2 % and thermal comfort non-compliance between 2 % and 5 %. As expected, mechanical ventilation always ensures acceptable indoor air quality and thermal comfort. It achieves average HVAC energy savings of 80 % compared to natural ventilation. When considering that students’ CO2 generation rates vary depending on the age, systems with CO2 sensors further reduce HVAC demand (8 %), while maintaining comfort levels. Building orientation was found to have a significant impact for naturally ventilated buildings. South-facing orientations can reduce HVAC energy demand by up to 42 % (1,989 kWh/m2·year), whereas mechanically ventilated buildings show minimal sensitivity to orientation (up to 36 kWh/m2·year). This research will help public authorities of the educational community and architecture and engineering sectors when they are planning, designing and retrofitting educational buildings. Educational building managers will also benefit from this research by being able to optimise building ventilation through the effective management of existing resources., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. Maria Maiques gratefully acknowledges the Universitat Politècnica de Catalunya for the financial support of her predoctoral grant FPU-UPC 2023 Complementària, with the collaboration of Banco de Santander. This study was also supported by the Catalan Agency AGAUR under their research group support programme (2021 SGR 00341), Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A simplified classroom indoor air quality risk index: application in the Mediterranean Region to support the enhanced design of educational environments

  • López Carreño, Rubén-Daniel|||0000-0003-1040-5135
  • Pardo Bosch, Francesc|||0000-0001-9532-8508
  • Aidarov, Stanislav|||0000-0001-5576-7215
  • Boix Cots, David|||0000-0002-8462-8887
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
The quality of indoor environments within educational settings significantly impacts the health, safety, and comfort of occupants. In this manuscript, a simplified Classroom Indoor Air Quality (CIAQ) Risk Index, aimed at assessing the potential ability of classrooms to maintain CO2 levels within acceptable limits, is introduced. Comprising three primary components—the likelihood of surpassing predefined CO2 thresholds, the potential number of individuals exposed, and the classroom’s capacity to withstand or mitigate threats—this index serves as a valuable compliance tool during both the design phase and operational management of educational spaces. Additionally, apart from presenting the index framework, a sensitivity case study analysis is carried out to verify the suitability of the proposed method and the sensitivity of the factors involved. Through this analysis, the robustness of the CIAQ Risk Index in various scenarios is demonstrated. By quantifying and evaluating potential risks associated with indoor air quality, the CIAQ Risk Index contributes to ongoing efforts to create healthier indoor environments. Furthermore, it facilitates the identification of budgetary mitigation strategies that should positively affect the air quality; among those, an intervention, retrofitting, and ventilation improvements can be listed. Through proactive risk identification and appropriate actions, including regulation adjustments and ventilation strategies, the reduction in health problems, the enhancement of well-being, and the improvement of overall performance and quality of life for educational communities can be achieved., This study is conducted as part of the R&D project IAQ4EDU (reference no. PID2020117366RB-I00), funded by MCIN/AEI/10.13039/501100011033. P.P. and F.P. acknowledge the support provided by the Serra Húnter program. Additionally, this work has received funding from the Agència de Gestió d’Ajuts Universitaris i de Recerca (AGAUR) under the research group support program (2021 SGR 00341)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Validating single-sided natural ventilation models for educational buildings

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
To maintain good indoor air quality in schools, it is often necessary to apply single-sided natural ventilation models using urban weather stations, since the local weather station is not available for most schools. However, the field study that validated the ventilation models with full-scale experiments in classrooms is very limited. Therefore, this study validated 6 existing single-sided ventilation models based on two field measurement campaigns conducted in naturally ventilated educational buildings, including the Warren & Parkins (1977 & 1985), De Gids & Phaff (1982), Larsen & Heiselberg (2008), Caciolo (2013), Tang (2016), and EN16798–7 (2017) models. The study also analyzed the cause of model prediction errors with respect to building characteristics such as weather station distance, building location, room floor, and incident wind direction. The results show that the distance between the school and the weather station has a significant impact on the model prediction accuracy. The prediction error generally exceeded 50 % with urban weather station data, while the actual ventilation rate was overestimated severely. The buoyancy and wind effects were overestimated by more than 2 times, due to the influence of the urban heat island effect and the complex built environment in the city. In addition, the prediction error related to the room floor was caused by the difference in environmental parameters, while the error related to the incident wind direction was mainly due to the limitations of the existing models. The results of this study provide valuable insights for the practical application and further improvement of ventilation models., This research is part of the R&D project IAQ4EDU, reference no. PID2020–117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Model predictive control for managing indoor air quality levels in buildings

  • Tarragona Roig, Joan|||0000-0001-6776-4273
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Casals Casanova, Miquel|||0000-0001-5379-894X
In recent years, stricter regulations aimed at improving indoor air quality have led to increased energy consumption in ventilation systems. This is particularly noticeable in the service sector, where high occupancy requires frequent air renewal. Therefore, it is crucial to apply control methods in these buildings to ensure proper indoor air quality and comfortable temperatures at minimal energy consumption and cost. However, addressing these operational requirements demands the utilization of advanced control methods and the integration of renewable energy sources. In this context, this article aims to design a model predictive control capable of managing indoor air quality levels to ensure occupants’ comfort while minimizing operational costs. The novelty of this work lies in the development, for the first time, of a model predictive control that incorporates solar electricity production, changes in grid electricity prices, occupancy levels, and weather profiles. Additionally, several indoor CO2 concentration limits based on current regulations and building users’ activities were employed to evaluate the model performance. Results demonstrated that model predictive control could achieve economic savings of up to 15¿% when indoor CO2 concentration must be below 750¿ppm compared to binary control modulation with photovoltaic panels. Moreover, the model effectively shifted ventilation necessities to off-peak electricity hours and fully harnessed energy generated by photovoltaic panels. Consequently, the presented model predictive control exhibited promising performance for potential applications in service sector buildings., Peer Reviewed, Objectius de Desenvolupament Sostenible::13 - Acció per al Clima, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Assessing the impact of the COVID-19 lockdown on the energy consumption of university buildings

  • Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Casals Casanova, Miquel|||0000-0001-5379-894X
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
  • Forcada Matheu, Núria|||0000-0003-2109-4205
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
Exceptional pandemic lockdown measures enabled singular experiments such as analysing the energy consumption of vacant buildings. This paper assesses the impact of the COVID-19 lockdown on the energy use of academic buildings. For this purpose, weather-adjusted energy use was compared before and during the lockdown, including different levels of lockdown restrictions. Results obtained for the 83 academic buildings of Universitat Politècnica de Catalunya - Barcelona Tech (UPC) reveal that the avoided energy consumption amounted to over 4.3 GWh during the post-pandemic year. However, the results indicate that academic buildings were still using approximately 46.9% of their typical energy consumption during strict lockdown. This revelation emphasizes the high environmental burden of buildings, regardless of whether they are occupied., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::12 - Producció i Consum Responsables
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Hybrid grey box modelling of indoor air quality and thermal dynamics in indoor environments

  • Tugores Garcias, Juan|||0009-0002-8128-4625
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
The primary objective of this paper is to develop a hybrid grey box model that integrates air and thermal dynamics to improve accuracy in both domains. The methodology involved developing four grey box models to estimate ventilation airflows using indoor CO2 concentration data and six thermal models to estimate thermal properties and heat gains using indoor temperature data. To ensure accurate parameterization, measurements of outdoor conditions, occupancy, and HVAC operations were incorporated. The results revealed that models treating infiltration and mechanical ventilation as mutually exclusive (IAQ-3 and IAQ-4) and those integrating ventilation heat gains from estimated airflows (T-6) performed most effectively. This hybrid approach underscores the benefits of incorporating ventilation heat loos or gains, based on airflow estimation derived from indoor air quality (IAQ) models, into thermal modelling, significantly improving accuracy and reducing parameter variability. The findings demonstrate the potential of this methodology for applications in ventilation management and HVAC optimization. By enhancing energy efficiency and improving indoor air quality, this approach supports the development of healthier, more sustainable indoor environments., This research was supported by a predoctoral contract grant (reference no. PRE2021-099606) as part of the research and development project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by MCIN/AEI/10.13039/501100011033/FEDER, and is part of the project BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/501100011033 and by the European Union “NextGenerationEU”/PRTR. Moreover, this study was supported by the Catalan agency AGAUR through its research group support programme (2021 SGR 00341).
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Optimal ventilation strategies for balancing indoor air quality, comfort and energy use in educational buildings. The IAQ4EDU project.

  • Gaspar Fàbregas, Kàtia|||0000-0003-3842-1401
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Casals Casanova, Miquel|||0000-0001-5379-894X
  • Ferré Bigorra, Jaume|||0000-0002-0872-9547
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
Currently, there is great concern about adequate indoor ventilation to prevent adverse effects on occupants’ health, and, within educational buildings, to ensure students and professors’ well-being and improve learning processes. This paper aims to present an innovative framework, developed within the IAQ4EDU project, to improve the effectiveness of the ventilation strategies in educational centres considering the indoor air quality, thermal comfort, energy consumption and global costs. This consists on characterise indoor air quality, simulate building ventilation strategies using reduced order models and develop multi criteria decision making method. 40 classrooms located in 20 Spanish educational buildings are used as case study., This research is part of the Catalan agency AGAUR under their research group support programme (2017SGR00227)., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Educational environments’ energy demand optimization based on indoor CO2 concentration and temperature: together better than separately

  • Canals Casals, Lluc|||0000-0002-4791-9917
  • Ruiz de Alegría Sala, Alba|||0000-0001-7149-6873
  • Bonet, Neus
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
Although optimization tools have been widely used to both minimize and control the energy consumption of buildings maintaining thermal comfort, the dramatic impact of the COVID-19 pandemic showed the relevance of considering the indoor air quality to act on the ventilation system. However, CO2 concentrations in closed environments with high occupancy rates, such as classrooms in schools, universities, or other educational environments, increase rapidly without effective ventilation, reaching the safe limits in about 15–30 min. Observing that the natural ventilation guides indicated by governments were insufficient to keep safe and comfortable spaces simultaneously, this study analyzes how mechanical heating, cooling, and ventilation systems would improve these results by using optimized control strategies in the same buildings that now use natural ventilation. Setting the objective function to minimize energy consumption, this study optimizes the use of mechanical systems considering the indoor temperature and CO2 concentration of educational indoor spaces in 4 types of schools and 3 climate zones in winter and summer. Results show that, at full occupancy, the ventilation should activate every 12 min, making slow-frequency control strategies inappropriate to keep the spaces safe. A 1-min step modeling asks for high computation that makes it critical for real-time control strategies, however, it allows a perfect setting of the working limits for legacy conditional equipment for establishing control policies on a one-day horizon., This research is part of the R&D projectIAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033 and supported by the Catalan agency AGAUR through their research group support program to the ENMA and GRIC research groups certified as 2021 SGR 00226 and SGR 00341 respectively. Moreover, this research is partially supported by the projects MOVE4- EDU (reference no. PID2021-126845OB-C22), funded by MCIN/AEI/ 10.13039/501100011033/FEDER, UE, and BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/ 501100011033 as well as by the European Union “NextGenerationEU”/ PRTR. LCC also acknowledges the Serra Húnter Program.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Data-driven model for predicting indoor air quality and thermal comfort levels in naturally ventilated educational buildings using easily accessible data for schools

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
Modeling indoor air quality and thermal conditions in educational buildings is significant for protecting students' health, well-being, and productivity. The predictive models in existing studies were mainly built and applied in controlled environments with HVAC systems. These models did not involve occupant-related factors, had limited scope in a single building or space, and required indoor environmental monitoring data for the model input. This limits the applicability and generalization ability of the model in a large number of schools relying on natural ventilation, where indoor air quality and thermal conditions are significantly affected by occupants’ activities and ventilation practices. Hence, this paper proposes a methodology to develop a data-driven model for predicting the level of indoor air quality and thermal comfort in naturally ventilated educational buildings, and identifies the key influential factors. The model was developed using the class-weighted random forest algorithm with data collected from a large measurement campaign. The developed model demonstrated good accuracy, generalization ability, and robustness. The analysis concluded that occupancy, windows and doors operation, and outdoor environmental parameters are key factors must be involved, whereas building characteristics have no practical contribution to the prediction. The model inputs are easily accessible data for schools. Once the model is developed with data collected from an initial measurement campaign in representative educational buildings, it can be used in all local schools without requiring monitoring sensor networks, thereby rendering a “cost-effective” way of assessing indoor air quality and thermal comfort to help relevant stakeholders improve building management practices in schools., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Estimation of children’s CO2 generation rates in naturally ventilated educational buildings

  • Tugores Garcias, Juan|||0009-0002-8128-4625
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
Indoor CO CO 2 2 concentration serves as an indicator of indoor air quality, which is mainly influenced by occupants’ generation rate, outdoor ventilation rate and outdoor CO 2 levels. Determining the CO 2 generation rate is fundamental to design effective ventilation systems that ensure good indoor air quality. The ASTM D6245 standard offers a method to estimate human CO 2 generation based on sex, age, body mass, and activity level. However, due to the limited number of studies on CO 2 generation rate for children and adolescents in daily scholarly activities, accurated values are difficult to estimate. This research uses a stochastic grey box modelling approach to estimate CO 2 generation rates in naturally ventilated schools and compares it with the standard approach. This method can address the complexities and variations in real educational environments. The proposed model was verified through an experimental campaign including 32 classrooms with students aged 4, 10, 13 and 16 years. The model provided a detailed description of the indoor CO 2 cases. Estimated CO 2 dynamics in 72% of the studied generation rates were found to be in line with the expected standard value of between 1.0 MET to 2.0 MET activity levels (7.07–12.65 L/h for a 4-year-old, 9.63–13.29 L/h for a 10-year-old, 14.54–19.32 L/h for a 13-year-old, and 12.11–20.53 L/h for a 16-year-old). These findings not only bridge the gap in children’s CO 2 generation rates but also introduce a novel approach to assess human CO uncontrolled conditions., This research was supported by predoctoral contract grants (reference no. PRE2021-099606) as a part of the R&D project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by MCIN/AEI/ 10.13039/501100011033/FEDER. This work was supported by the Catalan agency AGAUR through its research group support programme (2021 SGR 00341).The Government of Catalonia and Sabadell city council is gratefully acknowledged for allowing access to public centres. In addition, appreciation is extended to the MOVE4EDU project (reference no. PID2021-126845OB-C21 and PID2021-126845OB-C22), funded by MCIN/AEI/10.13039/501100011033/FEDER., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar::3.d - Reforçar la capacitat de tots els països, en particular els països en desenvolupament, en matèria d’alerta primerenca, reducció de riscos i gestió dels riscos per a la salut nacional i mundial, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.a - Construir i adequar instal·lacions escolars que responguin a les necessitats dels infants i les persones dis­capacitades, tinguin en compte les qüestions de gènere, i ofereixin entorns d’aprenentatge segurs, no violents, inclusius i eficaços per a totes les persones, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura::9.1 - Desenvolupar infraestructures fiables, sostenibles, resilients i de qualitat, incloent infraestructures regionals i transfrontereres, per tal de donar suport al desenvolupament econòmic i al benestar humà, amb especial atenció a l’accés assequible i equitatiu per a totes les persones, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

NVAPF: an adaptive particle filter algorithm for CO2-based natural ventilation rate estimation with high temporal resolution and stability

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
CO2-based ventilation rate estimation techniques have been widely used in relevant studies in naturally ventilated educational buildings. Such techniques are non-invasive, low-cost, simple, accurate, and do not interfere with the activities of indoor occupants. However, the estimation is significantly affected by the CO2 measurement noise, the uncertainties associated with CO2 generation rate, and complex natural ventilation dynamics. Existing techniques were found to have limited capabilities to deal with these aspects. Therefore, this research proposed an adaptive particle filter algorithm for CO2-based natural ventilation rate estimation and validated it through a case study in an educational building. Compared with the existing transient mass balance model and the extended Kalman filter technique, the estimation stability has been improved by nearly 6 times and 3 times, respectively. More importantly, the proposed algorithm is significantly more robust to abrupt changes in indoor CO2 and can effectively avoid large drifts in the estimated ventilation rate due to sudden window opening and sudden changes in room occupancy, demonstrating great practical applicability for real-time estimation with a high temporal resolution of 1 minute. To help relevant users with practical applications, the study also analyzed the algorithm parameter settings and the impact of simplification strategies commonly used in relevant studies, such as the use of a fixed outdoor CO2 concentration, an averaged CO2 generation rate, and an assumed constant room occupancy. Finally, considering that applying the proposed algorithm requires programming skills, an open, user-friendly software has been developed for relevant users for a convenient implementation., This research is part of the R&D project IAQ4EDU, reference no. PID2020–117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, 4 - Educació de Qualitat
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A comprehensive assessment of indoor air quality and thermal comfort in educational buildings in the Mediterranean climate

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
Maintaining good indoor air quality and thermal comfort is a challenge for naturally ventilated educational buildings, as it can be difficult to achieve both aspects simultaneously. Nonetheless, most of the existing studies only focus on one aspect. To explore the potential of balancing indoor air quality and thermal comfort, both topics must be investigated concurrently. This study assessed indoor air quality and thermal comfort in 32 naturally ventilated classrooms of 16 primary and secondary schools in the Mediterranean climate, based on a large on-site measurement campaign lasting one year that gathered over 460 hours of data. The research investigated occupants’ adaptive behaviors, analyzed the actual thermal comfort of around 600 students, and characterized the representative scenarios leading to good and poor indoor air quality and thermal comfort by clustering analysis. The results showed that poor indoor air quality was mainly due to closing windows and doors in winter, while thermal discomfort mainly occurred in summer because of the high indoor temperature. The findings suggested that a proper ventilation protocol is the key to balancing indoor air quality and thermal comfort., This research is part of the R&D project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by the MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student (reference no. 202208390065)., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Modelling indoor air quality in schools using grey box models

  • Tugores Garcias, Juan|||0009-0002-8128-4625
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Casals Casanova, Miquel|||0000-0001-5379-894X
Current indoor air quality strategies are based on the measurement and control of carbon dioxide (CO2) indoor concentration. Most educational buildings rely only on natural ventilation, making indoor air quality highly dependent on weather conditions. Therefore, to ensure the safety and well-being of students and teachers, it is necessary to determine the factors influencing CO2 concentration in naturally ventilated spaces. The aim of this paper is to estimate the students’ CO2 emission rates in naturally ventilated classrooms using grey box models., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Characterization of the demand response capabilities of educational buildings through explicit energy flexibility index

  • Canals Casals, Lluc|||0000-0002-4791-9917
  • Ruiz de Alegría Sala, Alba|||0000-0001-7149-6873
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
This study investigates the energy flexibility capabilities of educational buildings in Catalonia, focusing on their potential for demand response services without compromising indoor air quality and thermal comfort. After monitoring CO2 concentration and temperature across various educational levels and climate zones, this study applies reduced-order models and electric equivalent circuit models to optimize the building’s energy consumption and evaluate each building’s energy flexibility. The research differentiates between implicit energy flexibility, which manages internal building efficiency (energy optimization), and explicit energy flexibility, which adjusts energy consumption in response to external signals to provide services. A novel Explicit Energy Flexibility Index is developed to quantify the explicit capability using parameters such as power, capacity, reliability, symmetry, rebound effect, and seasonality. The results present high asymmetry, with reliable downward flexibility but limited upward capacity due to the system’s optimization, which is focused on minimizing consumption. The findings suggest that, while current educational buildings offer modest demand response potential, strategic investments in building envelopes and mechanical ventilation can enhance energy efficiency and flexibility., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033 and supported by the Catalan agency AGAUR through their research group support program to the ENMA and GRIC research groups certified as 2021 SGR 00226 and SGR 00341 respectively. Moreover, this research is partially supported by the projects MOVE4 EDU (reference no. PID2021-126845OB-C22), funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, and BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/501100011033 and by the European Union “NextGenerationEU”/PRTR. LCC also acknowledges the Serra Húnter Program., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A systematic review on MIVES: a sustainability-oriented multi-criteria decision-making method

  • Boix Cots, David|||0000-0002-8462-8887
  • Pardo Bosch, Francesc|||0000-0001-9532-8508
  • Blanco Álvarez, Ana|||0000-0003-4190-9846
  • Aguado de Cea, Antonio|||0000-0001-5542-6365
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
Sustainability has practically become a mandatory concept to be considered in every decision, and multiple decision-making methods have been adapted to take it into account. Among them, sustainability centred methods are also known as sustainability assessments, which provides sustainability indexes to select and prioritize alternatives. One of these most recent presented techniques is MIVES, a multi attribute utility theory multi-criteria decision-making value function-based method initially developed to introduce environmental and social indicators in civil engineering design decisions and later adapted for general evaluation and prioritization of homogenous and heterogeneous alternatives. Over the last decade, it has been widely studied and applied to specific situations, but a MIVES summary is currently lacking. Therefore, in this paper MIVES literature is reviewed with a deep bibliometric analysis carried out to provide on multiple data about MIVES state-of-the-art. Furthermore, a thematic clusters categorisation is done to reveal the usefulness of MIVES as design and decision-making tool, cataloguing the wide applications of MIVES as sustainability index. Finally, a MIVES characteristics discussion is carried out to help researchers deepen their knowledge towards the method and highlight potential future research pathways., The first author acknowledges the Goverment of Spain: Ministry of Education, Culture and Sports [grant number FPU18/01471]. The second and last author wishes to recognize the support from Serra Hunter programme. Finally, this work was supported by Catalan agency AGAUR trough their research groups support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A hierarchical integration method under social constraints to maximize satisfaction in multiple criteria group decision making systems

  • Boix Cots, David|||0000-0002-8462-8887
  • Pardo Bosch, Francesc|||0000-0001-9532-8508
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
Aggregating multiple opinions or assessments in a decision has always been a challenging field topic for researchers. Over the last decade, different approaches, mainly based on weighting data sources or decision-makers (DMs), have been proposed to resolve this issue, although social choice theory, focused on frameworks to combine individual opinions, is generally overlooked. To resolve this situation, a novel methodology is developed in this paper based on social choice theory and statistical mathematics. This method innovates by dividing the assessment into components which provides a multiple assessment analysis, assigning weights to each source regarding their position compared to the group for each considered criteria. This multiple-weighting process maximises individual and group satisfaction. Furthermore, the method makes it possible to manage previously assigned influence. An example is given to illustrate the proposed methodology. Additionally, sensitivity analysis is performed and comparisons with other methods are made. Finally, conclusions are presented., The first author acknowledges support from the Spanish Ministry of Education, Culture and Sports [grant number FPU18/01471]. The second and third author wish to recognise their support from the Serra Hunter programme. Finally, this work was supported by the Catalan agency AGAUR through its research group support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Assessing the fluctuation of indoor thermal conditions in naturally ventilated classrooms through K-means clustering

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
For naturally ventilated classrooms, windows should be constantly open to maintain good indoor air quality during class times. However, it is unknown whether this would result in significant fluctuations in the indoor thermal environment, while the effects of ventilation rate and window operation are still unclear. Therefore, this study assesses the fluctuation of indoor thermal conditions under natural ventilation during class periods, based on the K-means clustering and statistical analysis of data collected in a large measurement campaign in Spanish schools. The results showed that regardless of the heating mode, the indoor thermal parameters remained stable in most cases. High fluctuations were observed only in a few cases: 15% for indoor temperature, 6% for relative humidity, and 3% for indoor air velocity. The variability of the indoor thermal parameters within an hour was less than 1°C for indoor temperature, 3% for relative humidity, and 0.1¿m/s for indoor air velocity. Ventilation rate and window operation were found to be related to the fluctuation of the indoor temperature and air velocity, rather than the relative humidity. These findings shed light on the thermal conditions in naturally ventilated classrooms and have practical implications for the implementation of natural ventilation protocols in schools., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A novel approach to calculate the mean thermal sensation vote for primary and secondary schools using Bayesian inference

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
Existing thermal comfort models defined in relevant standards are often found to be less effective for primary and secondary school students in educational buildings. This is often thought to be primarily due to differences in thermal sensation between children and adults. However, one important factor that is often neglected is the uncertainty associated with thermal comfort survey data. The existing method for calculating the mean thermal sensation vote is oversimplified and does not properly address related uncertainties. As a result, it ultimately affects the performance of the developed thermal comfort models. Hence, this research proposes a novel approach to compute the mean thermal sensation vote data for primary and secondary schools using Bayesian inference. This approach addresses the error caused by the uncertainties associated with the collected thermal sensation vote data in order to improve the effectiveness of the developed thermal comfort models for students. The proposed method was validated through a holistic case study using five thermal comfort models. The results showed that the accuracy of the developed thermal comfort models improved by 10.1% to 30.9%, and the R2 improved by 5.3% to 28.8%. A benchmark for the Bayesian model parameter setting was proposed as the reference for relevant studies. Finally, an open, user-friendly software was developed and is available to relevant users to implement the proposed approach more efficiently. The results of this research have practical implications for the development and optimization of thermal comfort models for students., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Assessment of airborne infection risk in naturally ventilated environments

  • Tugores Garcias, Juan|||0009-0002-8128-4625
  • Macarulla Martí, Marcel|||0000-0002-5469-7291
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
During the COVID-19 pandemic, natural ventilation emerged as a widely recommended strategy to improve indoor air quality and reduce airborne infection risks. However, due to the inert uncertainty, accurately determining natural ventilation rates to assess the true impact of this practice proved challenging for building managers. Traditionally, the Wells-Riley approach has been used for airborne infection probability risk assessment when steady-state conditions are assumed. However, when this method is applied to naturally ventilated facilities, it may yield inaccuracies because of irregular ventilation rates caused by the occupants’ window opening patterns. The paper introduces a novel methodology for evaluating airborne infection probability in naturally ventilated environments. Firstly, natural ventilation rates are estimated using a grey box model of indoor CO2 concentration. This approach was validated using in-situ data from a case study in different periods (spring, summer and winter). Then, the infection probability risk was calculated by discretizing the accumulative virus portion inhaled by the occupants at each time. The results prove the grey box model's effectiveness in estimating natural ventilation rates in educational facilities. Concerning the evaluation of infection probability risk, the proposed approach aligns with observations in previous research that link lower ventilation rates with higher infection risk. However, the methodology provides a better representation of real-world variability than the Wells-Riley approach and enables the identification of vulnerable periods. The integration of this methodology into natural ventilation system management could optimize window-opening strategies to mitigate airborne transmission diseases in educational facilities, considering diverse infective incidence rates and pathogens., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar::3.d - Reforçar la capacitat de tots els països, en particular els països en desenvolupament, en matèria d’alerta primerenca, reducció de riscos i gestió dels riscos per a la salut nacional i mundial, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.a - Construir i adequar instal·lacions escolars que responguin a les necessitats dels infants i les persones dis­capacitades, tinguin en compte les qüestions de gènere, i ofereixin entorns d’aprenentatge segurs, no violents, inclusius i eficaços per a totes les persones
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Investigating students' subjective comfort with window-airing during the cold season: thermal sensation, humidity, air movement, and perceived air quality

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
Balancing the need for indoor air quality and thermal comfort during cold seasons is challenging for naturally ventilated schools. For students' health concerns, opening windows to ventilate during class time could be inevitable in winter, especially during flu season. However, there is a lack of field studies investigating its potential impacts on students' comfort. In this context, this study investigated students' subjective comfort with window airing in winter through a field study in the Mediterranean climate, with a total of 34 field experiments with different window opening scenarios conducted in two university classrooms. The study analyzed the effect of thermal sensation, humidity, air movement, and perceived air quality on students' comfort and identified correlated environmental parameters. The results showed that students' comfort was mainly determined by thermal sensation and air movement, while they were not very sensitive to indoor humidity and air quality. Their thermal sensation was found to be directly determined by the indoor temperature and not correlated with the outdoor temperature. Achieving the required ventilation rate would not cause obvious discomfort in terms of air movement. Moreover, the study validated 4 main adaptive PMV models (nPMV, adPMV, arPMV, and epmPMV) and found them to be ineffective with forced window openings. The proposed comfort prediction model suggests that to meet the ventilation rate requirement, the indoor temperature should be maintained above 21¿ to avoid causing thermal discomfort problems. The specific practical recommendations are given in the conclusions., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Estudio, informe, memoria (Report)

D6.4 Report on dissemination activities of the project

  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tugores Garcias, Juan|||0009-0002-8128-4625
  • Casals Francàs, Laia
  • Maiques Garcia, Maria|||0009-0005-6506-1589
  • Borruey Boquera, Carme
The main objective of the research project entitled IAQ4EDU — Optimal ventilation strategies for balancing indoor air quality, comfort and energy use in educational buildings (PID PID2020-117366RB-I00), funded by MCIN/ AEI/10.13039/501100011033 is to optimize the ventilation strategies in educational buildings taking into account the indoor air quality, thermal comfort, energy consumption and global costs (including investment and operation costs). This report represents Deliverable 6.4 Report on dissemination activities of the project developed in the course of WP6 Maximizing the IAQ4EDU impact: dissemination and communication. This deliverable is the last of the four complimentary documents produced in WP6 reporting the planned and performed dissemination activities. This document reports communication and dissemination activities undertaken during the course of the IAQ4EDU project. This deliverable first describes the development of the project communication channels and tools, including the project website, social media networks, newsletters, press notes, slides, posters and videos. In this sense, it is worth to highlight at the end of the project, the IAQ4EDU project website has registered more than 1.260 sessions and the IAQ4EDU social networks have reached 41 posts and 473 followers. To maximize the project's reach and impact, a series of targeted dissemination actions were carried out across multiple sectors: 1. The IAQ4EDU project made significant contributions to the research and academic community, including the publication of 19 articles in high-impact journals, participation in 5 conferences, and 3 invited presentations. Additionally, the project produced 2 open-access datasets and a software tool for optimizing natural ventilation in educational buildings. As a result, 4 copyrights for the project results are registered in the SafeCreative digital service. Furthermore, a total of 3 doctoral theses were written within the context of the IAQ4EDU project. Four awards recognizing the project contributions to research and innovation in thermal comfort, indoor air quality and energy efficiency have been received. 2. Initiatives have been launched to engage key stakeholders, including 3 actions aimed at raising awareness among the educational community and 3 actions directed towards public authorities and educational building managers, ensuring that decision-makers were informed about the project's findings and recommendations. Moreover, a total of 2 videos have been produced. 3. The project gained widespread visibility through numerous publications in significant newspapers, journals, and social media, effectively communicating key results to the general public., Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
UPCommons. Portal del coneixement obert de la UPC
Publication Estudio, informe, memoria (Report)

D4.2 Operational guide for maintaining good indoor air quality and thermal comfort with natural ventilation in educational buildings

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
This document presents the natural ventilation operational guide for educational buildings developed by the IAQ4EDU project. Most educational buildings are completely naturally ventilated. This challenges the indoor environmental quality management of schools in terms of balancing the needs of students for indoor air quality and thermal comfort. This guide presents the conditions and methods of using natural ventilation strategies to maintain good air quality and thermal comfort in classrooms. Using the example of Catalonia (Spain), a general ventilation protocol was developed to guide teachers in implementing natural ventilation in different seasons to ensure air quality during school hours. Relevant users can refer to the case in this practical guide to develop ventilation protocols based on the local climate and school conditions., Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A systematic review on multi-criteria group decision-making methods based on weights: analysis and classification scheme

  • Boix Cots, David|||0000-0002-8462-8887
  • Pardo Bosch, Francesc|||0000-0001-9532-8508
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
Interest in group decision-making (GDM) has been increasing prominently over the last decade. Access to global databases, sophisticated sensors which can obtain multiple inputs or complex problems requiring opinions from several experts have driven interest in data aggregation. Consequently, the field has been widely studied from several viewpoints and multiple approaches have been proposed. Nevertheless, there is a lack of general framework. Moreover, this problem is exacerbated in the case of experts’ weighting methods, one of the most widely-used techniques to deal with multiple source aggregation. This lack of general classification scheme, or a guide to assist expert knowledge, leads to ambiguity or misreading for readers, who may be overwhelmed by the large amount of unclassified information currently available. To invert this situation, a general GDM framework is presented which divides and classifies all data aggregation techniques, focusing on and expanding the classification of experts’ weighting methods in terms of analysis type by carrying out an in-depth literature review. Results are not only classified but analysed and discussed regarding multiple characteristics, such as MCDMs in which they are applied, type of data used, ideal solutions considered or when they are applied. Furthermore, general requirements supplement this analysis such as initial influence, or component division considerations. As a result, this paper provides not only a general classification scheme and a detailed analysis of experts’ weighting methods but also a road map for researchers working on GDM topics or a guide for experts who use these methods. Furthermore, six significant contributions for future research pathways are provided in the conclusions., The first author acknowledges support from the Spanish Ministry of Universities [grant number FPU18/01471]. The second and third author wish to recognize their support from the Serra Hunter program. Finally, this work was supported by the Catalan agency AGAUR through its research group support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Improving the thermal comfort model for students in naturally ventilated schools: Insights from a holistic study in the Mediterranean climate

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
The thermal comfort models defined in existing standards are usually ineffective in predicting students' mean thermal sensation. Accordingly, overheating and overcooling are frequently reported, which affect students’ well-being and cause unnecessary energy waste. Existing studies have not further explored the model improvement strategies for educational buildings. Hence, this research aims to improve the mean thermal sensation prediction model for students in naturally ventilated schools by incorporating correlated factors, based on a holistic field survey in the Mediterranean climate. The results indicate that the modified extended predicted mean vote of thermal adaptations reinforced around thermal neutrality has the highest accuracy among all validated adaptive predicted mean vote models. However, the performance of the adaptive predicted mean vote models is limited by the deficiencies of the original predicted mean vote model. The overall performance of the improved models was doubled after introducing the identified correlated factors, but the intrinsic error of the predicted mean vote index can slightly affect the models. As a result, the improved model built directly with the identified correlated factors achieved the best performance. Moreover, the potential of the machine learning models is limited by the volume of the mean thermal sensation vote data that can often be obtained, therefore conventional models such as multiple linear regression can be considered an effective and practical tool for developing the mean thermal sensation vote models. The findings of this study benefit the well-being of students and the energy conservation of educational buildings., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::5 - Igualtat de Gènere, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A MIVES-Based Multicriteria Framework for Prioritizing Indoor Air Quality Interventions in Educational Classrooms

  • Pardo Bosch, Francesc|||0000-0001-9532-8508
  • López Carreño, Rubén-Daniel|||0000-0003-1040-5135
  • Aidarov, Stanislav|||0000-0001-5576-7215
  • Pujadas Álvarez, Pablo|||0000-0001-5634-7431
Indoor air quality (IAQ) in educational buildings has become a key priority, especially after the COVID-19 pandemic, due to thehigh vulnerability of children and a widespread lack of e¿ective ventilation systems in classrooms. This study introduces a MIVES-based multicriteria decision-making (MCDM) framework to prioritize IAQ improvement investments in classrooms, aligningthem with prede¿ned sustainable development objectives. The MIVES methodology combines MCDM and multiattributeutility theory (MAUT), incorporating the concept of value functions (VFs) to standardize indicators, and uses the analytichierarchy process (AHP) to assign relative weights across evaluation criteria. The proposed prioritization investment index forindoor air quality (PIIIAQ) integrates a risk index (RI)—based on threat, the population at risk, and the classroomvulnerability—with a comprehensive sustainability assessment across economic, social, and environmental dimensions. Theframework was applied to 14 intervention strategies (Projects A to N) across various Spanish schools, producing accurate,consistent, and repeatable evaluations in a transparent and traceable way. Project K, which involved installing a completeHVAC system in a high-risk classroom (RI = 4 54), received the highest PIIIAQ score (0.81), followed by Projects M and J(0.75), while lower-ranked projects such as E (0.36) and B (0.39) o¿ered minimal improvement or impact. A sensitivityanalysis con¿rmed the robustness of results across di¿erent stakeholder-weighting scenarios. The model's output closelymatched expert judgment, validating its reliability and demonstrating its potential as a strategic tool for guiding resourceallocation in public educational infrastructure.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A long short-term memory physics-informed neural network model for CO2-based natural ventilation rate estimation

  • Miao, Sen|||0000-0003-0266-9405
  • Gangolells Solanellas, Marta|||0000-0001-7921-595X
  • Tejedor Herrán, Blanca|||0000-0002-2064-0617
The occupant-released CO2 tracer gas approach has been widely used for ventilation rate estimation. This approach is non-invasive, low-cost, and does not interfere with the occupants’ activities. However, the CO2 measurement noise and CO2 generation uncertainties can significantly affect the accuracy of the estimated ventilation rates, while the dynamics of the natural ventilation rates could challenge the stability of the estimators. As commonly applied techniques, the moving average filter and the extended Kalman filter have their own advantages and limitations in addressing these issues. To further address the challenges in the natural ventilation rate estimation, this paper proposes a novel model named “NVR-PINN”, based on the long short-term memory-physics-informed neural network and validates it with a case study. The proposed model combines the strengths of the moving average filter and the extended Kalman filter, demonstrating better practical values. It is capable of handling both CO2 measurement noise and CO2 generation uncertainty, effectively capturing the temporal dynamics of the natural ventilation rate, while processing the entire time series observation with a defined sequence window to yield more stable and consistent estimates. The analysis of the case study also revealed useful evidence for relevant research with regard to the applicability of existing ventilation rate estimation techniques., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Validating single-sided natural ventilation models for educational buildings

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
To maintain good indoor air quality in schools, it is often necessary to apply single-sided natural ventilation models using urban weather stations, since the local weather station is not available for most schools. However, the field study that validated the ventilation models with full-scale experiments in classrooms is very limited. Therefore, this study validated 6 existing single-sided ventilation models based on two field measurement campaigns conducted in naturally ventilated educational buildings, including the Warren & Parkins (1977 & 1985), De Gids & Phaff (1982), Larsen & Heiselberg (2008), Caciolo (2013), Tang (2016), and EN16798–7 (2017) models. The study also analyzed the cause of model prediction errors with respect to building characteristics such as weather station distance, building location, room floor, and incident wind direction. The results show that the distance between the school and the weather station has a significant impact on the model prediction accuracy. The prediction error generally exceeded 50 % with urban weather station data, while the actual ventilation rate was overestimated severely. The buoyancy and wind effects were overestimated by more than 2 times, due to the influence of the urban heat island effect and the complex built environment in the city. In addition, the prediction error related to the room floor was caused by the difference in environmental parameters, while the error related to the incident wind direction was mainly due to the limitations of the existing models. The results of this study provide valuable insights for the practical application and further improvement of ventilation models., This research is part of the R&D project IAQ4EDU, reference no. PID2020–117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Characterization of the demand response capabilities of educational buildings through explicit energy flexibility index

  • Canals Casals, Lluc
  • Ruiz de Alegría Sala, Alba
  • Macarulla Martí, Marcel
This study investigates the energy flexibility capabilities of educational buildings in Catalonia, focusing on their potential for demand response services without compromising indoor air quality and thermal comfort. After monitoring CO2 concentration and temperature across various educational levels and climate zones, this study applies reduced-order models and electric equivalent circuit models to optimize the building’s energy consumption and evaluate each building’s energy flexibility. The research differentiates between implicit energy flexibility, which manages internal building efficiency (energy optimization), and explicit energy flexibility, which adjusts energy consumption in response to external signals to provide services. A novel Explicit Energy Flexibility Index is developed to quantify the explicit capability using parameters such as power, capacity, reliability, symmetry, rebound effect, and seasonality. The results present high asymmetry, with reliable downward flexibility but limited upward capacity due to the system’s optimization, which is focused on minimizing consumption. The findings suggest that, while current educational buildings offer modest demand response potential, strategic investments in building envelopes and mechanical ventilation can enhance energy efficiency and flexibility., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033 and supported by the Catalan agency AGAUR through their research group support program to the ENMA and GRIC research groups certified as 2021 SGR 00226 and SGR 00341 respectively. Moreover, this research is partially supported by the projects MOVE4 EDU (reference no. PID2021-126845OB-C22), funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, and BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/501100011033 and by the European Union “NextGenerationEU”/PRTR. LCC also acknowledges the Serra Húnter Program., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication

D6.4 Report on dissemination activities of the project

  • Gangolells Solanellas, Marta
  • Tugores Garcias, Juan
  • Casals Francàs, Laia
  • Maiques Garcia, Maria
  • Borruey Boquera, Carme
The main objective of the research project entitled IAQ4EDU — Optimal ventilation strategies for balancing indoor air quality, comfort and energy use in educational buildings (PID PID2020-117366RB-I00), funded by MCIN/ AEI/10.13039/501100011033 is to optimize the ventilation strategies in educational buildings taking into account the indoor air quality, thermal comfort, energy consumption and global costs (including investment and operation costs). This report represents Deliverable 6.4 Report on dissemination activities of the project developed in the course of WP6 Maximizing the IAQ4EDU impact: dissemination and communication. This deliverable is the last of the four complimentary documents produced in WP6 reporting the planned and performed dissemination activities. This document reports communication and dissemination activities undertaken during the course of the IAQ4EDU project. This deliverable first describes the development of the project communication channels and tools, including the project website, social media networks, newsletters, press notes, slides, posters and videos. In this sense, it is worth to highlight at the end of the project, the IAQ4EDU project website has registered more than 1.260 sessions and the IAQ4EDU social networks have reached 41 posts and 473 followers. To maximize the project's reach and impact, a series of targeted dissemination actions were carried out across multiple sectors: 1. The IAQ4EDU project made significant contributions to the research and academic community, including the publication of 19 articles in high-impact journals, participation in 5 conferences, and 3 invited presentations. Additionally, the project produced 2 open-access datasets and a software tool for optimizing natural ventilation in educational buildings. As a result, 4 copyrights for the project results are registered in the SafeCreative digital service. Furthermore, a total of 3 doctoral theses were written within the context of the IAQ4EDU project. Four awards recognizing the project contributions to research and innovation in thermal comfort, indoor air quality and energy efficiency have been received. 2. Initiatives have been launched to engage key stakeholders, including 3 actions aimed at raising awareness among the educational community and 3 actions directed towards public authorities and educational building managers, ensuring that decision-makers were informed about the project's findings and recommendations. Moreover, a total of 2 videos have been produced. 3. The project gained widespread visibility through numerous publications in significant newspapers, journals, and social media, effectively communicating key results to the general public., Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A long short-term memory physics-informed neural network model for CO2-based natural ventilation rate estimation

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
The occupant-released CO2 tracer gas approach has been widely used for ventilation rate estimation. This approach is non-invasive, low-cost, and does not interfere with the occupants’ activities. However, the CO2 measurement noise and CO2 generation uncertainties can significantly affect the accuracy of the estimated ventilation rates, while the dynamics of the natural ventilation rates could challenge the stability of the estimators. As commonly applied techniques, the moving average filter and the extended Kalman filter have their own advantages and limitations in addressing these issues. To further address the challenges in the natural ventilation rate estimation, this paper proposes a novel model named “NVR-PINN”, based on the long short-term memory-physics-informed neural network and validates it with a case study. The proposed model combines the strengths of the moving average filter and the extended Kalman filter, demonstrating better practical values. It is capable of handling both CO2 measurement noise and CO2 generation uncertainty, effectively capturing the temporal dynamics of the natural ventilation rate, while processing the entire time series observation with a defined sequence window to yield more stable and consistent estimates. The analysis of the case study also revealed useful evidence for relevant research with regard to the applicability of existing ventilation rate estimation techniques., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Investigating students' subjective comfort with window-airing during the cold season: thermal sensation, humidity, air movement, and perceived air quality

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
Balancing the need for indoor air quality and thermal comfort during cold seasons is challenging for naturally ventilated schools. For students' health concerns, opening windows to ventilate during class time could be inevitable in winter, especially during flu season. However, there is a lack of field studies investigating its potential impacts on students' comfort. In this context, this study investigated students' subjective comfort with window airing in winter through a field study in the Mediterranean climate, with a total of 34 field experiments with different window opening scenarios conducted in two university classrooms. The study analyzed the effect of thermal sensation, humidity, air movement, and perceived air quality on students' comfort and identified correlated environmental parameters. The results showed that students' comfort was mainly determined by thermal sensation and air movement, while they were not very sensitive to indoor humidity and air quality. Their thermal sensation was found to be directly determined by the indoor temperature and not correlated with the outdoor temperature. Achieving the required ventilation rate would not cause obvious discomfort in terms of air movement. Moreover, the study validated 4 main adaptive PMV models (nPMV, adPMV, arPMV, and epmPMV) and found them to be ineffective with forced window openings. The proposed comfort prediction model suggests that to meet the ventilation rate requirement, the indoor temperature should be maintained above 21¿ to avoid causing thermal discomfort problems. The specific practical recommendations are given in the conclusions., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A systematic review on MIVES: a sustainability-oriented multi-criteria decision-making method

  • Boix Cots, David
  • Pardo Bosch, Francesc
  • Blanco Álvarez, Ana
  • Aguado de Cea, Antonio
  • Pujadas Álvarez, Pablo
Sustainability has practically become a mandatory concept to be considered in every decision, and multiple decision-making methods have been adapted to take it into account. Among them, sustainability centred methods are also known as sustainability assessments, which provides sustainability indexes to select and prioritize alternatives. One of these most recent presented techniques is MIVES, a multi attribute utility theory multi-criteria decision-making value function-based method initially developed to introduce environmental and social indicators in civil engineering design decisions and later adapted for general evaluation and prioritization of homogenous and heterogeneous alternatives. Over the last decade, it has been widely studied and applied to specific situations, but a MIVES summary is currently lacking. Therefore, in this paper MIVES literature is reviewed with a deep bibliometric analysis carried out to provide on multiple data about MIVES state-of-the-art. Furthermore, a thematic clusters categorisation is done to reveal the usefulness of MIVES as design and decision-making tool, cataloguing the wide applications of MIVES as sustainability index. Finally, a MIVES characteristics discussion is carried out to help researchers deepen their knowledge towards the method and highlight potential future research pathways., The first author acknowledges the Goverment of Spain: Ministry of Education, Culture and Sports [grant number FPU18/01471]. The second and last author wishes to recognize the support from Serra Hunter programme. Finally, this work was supported by Catalan agency AGAUR trough their research groups support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Model predictive control for managing indoor air quality levels in buildings

  • Tarragona Roig, Joan
  • Gangolells Solanellas, Marta
  • Casals Casanova, Miquel
In recent years, stricter regulations aimed at improving indoor air quality have led to increased energy consumption in ventilation systems. This is particularly noticeable in the service sector, where high occupancy requires frequent air renewal. Therefore, it is crucial to apply control methods in these buildings to ensure proper indoor air quality and comfortable temperatures at minimal energy consumption and cost. However, addressing these operational requirements demands the utilization of advanced control methods and the integration of renewable energy sources. In this context, this article aims to design a model predictive control capable of managing indoor air quality levels to ensure occupants’ comfort while minimizing operational costs. The novelty of this work lies in the development, for the first time, of a model predictive control that incorporates solar electricity production, changes in grid electricity prices, occupancy levels, and weather profiles. Additionally, several indoor CO2 concentration limits based on current regulations and building users’ activities were employed to evaluate the model performance. Results demonstrated that model predictive control could achieve economic savings of up to 15¿% when indoor CO2 concentration must be below 750¿ppm compared to binary control modulation with photovoltaic panels. Moreover, the model effectively shifted ventilation necessities to off-peak electricity hours and fully harnessed energy generated by photovoltaic panels. Consequently, the presented model predictive control exhibited promising performance for potential applications in service sector buildings., Peer Reviewed, Objectius de Desenvolupament Sostenible::13 - Acció per al Clima, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A simplified classroom indoor air quality risk index: application in the Mediterranean Region to support the enhanced design of educational environments

  • López Carreño, Rubén-Daniel
  • Pardo Bosch, Francesc
  • Aidarov, Stanislav
  • Boix Cots, David
  • Pujadas Álvarez, Pablo
The quality of indoor environments within educational settings significantly impacts the health, safety, and comfort of occupants. In this manuscript, a simplified Classroom Indoor Air Quality (CIAQ) Risk Index, aimed at assessing the potential ability of classrooms to maintain CO2 levels within acceptable limits, is introduced. Comprising three primary components—the likelihood of surpassing predefined CO2 thresholds, the potential number of individuals exposed, and the classroom’s capacity to withstand or mitigate threats—this index serves as a valuable compliance tool during both the design phase and operational management of educational spaces. Additionally, apart from presenting the index framework, a sensitivity case study analysis is carried out to verify the suitability of the proposed method and the sensitivity of the factors involved. Through this analysis, the robustness of the CIAQ Risk Index in various scenarios is demonstrated. By quantifying and evaluating potential risks associated with indoor air quality, the CIAQ Risk Index contributes to ongoing efforts to create healthier indoor environments. Furthermore, it facilitates the identification of budgetary mitigation strategies that should positively affect the air quality; among those, an intervention, retrofitting, and ventilation improvements can be listed. Through proactive risk identification and appropriate actions, including regulation adjustments and ventilation strategies, the reduction in health problems, the enhancement of well-being, and the improvement of overall performance and quality of life for educational communities can be achieved., This study is conducted as part of the R&D project IAQ4EDU (reference no. PID2020117366RB-I00), funded by MCIN/AEI/10.13039/501100011033. P.P. and F.P. acknowledge the support provided by the Serra Húnter program. Additionally, this work has received funding from the Agència de Gestió d’Ajuts Universitaris i de Recerca (AGAUR) under the research group support program (2021 SGR 00341)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Educational environments’ energy demand optimization based on indoor CO2 concentration and temperature: together better than separately

  • Canals Casals, Lluc
  • Ruiz de Alegría Sala, Alba
  • Bonet, Neus
  • Macarulla Martí, Marcel
Although optimization tools have been widely used to both minimize and control the energy consumption of buildings maintaining thermal comfort, the dramatic impact of the COVID-19 pandemic showed the relevance of considering the indoor air quality to act on the ventilation system. However, CO2 concentrations in closed environments with high occupancy rates, such as classrooms in schools, universities, or other educational environments, increase rapidly without effective ventilation, reaching the safe limits in about 15–30 min. Observing that the natural ventilation guides indicated by governments were insufficient to keep safe and comfortable spaces simultaneously, this study analyzes how mechanical heating, cooling, and ventilation systems would improve these results by using optimized control strategies in the same buildings that now use natural ventilation. Setting the objective function to minimize energy consumption, this study optimizes the use of mechanical systems considering the indoor temperature and CO2 concentration of educational indoor spaces in 4 types of schools and 3 climate zones in winter and summer. Results show that, at full occupancy, the ventilation should activate every 12 min, making slow-frequency control strategies inappropriate to keep the spaces safe. A 1-min step modeling asks for high computation that makes it critical for real-time control strategies, however, it allows a perfect setting of the working limits for legacy conditional equipment for establishing control policies on a one-day horizon., This research is part of the R&D projectIAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033 and supported by the Catalan agency AGAUR through their research group support program to the ENMA and GRIC research groups certified as 2021 SGR 00226 and SGR 00341 respectively. Moreover, this research is partially supported by the projects MOVE4- EDU (reference no. PID2021-126845OB-C22), funded by MCIN/AEI/ 10.13039/501100011033/FEDER, UE, and BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/ 501100011033 as well as by the European Union “NextGenerationEU”/ PRTR. LCC also acknowledges the Serra Húnter Program., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Modelling indoor air quality in schools using grey box models

  • Tugores Garcias, Juan
  • Macarulla Martí, Marcel
  • Gangolells Solanellas, Marta
  • Casals Casanova, Miquel
Current indoor air quality strategies are based on the measurement and control of carbon dioxide (CO2) indoor concentration. Most educational buildings rely only on natural ventilation, making indoor air quality highly dependent on weather conditions. Therefore, to ensure the safety and well-being of students and teachers, it is necessary to determine the factors influencing CO2 concentration in naturally ventilated spaces. The aim of this paper is to estimate the students’ CO2 emission rates in naturally ventilated classrooms using grey box models., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Hybrid grey box modelling of indoor air quality and thermal dynamics in indoor environments

  • Tugores Garcias, Juan
  • Macarulla Martí, Marcel
  • Gangolells Solanellas, Marta
The primary objective of this paper is to develop a hybrid grey box model that integrates air and thermal dynamics to improve accuracy in both domains. The methodology involved developing four grey box models to estimate ventilation airflows using indoor CO2 concentration data and six thermal models to estimate thermal properties and heat gains using indoor temperature data. To ensure accurate parameterization, measurements of outdoor conditions, occupancy, and HVAC operations were incorporated. The results revealed that models treating infiltration and mechanical ventilation as mutually exclusive (IAQ-3 and IAQ-4) and those integrating ventilation heat gains from estimated airflows (T-6) performed most effectively. This hybrid approach underscores the benefits of incorporating ventilation heat loos or gains, based on airflow estimation derived from indoor air quality (IAQ) models, into thermal modelling, significantly improving accuracy and reducing parameter variability. The findings demonstrate the potential of this methodology for applications in ventilation management and HVAC optimization. By enhancing energy efficiency and improving indoor air quality, this approach supports the development of healthier, more sustainable indoor environments., This research was supported by a predoctoral contract grant (reference no. PRE2021-099606) as part of the research and development project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by MCIN/AEI/10.13039/501100011033/FEDER, and is part of the project BINAFET (reference no. TED2021-130047B-C22), funded by MCIN/AEI/10.13039/501100011033 and by the European Union “NextGenerationEU”/PRTR. Moreover, this study was supported by the Catalan agency AGAUR through its research group support programme (2021 SGR 00341)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication

D4.2 Operational guide for maintaining good indoor air quality and thermal comfort with natural ventilation in educational buildings

  • Miao, Sen
  • Gangolells Solanellas, Marta
This document presents the natural ventilation operational guide for educational buildings developed by the IAQ4EDU project. Most educational buildings are completely naturally ventilated. This challenges the indoor environmental quality management of schools in terms of balancing the needs of students for indoor air quality and thermal comfort. This guide presents the conditions and methods of using natural ventilation strategies to maintain good air quality and thermal comfort in classrooms. Using the example of Catalonia (Spain), a general ventilation protocol was developed to guide teachers in implementing natural ventilation in different seasons to ensure air quality during school hours. Relevant users can refer to the case in this practical guide to develop ventilation protocols based on the local climate and school conditions., Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Preprint
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A systematic review on multi-criteria group decision-making methods based on weights: analysis and classification scheme

  • Boix Cots, David
  • Pardo Bosch, Francesc
  • Pujadas Álvarez, Pablo
Interest in group decision-making (GDM) has been increasing prominently over the last decade. Access to global databases, sophisticated sensors which can obtain multiple inputs or complex problems requiring opinions from several experts have driven interest in data aggregation. Consequently, the field has been widely studied from several viewpoints and multiple approaches have been proposed. Nevertheless, there is a lack of general framework. Moreover, this problem is exacerbated in the case of experts’ weighting methods, one of the most widely-used techniques to deal with multiple source aggregation. This lack of general classification scheme, or a guide to assist expert knowledge, leads to ambiguity or misreading for readers, who may be overwhelmed by the large amount of unclassified information currently available. To invert this situation, a general GDM framework is presented which divides and classifies all data aggregation techniques, focusing on and expanding the classification of experts’ weighting methods in terms of analysis type by carrying out an in-depth literature review. Results are not only classified but analysed and discussed regarding multiple characteristics, such as MCDMs in which they are applied, type of data used, ideal solutions considered or when they are applied. Furthermore, general requirements supplement this analysis such as initial influence, or component division considerations. As a result, this paper provides not only a general classification scheme and a detailed analysis of experts’ weighting methods but also a road map for researchers working on GDM topics or a guide for experts who use these methods. Furthermore, six significant contributions for future research pathways are provided in the conclusions., The first author acknowledges support from the Spanish Ministry of Universities [grant number FPU18/01471]. The second and third author wish to recognize their support from the Serra Hunter program. Finally, this work was supported by the Catalan agency AGAUR through its research group support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A MIVES-Based Multicriteria Framework for Prioritizing Indoor Air Quality Interventions in Educational Classrooms

  • Pardo Bosch, Francesc
  • López Carreño, Rubén-Daniel
  • Aidarov, Stanislav
  • Pujadas Álvarez, Pablo
Indoor air quality (IAQ) in educational buildings has become a key priority, especially after the COVID-19 pandemic, due to thehigh vulnerability of children and a widespread lack of e¿ective ventilation systems in classrooms. This study introduces a MIVES-based multicriteria decision-making (MCDM) framework to prioritize IAQ improvement investments in classrooms, aligningthem with prede¿ned sustainable development objectives. The MIVES methodology combines MCDM and multiattributeutility theory (MAUT), incorporating the concept of value functions (VFs) to standardize indicators, and uses the analytichierarchy process (AHP) to assign relative weights across evaluation criteria. The proposed prioritization investment index forindoor air quality (PIIIAQ) integrates a risk index (RI)—based on threat, the population at risk, and the classroomvulnerability—with a comprehensive sustainability assessment across economic, social, and environmental dimensions. Theframework was applied to 14 intervention strategies (Projects A to N) across various Spanish schools, producing accurate,consistent, and repeatable evaluations in a transparent and traceable way. Project K, which involved installing a completeHVAC system in a high-risk classroom (RI = 4 54), received the highest PIIIAQ score (0.81), followed by Projects M and J(0.75), while lower-ranked projects such as E (0.36) and B (0.39) o¿ered minimal improvement or impact. A sensitivityanalysis con¿rmed the robustness of results across di¿erent stakeholder-weighting scenarios. The model's output closelymatched expert judgment, validating its reliability and demonstrating its potential as a strategic tool for guiding resourceallocation in public educational infrastructure., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Assessing the fluctuation of indoor thermal conditions in naturally ventilated classrooms through K-means clustering

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
For naturally ventilated classrooms, windows should be constantly open to maintain good indoor air quality during class times. However, it is unknown whether this would result in significant fluctuations in the indoor thermal environment, while the effects of ventilation rate and window operation are still unclear. Therefore, this study assesses the fluctuation of indoor thermal conditions under natural ventilation during class periods, based on the K-means clustering and statistical analysis of data collected in a large measurement campaign in Spanish schools. The results showed that regardless of the heating mode, the indoor thermal parameters remained stable in most cases. High fluctuations were observed only in a few cases: 15% for indoor temperature, 6% for relative humidity, and 3% for indoor air velocity. The variability of the indoor thermal parameters within an hour was less than 1°C for indoor temperature, 3% for relative humidity, and 0.1¿m/s for indoor air velocity. Ventilation rate and window operation were found to be related to the fluctuation of the indoor temperature and air velocity, rather than the relative humidity. These findings shed light on the thermal conditions in naturally ventilated classrooms and have practical implications for the implementation of natural ventilation protocols in schools., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A comprehensive assessment of indoor air quality and thermal comfort in educational buildings in the Mediterranean climate

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
Maintaining good indoor air quality and thermal comfort is a challenge for naturally ventilated educational buildings, as it can be difficult to achieve both aspects simultaneously. Nonetheless, most of the existing studies only focus on one aspect. To explore the potential of balancing indoor air quality and thermal comfort, both topics must be investigated concurrently. This study assessed indoor air quality and thermal comfort in 32 naturally ventilated classrooms of 16 primary and secondary schools in the Mediterranean climate, based on a large on-site measurement campaign lasting one year that gathered over 460 hours of data. The research investigated occupants’ adaptive behaviors, analyzed the actual thermal comfort of around 600 students, and characterized the representative scenarios leading to good and poor indoor air quality and thermal comfort by clustering analysis. The results showed that poor indoor air quality was mainly due to closing windows and doors in winter, while thermal discomfort mainly occurred in summer because of the high indoor temperature. The findings suggested that a proper ventilation protocol is the key to balancing indoor air quality and thermal comfort., This research is part of the R&D project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by the MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student (reference no. 202208390065)., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A hierarchical integration method under social constraints to maximize satisfaction in multiple criteria group decision making systems

  • Boix Cots, David
  • Pardo Bosch, Francesc
  • Pujadas Álvarez, Pablo
Aggregating multiple opinions or assessments in a decision has always been a challenging field topic for researchers. Over the last decade, different approaches, mainly based on weighting data sources or decision-makers (DMs), have been proposed to resolve this issue, although social choice theory, focused on frameworks to combine individual opinions, is generally overlooked. To resolve this situation, a novel methodology is developed in this paper based on social choice theory and statistical mathematics. This method innovates by dividing the assessment into components which provides a multiple assessment analysis, assigning weights to each source regarding their position compared to the group for each considered criteria. This multiple-weighting process maximises individual and group satisfaction. Furthermore, the method makes it possible to manage previously assigned influence. An example is given to illustrate the proposed methodology. Additionally, sensitivity analysis is performed and comparisons with other methods are made. Finally, conclusions are presented., The first author acknowledges support from the Spanish Ministry of Education, Culture and Sports [grant number FPU18/01471]. The second and third author wish to recognise their support from the Serra Hunter programme. Finally, this work was supported by the Catalan agency AGAUR through its research group support program (2017SGR00227). This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Optimal ventilation strategies for balancing indoor air quality, comfort and energy use in educational buildings. The IAQ4EDU project.

  • Gaspar Fàbregas, Kàtia
  • Gangolells Solanellas, Marta
  • Casals Casanova, Miquel
  • Ferré Bigorra, Jaume
  • Pujadas Álvarez, Pablo
Currently, there is great concern about adequate indoor ventilation to prevent adverse effects on occupants’ health, and, within educational buildings, to ensure students and professors’ well-being and improve learning processes. This paper aims to present an innovative framework, developed within the IAQ4EDU project, to improve the effectiveness of the ventilation strategies in educational centres considering the indoor air quality, thermal comfort, energy consumption and global costs. This consists on characterise indoor air quality, simulate building ventilation strategies using reduced order models and develop multi criteria decision making method. 40 classrooms located in 20 Spanish educational buildings are used as case study., This research is part of the Catalan agency AGAUR under their research group support programme (2017SGR00227)., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Data-driven model for predicting indoor air quality and thermal comfort levels in naturally ventilated educational buildings using easily accessible data for schools

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
Modeling indoor air quality and thermal conditions in educational buildings is significant for protecting students' health, well-being, and productivity. The predictive models in existing studies were mainly built and applied in controlled environments with HVAC systems. These models did not involve occupant-related factors, had limited scope in a single building or space, and required indoor environmental monitoring data for the model input. This limits the applicability and generalization ability of the model in a large number of schools relying on natural ventilation, where indoor air quality and thermal conditions are significantly affected by occupants’ activities and ventilation practices. Hence, this paper proposes a methodology to develop a data-driven model for predicting the level of indoor air quality and thermal comfort in naturally ventilated educational buildings, and identifies the key influential factors. The model was developed using the class-weighted random forest algorithm with data collected from a large measurement campaign. The developed model demonstrated good accuracy, generalization ability, and robustness. The analysis concluded that occupancy, windows and doors operation, and outdoor environmental parameters are key factors must be involved, whereas building characteristics have no practical contribution to the prediction. The model inputs are easily accessible data for schools. Once the model is developed with data collected from an initial measurement campaign in representative educational buildings, it can be used in all local schools without requiring monitoring sensor networks, thereby rendering a “cost-effective” way of assessing indoor air quality and thermal comfort to help relevant stakeholders improve building management practices in schools., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Estimation of children’s CO2 generation rates in naturally ventilated educational buildings

  • Tugores Garcias, Juan
  • Macarulla Martí, Marcel
  • Gangolells Solanellas, Marta
Indoor CO CO 2 2 concentration serves as an indicator of indoor air quality, which is mainly influenced by occupants’ generation rate, outdoor ventilation rate and outdoor CO 2 levels. Determining the CO 2 generation rate is fundamental to design effective ventilation systems that ensure good indoor air quality. The ASTM D6245 standard offers a method to estimate human CO 2 generation based on sex, age, body mass, and activity level. However, due to the limited number of studies on CO 2 generation rate for children and adolescents in daily scholarly activities, accurated values are difficult to estimate. This research uses a stochastic grey box modelling approach to estimate CO 2 generation rates in naturally ventilated schools and compares it with the standard approach. This method can address the complexities and variations in real educational environments. The proposed model was verified through an experimental campaign including 32 classrooms with students aged 4, 10, 13 and 16 years. The model provided a detailed description of the indoor CO 2 cases. Estimated CO 2 dynamics in 72% of the studied generation rates were found to be in line with the expected standard value of between 1.0 MET to 2.0 MET activity levels (7.07–12.65 L/h for a 4-year-old, 9.63–13.29 L/h for a 10-year-old, 14.54–19.32 L/h for a 13-year-old, and 12.11–20.53 L/h for a 16-year-old). These findings not only bridge the gap in children’s CO 2 generation rates but also introduce a novel approach to assess human CO uncontrolled conditions., This research was supported by predoctoral contract grants (reference no. PRE2021-099606) as a part of the R&D project IAQ4EDU (reference no. PID2020-117366RB-I00), funded by MCIN/AEI/ 10.13039/501100011033/FEDER. This work was supported by the Catalan agency AGAUR through its research group support programme (2021 SGR 00341).The Government of Catalonia and Sabadell city council is gratefully acknowledged for allowing access to public centres. In addition, appreciation is extended to the MOVE4EDU project (reference no. PID2021-126845OB-C21 and PID2021-126845OB-C22), funded by MCIN/AEI/10.13039/501100011033/FEDER., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar::3.d - Reforçar la capacitat de tots els països, en particular els països en desenvolupament, en matèria d’alerta primerenca, reducció de riscos i gestió dels riscos per a la salut nacional i mundial, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.a - Construir i adequar instal·lacions escolars que responguin a les necessitats dels infants i les persones dis­capacitades, tinguin en compte les qüestions de gènere, i ofereixin entorns d’aprenentatge segurs, no violents, inclusius i eficaços per a totes les persones, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura::9.1 - Desenvolupar infraestructures fiables, sostenibles, resilients i de qualitat, incloent infraestructures regionals i transfrontereres, per tal de donar suport al desenvolupament econòmic i al benestar humà, amb especial atenció a l’accés assequible i equitatiu per a totes les persones, Objectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Improving the thermal comfort model for students in naturally ventilated schools: Insights from a holistic study in the Mediterranean climate

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
The thermal comfort models defined in existing standards are usually ineffective in predicting students' mean thermal sensation. Accordingly, overheating and overcooling are frequently reported, which affect students’ well-being and cause unnecessary energy waste. Existing studies have not further explored the model improvement strategies for educational buildings. Hence, this research aims to improve the mean thermal sensation prediction model for students in naturally ventilated schools by incorporating correlated factors, based on a holistic field survey in the Mediterranean climate. The results indicate that the modified extended predicted mean vote of thermal adaptations reinforced around thermal neutrality has the highest accuracy among all validated adaptive predicted mean vote models. However, the performance of the adaptive predicted mean vote models is limited by the deficiencies of the original predicted mean vote model. The overall performance of the improved models was doubled after introducing the identified correlated factors, but the intrinsic error of the predicted mean vote index can slightly affect the models. As a result, the improved model built directly with the identified correlated factors achieved the best performance. Moreover, the potential of the machine learning models is limited by the volume of the mean thermal sensation vote data that can often be obtained, therefore conventional models such as multiple linear regression can be considered an effective and practical tool for developing the mean thermal sensation vote models. The findings of this study benefit the well-being of students and the energy conservation of educational buildings., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::5 - Igualtat de Gènere, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A novel approach to calculate the mean thermal sensation vote for primary and secondary schools using Bayesian inference

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
Existing thermal comfort models defined in relevant standards are often found to be less effective for primary and secondary school students in educational buildings. This is often thought to be primarily due to differences in thermal sensation between children and adults. However, one important factor that is often neglected is the uncertainty associated with thermal comfort survey data. The existing method for calculating the mean thermal sensation vote is oversimplified and does not properly address related uncertainties. As a result, it ultimately affects the performance of the developed thermal comfort models. Hence, this research proposes a novel approach to compute the mean thermal sensation vote data for primary and secondary schools using Bayesian inference. This approach addresses the error caused by the uncertainties associated with the collected thermal sensation vote data in order to improve the effectiveness of the developed thermal comfort models for students. The proposed method was validated through a holistic case study using five thermal comfort models. The results showed that the accuracy of the developed thermal comfort models improved by 10.1% to 30.9%, and the R2 improved by 5.3% to 28.8%. A benchmark for the Bayesian model parameter setting was proposed as the reference for relevant studies. Finally, an open, user-friendly software was developed and is available to relevant users to implement the proposed approach more efficiently. The results of this research have practical implications for the development and optimization of thermal comfort models for students., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

NVAPF: an adaptive particle filter algorithm for CO2-based natural ventilation rate estimation with high temporal resolution and stability

  • Miao, Sen
  • Gangolells Solanellas, Marta
  • Tejedor Herrán, Blanca
CO2-based ventilation rate estimation techniques have been widely used in relevant studies in naturally ventilated educational buildings. Such techniques are non-invasive, low-cost, simple, accurate, and do not interfere with the activities of indoor occupants. However, the estimation is significantly affected by the CO2 measurement noise, the uncertainties associated with CO2 generation rate, and complex natural ventilation dynamics. Existing techniques were found to have limited capabilities to deal with these aspects. Therefore, this research proposed an adaptive particle filter algorithm for CO2-based natural ventilation rate estimation and validated it through a case study in an educational building. Compared with the existing transient mass balance model and the extended Kalman filter technique, the estimation stability has been improved by nearly 6 times and 3 times, respectively. More importantly, the proposed algorithm is significantly more robust to abrupt changes in indoor CO2 and can effectively avoid large drifts in the estimated ventilation rate due to sudden window opening and sudden changes in room occupancy, demonstrating great practical applicability for real-time estimation with a high temporal resolution of 1 minute. To help relevant users with practical applications, the study also analyzed the algorithm parameter settings and the impact of simplification strategies commonly used in relevant studies, such as the use of a fixed outdoor CO2 concentration, an averaged CO2 generation rate, and an assumed constant room occupancy. Finally, considering that applying the proposed algorithm requires programming skills, an open, user-friendly software has been developed for relevant users for a convenient implementation., This research is part of the R&D project IAQ4EDU, reference no. PID2020–117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. This work was supported by the Catalan Agency AGAUR under their research group support program (2021 SGR 00341). The author Sen Miao is funded by the China Scholarship Council (CSC) as a full-time PhD student, reference no. 202208390065., Peer Reviewed, 4 - Educació de Qualitat, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Assessment of airborne infection risk in naturally ventilated environments

  • Tugores Garcias, Juan
  • Macarulla Martí, Marcel
  • Gangolells Solanellas, Marta
During the COVID-19 pandemic, natural ventilation emerged as a widely recommended strategy to improve indoor air quality and reduce airborne infection risks. However, due to the inert uncertainty, accurately determining natural ventilation rates to assess the true impact of this practice proved challenging for building managers. Traditionally, the Wells-Riley approach has been used for airborne infection probability risk assessment when steady-state conditions are assumed. However, when this method is applied to naturally ventilated facilities, it may yield inaccuracies because of irregular ventilation rates caused by the occupants’ window opening patterns. The paper introduces a novel methodology for evaluating airborne infection probability in naturally ventilated environments. Firstly, natural ventilation rates are estimated using a grey box model of indoor CO2 concentration. This approach was validated using in-situ data from a case study in different periods (spring, summer and winter). Then, the infection probability risk was calculated by discretizing the accumulative virus portion inhaled by the occupants at each time. The results prove the grey box model's effectiveness in estimating natural ventilation rates in educational facilities. Concerning the evaluation of infection probability risk, the proposed approach aligns with observations in previous research that link lower ventilation rates with higher infection risk. However, the methodology provides a better representation of real-world variability than the Wells-Riley approach and enables the identification of vulnerable periods. The integration of this methodology into natural ventilation system management could optimize window-opening strategies to mitigate airborne transmission diseases in educational facilities, considering diverse infective incidence rates and pathogens., Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar::3.d - Reforçar la capacitat de tots els països, en particular els països en desenvolupament, en matèria d’alerta primerenca, reducció de riscos i gestió dels riscos per a la salut nacional i mundial, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat::4.a - Construir i adequar instal·lacions escolars que responguin a les necessitats dels infants i les persones dis­capacitades, tinguin en compte les qüestions de gènere, i ofereixin entorns d’aprenentatge segurs, no violents, inclusius i eficaços per a totes les persones, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Energy implications of meeting indoor air quality and thermal comfort standards in Mediterranean schools using natural and mechanical ventilation strategies

  • Maiques Garcia, Maria
  • Tarragona Roig, Joan
  • Gangolells Solanellas, Marta
  • Casals Casanova, Miquel
Educational buildings often face significant challenges with indoor air quality and thermal comfort, mainly due to a lack of mechanical ventilation and air conditioning systems. Research has demonstrated that these issues negatively affect students’ learning. The main objective of this paper was to assess compliance with indoor air quality and thermal comfort standards in educational buildings, by quantifying HVAC energy implications under natural and mechanical ventilation strategies. For this purpose, an educational building model that has 4 classrooms occupied by students from different age groups was simulated in 11 Mediterranean climate zones, for 4 ventilation strategies, and with 2 building orientations. The results reveal that natural ventilation is effective only in mild Mediterranean climates, with air quality non-compliance ranging from 0 % to 2 % and thermal comfort non-compliance between 2 % and 5 %. As expected, mechanical ventilation always ensures acceptable indoor air quality and thermal comfort. It achieves average HVAC energy savings of 80 % compared to natural ventilation. When considering that students’ CO2 generation rates vary depending on the age, systems with CO2 sensors further reduce HVAC demand (8 %), while maintaining comfort levels. Building orientation was found to have a significant impact for naturally ventilated buildings. South-facing orientations can reduce HVAC energy demand by up to 42 % (1,989 kWh/m2·year), whereas mechanically ventilated buildings show minimal sensitivity to orientation (up to 36 kWh/m2·year). This research will help public authorities of the educational community and architecture and engineering sectors when they are planning, designing and retrofitting educational buildings. Educational building managers will also benefit from this research by being able to optimise building ventilation through the effective management of existing resources., This research is part of the R&D project IAQ4EDU, reference no. PID2020-117366RB-I00, funded by MCIN/AEI/10.13039/ 501100011033. Maria Maiques gratefully acknowledges the Universitat Politècnica de Catalunya for the financial support of her predoctoral grant FPU-UPC 2023 Complementària, with the collaboration of Banco de Santander. This study was also supported by the Catalan Agency AGAUR under their research group support programme (2021 SGR 00341), Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Objectius de Desenvolupament Sostenible::4 - Educació de Qualitat, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Demand response approaches in a research project versus a real business

  • Barbero, Mattia
  • Canals Casals, Lluc
  • Colet Subirachs, Alba
  • Salom, Jaume
  • Corchero García, Cristina
© 2023 Elsevier. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/, Demand response through Demand Aggregation is part of the energy transition towards a green and distributed system. Although the market is open in most European countries, its practical implementation is not much successful yet. In the last decade, research presented different options to deal with demand response and aggregation. This paper compares the benefits and limitations of strategies implemented from a research perspective and the strategy followed by a recently created company to see which of the advances in research are currently useful from a business perspective. The study presents a novel decision matrix to evaluate demand response strategies. Results show that there are technical limitations in current Energy Management Systems that need to be taken into account when developing demand aggregation platforms. In addition, the study highlights the importance to propose a simple and scalable solution to allow consumers to participate actively in electricity markets and create a success business model., This research has been supported by the research and innovation programme Horizon 2020 of the European Union under the grant agreement nr. 731211 SABINA. C. Corchero work is supported by the grant IJCI-2015-26650 (MICINN). All researchers have been partially supported by the Generalitat de Catalunya, Spain (2017 SGR 1219). L. Canals Casals thanks the national project IAQ4EDU (PID2020-117366RB-100) for giving the opportunity to continue his work in this field., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Assessing the impact of the COVID-19 lockdown on the energy consumption of university buildings

  • Gaspar Fàbregas, Kàtia
  • Gangolells Solanellas, Marta
  • Casals Casanova, Miquel
  • Pujadas Álvarez, Pablo
  • Forcada Matheu, Núria
  • Macarulla Martí, Marcel
  • Tejedor Herrán, Blanca
Exceptional pandemic lockdown measures enabled singular experiments such as analysing the energy consumption of vacant buildings. This paper assesses the impact of the COVID-19 lockdown on the energy use of academic buildings. For this purpose, weather-adjusted energy use was compared before and during the lockdown, including different levels of lockdown restrictions. Results obtained for the 83 academic buildings of Universitat Politècnica de Catalunya - Barcelona Tech (UPC) reveal that the avoided energy consumption amounted to over 4.3 GWh during the post-pandemic year. However, the results indicate that academic buildings were still using approximately 46.9% of their typical energy consumption during strict lockdown. This revelation emphasizes the high environmental burden of buildings, regardless of whether they are occupied., Peer Reviewed, Objectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant, Objectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles, Objectius de Desenvolupament Sostenible::12 - Producció i Consum Responsables, Postprint (published version)