Docta Complutense
Publication Artículo científico (JournalArticle)

Correction: Feasibility study of a SiPM-fiber detector for non-invasive measurement of arterial input function for preclinical and clinical positron emission tomography

  • de Scals, Sara
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • Cortés, Laura Martínez
  • Oteo, Marta
  • Morcillo, Miguel Ángel
  • Carreras-Delgado, José Luis
  • Carreras Delgado, José Luis
  • Cabrera Martín, María Nieves
  • España Palomares, Samuel
Correction: EJNMMI Phys11, 12 (2024). https://doi.org/10.1186/s40658-024-00618-2 Following publication of the original article [1], the authors requested to update the Funding section. The original Funding sections was: This work was funded by the Universidad Complutense de Madrid under Project PR27/21 − 009 and by the Ministerio de Ciencia e Innovación under Project TED2021-129933B-C21. S. España is supported by the Ministerio de Ciencia, Innovación y Universidades under Ayudas Ramón y Cajal RYC2018-024495-I. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020-001041-S funded by MICIN/AEI/https://doi.org/10.13039/501100011033). The correct Funding section should read: This work is part of the Project TED2021-129933B-C21 funded by the MCIN/AEI/10.13039/501100011033 and the European Union NextGenerationEU/ PRTR as well as by the Universidad Complutense de Madrid under Project PR27/21-009. S. España is supported by the Ministerio de Ciencia, Innovación y Universidades under Ayudas Ramón y Cajal RYC2018-024495-I. The CNIC is supported by the Instituto de Salud Carlos III (ISCIII), the MCIN and the Pro CNIC Foundation, and is a Severo Ochoa Center of Excellence (Grant CEX2020-001041-S funded by MICIN/AEI/10.13039/501100011033). The original article [1] has been updated.
Docta Complutense
Publication Artículo científico (JournalArticle)

Feasibility study of a SiPM-fiber detector for non-invasive measurement of arterial input function for preclinical and clinical positron emission tomography

  • de Scals, Sara
  • Fraile Prieto, Luis Mario
  • Udías Moinelo, José Manuel
  • Martínez Cortés, Laura
  • Oteo, Marta
  • Morcillo, Miguel Ángel
  • Carreras Delgado, José Luis
  • Cabrera Martín, María Nieves
  • España Palomares, Samuel
Pharmacokinetic positron emission tomography (PET) studies rely on the measurement of the arterial input function (AIF), which represents the time-activity curve of the radiotracer concentration in the blood plasma. Traditionally, obtaining the AIF requires invasive procedures, such as arterial catheterization, which can be challenging, time-consuming, and associated with potential risks. Therefore, the development of non-invasive techniques for AIF measurement is highly desirable. This study presents a detector for the non-invasive measurement of the AIF in PET studies. The detector is based on the combination of scintillation fibers and silicon photomultipliers (SiPMs) which leads to a very compact and rugged device. The feasibility of the detector was assessed through Monte Carlo simulations conducted on mouse tail and human wrist anatomies studying relevant parameters such as energy spectrum, detector efficiency and minimum detectable activity (MDA). The simulations involved the use of 18F and 68Ga isotopes, which exhibit significantly different positron ranges. In addition, several prototypes were built in order to study the different components of the detector including the scintillation fiber, the coating of the fiber, the SiPMs, and the operating configuration. Finally, the simulations were compared with experimental measurements conducted using a tube filled with both 18F and 68Ga to validate the obtained results. The MDA achieved for both anatomies (approximately 1000 kBq/mL for mice and 1 kBq/mL for humans) falls below the peak radiotracer concentrations typically found in PET studies, affirming the feasibility of conducting non-invasive AIF measurements with the fiber detector. The sensitivity for measurements with a tube filled with 18F (68Ga) was 1.2 (2.07) cps/(kBq/mL), while for simulations, it was 2.81 (6.23) cps/(kBq/mL). Further studies are needed to validate these results in pharmacokinetic PET studies.