Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Control of PV power plants with quasi-Z-source cascaded H-bridge multilevel inverters under failure

  • Carrasco González, David
  • Horrillo Quintero, Pablo
  • García-Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Fernández Ramírez, Luis Miguel
At the present time, quasi-Z-source cascaded H-bridge multilevel inverters (qZS-CHBMLI) have gained attention in photovoltaic (PV) applications, due to their advantages over traditional multilevel inverters. They allow single-stage power conversion of a PV power plant by independently adjusting the DC voltage in each module; thus, each PV array operates at the maximum power. This advantage permits dispensing with a DC/DC boost converter and reduces the number of modules required. This paper develops a novel control strategy for a qZS-CHBMLI connected to a single-phase system that guarantees proper operation when a fault occurs in a quasi-impedance source inverter (qZSI). The control strategy is employed in a grid-connected qZS-CHBMLI with three modules, each one with a quasi-impedance network, a 4.8 kW PV array and a voltage source inverter (VSI), with H-bridge topology. The purpose of the control system is to deliver a suitable DC voltage at the input of the VSI and ensure the grid power requirements after a fault in a module. The proposed control system is evaluated through a 40 s simulation in MATLAB/Simulink® in two cases: A) analysis of the system behaviour when there is a variation in the operation limit equation; and B) evaluation of the control strategy under dissimilar operating conditions. In addition, an experimental setup based on an OPAL RT-4510 unit and a dSPACE MicroLabBox prototyping unit is employed to validate the results. The results confirmed the correct response of the applied strategy with the failure of a single module.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Fault-tolerant control for a microgrid with PV systems and energy storage systems integrated into quasi-Z-source cascaded H-bridge multilevel inverter

  • Horrillo Quintero, Pablo
  • García Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Fernández Ramírez, Luis Miguel
To ensure the reliability of microgrids (MGs), this paper presents a multi-fault tolerant control for a three-phase energy storage quasi-impedance multilevel-cascaded H-bridge inverter (ES-qZS-CHBMLI) with a photovoltaic (PV) power generation-based MG. In this paper, a battery energy storage system (BESS) is implemented to smooth out the PV generation fluctuations. In the event of a fault, most studies propose the injection of a fundamental zero sequence (FZS) to balance the system after a fault. However, the FZS based-method increases the modulation and it is limited by the converter operation range. The state-of-charge (SOC) unbalanced problem has traditionally been solved by balancing the BESSs as a single unit. This paper introduces an energy management system (EMS) based on the SOC proportional power distribution to balance the power injected into the grid. When one bridge faults, it is bypassed, and the remaining bridges in that phase change their operating conditions according to the references set by the EMS. Individual phase control allows multi-fault issues to be addressed. The simulation results of a three-phase grid-connected ES-qZS-CHBMLI PV-based MG implemented in MATLAB/Simulink validate the proposed multi-fault control and EMS. In addition, an experimental validation (based on OPAL RT4520 and dSPACE MicroLabBox units) confirm these results.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Optimal energy management system for grid-connected hybrid power plant and battery integrated into multilevel configuration

  • Hosseini, Ehsan
  • Horrillo Quintero, Pablo
  • Carrasco González, David
  • García Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Fernández Ramírez, Luis Miguel
A novel optimal energy management system (EMS) using a nonlinear constrained multivariable function to optimize the operation of battery energy storages (BESs) used in a hybrid power plant with wind turbine (WT) and photovoltaic (PV) power plants is proposed in this work. The hybrid power plant uses a configuration based on a battery-stored impedance-based cascaded multilevel inverter to integrate renewable energy sources (PV power plants and WT) and BESs into the grid. The new optimal EMS seeks for satisfying the demanded power while dispatching power between BESs to optimize their efficiency. A grid-connected configuration is implemented to assess the efficiency of the suggested supervisory control under changes in renewable energy (changes in wind speed and irradiation), and in a varying active and reactive powers’ request. The BES efficiency obtained from the suggested EMS is set side by side to the BES efficiency got from a conventional EMS and a model predictive control (MPC), both working based on the state-of-charge (SOC) of the BES and balancing power EMS. The results from MATLAB simulation and the experimental results with the real-time OPAL-RT simulator (OP4510, OPAL-RT) and dSPACE MicroLabBox show the effectiveness of the suggested approach and the improvement in long-term BES efficiency.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Power Sharing Control for a Microgrid with PV Power Plants, Batteries and Quasi-Z- source Cascaded H-birdge Multilevel Inverter

  • Horrillo Quintero, Pablo
  • García Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Fernández Ramírez, Luis Miguel
In recent years, Quasi-Z-source cascaded H-bridge multilevel inverters (qZS-CHBMLIs) have become an interesting solution for integrating renewable energy into the utility grid. The possibility of performing power conversion in a single stage, without an additional DC/DC converter, and a higher voltage gain, are their main advantages over traditional inverters. In addition, individual control of the maximum power point tracking (MPPT) can be achieved for each PV plant. Owing to the intermittent nature of PV power plants, battery energy storage systems (BESS) are commonly used to smooth out PV power fluctuations. This paper presents a control system for the active and reactive power delivered to the grid according to the system operator references and an EMS for an ES-qZS-CHBMLI. The BESS is coordinated through an energy management system (EMS) based on the state of charge (SOC) The system is evaluated under two different operation modes. One of them, where the PV power plants operate according to their MPP and the other in which the MPPT faults and thus, the PV power is decreased. A MATLAB-Simulink simulation is used to validate the proposed control system for a grid-connected single-phase configuration based on a qZSCHBMLI with three cascade qZSI, each connected to a 4.8 kW PV power plant and a BESS
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Optimal online battery power control of grid-connected energy-stored quasi-impedance source inverter with PV system

  • García Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Leva, Sonia
  • Fernández Ramírez, Luis Miguel
This study presents an optimal online control that implements a biogeography-based optimization (BBO) algorithm on a battery energy system (BES) integrated into an energy-stored quasi-impedance source inverter (qZSI) that connects a photovoltaic (PV) power plant to the grid. The BBO algorithm was used to tune the PI regulator in the BES current control loop by minimizing the integral time absolute error (ITAE). Two different options for the BBO are compared in this application:1) a PI controller with online self-tuning based on BBO, and 2) a PI controller with offline tuning using BBO. Moreover, the BBO-based PI controllers were compared with a third controller tuned online using the particle swarm optimization (PSO) algorithm. To evaluate and compare the controllers, a PV power plant with a battery energy-stored qZSI was simulated under different operating conditions, such as step changes in the BES current reference, different sun irradiance, and a grid voltage sag. The results demonstrate better control of the BES current with the online tuning techniques (BBO and PSO) than with the offline tuning procedure, and similar results between the two online tuning algorithms. Nevertheless, throughout the simulation, the time of use of the BBO algorithm was almost 2.5 times smaller than the PSO algorithm. Therefore, the online BBO-based PI controller is considered the most suitable option.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publication Artículo científico (JournalArticle)

Model predictive control of a microgrid with energy-stored quasi-Z-source cascaded H-bridge multilevel inverter and PV systems

  • Horrillo Quintero, Pablo
  • García Triviño, Pablo
  • Sarrias Mena, Raúl
  • García Vázquez, Carlos Andrés
  • Fernández Ramírez, Luis Miguel
This paper presents a new energy management system (EMS) based on model predictive control (MPC) for a microgrid with solar photovoltaic (PV) power plants and a quasi-Z-source cascaded H-bridge multilevel inverter that integrates an energy storage system (ES-qZS-CHBMLI). The system comprises three modules, each with a PV power plant, quasi-impedance network, battery energy storage system (BESS), and voltage source inverter (VSI). Traditional EMS methods focus on distributing the power among the BESSs to balance their state of charge (SOC), operating in charging or discharging mode. The proposed MPC-EMS carries out a multi-objective control for an ES-qZS-CHBMLI topology, which allows an optimized BESS power distribution while meeting the system operator requirements. It prioritizes the charge of the BESS with the lowest SOC and the discharge of the BESS with the highest SOC. Thus, both modes can coexist simultaneously, while ensuring decoupled power control. The MPC-EMS proposed herein is compared with a proportional sharing algorithm based on SOC (SOC-EMS) that pursues the same objectives. The simulation results show an improvement in the control of the power delivered to the grid. The Integral Time Absolute Error, ITAE, achieved with the MPC-EMS for the active and reactive power is 20 % and 4 %, respectively, lower than that obtained with the SOC-EMS. A 1,3 % higher charge for the BESS with the lowest SOC is also registered. Furthermore, an experimental setup based on an OPAL RT-4510 unit and a dSPACE MicroLabBox prototyping unit is implemented to validate the simulation results