Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Spectral attenuation of brain and retina tissues in the near-infrared range measured using a fiber-based supercontinuum device

  • Saldaña-Díaz, José Eduardo
  • Jarabo, Sebastián
  • Salgado-Remacha, Francisco Javier
  • Perdices, Lorena
  • Pinilla, Isabel
  • Sanchez-Cano, Ana
A novel setup for the efficient constant optical measurements of biological tissues in the near infrared is presented. The system combines the use of a fiber-based supercontinuum source with a simple optics fiber collimator. This configuration allows a wide spectral range of measurement and, at the same time, can efficiently filter the straightforward transmitted light while avoiding scattered light. As a performance example, the optical characterization of rat brain and retina tissues are shown. The attenuation coefficient for both tissues in the near infrared region is also obtained. This technique could be applied in clinical research as a noninvasive method with several potential practical applications.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Development of optokinetic tracking software for objective evaluation of visual function in rodents

  • Segura, Francisco
  • Arines, Justo
  • Sánchez-Cano, Ana
  • Perdices, Lorena
  • Orduna-Hospital, Elvira
  • Fuentes-Broto, Lorena
  • Pinilla, Isabel
The aim of this study was to develop software that performs the optokinetic tracking assessment without the involvement of experimenters to increase the objectivity of the test. To check the effectiveness of the software, several videos were analyzed and the results were compared to those produced by two experimenters. Videos consisted of visual acuity and contrast sensitivity tests on normal animals and pigmented P23H rats (animal model of retinitis pigmentosa). Our software showed a reasonably high success rate: in approximately 78% of the cases, both the software program and the experimenters were in agreement, including the direction of rotation. The software detected 7% false positive cases, 10% false negative cases, and it was wrong in 5% of the cases. Decrease in visual function with age in pigmented P23H rats was observed from the first time interval, although minimum thresholds were found in visual parameters at advanced ages. We developed simple software based on current functions included in the Matlab image processing toolbox that was able to recognize, with a reasonably high percentage of success, the subtle head movements of the rodent produced when visual perception of the optokinetic optotype occurs.