Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Numerical analysis and design of slender concrete-filled elliptical hollow section columns and beam-columns

  • Qiu, Wei
  • McCann, Finian
  • Gardner, Leroy
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
A numerical model simulating the behaviour of elliptical concrete-filled columns under either concentric or eccentric compressive load has been developed in ABAQUS. The numerical results have been compared against a range of experimental results for ultimate load, load deflection behaviour and failure modes, with good agreement observed. An extensive parametric study has been undertaken whereby the slenderness, load eccentricity, cross-sectional geometry and reinforcement ratio of the concrete-filled columns were varied, creating a data set upon which to formulate design guidance since currently there are no specific provisions in the European Standard EN 1994-1-1 [1] for the design of concrete-filled steel elliptical section columns or beam-columns. It is shown that the current provisions of EN 1994-1-1 [1] for the design of concrete-filled steel columns of circular or rectangular cross-section are also appropriate for the design of members of elliptical cross-section, employing either buckling curve b or c, depending on the level of steel reinforcement. Finally, an assessment is made of the reliability of the design proposals for concrete-filled elliptical hollow section columns and beam-columns., The authors would like to express their sincere gratitude to the European Union for the help provided through Project RFSR-CT-2012-00025, carried out with a financial grant from the Research Programme of the Research Fund for Coal and Steel.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Circular and square slender concrete-filled tubular columns under large eccentricities and fire

  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Serra Mercé, Enrique
Previous investigations have revealed the unsafety of the current calculation methods in Eurocode 4 for evaluating the fire resistance of concrete-filled steel tubular (CFST) columns, which has given place to a movement in Europe for correcting the existing methods and developing new design rules. In order to support the development of new guidance, further experimental research is needed, especially concerning slender columns and large eccentricities. In this paper, the results of a series of fire tests on slender CFST columns of different section shape (circular and square) subjected to large eccentricities are presented. The influence of the cross-section shape, load eccentricity and percentage of reinforcement on the response of these columns at elevated temperatures is studied in this paper, focusing on the effect of large eccentricities combined with high slenderness. On the basis of the experimental results, the current design rules in Eurocode 4 are assessed, and a previous calculation method developed by the authors is also evaluated., The authors would like to express their sincere gratitude to the European Union for the help provided through the Project RFSR-CT-2012-00025, carried out with a financial grant of the Research Programme of the Research Fund for Coal and Steel.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental investigation on the fire behaviour of rectangular and elliptical slender concrete-filled tubular columns

  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Serra Mercé, Enrique
While the fire behaviour of concrete-filled steel tubular (CFST) columns with circular and square cross-section has been well established based on experimental programs and numerical investigations, the information about the fire behaviour of CFST columns with rectangular or elliptical cross-section is very scarce. Therefore, further research is needed in order to establish the structural behaviour of concrete-filled elliptical and rectangular hollow sections at elevated temperatures as a basis for the future development of new design guidance. In this paper, a series of slender CFST columns of rectangular and elliptical cross-section are tested at elevated temperatures under both concentric and eccentric loads, reaching large eccentricities. The effect of the load eccentricity and percentage of reinforcement is studied, considering both major and minor axis buckling. The influence of the cross-section shape, load eccentricity and percentage of reinforcement on the fire behaviour of these columns is investigated. The experimental results are subsequently used to assess the current design rules in Eurocode 4 Part 1.2 for these new section shapes., The authors would like to express their sincere gratitude to the European Union for the help provided through the Project RFSR-CT-2012-00025, carried out with a financial grant of the Research Programme of the Research Fund for Coal and Steel.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular columns

  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Portolés Flag, Jose Manuel
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behavior of such innovative cross-sections under ambient and high temperatures. The test parameters covered in this experimental program were the load eccentricity (0, 20 and 50 mm) and the type of infill (plain concrete or bar-reinforced concrete). Six room temperature tests were performed, while other six tests were carried out at elevated temperatures, under both concentric and eccentric axial loads. Using the results of these tests, the current provisions of Eurocode 4 for room temperature and fire design were assessed, and a specific design proposal developed by the authors was evaluated., The authors would like to express their sincere gratitude to the European Union for the help provided through the Project RFSR-CT-2012-00025, carried out with a financial grant of the Research Programme of the Research Fund for Coal and Steel (RFSR-CT-2012-00025).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Proposal of a new method in EN1994-1-2 for the fire design of concrete-filled steel tubular columns

  • Albero, V|||0000-0001-7193-9232
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Hospitaler Pérez, Antonio|||0000-0001-7108-3104
  • Bihina, Gisèle
  • Renaud, Christophe
Previous investigations proved the unsafety of the current design guidelines in Annex H of EN 1994-1-2 for the calculation of the fire resistance of slender concrete-filled steel tubular (CFST) columns. In this paper, a new simplified design method based on the general rules in Clause 4.3.5.1 of EN 1994-1-2 is presented for correcting this inaccuracy. For the development of the method, an extensive parametric study consisting of about 20.500 analysis cases was carried out by using numerical models, which in turn were validated against a wide range of experimental results. The proposed method provides a significant extension over the current EN 1994-1-2 applicability limits, reaching high member slenderness, large eccentricities and being valid for all the commercially available geometries, including elliptical hollow sections. The design proposal is divided into two parts: thermal, where a simplified cross-sectional temperature field can be obtained based on equivalent temperatures for the composite section constituents, and mechanical, where a full method for evaluating the ultimate buckling load in the fire situation is given. The proposed method is valid for axially and eccentrically loaded columns, accounting for eccentricities on both minor and major axis and reaching large eccentricities of e/D = 1. Finally, it is proved that the proposed method provides safe predictions as compared to experimental results and meets the CEN/ TC250/SC4 accuracy criteria., The authors would like to express their sincere gratitude to the European Union for the help provided through the Project RFSR-CT-2012-00025, carried out with a financial grant of the Research Programme of the Research Fund for Coal and Steel.