Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cardiopulmonary coupling indices to assess weaning readiness from mechanical ventilation

  • Armañac-Julian, Pablo
  • Hernando, David
  • Lázaro, Jesús
  • Haro, Candelaria de
  • Magrans, Rudys
  • Morales, John
  • Moeyersons, Jonathan
  • Sarlabous, Leonardo
  • López-Aguilar, Josefina
  • Subirà, Carles
  • Fernández, Rafael
  • Orini, Michele
  • Laguna, Pablo
  • Varon, Carolina
  • Gil, Eduardo
  • Bailón, Raquel
  • Blanch, Lluís
The ideal moment to withdraw respiratory supply of patients under Mechanical Ventilation at Intensive Care Units (ICU), is not easy to be determined for clinicians. Although the Spontaneous Breathing Trial (SBT) provides a measure of the patients’ readiness, there is still around 15–20% of predictive failure rate. This work is a proof of concept focused on adding new value to the prediction of the weaning outcome. Heart Rate Variability (HRV) and Cardiopulmonary Coupling (CPC) methods are evaluated as new complementary estimates to assess weaning readiness. The CPC is related to how the mechanisms regulating respiration and cardiac pumping are working simultaneously, and it is defined from HRV in combination with respiratory information. Three different techniques are used to estimate the CPC, including Time-Frequency Coherence, Dynamic Mutual Information and Orthogonal Subspace Projections. The cohort study includes 22 patients in pressure support ventilation, ready to undergo the SBT, analysed in the 24 h previous to the SBT. Of these, 13 had a successful weaning and 9 failed the SBT or needed reintubation –being both considered as failed weaning. Results illustrate that traditional variables such as heart rate, respiratory frequency, and the parameters derived from HRV do not differ in patients with successful or failed weaning. Results revealed that HRV parameters can vary considerably depending on the time at which they are measured. This fact could be attributed to circadian rhythms, having a strong influence on HRV values. On the contrary, significant statistical differences are found in the proposed CPC parameters when comparing the values of the two groups, and throughout the whole recordings. In addition, differences are greater at night, probably because patients with failed weaning might be experiencing more respiratory episodes, e.g. apneas during the night, which is directly related to a reduced respiratory sinus arrhythmia. Therefore, results suggest that the traditional measures could be used in combination with the proposed CPC biomarkers to improve weaning readiness.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Reliability of pulse photoplethysmography sensors: Coverage using different setups and body locations

  • Armañac-Julián, Pablo
  • Kontaxis, Spyridon
  • Rapalis, Andrius
  • Marozas, Vaidotas
  • Laguna, Pablo
  • Bailón, Raquel
  • Gil, Eduardo
  • Lázaro, Jesús
Pulse photoplethysmography (PPG) is a simple and economical technique for obtaining cardiovascular information. In fact, PPG has become a very popular technology among wearable devices. However, the PPG signal is well-known to be very vulnerable to artifacts, and a good quality signal cannot be expected for most of the time in daily life. The percentage of time that a given measurement can be estimated (e.g., pulse rate) is denoted coverage (C), and it is highly dependent on the subject activity and on the configuration of the sensor, location, and stability of contact. This work aims to quantify the coverage of PPG sensors, using the simultaneously recorded electrocardiogram as a reference, with the PPG recorded at different places in the body and under different stress conditions. While many previous works analyzed the feasibility of PPG as a surrogate for heart rate variability analysis, there exists no previous work studying coverage to derive other cardiovascular indices. We report the coverage not only for estimating pulse rate (PR) but also for estimating pulse arrival time (PAT) and pulse amplitude variability (PAV). Three different datasets are analyzed for this purpose, consisting of a tilt-table test, an acute emotional stress test, and a heat stress test. The datasets include 19, 120, and 51 subjects, respectively, with PPG at the finger and at the forehead for the first two datasets and at the earlobe, in addition, for the latter. C ranges from 70% to 90% for estimating PR. Regarding the estimation of PAT, C ranges from 50% to 90%, and this is very dependent on the PPG sensor location, PPG quality, and the fiducial point (FP) chosen for the delineation of PPG. In fact, the delineation of the FP is critical in time for estimating derived series such as PAT due to the small dynamic range of these series. For the estimation of PAV, the C rates are between 70% and 90%. In general, lower C rates have been obtained for the PPG at the forehead. No difference in C has been observed between using PPG at the finger or at the earlobe. Then, the benefits of using either will depend on the application. However, different C rates are obtained using the same PPG signal, depending on the FP chosen for delineation. Lower C is reported when using the apex point of the PPG instead of the maximum flow velocity or the basal point, with a difference from 1% to even 10%. For further studies, each setup should first be analyzed and validated, taking the results and guidelines presented in this work into account, to study the feasibility of its recording devices with respect to each specific application.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Effects of sedatives and opioids on trigger and cycling asynchronies throughout mechanical ventilation: an observational study in a large dataset from critically ill patients

  • De Haro, Candelaria
  • Magrans, Rudys
  • López-Aguilar, Josefina
  • Montanyà, Jaume
  • Lena, Enrico
  • Subirà Cuyàs, Carles
  • Fernandez-Gonzalo, Sol
  • Gomà Fernández, Gemma
  • Fernández Fernández, Rafael
  • Albaiceta, Guillermo M.
  • Skrobik, Yoanna
  • Lucangelo, Umberto
  • Murias, Gastón
  • Ochagavia, Ana
  • Kacmarek, Robert M.
  • Rué, Montserrat
  • Blanch, Lluís
  • Asynchronies in the Intensive Care Unit (ASYNICU) Group
This work was funded by projects PI09/91074, PI13/02204, and PI16/01606, integrated in the Plan Nacional de R+D+I, and co-funded by the ISCIIISubdirección General de Evaluación y el Fondo Europeo de Desarrollo Regional (FEDER). RTC-2017-6193-1 (AEI/FEDER UE). CIBER Enfermedades Respiratorias, Fundación Mapfre, Fundació Parc Taulí, Plan Avanza TSI020302-2008-38, MCYIN and MITYC (Spain)., Background: In critically ill patients, poor patient-ventilator interaction may worsen outcomes. Although sedatives are often administered to improve comfort and facilitate ventilation, they can be deleterious. Whether opioids improve asynchronies with fewer negative effects is unknown. We hypothesized that opioids alone would improve asynchronies and result in more wakeful patients than sedatives alone or sedatives-plus-opioids. Methods: This prospective multicenter observational trial enrolled critically ill adults mechanically ventilated (MV) > 24 h. We compared asynchronies and sedation depth in patients receiving sedatives, opioids, or both. We recorded sedation level and doses of sedatives and opioids. BetterCare™ software continuously registered ineffective inspiratory efforts during expiration (IEE), double cycling (DC), and asynchrony index (AI) as well as MV modes. All variables were averaged per day. We used linear mixed-effects models to analyze the relationships between asynchronies, sedation level, and sedative and opioid doses. Results: In 79 patients, 14,166,469 breaths were recorded during 579 days of MV. Overall asynchronies were not significantly different in days classified as sedatives-only, opioids-only, and sedatives-plus-opioids and were more prevalent in days classified as no-drugs than in those classified as sedatives-plus-opioids, irrespective of the ventilatory mode. Sedative doses were associated with sedation level and with reduced DC (p < 0.0001) in sedatives-only days. However, on days classified as sedatives-plus-opioids, higher sedative doses and deeper sedation had more IEE (p < 0.0001) and higher AI (p = 0.0004). Opioid dosing was inversely associated with overall asynchronies (p < 0.001) without worsening sedation levels into morbid ranges. Conclusions: Sedatives, whether alone or combined with opioids, do not result in better patient-ventilator interaction than opioids alone, in any ventilatory mode. Higher opioid dose (alone or with sedatives) was associated with lower AI without depressing consciousness. Higher sedative doses administered alone were associated only with less DC., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Predicting patient-ventilator asynchronies with hidden markov models

  • Marchuk, Yaroslav
  • Magrans, Rudys
  • Sales, Bernat
  • Montanyà, Jaume
  • López-Aguilar, Josefina
  • De Haro, Candelaria
  • Gomà Fernández, Gemma
  • Subirà Cuyàs, Carles
  • Fernández Fernández, Rafael
  • Kacmarek, Robert M.
  • Blanch, Lluís
Funded by the project RTC-2017-6193-1 from the Ministry of Science, Innovation and Universities (Spain), and projects PI16/01606 and PI13/02204 from the Instituto de Salud Carlos III (Madrid, Spain) and the Fondo Europeo de Desarrollo Regional (FEDER). CIBER Enfermedades Respiratorias, Fundación Mapfre, Fundació Parc Taulí, Plan Avanza TSI-020302-2008-38, Ministerio de Ciencia e Innovación and Ministerio de Industria Turismo y Comercio (Spain)., In mechanical ventilation, it is paramount to ensure the patient’s ventilatory demand is met while minimizing asynchronies. We aimed to develop a model to predict the likelihood of asynchronies occurring. We analyzed 10,409,357 breaths from 51 critically ill patients who underwent mechanical ventilation >24 h. Patients were continuously monitored and common asynchronies were identified and regularly indexed. Based on discrete time-series data representing the total count of asynchronies, we defined four states or levels of risk of asynchronies, z1 (very-low-risk) – z4 (very-high-risk). A Poisson hidden Markov model was used to predict the probability of each level of risk occurring in the next period. Long periods with very few asynchronous events, and consequently very-low-risk, were more likely than periods with many events (state z4). States were persistent; large shifts of states were uncommon and most switches were to neighbouring states. Thus, patients entering states with a high number of asynchronies were very likely to continue in that state, which may have serious implications. This novel approach to dealing with patient-ventilator asynchrony is a first step in developing smart alarms to alert professionals to patients entering high-risk states so they can consider actions to improve patient-ventilator interaction., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Development and validation of a sample entropy-based method to identify complex patient-ventilator interactions during mechanical ventilation

  • Sarlabous, Leonardo
  • Aquino‑Esperanza, José
  • Magrans, Rudys
  • De Haro, Candelaria
  • López-Aguilar, Josefina
  • Subirà Cuyàs, Carles
  • Batlle, Montserrat
  • Rué, Montserrat
  • Gomà Fernández, Gemma
  • Ochagavia, Ana
  • Fernández Fernández, Rafael
  • Blanch, Lluís
Patient-ventilator asynchronies can be detected by close monitoring of ventilator screens by clinicians or through automated algorithms. However, detecting complex patient-ventilator interactions (CP-VI), consisting of changes in the respiratory rate and/or clusters of asynchronies, is a challenge. Sample Entropy (SE) of airway flow (SE-Flow) and airway pressure (SE-Paw) waveforms obtained from 27 critically ill patients was used to develop and validate an automated algorithm for detecting CP-VI. The algorithm’s performance was compared versus the gold standard (the ventilator’s waveform recordings for CP-VI were scored visually by three experts; Fleiss’ kappa = 0.90 (0.87–0.93)). A repeated holdout cross-validation procedure using the Matthews correlation coefficient (MCC) as a measure of effectiveness was used for optimization of different combinations of SE settings (embedding dimension, m, and tolerance value, r), derived SE features (mean and maximum values), and the thresholds of change (Th) from patient’s own baseline SE value. The most accurate results were obtained using the maximum values of SE-Flow (m = 2, r = 0.2, Th = 25%) and SE-Paw (m = 4, r = 0.2, Th = 30%) which report MCCs of 0.85 (0.78–0.86) and 0.78 (0.78–0.85), and accuracies of 0.93 (0.89–0.93) and 0.89 (0.89–0.93), respectively. This approach promises an improvement in the accurate detection of CP-VI, and future study of their clinical implications., info:eu-repo/semantics/publishedVersion
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Effects of sedatives and opioids on trigger and cycling asynchronies throughout mechanical ventilation, An observational study in a large dataset from critically ill patients

  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Magrans, Rudys
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Montanyà, Jaume
  • Lena, Enrico
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Gomà, Gemma|||0000-0002-1890-4855
  • Fernández, Rafael
  • Albaiceta, Guillermo M.|||0000-0002-9276-3253
  • Skrobik, Yoanna|||0000-0002-5315-6020
  • Lucangelo, Umberto
  • Murias, Gastón
  • Ochagavía Calvo, Ana|||0000-0002-0564-2913
  • Kacmarek, Robert M.
  • Rué, Montserrat|||0000-0002-7862-9365
  • Blanch, Lluís|||0000-0002-4158-7464
Background: In critically ill patients, poor patient-ventilator interaction may worsen outcomes. Although sedatives are often administered to improve comfort and facilitate ventilation, they can be deleterious. Whether opioids improve asynchronies with fewer negative effects is unknown. We hypothesized that opioids alone would improve asynchronies and result in more wakeful patients than sedatives alone or sedatives-plus-opioids. Methods: This prospective multicenter observational trial enrolled critically ill adults mechanically ventilated (MV).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Automated detection and quantification of reverse triggering effort under mechanical ventilation

  • Pham, Tài|||0000-0002-4373-0711
  • Montanya, Jaume
  • Telias, Irene
  • Piraino, Thomas|||0000-0002-4887-8686
  • Magrans, Rudys
  • Coudroy, Rémi
  • Damiani, L. Felipe|||0000-0002-8338-0488
  • Mellado Artigas, Ricard|||0000-0003-2815-6819
  • Madorno, Matías
  • Blanch, Lluís|||0000-0002-4158-7464
  • Brochard, Laurent
Reverse triggering (RT) is a dyssynchrony defined by a respiratory muscle contraction following a passive mechanical insufflation. It is potentially harmful for the lung and the diaphragm, but its detection is challenging. Magnitude of effort generated by RT is currently unknown. Our objective was to validate supervised methods for automatic detection of RT using only airway pressure (Paw) and flow. A secondary objective was to describe the magnitude of the efforts generated during RT. We developed algorithms for detection of RT using Paw and flow waveforms. Experts having Paw, flow and esophageal pressure (Pes) assessed automatic detection accuracy by comparison against visual assessment. Muscular pressure (Pmus) was measured from Pes during RT, triggered breaths and ineffective efforts. Tracings from 20 hypoxemic patients were used (mean age 65 ± 12 years, 65% male, ICU survival 75%). RT was present in 24% of the breaths ranging from 0 (patients paralyzed or in pressure support ventilation) to 93.3%. Automatic detection accuracy was 95.5%: sensitivity 83.1%, specificity 99.4%, positive predictive value 97.6%, negative predictive value 95.0% and kappa index of 0.87. Pmus of RT ranged from 1.3 to 36.8 cmH0, with a median of 8.7 cmH0. RT with breath stacking had the highest levels of Pmus, and RTs with no breath stacking were of similar magnitude than pressure support breaths. An automated detection tool using airway pressure and flow can diagnose reverse triggering with excellent accuracy. RT generates a median Pmus of 9 cmHO with important variability between and within patients. BEARDS, NCT03447288.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Predicting Patient-ventilator Asynchronies with Hidden Markov Models

  • Marchuk, Yaroslav
  • Magrans, Rudys
  • Sales, Bernat
  • Montanya, Jaume
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Gomà, Gemma|||0000-0002-1890-4855
  • Subirà, Carles|||0000-0003-2285-2311
  • Fernández, Rafael
  • Kacmarek, Robert M.
  • Blanch, Lluís|||0000-0002-4158-7464
In mechanical ventilation, it is paramount to ensure the patient's ventilatory demand is met while minimizing asynchronies. We aimed to develop a model to predict the likelihood of asynchronies occurring. We analyzed 10,409,357 breaths from 51 critically ill patients who underwent mechanical ventilation.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

The Effect of Clusters of Double Triggering and Ineffective Efforts in Critically Ill Patients

  • Magrans, Rudys
  • Ferreira, Francini
  • Sarlabous, Leonardo|||0000-0002-0495-8422
  • López-Aguilar, Josefina|||0000-0003-2359-3980
  • Gomà, Gemma|||0000-0002-1890-4855
  • Fernández-Gonzalo, Sol|||0000-0003-0267-0617
  • Navarra-Ventura, Guillem|||0000-0001-9839-7357
  • Fernández, Rafael
  • Montanyà, Jaume
  • Kacmarek, Robert
  • Rué, Montserrat|||0000-0002-7862-9365
  • Forne, Carles|||0000-0002-8133-3274
  • Blanch, Lluís|||0000-0002-4158-7464
  • Haro López, Candelaria de|||0000-0002-2668-1030
  • Aquino Esperanza, Jose
OBJECTIVES: To characterize clusters of double triggering and ineffective inspiratory efforts throughout mechanical ventilation and investigate their associations with mortality and duration of ICU stay and mechanical ventilation. DESIGN: Registry-based, real-world study. Background: Asynchronies during invasive mechanical ventilation can occur as isolated events or in clusters and might be related to clinical outcomes. Subjects: Adults requiring mechanical ventilation greater than 24 hours for whom greater than or equal to 70% of ventilator waveforms were available. INTERVENTIONS: We identified clusters of double triggering and ineffective inspiratory efforts and determined their power and duration. We used Fine-Gray's competing risk model to analyze their effects on mortality and generalized linear models to analyze their effects on duration of mechanical ventilation and ICU stay. MEASUREMENTS AND MAIN RESULTS: We analyzed 58,625,796 breaths from 180 patients. All patients had clusters (mean/d, 8.2 [5.4-10.6]; mean power, 54.5 [29.6-111.4]; mean duration, 20.3 min [12.2-34.9 min]). Clusters were less frequent during the first 48 hours (5.5 [2.5-10] vs 7.6 [4.4-9.9] in the remaining period [p = 0.027]). Total number of clusters/d was positively associated with the probability of being discharged alive considering the total period of mechanical ventilation (p = 0.001). Power and duration were similar in the two periods. Power was associated with the probability of being discharged dead (p = 0.03), longer mechanical ventilation (p < 0.001), and longer ICU stay (p = 0.035); cluster duration was associated with longer ICU stay (p = 0.027). CONCLUSIONS: Clusters of double triggering and ineffective inspiratory efforts are common. Although higher numbers of clusters might indicate better chances of survival, clusters with greater power and duration indicate a risk of worse clinical outcomes.