Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improving lifespan automation for Caenorhabditis elegans by using image processing and a post-processing adaptive data filter

  • Puchalt-Rodríguez, Joan Carles|||0000-0002-9432-8319
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Ivorra, Eugenio|||0000-0001-6062-2061
  • Genovés Martínez, Salvador
  • Martínez, Roberto
  • Martorell Guerola, Patricia
[EN] Automated lifespan determination for C. elegans cultured in standard Petri dishes is challenging. Problems include occlusions of Petri dish edges, aggregation of worms, and accumulation of dirt (dust spots on lids) during assays, etc. This work presents a protocol for a lifespan assay, with two image-processing pipelines applied to different plate zones, and a new data post-processing method to solve the aforementioned problems. Specifically, certain steps in the culture protocol were taken to alleviate aggregation, occlusions, contamination, and condensation problems. This method is based on an active illumination system and facilitates automated image sequence analysis, does not need human threshold adjustments, and simplifies the techniques required to extract lifespan curves. In addition, two image-processing pipelines, applied to different plate zones, were employed for automated lifespan determination. The first image-processing pipeline was applied to a wall zone and used only pixel level information because worm size or shape features were unavailable in this zone. However, the second image-processing pipeline, applied to the plate centre, fused information at worm and pixel levels. Simple death event detection was used to automatically obtain lifespan curves from the image sequences that were captured once daily throughout the assay. Finally, a new post-processing method was applied to the extracted lifespan curves to filter errors. The experimental results showed that the errors in automated counting of live worms followed the Gaussian distribution with a mean of 2.91% and a standard deviation of +/- 12.73% per Petri plate. Post-processing reduced this error to 0.54 +/- 8.18% per plate. The automated survival curve incurred an error of 4.62 +/- 2.01%, while the post-process method reduced the lifespan curve error to approximately 2.24 +/- 0.55%., This study was also supported by the CDTI agency of the Spanish Ministry of Economy and Competitiveness with CIEN project SMARTFOODS, Universitat PolitAcnica de Valencia with Project 20170020-UPV, Plan Nacional de I + D with Project RTI2018-094312-B-I00 and by European FEDER funds. ADM Nutrition, Biopolis SL and Archer Daniels Midland provided support in the form of salaries for authors P. M. Guerola and S. G. Martinez.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Reducing Results Variance in Lifespan Machines: An Analysis of the Influence of Vibrotaxis on Wild-Type Caenorhabditis elegans for the Death Criterion

  • Puchalt-Rodríguez, Joan Carles|||0000-0002-9432-8319
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Layana-Castro, Pablo Emmanuel
[EN] Nowadays, various artificial vision-based machines automate the lifespan assays of C. elegans. These automated machines present wider variability in results than manual assays because in the latter worms can be poked one by one to determine whether they are alive or not. Lifespan machines normally use a "dead or alive criterion" based on nematode position or pose changes, without poking worms. However, worms barely move on their last days of life, even though they are still alive. Therefore, a long monitoring period is necessary to observe motility in order to guarantee worms are actually dead, or a stimulus to prompt worm movement is required to reduce the lifespan variability measure. Here, a new automated vibrotaxis-based method for lifespan machines is proposed as a solution to prompt a motion response in all worms cultured on standard Petri plates in order to better distinguish between live and dead individuals. This simple automated method allows the stimulation of all animals through the whole plate at the same time and intensity, increasing the experiment throughput. The experimental results exhibited improved live-worm detection using this method, and most live nematodes (>93%) reacted to the vibration stimulus. This method increased machine sensitivity by decreasing results variance by approximately one half (from +/- 1 individual error per plate to +/- 0.6) and error in lifespan curve was reduced as well (from 2.6% to 1.2%)., This study was also supported by the Universitat Politecnica de Valencia with Project 20170020-UPV, Plan Nacional de I+D with Project RTI2018-094312-B-I00 and by European FEDER funds. ADM Nutrition, Biopolis SL and Archer Daniels Midland provided support in the supply of C. elegans.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Towards Lifespan Automation for Caenorhabditis elegans Based on Deep Learning: Analysing Convolutional and Recurrent Neural Networks for Dead or Live Classification

  • García-Garví, Antonio|||0000-0002-3676-8287
  • Puchalt-Rodríguez, Joan Carles|||0000-0002-9432-8319
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Layana-Castro, Pablo Emmanuel
  • Navarro Moya, Francisco
[EN] The automation of lifespan assays with C. elegans in standard Petri dishes is a challenging problem because there are several problems hindering detection such as occlusions at the plate edges, dirt accumulation, and worm aggregations. Moreover, determining whether a worm is alive or dead can be complex as they barely move during the last few days of their lives. This paper proposes a method combining traditional computer vision techniques with a live/dead C. elegans classifier based on convolutional and recurrent neural networks from low-resolution image sequences. In addition to proposing a new method to automate lifespan, the use of data augmentation techniques is proposed to train the network in the absence of large numbers of samples. The proposed method achieved small error rates (3.54% +/- 1.30% per plate) with respect to the manual curve, demonstrating its feasibility., This study was supported by the Plan Nacional de I + D under the project RTI2018-094312B-I00 and by the European FEDER funds.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A new training strategy for spatial transform networks (STN&apos, s)

  • Navarro Moya, Francisco
  • Layana-Castro, Pablo Emmanuel
  • Puchalt-Rodríguez, Joan Carles|||0000-0002-9432-8319
  • García-Garví, Antonio|||0000-0002-3676-8287
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
[EN] Spatial transform networks (STN) are widely used since they can transform images captured from different viewpoints to obtain an objective image. These networks use an image captured from any viewpoint as input and the desired image as a label. Usually, these images are segmented, but this could lead to convergence problems if the percentage of overlap between the segmented images is quite low. In this paper, we propose a new training method to facilitate the convergence of a STN in these cases, even when there is no overlap between the object's projections in the two images. This new strategy is based on the incorporation of the distance transformation images to the training, thus increasing the useful image information to provide gradients in the loss function. This new training strategy has been applied to a real case, with images of Caenorhabditis elegans, and to a simulated case, which uses artificial images to ensure that there is no overlap between the images used for the assays. In the assays carried out with these datasets, we have shown that the training convergence is strengthened, reaching a precision level for IoU metric of 0.862 and 0.984, respectively, and the computational cost has been maintained compared to the assay with segmented images, for the real case., This study was also supported by Plan Nacional de I+D under the project RTI2018-094312-B-I00 and by the European FEDER funds. Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.